Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 33(5): 3510-3520, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36651956

RESUMO

OBJECTIVES: To evaluate anatomical and volumetric predictability of a cone beam computed tomography (CBCT)-based virtual parenchymal perfusion (VPP) software for the single-photon-emission computed tomography (SPECT)/CT imaging results during the work-up for transarterial radioembolization (TARE) procedure in patients with hepatocellular carcinoma (HCC). METHODS: VPP was evaluated retrospectively on CBCT data of patients treated by TARE for HCC. 99mTc macroaggregated albumin particles (99mTc-MAA) uptake territories on work-up SPECT/CT was used as ground truth for the evaluation. Semi-quantitative evaluation consisted of the ranking of visual consistency of the parenchymal enhancement and portal vein tumoral involvement on VPP and 99mTc-MAA SPECT/CT, using a three-rank scale and two-rank scale, respectively. Inter-reader agreement was evaluated using a kappa coefficient. Quantitative evaluation included absolute volume error calculation and Pearson correlation between volumes enhanced territories on VPP and 99mTc-MAA SPECT/CT. RESULTS: Fifty-two CBCTs were performed in 33 included patients. Semi-quantitative evaluation showed a good concordance between actual 99mTc-MAA uptake and the virtual enhanced territories in 73% and 75% of cases; a mild concordance in 12% and 10% and a poor concordance in 15%, for the two readers. Kappa coefficient was 0.86. Portal vein involvement evaluation showed a good concordance in 58.3% and 66.7% for the two readers, respectively, with a kappa coefficient of 0.82. Quantitative evaluation showed a volume error of 0.46 ± 0.78 mL [0.01-3.55], and Pearson R2 factor at 0.75 with a p value < 0.01. CONCLUSION: CBCT-based VPP software is accurate and reliable to predict 99mTc-MAA SPECT/CT anatomical and volumetric results in HCC patients during TARE. KEY POINTS: • Virtual parenchymal perfusion (VPP) software is accurate and reliable in the prediction of 99mTc-MAA SPECT volumetric and targeting results in HCC patients during transarterial radioembolization (TARE). • VPP software may be used per-operatively to optimize the microcatheter position for 90Y infusion allowing precise tumor targeting while preserving non-tumoral parenchyma. • Post-operatively, VPP software may allow an accurate estimation of the perfused volume by each arterial branch and, thus, a precise 90Y dosimetry for TARE procedures.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Agregado de Albumina Marcado com Tecnécio Tc 99m , Radioisótopos de Ítrio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico , Embolização Terapêutica/métodos , Algoritmos , Software , Perfusão , Microesferas
2.
AJR Am J Roentgenol ; 218(2): 359-369, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34494448

RESUMO

BACKGROUND. Assessment of hepatocellular carcinoma (HCC) treatment response after transarterial radioembolization (TARE) is challenging, because response by conventional imaging criteria may not become apparent until 6 months after treatment. Though HCC exhibits variable avidity for FDG, some cases of HCC without avidity for FDG show avidity for 18F-fluorocholine (18F-FCH). OBJECTIVE. The purpose of this study was to evaluate the utility of early posttreatment evaluation by PET/CT using FDG or 18F-FCH to predict 6-month treatment response and survival after TARE in patients with HCC. METHODS. This retrospective study included 37 patients (mean age, 67 years; 34 men, three women) with documented HCC treated by TARE who underwent both pre-treatment FDG PET/CT and 18F-FCH PET/CT and early FDG PET/CT and/or 18F-FCH PET/CT 4-8 weeks after treatment; FDG PET/CT and 18F-FCH PET/CT examinations were performed on separate dates. Only one of 73 initially identified potentially eligible patients was excluded because of lack of HCC avidity for both FDG and 18F-FCH. Response assessment by modified RECIST (mRECIST) on multiphase CT or MRI was performed at 1 month and 6 months in 23 patients. Early responses seen on PET/CT and 1-month mRECIST response were assessed as predictors of 6-month mRECIST response. Univariable and multivariable predictors of overall survival (OS) were identified. RESULTS. On pretreatment PET/CT, 28 (76%) patients were FDG-positive (showed visual uptake on FDG PET/CT and tumor-to-normal liver ratio > 1.15), 15 (41%) were FCH-positive (showed visual uptake on 18F-FCH PET/CT), and six (16%) were both FDG-positive and FCH-positive. Twelve of 28 FDG-positive HCCs exhibited early response by FDG PET/CT; seven of 15 FCH-positive HCCs exhibited early response by 18F-FCH PET/CT. Twelve (52%) patients exhibited 6-month mRECIST response. Response seen on early posttreatment PET/CT exhibited 100% (12/12) sensitivity and 100% (11/11) specificity for 6-month mRECIST response, whereas 1-month mRECIST response exhibited 67% (8/12) sensitivity and 100% (11/11) specificity for 6-month mRECIST response. Response seen on early posttreatment PET/CT was a significant independent predictor of OS on univariable (hazard ratio [HR], 0.4; 95% CI, 0.2-0.9; p = .03) and multivariable (HR, 0.2; 95% CI, 0.1-0.8; p = .01) analyses. CONCLUSION. Early evaluation after TARE by PET/CT using FDG or 18F-FCH may pre dict 6-month response and OS in patients with HCC. CLINICAL IMPACT. Early posttreatment evaluation with PET/CT could help more reliably identify true nonresponders after TARE, which in turn could prompt early response-adapted therapeutic management.


Assuntos
Braquiterapia/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Idoso , Colina/análogos & derivados , Feminino , Fluordesoxiglucose F18 , Humanos , Fígado/diagnóstico por imagem , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Radioisótopos de Ítrio/administração & dosagem
3.
Radiology ; 300(2): 326-335, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34100681

RESUMO

Background CT can provide information regarding myocardial perfusion and expansion of the extracellular space, which is relevant to patients with cardiac amyloidosis (CA). Purpose To evaluate the role of CT in the diagnosis and prognosis of CA. Materials and Methods In this prospective study (Commission National de l'Informatique et des Libertés registration no. 1431858), participants with CA, participants with nonamyloid cardiac hypertrophy (NACH), and participants without hypertrophy were included between April 2017 and December 2018. The confirmed diagnosis of CA was determined according to established criteria (ie, proven with positive bone scintigraphy or endomyocardial biopsy). All participants were imaged with dynamic CT perfusion imaging at whole-heart cardiac CT. Extracellular volume measured at CT and myocardial perfusion parameters calculated on CT perfusion maps were compared among different participant groups. Differences between continuous data were tested using the unpaired t test, Mann-Whitney rank-sum test, or the Kruskal-Wallis test. Results A total of 84 participants with CA, 43 participants with NACH, and 33 participants without hypertrophy were included. Participants with CA exhibited a higher value of extracellular volume measured at CT (mean, 54.7% ± 9.7 [standard deviation]) than participants with NACH (mean, 34.6% ± 9.1; P < .001) and participants without hypertrophy (mean, 35.9% ± 9.9; P = .001). Mean myocardial blood volume and mean myocardial blood flow were lower in participants with CA (mean myocardial blood volume: 4.05 mL/100 g of myocardium ± 0.80; mean myocardial blood flow: 73.2 mL/100 g of myocardium per minute ± 25.7) compared to participants with NACH (mean myocardial blood volume: 5.38 mL/100 g of myocardium ± 1.20, P < .001; mean myocardial blood flow: 89.6 mL/100 g of myocardium per minute ± 31.3, P = .007) and participants without hypertrophy (mean myocardial blood volume: 5.68 mL/100 g of myocardium ± 1.05; mean myocardial blood flow: 106.3 mL/100 g of myocardium per minute ± 29.8; P < .001 for both). Extracellular volume measured at CT (hazard ratio >0.56 vs ≤0.56 = 4.2 [95% CI: 1.4, 11.8]), mean slope (hazard ratio ≤3.0 sec-1 vs >3.0 sec-1 = 0.2 [95% CI: 0.1, 0.8]), and time to peak (hazard ratio >20 seconds vs ≤20 seconds = 11.6 [95% CI: 1.3, 101.6]) were predictive of mortality in participants with CA. Conclusion Participants with cardiac amyloidosis exhibited an increase in extracellular volume at CT and abnormal CT perfusion parameters. Extracellular volume and several perfusion parameters were predictive of mortality. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Zimmerman in this issue.


Assuntos
Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada por Raios X , Idoso , Biomarcadores/sangue , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos
4.
Eur J Vasc Endovasc Surg ; 62(2): 204-213, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33994306

RESUMO

OBJECTIVE: The aim was to describe initial outcomes of physician modified stent grafts using antegrade laser fenestrations and image fusion guidance (LEVAR) and company manufactured custom made (CM) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs), thoraco-abdominal aortic aneurysms (TAAAs) and type I endoleaks (T1ELs). METHODS: This was a retrospective single centre study. All LEVAR and Zenith (Cook) CM stent graft procedures between 1 January 2012 and 31 December 2018 were reviewed. Endpoints included intra-operative adverse events (IOAEs), in hospital mortality, re-interventions, target vessel patency, and 12 month outcomes (overall survival, freedom from re-intervention, target vessel patency). Outcomes at 12 months were estimated using the Kaplan-Meier method. RESULTS: A hundred patients were identified and included in the study. All patients were deemed unfit for open repair. The cohort included 22 LEVAR and 78 CM stent grafts. LEVAR cases included painful aneurysms (n = 5), > 65 mm aneurysms (n = 10), anatomical constrains and/or presence of previous renal stents (n = 7) or cases declined by the manufacturer planning centre (n = 2). IOAEs were recorded in 41% of cases (n = 9) in the LEVAR group vs. 10% (n = 8, p = .002) in the CM group. The in hospital mortality rate in the LEVAR group was 9% (n = 2) vs. 4% (n = 3, p = .30) in the CM group. The median follow up duration was 22 months (7 - 38) in the LEVAR group and 28 months (11 - 78) in the CM group. The estimate of overall survival at one year was 91% in both groups. The freedom from re-intervention rate at one year was 58% in the LEVAR group vs. 87% in the CM group. The target vessel patency rates at one year were 95% in both groups. CONCLUSION: In high risk patients deemed unfit for open repair, LEVAR may provide satisfactory 12 month overall survival and target vessel patency rates, though reported IOAE, mortality, and re-interventions rates were high thus requiring close and extensive follow up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Tomografia Computadorizada de Feixe Cônico , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Fluoroscopia , Mortalidade Hospitalar , Humanos , Complicações Intraoperatórias/etiologia , Terapia a Laser , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Complicações Pós-Operatórias/etiologia , Reoperação , Estudos Retrospectivos , Stents/efeitos adversos , Cirurgia Assistida por Computador , Taxa de Sobrevida , Grau de Desobstrução Vascular
5.
Ann Vasc Surg ; 71: 533.e7-533.e12, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32927040

RESUMO

BACKGROUND: We report a case of juxtarenal abdominal aortic aneurysm-anatomically unsuitable for conventional endovascular repair because of narrow distal aorta-successfully treated by endovascular repair facilitated by in situ laser fenestration. METHODS AND RESULTS: An aortic stent graft was inserted to exclude a juxtarenal aneurysm: under image fusion guidance, antegrade in situ laser fenestration allowed to perfuse superior mesenteric artery and both renal arteries. After complementary insertion of an extended aortouni-iliac stent graft, retrograde in situ laser fenestration was performed to perfuse the contralateral left iliac artery, in order to overcome a narrow distal aorta. Postoperative course was uneventful. Six month's CT showed an excluded aneurysm, patency of the inserted stents and the absence of endoleak. CONCLUSIONS: In situ laser fenestration seems to be an effective solution for endovascular therapy of complex juxtarenal aneurysms. In this case of narrow distal aorta it was a suitable alternative to overcome endovascular aneurysm repair anatomical restrictions and to prevent other additional open surgical interventions.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Fluxo Sanguíneo Regional , Resultado do Tratamento , Grau de Desobstrução Vascular
6.
Radiology ; 295(3): 562-571, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32228294

RESUMO

Background The recently described "macrotrabecular-massive" (MTM) histologic subtype of hepatocellular carcinoma (HCC) (MTM-HCC) represents an aggressive form of HCC and is associated with poor survival. Purpose To investigate whether preoperative MRI can help identify MTM-HCCs in patients with HCC. Materials and Methods This retrospective study included patients with HCC treated with surgical resection between January 2008 and February 2018 and who underwent preoperative multiphase contrast material-enhanced MRI. Least absolute shrinkage and selection operator (LASSO)-penalized and multivariable logistic regression analyses were performed to identify clinical, biologic, and imaging features associated with the MTM-HCC subtype. Early recurrence (within 2 years) and overall recurrence were evaluated by using Kaplan-Meier analysis. Multivariable Cox regression analysis was performed to determine predictors of early and overall recurrence. Results One hundred fifty-two patients (median age, 64 years; interquartile range, 56-72 years; 126 men) with 152 HCCs were evaluated. Twenty-six of the 152 HCCs (17%) were MTM-HCCs. LASSO-penalized logistic regression analysis identified substantial necrosis, high serum α-fetoprotein (AFP) level (>100 ng/mL), and Barcelona Clinic Liver Cancer (BCLC) stage B or C as independent features associated with MTM-HCCs. At multivariable analysis, substantial necrosis (odds ratio = 32; 95% confidence interval [CI] = 8.9, 114; P < .001), high serum AFP level (odds ratio = 4.4; 95% CI = 1.3, 16; P = .02), and BCLC stage B or C (odds ratio = 4.2; 95% CI = 1.2, 15; P = .03) were independent predictors of MTM-HCC subtype. Substantial necrosis helped identify 65% (17 of 26; 95% CI: 44%, 83%) of MTM-HCCs (sensitivity) with a specificity of 93% (117 of 126; 95% CI: 87%, 97%). In adjusted models, only the presence of satellite nodules was independently associated with both early (hazard ratio = 3.7; 95% CI: 1.5, 9.4; P = .006) and overall (hazard ratio = 3.0; 95% CI: 1.3, 7.2; P = .01) tumor recurrence. Conclusion At multiphase contrast-enhanced MRI, substantial necrosis helped identify macrotrabecular-massive hepatocellular carcinoma subtype with high specificity. © RSNA, 2020.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Carcinoma Hepatocelular/classificação , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Estimativa de Kaplan-Meier , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/classificação , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/classificação , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Prognóstico , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
J Vasc Surg ; 71(6): 1834-1842.e1, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31708298

RESUMO

OBJECTIVE: Physician-modified fenestrated stent grafts (PMSGs) are a useful option for urgent or semiurgent treatment of complex abdominal aortic aneurysms (CAAAs). The aim of this study was to describe in-hospital outcomes of custom-made fenestrated stent grafts (CMSGs) and PMSGs for the treatment of CAAAs and thoracoabdominal aortic aneurysms (TAAAs). METHODS: In this single-center, retrospective study, all consecutives patients with CAAAs or TAAAs undergoing endovascular repair using Zenith CMSGs (Cook Medical, Bloomington, Ind) or PMSGs between January 2012 and November 2017 were included. End points were intraoperative adverse events, in-hospital mortality, postoperative complications, reinterventions, target vessel patency, and endoleaks. RESULTS: Ninety-seven patients were included (CMSGs, n = 69; PMSGs, n = 28). The PMSG group included more patients assigned to American Society of Anesthesiologists class 4 (n = 14 [50%] vs n = 16 [23%]; P = .006) and more TAAAs (n = 17 [61%] vs n = 10 [15%]; P < .0001). Intraoperative adverse events were recorded in eight (11%) patients in the CMSG group vs six (21%) patients in the PMSG group. No intraoperative death or open conversion occurred. In-hospital mortality rates were of 4% (n = 3) in the CMSG group and 14% in the PMSG group (n = 4). Chronic renal failure was an independent preoperative risk factor of postoperative death or complications (odds ratio, 4.88; 95% confidence interval, 1.65-14.43; P = .004). Rates of postoperative complications were 22% (n = 15) and 25% (n = 7) in the CMSG and PMSG groups. Spinal cord ischemia rates were 4% (n = 3) and 7% (n = 2) in the CMSG and PMSG groups. Reintervention rates were 16% (n = 11) in the CMSG group and 32% (n = 9) in the PMSG group. At discharge, target vessel patency rate in CMSGs was 98% (n = 207/210). All target vessels (n = 98) were patent in the PMSG group. Endoleaks at discharge were observed in 24% of the CMSG group (n = 16) vs 8% of the PMSG group (n = 2). CONCLUSIONS: Our study showed clinically relevant differences of several important in-hospital outcomes in the CMSG and PMSG groups. Larger cohorts and longer follow-up are needed to allow direct comparison. PMSGs may offer acceptable in-hospital results in patients requiring urgent interventions when CMSGs are not available or possible.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Eur Radiol ; 30(10): 5348-5357, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32405753

RESUMO

OBJECTIVES: To compare the performance of the quantitative analysis of the hepatobiliary phase (HBP) tumor enhancement in gadobenate dimeglumine (Gd-BOPTA)-enhanced MRI and of dual-tracer 18F-FDG and 18F-fluorocholine (FCH) PET/CT for the prediction of tumor aggressiveness and recurrence-free survival (RFS) in resectable hepatocellular carcinoma (HCC). METHODS: This retrospective, IRB approved study included 32 patients with 35 surgically proven HCCs. All patients underwent Gd-BOPTA-enhanced MRI including delayed HBP images, 18F-FDG PET/CT, and (for 29/32 patients) 18F-FCH PET/CT during the 2 months prior to surgery. For each lesion, the lesion-to-liver contrast enhancement ratio (LLCER) on MRI HBP images and the SUVmax tumor-to-liver ratio (SUVT/L) for both tracers were calculated. Their predictive value for aggressive pathological features-including the histological grade and microvascular invasion (MVI)-and RFS were analyzed and compared using area under receiver operating characteristic (AUROC) curves and Cox regression models, respectively. RESULTS: The AUROCs for the identification of aggressive HCCs on pathology with LLCER, 18F-FDG SUVT/L, and 18F-FCH SUVT/L were 0.92 (95% CI 0.78, 0.98), 0.89 (95% CI 0.74, 0.97; p = 0.70), and 0.64 (95% CI 0.45, 0.80; p = 0.035). At multivariate Cox regression analysis, LLCER was identified as an independent predictor of RFS (HR (95% CI) = 0.91 (0.84, 0.99), p = 0.022). LLCER - 4.72% or less also accurately predicted moderate-poor differentiation grade (Se = 100%, Sp = 92.9%) and MVI (Se = 93.3%, Sp = 60%) and identified patients with poor RFS after surgical resection (p = 0.030). CONCLUSIONS: HBP tumor enhancement after Gd-BOPTA injection may help identify aggressive HCC pathological features, and patients with reduced recurrence-free survival after surgical resection. KEY POINTS: • In patients with resectable HCC, the quantitative analysis of the HBP tumor enhancement in Gd-BOPTA-enhanced MRI (LLCER) accurately identifies moderately-poorly differentiated and/or MVI-positive HCCs. • After surgical resection for HCC, patients with LLCER - 4.72% or less had significantly poorer recurrence-free survival than patients with LLCER superior to - 4.72%. • Gd-BOPTA-enhanced MRI with delayed HBP images may be suggested as part of pre-surgery workup in patients with resectable HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/cirurgia , Colina/análogos & derivados , Meios de Contraste , Intervalo Livre de Doença , Feminino , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/cirurgia , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Compostos Organometálicos , Compostos Radiofarmacêuticos , Recidiva , Estudos Retrospectivos
9.
Eur J Vasc Endovasc Surg ; 60(1): 135-143, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32312666

RESUMO

OBJECTIVE: Fiber Optic RealShape (FORS) is a new technology platform that enables real time three dimensional (3D) visualisation of endovascular guidewires and catheters, based on the concepts of fibre optic technology instead of fluoroscopy. Anatomical context is provided by means of co-registered prior anatomical imaging, such as digital subtraction angiography or computed tomography. This preclinical study assesses the safety and feasibility of FORS technology. METHODS: Six physicians performed endovascular tasks in a phantom model and a porcine model using FORS enabled floppy guidewires, Cobra-2 catheters and Berenstein catheters. Each physician performed a set of predefined tasks in both models, including setup of the FORS system, device registration, and 12 aortic and peripheral target vessel cannulation tasks. The evaluation of the FORS system was based on (i) target vessel cannulation success; (ii) safety assessment; (iii) the accuracy of the FORS based device visualisation; and (iv) user experience. RESULTS: Successful cannulation was achieved in 72 of the 72 tasks (100%) in the phantom model and in 70 of the 72 tasks (97%) in the porcine model. No safety issues were reported. The FORS based device visualisation had a median offset at the tip of 2.2 mm (interquartile range 1.2-3.8 mm). The users judged the FORS based device visualisation to be superior to conventional fluoroscopic imaging, while not affecting the mechanical properties (torquability, pushability) of the FORS enabled guidewire and catheters. CONCLUSION: The combined outcomes of high cannulation success, positive user experience, adequate accuracy, and absence of safety issues demonstrate the safety and feasibility of the FORS system in a preclinical environment. FORS technology has great potential to improve device visualisation in endovascular interventions.


Assuntos
Procedimentos Endovasculares/instrumentação , Tecnologia de Fibra Óptica , Imageamento Tridimensional/instrumentação , Dispositivos de Acesso Vascular , Animais , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/patologia , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Procedimentos Endovasculares/métodos , Feminino , Tecnologia de Fibra Óptica/métodos , Humanos , Imageamento Tridimensional/métodos , Suínos
10.
Eur Radiol ; 28(2): 816-823, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28812126

RESUMO

OBJECTIVE: To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). METHODS: Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. RESULTS: IVS thickness was significantly (p < 0.001) higher in CA (17 ± 4 mm) and CH (15 ± 3 mm) patients than in control patients (10 ± 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 ± 0.12) and ECV (0.56 ± 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 ± 0.07 and 0.36 ± 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 ± 0.07 and 0.35 ± 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. CONCLUSION: Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters. KEY POINT: • Dual-energy computed tomography can be used to detect cardiac amyloidosis • Five-minute myocardial iodine concentration and iodine ratio increase in cardiac amyloidosis • Among iodine parameters, 5-minute iodine ratio has the best diagnosis performance.


Assuntos
Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Iodo/metabolismo , Miocárdio/metabolismo , Tomografia Computadorizada por Raios X/métodos , Idoso , Amiloidose/metabolismo , Cardiomiopatias/metabolismo , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Feminino , Humanos , Masculino , Projetos Piloto , Interpretação de Imagem Radiográfica Assistida por Computador
11.
J Vasc Interv Radiol ; 29(2): 254-261.e2, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29191614

RESUMO

PURPOSE: To evaluate accuracy of virtual parenchymal perfusion (VPP) algorithm developed for targeting liver cancer during intra-arterial therapy (IAT) using cone-beam CT guidance. MATERIALS AND METHODS: VPP was retrospectively applied to 15 patients who underwent IAT for liver cancer. Virtual territory (VT) was estimated after positioning a virtual injection point on nonselective dual-phase (DP) cone-beam CT images acquired during hepatic arteriography at the same position chosen for selective treatment. Targeted territory (TT) was used as the gold standard and was defined by parenchymal phase enhancement of selective DP cone-beam CT performed before treatment start. Qualitative evaluation of anatomic conformity between VT and TT was performed using a 3-rank scale (poor, acceptable, excellent) by 3 double-blinded readers. VT and TT were also quantitatively compared using spatial overlap-based (Dice similarity coefficient [DSC], sensitivity, and positive predictive value), distance-based (mean surface distance [MSD]), and volume-based (absolute volume error and correlation between pairwise volumes) metrics. Interreader agreement was evaluated for the 2 evaluation methods. RESULTS: Eighteen DP cone-beam CT scans were performed. Qualitative evaluation showed excellent overlap between VT and TT in 88.9%-94.4%, depending on the readers. DSC was 0.78 ± 0.1, sensitivity was 80%, positive predictive value was 83%, and MSD was 5.1 mm ± 2.4. Absolute volume error was 15%, and R2 Pearson correlation factor was 0.99. Interreader agreement was good for both qualitative and quantitative evaluations. CONCLUSIONS: VPP algorithm is accurate and reliable in identification of liver arterial territories during IAT using cone-beam CT guidance.


Assuntos
Algoritmos , Antineoplásicos/administração & dosagem , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Radiografia Intervencionista , Meios de Contraste , Feminino , Humanos , Infusões Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
12.
J Vasc Interv Radiol ; 29(3): 425-431, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29402612

RESUMO

PURPOSE: To evaluate the performance of automated feeder detection (AFD) software (EmboGuide; Philips Healthcare, Best, The Netherlands) on hepatocellular carcinoma (HCC) tumors during transarterial chemoembolization. MATERIALS AND METHODS: Forty-four first-time transarterial chemoembolization patients (37 men; mean age, 62 ± 11 years) were enrolled between May 2012 and July 2013. A total of 86 HCC lesions were treated (2.0 ± 1.4 lesions per patient; 27.6 ± 15.9 mm maximum diameter). One hundred forty-seven feeding arteries were found with digital subtraction angiography (DSA), cone-beam computed tomography (CT), and AFD software with the option of manual adjustment (MA). Three independent interventional radiologists analyzed the cone-beam CT images retrospectively with and without AFD and MA. Compared with the number of treated vessels, the number of true positives, false positives, false negatives, sensitivity, and interreader agreement were determined using clustered binary data analysis. RESULTS: Cone-beam CT enabled detection of 100 ± 3.5 feeding arteries (70% sensitivity) with 68.6% agreement among readers. AFD software significantly improved detection to 127±0.6 feeding arteries (86% sensitivity, P = .008) with 99.7% reader agreement and reduced the number of false negatives from an average of 47 ± 3.5 to 20 ± 0.6 (P = .008). MA of the AFD results produced similar feeding artery detection rates (127 ± 5.1, 86% sensitivity, P = .8), with lower interreader agreement (91.6%) and slightly fewer false positives (16 ± 0.0 to 14 ± 2.5, P = .4). CONCLUSIONS: AFD software significantly improved feeding artery detection rates during transarterial chemoembolization of HCC lesions with better user reproducibility compared with cone-beam CT alone. In conjunction with DSA, AFD enables maximum feeding artery detection in this setting.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Radiografia Intervencionista/métodos , Software , Angiografia Digital , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Ann Vasc Surg ; 51: 200-206, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29772329

RESUMO

BACKGROUND: The aim of this retrospective study was to examine the impact of graft oversizing on gutter area and stent compression in chimney graft (CG) for complex abdominal aortic aneurysm (CAAA) repair. The influence of stent-graft oversizing on type Ia endoleaks and bridging stent occlusion rates was also examined. METHODS: Preoperative and postoperative computed tomographic angiography scans of patients requiring CGs for CAAA between June 2009 and April 2013 in our institution were analyzed. Two groups were identified: proximal oversizing of the stent-graft component < 25% (group 1) and >25% (group 2). Relative gutter areas were calculated and compared between both groups. Incidence of target vessel stent compression, target vessel occlusions, and type Ia endoleaks was also analyzed. RESULTS: Of 39 patients treated with CG during the study period, 23 fulfilled the selection criteria for analysis. Group 1 included 10 patients and group 2 included 13 patients (mean oversizing: 18.4 ± 4.9% and 34.5 ± 6% respectively). Relative gutter areas were significantly higher in group 1 when compared with group 2 (6.1 ± 2.1% vs. 4.2 ± 3.2%, P = 0.03). No stent compression and no target vessel occlusion occurred in either groups. There was no statistical difference in type Ia endoleak in both groups (group 1 n = 0, group 2 n = 2; P = 0.48). CONCLUSIONS: In our study, a >25% stent-graft oversizing reduced the gutter area without modifying the bridging stent patency. However, no benefit in terms of type Ia endoleak was observed.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , França , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Dados Preliminares , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
14.
Ann Vasc Surg ; 42: 303.e1-303.e4, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28389286

RESUMO

BACKGROUND: Spinal cord ischemia (SCI) is a severe complication of extended endovascular repair of thoracoabdominal aneurysms. We describe voluntary interruption of side-branch completion in staged branched endovascular aneurysm treatment due to uncertainty regarding SCI possible onset, based on intraoperative angiography findings. METHODS: We report a case of a staged endovascular treatment of thoracoabdominal aortic aneurysm in a 64-year-old patient using a branched endograft with an additional side branch that allows temporary sac perfusion to prevent SCI. The third operative step was intended to occlude the side branch. Intraoperative angiography through the side branch demonstrated circulating aneurysm sac, with patent inferior intercostal and superior lumbar arteries giving direct blood supply to a clearly visible anterior spinal artery. The procedure was stopped. RESULTS: One month later, sac thrombosis occurred spontaneously and was clinically responsible for neurogenic claudication that resolved during follow-up. CONCLUSION: Interrupting side-branch completion seems to have allowed additional ischemic conditioning of the spinal cord as the spontaneous sac thrombosis induced mild neurological event.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Isquemia do Cordão Espinal/prevenção & controle , Medula Espinal/irrigação sanguínea , Stents , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Hemodinâmica , Humanos , Claudicação Intermitente/etiologia , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Isquemia do Cordão Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/fisiopatologia , Resultado do Tratamento
15.
Ann Vasc Surg ; 40: 44-49, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28161564

RESUMO

BACKGROUND: On November 13, 2015, Paris and Saint-Denis were the targets of terrorist attacks. The Public Hospitals of Paris Organization and the Percy Armed Forces Instruction Hospitals were mobilized to face the mass casualty situation. The objective of this study is to analyze the management of the victims presenting with a nonthoracic vascular trauma (NTVT). METHODS: All the data relating to the victims of NTVT who required a specific vascular open or endovascular treatment were analyzed retrospectively. A 6-month follow-up was obtained for all the patients. RESULTS: Among the 351 wounded, 20 (5.7%) patients had an NTVT and were dispatched in 8 hospitals (11 men of average age 32). NTVTs were gunshots in 17 cases (85%) or due to a handmade bomb in 3 cases (15%). Twelve patients (60%) received cardiopulmonary resuscitation during prehospital care. NTVT affected the limbs (14 cases, 70%) and the abdomen or the small pelvis (6 cases, 30%). All the patients were operated in emergency. Arterial lesions were treated with greater saphenous vein bypasses, by ligation, and/or embolization. Eleven venous lesions were treated by direct repair or ligation. Associated lesions requiring a specific treatment were present in 19 patients (95%) and were primarily osseous, nervous, and abdomino-pelvic. Severe postoperative complications were observed in 9 patients (45%). Fourteen patients (70%) required blood transfusion (6.4 U of packed red blood cells on average, range 0-48). There were no deaths or amputation and all vascular reconstructions were patent at 6 months. CONCLUSIONS: The effectiveness of the prehospital emergency services and a multisite and multidisciplinary management made it possible to obtain satisfactory results for NTVT casualties. All the departments of vascular surgery must be prepared to receive many wounded victims in the event of terrorist attacks.


Assuntos
Traumatismos por Explosões/terapia , Bombas (Dispositivos Explosivos) , Embolização Terapêutica , Serviços Médicos de Emergência , Procedimentos Endovasculares , Substâncias Explosivas , Terrorismo , Procedimentos Cirúrgicos Vasculares , Lesões do Sistema Vascular/terapia , Adulto , Traumatismos por Explosões/diagnóstico por imagem , Traumatismos por Explosões/etiologia , Traumatismos por Explosões/fisiopatologia , Transfusão de Sangue , Prestação Integrada de Cuidados de Saúde , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Emergências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Ligadura , Masculino , Pessoa de Meia-Idade , Paris , Equipe de Assistência ao Paciente , Estudos Retrospectivos , Veia Safena/transplante , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/fisiopatologia , Adulto Jovem
16.
Surg Radiol Anat ; 39(2): 149-160, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27344346

RESUMO

PURPOSE: Endovascular navigation in aortic, renal and visceral procedures are based on precise knowledge of arterial anatomy. Our aim was to define the anatomical localization of the ostia of renovisceral arteries and their distribution to establish anatomical landmarks for endovascular catheterization. METHODS: Computer-assisted measurements performed on 55 CT scans and patients features (age, sex, aortic diameter) were analyzed. p values <0.05 were considered statistically significant. RESULTS: The mean axial angulation of CeT and the SMA origin was 21.8° ± 10.1° and 9.9° ± 10.5°, respectively. The ostia were located on the left anterior edge of the aorta in 96 % of cases for the CeT and 73 % for the SMA. CeT and SMA angles followed Gaussian distribution. Left renal artery (LRA) rose at 96° ± 15° and in 67 % of cases on the left posterior edge. The right renal artery (RRA) rose at -62° ± 16.5° and in 98 % of cases on the right anterior edge of the aorta. RRA angle measurements and cranio-caudal RRA-LRA distance measurements did not follow Gaussian distribution. The mean distances between the CeT and the SMA, LRA, and RRA were 16.7 ± 5.0, 30.7 ± 7.9 and 30.5 ± 7.7 mm, respectively. CeT-SMA distance showed correlation with age and aortic diameter (p = 0.03). CeT-LRA distance showed correlation with age (p = 0.04). The mean distance between the renal ostia was 3.75 ± 0.21 mm. The RRA ostium was higher than the LRA ostium in 52 % of cases. RRA and LRA origins were located at the same level in 7 % of cases. CONCLUSION: Our results illustrate aortic elongation with ageing and high anatomical variability of renal arteries. Our findings are complementary to anatomical features previously published and might contribute to enhance endovascular procedures safety and efficacy for vascular surgeons and interventional radiologists.


Assuntos
Aorta Abdominal/anatomia & histologia , Artéria Celíaca/anatomia & histologia , Rim/irrigação sanguínea , Artéria Mesentérica Superior/anatomia & histologia , Artéria Renal/anatomia & histologia , Fatores Etários , Idoso , Variação Anatômica , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais
18.
J Vasc Interv Radiol ; 27(2): 188-93, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26830935

RESUMO

Magnetic resonance (MR) angiography image fusion (IF) with live fluoroscopy guidance was used while performing endovascular repair of abdominal aortic aneurysm (EVAR) in five patients with a history of chronic renal disease or severe contrast allergy. Intraprocedural technical success was 100%. Median procedure time was 120 minutes (range, 60-180 min), fluoroscopy time was 40 minutes (range, 17-65 min), dose-area product was 245,867 mGy × cm(2) (range, 68,435-690,053 mGy × cm(2)), and iodinated contrast volume injected was 15 mL (range, 0-40 mL). Technical success was achieved in four of five patients (80%); one case was complicated by a type 1 endoleak on follow-up MR angiography, which was successfully treated. EVAR with MR angiography IF guidance was technically feasible and safe in five patients and reduced or eliminated the use of iodinated contrast media.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista
19.
Artigo em Inglês | MEDLINE | ID: mdl-26923140

RESUMO

PURPOSE: To evaluate the technical feasibility of automatically removing the ribs and spine from C-arm cone-beam computed tomography (CBCT) images acquired during transcatheter arterial chemoembolization (TACE). MATERIAL AND METHODS: Fifty-eight patients (45.8 ± 5.0 years) with unresectable hepatocellular carcinoma (HCC) underwent transcatheter arterial chemoembolization and had intraprocedural CBCT imaging. Automatic bone removal was performed using model-based segmentation of the ventral cavity. Two interventional radiologists independently evaluated the performance of bone removal, remaining soft tissue retention, and general usability (where both the bone is appropriately removed while retaining soft tissue) for 3D TACE planning on a four-level (complete/excellent, adequate/good, incomplete/questionable, insufficient/bad) score. The proportion of inter-reader agreement was calculated. RESULTS: For ribs and spine removal, 98.3-100% and 100% of cases showed complete or adequate performance, respectively. In 96.6% of the cases, soft tissue was at least adequately retained. 91.3-93.1% of the cases demonstrated good or excellent general usability for TACE planning. Satisfactory inter-reader agreement proportion was achieved in ribs (93.1%) and spine removal (89.7%), soft tissue retention (84.5%), and general usability for TACE planning (72.4%). CONCLUSION: Intraprocedural automatic bone removal on CBCT images is technically feasible and offers good removal of ribs and spine while preserving soft tissue. Its clinical value needs further assessment.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/terapia , Adulto , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Costelas , Coluna Vertebral
20.
J Vasc Surg ; 61(2): 304-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25154564

RESUMO

BACKGROUND: Proximal aortic control by endovascular balloon occlusion (EBO) is an alternative to conventional aortic cross-clamping (CAC) in hemodynamically unstable patients presenting with a ruptured abdominal aortic aneurysm (rAAA). The aim of this study was to evaluate the potential clinical benefit of EBO over CAC. METHODS: Data from 72 patients with rAAA treated at our institution from 2001 to 2013 were retrospectively analyzed. All patients were hemodynamically unstable (mean arterial blood pressure at admission <65 mm Hg or associated unconsciousness, cardiac arrest, or emergency endotracheal intubation). Clinical end points of hemodynamic restoration, mortality rate, and major postoperative complications were assessed for CAC (group 1) and EBO (group 2). RESULTS: At admission, 72 patients were unstable. CAC was performed in 40 and EBO in 32. Intraoperative mortality was 43% in group 1 vs 19% in group 2 (P = .031). In group 1, the approach for CAC (thoracotomy [n = 23] vs laparotomy [n = 17]) did not influence intraoperative mortality (43% vs 41%). There was no significant difference in 30-day (75% vs 62%) and in-hospital (77% vs 69%) mortality rates between groups. After EBO, the treatment-open vs endovascular repair-did not influence the intraoperative mortality rate (31% vs 43%; P = .5). Eight surgical complications were secondary to CAC (1 vena cava injury, 3 left renal vein injuries, 1 left renal artery injury, 1 pancreaticoduodenal vein injury, and 2 splenectomies), but no EBO-related complication was noted (P = .04). Differences in colon ischemia (15% vs 28%) and renal failure (12% vs 9%) were not statistically significant. Abdominal compartment syndrome occurred in four patients in group 2 and in no patients in group 1. CONCLUSIONS: Compared with CAC, EBO is a feasible and valuable strategy and is associated with reduced intraoperative mortality of unstable rAAA patients, but not in-hospital mortality, in this retrospective study.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Ruptura Aórtica/terapia , Oclusão com Balão , Implante de Prótese Vascular , Procedimentos Endovasculares , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Oclusão com Balão/efeitos adversos , Oclusão com Balão/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Constrição , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , França , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa