Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
J Cardiovasc Electrophysiol ; 34(2): 468-477, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36651349

RESUMO

The purpose of this paper was to highlight the importance of the anatomy of the right ventricular outflow tract (RVOT) and the proximity of the mid segment of the left anterior descending coronary artery (LAD) to the RVOT in the setting of ablation of ventricular arrhythmias in the RVOT. During the period from 2014 till 2017, five patients with injury to the LAD during ablation within RVOT were identified in three centers, in Belgium, Germany and Israel. The clinical characteristics, procedural data and follow up data, where available, are reported. The literature review over coronary artery damage during radiofrequency ablation procedures is provided and the anatomy of the RVOT and the neighboring vascular structures is discussed. We present five patients who underwent radiofrequency ablation of ventricular arrhythmias mapped to the inferior and anterior part of the RVOT, at the insertion of the right ventricular wall to the septum, whereby ablation resulted in occlusion in four and severe stenosis in one, of the mid segment of the LAD coronary artery. All patients underwent percutaneous coronary intervention and stenting, four of them immediately during the same procedure and one 3 days later because of lack of signs and symptoms of acute coronary occlusion. In conclusion, the mid segment of the LAD at the level of the second septal perforator/second diagonal branch runs in very close proximity to the endocardial aspect of the lower part of the RVOT and care should be taken during ablation of ventricular arrhythmias in this region. Additional imaging such as intracardiac echocardiography and coronary angiography may be helpful in avoiding complications.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Eletrocardiografia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
3.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335976

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. METHODS AND RESULTS: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3-5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. CONCLUSION: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Adesões Focais , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
4.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35647644

RESUMO

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Adulto Jovem
5.
Europace ; 23(6): 918-927, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33221854

RESUMO

AIMS: We identified the first Belgian SCN5A founder mutation, c.4813 + 3_4813 + 6dupGGGT. To describe the clinical spectrum and disease severity associated with this mutation, clinical data of 101 SCN5A founder mutation carriers and 46 non-mutation carrying family members from 25 Belgian families were collected. METHODS AND RESULTS: The SCN5A founder mutation was confirmed by haplotype analysis. The clinical history and electrocardiographic parameters of the mutation carriers and their family members were gathered and compared. A cardiac electrical abnormality was observed in the majority (82%) of the mutation carriers. Cardiac conduction defects, defined as PR or QRS prolongation on electrocardiogram (ECG), were most frequent, occurring in 65% of the mutation carriers. Brugada syndrome (BrS) was the second most prevalent phenotype identified in 52%, followed by atrial dysrythmia in 11%. Overall, 33% of tested mutation carriers had a normal sodium channel blocker test. Negative tests were more common in family members distantly related to the proband. Overall, 23% of the mutation carriers were symptomatic, with 8% displaying major adverse events. As many as 13% of the patients tested with a sodium blocker developed ventricular arrhythmia. One family member who did not carry the founder mutation was diagnosed with BrS. CONCLUSION: The high prevalence of symptoms and sensitivity to sodium channel blockers in our founder population highlights the adverse effect of the founder mutation on cardiac conduction. The large phenotypical heterogeneity, variable penetrance, and even non-segregation suggest that other genetic (and environmental) factors modify the disease expression, severity, and outcome in these families.


Assuntos
Síndrome de Brugada , Canal de Sódio Disparado por Voltagem NAV1.5 , Bélgica/epidemiologia , Eletrocardiografia , Humanos , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Fenótipo
6.
Hum Mutat ; 41(6): 1091-1111, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32112656

RESUMO

Filamin C (FLNC) variants are associated with cardiac and muscular phenotypes. Originally, FLNC variants were described in myofibrillar myopathy (MFM) patients. Later, high-throughput screening in cardiomyopathy cohorts determined a prominent role for FLNC in isolated hypertrophic and dilated cardiomyopathies (HCM and DCM). FLNC variants are now among the more prevalent causes of genetic DCM. FLNC-associated DCM is associated with a malignant clinical course and a high risk of sudden cardiac death. The clinical spectrum of FLNC suggests different pathomechanisms related to variant types and their location in the gene. The appropriate functioning of FLNC is crucial for structural integrity and cell signaling of the sarcomere. The secondary protein structure of FLNC is critical to ensure this function. Truncating variants with subsequent haploinsufficiency are associated with DCM and cardiac arrhythmias. Interference with the dimerization and folding of the protein leads to aggregate formation detrimental for muscle function, as found in HCM and MFM. Variants associated with HCM are predominantly missense variants, which cluster in the ROD2 domain. This domain is important for binding to the sarcomere and to ensure appropriate cell signaling. We here review FLNC genotype-phenotype correlations based on available evidence.


Assuntos
Cardiomiopatias/genética , Filaminas/genética , Doenças Musculares/genética , Animais , Arritmias Cardíacas/genética , Cardiomiopatia Dilatada/genética , Modelos Animais de Doenças , Estudos de Associação Genética , Humanos , Mutação , Miopatias Congênitas Estruturais/genética
7.
Eur Heart J ; 39(16): 1394-1403, 2018 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-29300888

RESUMO

Aims: To evaluate the effect of telemonitoring on adherence to non-vitamin K antagonist oral anticoagulants (NOACs) in atrial fibrillation (AF) patients. Methods and results: A randomized, single-blind, crossover, controlled trial in 48 AF patients on once or twice daily (OD or BID) NOAC. The Medication Event Monitoring System tracked NOAC intake during three phases of 3 months each: daily telemonitoring, telemonitoring with immediate telephone feedback in case of intake errors, and an observation phase without daily transmissions. Unprotected days were defined as ≥ 3 or ≥ 1 consecutively missed doses for a BID or OD NOAC, respectively, or excess dose intake. Cost-effectiveness was calculated based on anticipated stroke reduction derived from patients' risk profile and measured intake. Persistence over the entire study was 98%. Telemonitoring-only already led to very high taking and regimen adherence (97.4% respectively 93.8%). Nevertheless, direct feedback further improved both to 99.0% and 96.8%, respectively (P < 0.001 respectively P = 0.002). Observation without daily monitoring resulted in a significant waning of taking adherence (94.3%; P = 0.049). Taking adherence was significantly higher for OD compared to BID NOAC, although unprotected days were similar. Feedback intervention had an incremental cost of €344 289 to prevent one stroke, but this could be as low as €15 488 in high-risk patients with low adherence and optimized technology. Conclusion: Telemonitoring resulted in high NOAC adherence due to the notion of being watched, as evidenced by the rapid decline during the observation period. Feedback further optimized adherence. Telemonitoring with or without feedback may be a cost-effective approach in high-risk patients deemed poorly adherent.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Adesão à Medicação , Monitorização Ambulatorial/métodos , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Análise Custo-Benefício , Estudos Cross-Over , Retroalimentação , Feminino , Humanos , Masculino , Monitorização Ambulatorial/economia , Pirazóis/administração & dosagem , Pirazóis/uso terapêutico , Piridonas/administração & dosagem , Piridonas/uso terapêutico , Rivaroxabana/administração & dosagem , Rivaroxabana/uso terapêutico , Método Simples-Cego , Acidente Vascular Cerebral/prevenção & controle
8.
Europace ; 19(1): 29-39, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26893496

RESUMO

AIMS: To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. METHODS AND RESULTS: Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA2DS2-VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. CONCLUSION: Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting. It must exclude patients with implanted devices and known AF, and requires targeted additional 12-lead ECGs to optimize specificity. Under these circumstances, the expenses per diagnosed new AF patient and preventable stroke are reasonable.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Serviço Hospitalar de Cardiologia , Telefone Celular , Eletrocardiografia/instrumentação , Geriatria , Sistema de Condução Cardíaco/fisiopatologia , Hospitalização , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/economia , Fibrilação Atrial/fisiopatologia , Bélgica , Serviço Hospitalar de Cardiologia/economia , Telefone Celular/economia , Simulação por Computador , Análise Custo-Benefício , Eletrocardiografia/economia , Desenho de Equipamento , Feminino , Geriatria/economia , Frequência Cardíaca , Custos Hospitalares , Humanos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Modelos Econômicos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Centros de Atenção Terciária
10.
Front Genet ; 15: 1392527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38836037

RESUMO

Background: Variants in the MYBPC3 gene are a frequent cause of hypertrophic cardiomyopathy (HCM) but display a large phenotypic heterogeneity. Founder mutations are often believed to be more benign as they prevailed despite potential negative selection pressure. We detected a pathogenic variant in MYBPC3 (del exon 23-26) in several probands. We aimed to assess the presence of a common haplotype and to describe the cardiac characteristics, disease severity and long-term outcome of mutation carriers. Methods: Probands with HCM caused by a pathogenic deletion of exon 23-26 of MYBPC3 were identified through genetic screening using a gene panel encompassing 59 genes associated with cardiomyopathies in a single genetic center in Belgium. Cascade screening of first-degree relatives was performed, and genotype positive relatives were further phenotyped. Clinical characteristics were collected from probands and relatives. Cardiac outcomes included death, heart transplantation, life-threatening arrhythmia, heart failure hospitalization or septal reduction therapy. Haplotype analysis, using microsatellite markers surrounding MYBPC3, was performed in all index patients to identify a common haplotype. The age of the founder variant was estimated based on the size of the shared haplotype using a linkage-disequilibrium based approach. Results: We identified 24 probands with HCM harbouring the MYBPC3 exon 23-26 deletion. Probands were on average 51 ± 16 years old at time of clinical HCM diagnosis and 62 ± 10 years old at time of genetic diagnosis. A common haplotype of 1.19 Mb was identified in all 24 probands, with 19 of the probands sharing a 13.8 Mb haplotype. The founder event was estimated to have happened five generations, or 175-200 years ago, around the year 1830 in central Flanders. Through cascade screening, 59 first-degree relatives were genetically tested, of whom 37 (62.7%) were genotype positive (G+) and 22 (37.3%) genotype negative (G-). They were on average 38 ± 19 years old at time of genetic testing. Subsequent clinical assessment revealed a HCM phenotype in 19 (51.4%) G+ relatives. Probands were older (63 ± 10 vs. 42 ± 21 years; p < 0.001) and had more severe phenotypes than G+ family members, presenting with more symptoms (50% vs. 13.5%; p = 0.002), arrhythmia (41.7% vs. 12.9%, p = 0.014), more overt hypertrophy and left ventricular outflow tract obstruction (43.5% vs. 3.0%; p < 0.001). Male G+ relatives more often had a HCM phenotype (78.6% vs. 34.8%; p = 0.010) and were more severely affected than females. At the age of 50, a penetrance of 78.6% was observed, defined as the presence of HCM in 11 of 14 G+ relatives with age ≥50 years. Overall, 20.3% of all variant carriers developed one of the predefined cardiac outcomes after a median follow-up of 5.5 years with an average age of 50 (±21) years. Conclusion: A Belgian founder variant, an exon 23-26 deletion in MYBPC3, was identified in 24 probands and 37 family members. The variant is characterized by a high penetrance of 78.6% at the age of 50 years but has variable phenotypic expression. Adverse outcomes were observed in 20.3% of patients during follow-up.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38869506

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38864809

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

13.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430087

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento , Sistema de Registros
14.
NPJ Genom Med ; 9(1): 22, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531898

RESUMO

Pathogenic loss-of-function variants in BGN, an X-linked gene encoding biglycan, are associated with Meester-Loeys syndrome (MRLS), a thoracic aortic aneurysm/dissection syndrome. Since the initial publication of five probands in 2017, we have considerably expanded our MRLS cohort to a total of 18 probands (16 males and 2 females). Segregation analyses identified 36 additional BGN variant-harboring family members (9 males and 27 females). The identified BGN variants were shown to lead to loss-of-function by cDNA and Western Blot analyses of skin fibroblasts or were strongly predicted to lead to loss-of-function based on the nature of the variant. No (likely) pathogenic missense variants without additional (predicted) splice effects were identified. Interestingly, a male proband with a deletion spanning the coding sequence of BGN and the 5' untranslated region of the downstream gene (ATP2B3) presented with a more severe skeletal phenotype. This may possibly be explained by expressional activation of the downstream ATPase ATP2B3 (normally repressed in skin fibroblasts) driven by the remnant BGN promotor. This study highlights that aneurysms and dissections in MRLS extend beyond the thoracic aorta, affecting the entire arterial tree, and cardiovascular symptoms may coincide with non-specific connective tissue features. Furthermore, the clinical presentation is more severe and penetrant in males compared to females. Extensive analysis at RNA, cDNA, and/or protein level is recommended to prove a loss-of-function effect before determining the pathogenicity of identified BGN missense and non-canonical splice variants. In conclusion, distinct mechanisms may underlie the wide phenotypic spectrum of MRLS patients carrying loss-of-function variants in BGN.

15.
J Interv Card Electrophysiol ; 66(9): 2081-2089, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37059926

RESUMO

BACKGROUND: Visually guided laser balloon (VGLB) ablation is a balloon-based treatment for atrial fibrillation (AF) that uses a titratable laser energy source to perform pulmonary vein isolation (PVI), allowing for real-time visualization of target tissue and ablation lesions through an endoscopic camera. Few long-term data on this technique are currently available. This report presents acute efficacy, procedural data, complication rates, and long-term AF-free survival up to 5 years post-ablation. METHODS: In this single-center, retrospective, observational report, 152 patients (72.4% male, mean age 60.6 ± 9.7 years, 62.5% paroxysmal AF, 598 pulmonary veins in total) treated with the first-generation VGLB system between 2014 and 2016 were included for analysis. AF ablation consisted of PVI only. RESULTS: Acute PVI was achieved in 98.2% of veins, with first-pass isolation in 92.5%. Procedure duration of 129 min [IQR 113-150], fluoroscopy time of 15 min [IQR 11-20], and dose area product of 5016 mGy·cm2 [IQR 3603-8711] were recorded. During a median follow-up of 51 months [IQR 45-57], 74.3% of patients remained free of AF (78.8% for paroxysmal and 65.3% for persistent AF, p = 0.108). Freedom of AF at 1, 2, 3, and 4 years follow-up was 88.2%, 82.2%, 78.9%, and 74.8%, respectively. PV reconnections were identified in only 46.9% of redo procedures. The median number of PV reconnections during redo procedures was 0 [IQR 0-2]. Anti-arrhythmic drug use was significantly reduced after ablation (p < 0.001). The most commonly reported complications were minor vascular complications (4.6%) and transient phrenic nerve paralysis (3.3%). CONCLUSIONS: First-generation VGLB ablation demonstrated high acute isolation rates, reasonable procedure times and low complication rates. Long-term freedom from AF was 78.8% for paroxysmal AF and 65.3% for persistent AF, performing PVI only.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Veias Pulmonares/cirurgia , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Recidiva
16.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37910101

RESUMO

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Assuntos
Fibrilação Atrial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adolescente , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Estudos de Coortes , Fatores Sexuais , Resultado do Tratamento
17.
Europace ; 14(3): 437-44, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22102630

RESUMO

AIMS: Current fluoroscopic and 3D image-guided treatment of atrial fibrillation (AF) by radiofrequency ablation is characterized by a substantial amount of X-ray radiation. We investigated the potential of an asymmetric collimation technique to reduce dose. METHODS AND RESULTS: For 30 patients, referred for AF ablation, we determined the received fluoroscopy dose for various collimation scenarios: a single collimation window encompassing all veins as used in most labs (Sc 1), an optimal adjusted symmetric collimation window encompassing each two ipsilateral veins (Sc 2) or each individual vein (Sc 3) and an optimal asymmetric collimation window encompassing each two ipsilateral veins (Sc 4) or each individual vein (Sc 5). Twenty patients were studied retrospectively and 10 were studied prospectively. Total fluoroscopy effective dose for all collimation strategies amounted to 45 ± 31 mSv for a single collimation field (Sc 1), 36 ± 25 mSv (Sc 2), and 24 ± 14 mSv (Sc 3) for a symmetrically adjusted collimation window and 15 ± 10 (Sc 4) and 5 ± 3 mSv (Sc 5) for an asymmetrically adjusted collimation approach. Validation of symmetric (Sc 2) and asymmetric (Sc 4) collimation in 10 patients confirmed the retrospective analysis. CONCLUSIONS: Implementation and effective application of an optimal asymmetric collimation approach would yield an average three- to nine-fold reduction of fluoroscopy dose during AF ablation procedures. This reduction exceeds what has been previously reported by implementing an electromagnetic catheter tracking approach. Furthermore, it can be easily integrated in the clinical workflow with limited additional one-time cost. Manufacturers of imaging systems should consider its implementation a priority, and physicians should adopt it in their workflow.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Fluoroscopia/métodos , Veias Pulmonares/cirurgia , Doses de Radiação , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
18.
Acta Cardiol ; 67(6): 641-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23393934

RESUMO

PURPOSE: Worldwide, the number of transvenous extractions of chronically implanted endocardial leads rapidly increases. Despite great technical progress, lead extraction remains a challenging procedure with possible life-threatening complications. We present the success and complication rate of lead extractions in the University Hospitals Leuven, and investigated a possible relationship between the use of powered sheaths and lead type, fixation, location and implantation time. METHODS: We present an observational retrospective cohort study of 157 patients admitted to the University Hospitals Leuven between January 2005 and December 2010, for the transvenous removal of a total of 259 endocardial leads. RESULTS: Complete procedural success was achieved in 92% of patients (n = 144). Of all leads, 94% (n = 243) were completely extracted. Only in 5 patients (3%), lead extraction failed. Leads that could not be removed were significantly older (134.1 +/- 90.7 months vs. 73.1 +/- 61.9 months; P = 0.02). In the other 8 patients the leads were partially removed with a remaining major retained lead fragment in 2 and a minor fragment in 6 patients. Major procedural complication rate was 2.5% (n = 4). There were no procedure-related deaths. Powered sheaths were used significantly more for the extraction of defibrillator leads (51%) (vs. pacing leads (33%; P = 0.015)) and right ventricular located leads (43%) (vs. other location (28%; P = 0.011)). However, when comparing the need of powered sheaths for the extraction of right ventricular defibrillator leads vs. right ventricular pacing leads, only a trend to higher use was noticed (51 vs. 39%; P = 0.146). Powered sheath use was not related to fixation type. Leads that required the use of a powered sheath were implanted significantly longer (112 +/- 69.5 months vs. 41.7 +/- 33.7 months; P = 0.001). CONCLUSIONS: Chronically implanted endocardial leads can be transvenously extracted in a high number of cases and with a low risk of procedural complications. Powered sheaths proved to be a helpful tool to extract leads that could not be removed by manual traction. Powered sheaths are necessary for leads with longer implantation duration and are more often used for the extraction of defibrillator leads.


Assuntos
Bloqueio Atrioventricular/terapia , Cateterismo Periférico/métodos , Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
19.
Europace ; 13(10): 1386-93, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21646230

RESUMO

AIMS: Endurance sports activities have been associated with the development of atrial fibrillation (AF). Pulmonary vein isolation (PVI) by means of radiofrequency catheter ablation has been established as an effective treatment for AF. The aim of the present study was to analyse the efficacy of AF ablation in athletes. METHODS AND RESULTS: We compared procedural outcome and median term follow-up in 94 consecutive athletes (>3 h of sports/week for ≥ 10 years or ≥ 1500 h lifetime) who underwent PVI (94% men, 51 ± 8 years, 87% paroxysmal AF, left atrial (LA) diameter 40 ± 8 mm, mean follow-up 41 months), and 41 contemporary controls. Sixty-three per cent of athletes performed endurance sports (running, cycling, swimming, and rowing). Documented focal induction of AF and failed treatment with ≥ 1 anti-arrhythmic drug were pre-requisites for selection of ablation treatment. Patients with long-standing persistent or permanent AF or an LA diameter ≥ 55 mm were not considered for ablation. Median lifetime cumulative hours of sports was 8638 (4175-13 688) in athletes vs. 450 (280-600) in controls (P < 0.001). Other baseline characteristics except for gender (94 vs. 66% men, respectively, P < 0.001) were comparable between both groups, as was the total number of ablation procedures per patient (1.2 ± 0.5, P = 0.62). Survival analysis showed similar AF recurrence rate after a first ablation for controls and endurance athletes, though non-endurance athletes had a significantly higher AF recurrence rate (48 vs. 46 vs. 34% freedom from AF at 3 year follow-up after a single ablation, P= 0.04). Final outcome after all ablations was similar (87 vs. 84 vs. 85% freedom from AF at 3-year follow-up, P = 0.88). No other independent predictor for AF recurrence was identified. CONCLUSION: In patients with documented focal induction of non-permanent AF and absence of structural heart disease, PVI is as effective in endurance athletes as in other patients.


Assuntos
Atletas , Fibrilação Atrial/cirurgia , Ablação por Cateter , Adulto , Fibrilação Atrial/mortalidade , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resistência Física , Veias Pulmonares/cirurgia , Taxa de Sobrevida , Resultado do Tratamento
20.
Acta Cardiol ; 76(9): 993-1000, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33432875

RESUMO

BACKGROUND: The benefit of de novo cardiac resynchronisation therapy (CRT) implantation in selected patients with heart failure is well known. The number of upgrade procedures is increasing but data on clinical response and outcome are less well documented as compared to de novo implantation. OBJECTIVES: To investigate the efficacy and outcome of CRT upgrade procedures in patients with existing cardiac implantable electronic devices (CIEDs). METHODS: Baseline characteristics, change in New York Heart Association (NYHA) functional class, echocardiographic parameters, life-threatening ventricular tachyarrhythmias, all-cause mortality and mode of death were evaluated in CRT patients with the comparison between de novo and upgrade CRT procedures. RESULTS: About 410 patients (CRT upgrade/de novo CRT, n = 97/313) were followed for 63.5 ± 38.1 months. Upgrade patients were older (75.5 ± 8.1 vs 69.9 ± 10.7 years; p < 0.001), had more often an ischaemic cause of heart failure (58.8% vs 45.4%; p = 0.021), a higher NYHA functional class (p = 0.004) and a higher comorbidity burden. Improvement in left ventricular ejection fraction (LVEF) was higher in the de novo CRT group (8.4 ± 9.9 vs 11.0 ± 10.3%; p = 0.035). Clinical response was similar between both groups (60.5 vs 62.5%; p = 0.793), as was mortality at 1 year (8.2 vs 5.8%; p = 0.351) and at last follow-up (33.0 vs 28.8%; p = 0.447). The proportion of cardiovascular related deaths was similar between both groups (46.9% vs 38.9%; p = 0.531). CONCLUSIONS: Patients with CRT upgrade procedures have similar symptomatic improvements, as well as 1 year and long-term outcome as compared to patients with de novo CRT implantation.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa