RESUMO
BACKGROUND: Long-term intensive training induces physiological, morphological, and functional adaption of the athlete's heart. PURPOSE: To evaluate the development of athlete's heart during a mid-term follow-up of competitive athletes using cardiac magnetic resonance (CMR). MATERIAL AND METHODS: Eighteen competitive long-distance runners and triathletes (age 43 ± 13 years, 3 women) were prospectively examined in a longitudinal follow-up study 5.05 ± 0.6 years after baseline. CMR at 1.5-T was performed for functional and late gadolinium enhancement (LGE) imaging. Left ventricular (LV) and right ventricular (RV) end-diastolic volume (LVEDV, RVEDV) as well as ejection fraction (LVEF, RVEF), LV myocardial mass (LVMM), and atrial sizes were determined and compared to baseline in matched pairs statistics for paired difference. RESULTS: LVEDV (197 ± 38 mL vs. 196 ± 38 mL, paired difference -0.9 mL, P = 0.7) and LVEF (62 ± 7% vs. 62 ± 5%, paired difference 0.1%, P = 0.9) did not change during the follow-up period, whereas LVMM increased significantly (149 ± 31 g vs.164 ± 32 g, paired difference 14 g, P < 0.0001). RVEDV significantly increased from 221 ± 47 mL at baseline to 230 ± 52 mL (paired difference 10 mL, P = 0.0033). RVEF decreased from baseline 57 ± 8% to 53 ± 7% (paired difference -3%, P = 0.0234). Left atrial size showed no significant changes (24 ± 5 cm2 vs. 25 ± 6 cm2, paired difference 0.5 cm2, P = 0.17) and right atrial size increased significantly (30 ± 5 cm2 vs. 32 ± 4 cm2, paired difference 2 cm2, P = 0.0054). CONCLUSION: This study supports the theory of ongoing remodeling in an athlete's heart. Predominantly the right heart can further enlarge in a mid-term period. This response seems not linearly dependent on a steady, decreased, or increased training volume.
Assuntos
Atletas , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Função Ventricular/fisiologia , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Gadolínio , Humanos , Aumento da Imagem/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto JovemRESUMO
PURPOSE: To introduce a dual-contrast fast spin-echo (dcFSE) sequence for signal decay mapping of myocardial edema. MATERIALS AND METHODS: After consultation with the Institutional Review Board, 22 acute myocardial infarction (MI) patients were examined with magnetic resonance imaging (MRI) at 1.5T 2 days after revascularization. Edema was evaluated in 16 myocardial segments with an exponential fit for signal decay time (SDT) in dcFSE mapping and T2 signal intensity ratio for single-contrast FSE. Myocardial viability was evaluated in late gadolinium enhancement (LGE). A control group of 10 volunteers was examined for edema imaging. SDT was compared in segment groups: 1) with LGE in MI, 2) penumbra, 3) remote from LGE, 4) controls. Groups 1/3 and 3/4 were tested on difference. Three phantoms providing similar T2 but different T1 relaxation times (low, intermediate, high) were examined with dcFSE and multicontrast spin echo sequence as a reference. RESULTS: The SDT/T2 ratio for segment groups was 1) 82msec/1.7 in segments with LGE; 2) 65msec/1.6 for penumbra, 3) 62msec/1.7 for remote segments, and 4) 50msec/1.6 in controls. In dcFSE group 1/3 (P < 0.0001) and in group 3/4 (P = 0.0002) SDT was significantly different. In single-contrast FSE the T2 ratio was not significantly different for both tests: 1/3 P = 0.1889; 3/4 P = 0.8879. T2 -overestimation of dcFSE was 23% in low, 29% in intermediate, and 35% in highly T1 contaminated phantoms. CONCLUSION: dcFSE signal decay edema mapping is feasible in volunteers and patients. DcFSE SDT is superior to T2 ratio for detection of high-grade and diffuse myocardial edema. J. Magn. Reson. Imaging 2016;44:186-193.
Assuntos
Algoritmos , Técnicas de Imagem Cardíaca/métodos , Edema Cardíaco/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de SpinRESUMO
BACKGROUND: To determine morphological and functional cardiovascular magnetic resonance (CMR) patterns in histopathologically confirmed myocardial involvement in patients with systemic sclerosis (SSc). METHODS: Twenty patients (6 females; mean age 41 ± 11 years) with histopathologically proven cardiac involvement in SSc in the years 2008-2016 were retrospectively evaluated. Morphological, functional and late gadolinium enhancement (LGE) images were acquired in standard angulations at 1.5 T CMR. Pathologies were categorized: 1) Pericardial effusion; 2) pathologic left (LV) or right ventricular (RV) contractility (hypokinesia, dyssynchrony, and diastolic restriction); 3) reduced left (LV-EF) and right ventricular ejection fraction (RV-EF); 4) fibrosis and/or inflammation (positive LGE); 5) RV dilatation. 95 % confidence intervals (CI) were calculated for appearance of pathologic EF and RV dilatation. RESULTS: Seven patients (35 %) had positive CMR findings in three categories, 9 patients (45 %) in four categories and 4 patients (20 %) in five categories. The distribution of pathologic findings was: minimal pericardial effusion in 7 patients (35 %), moderate pericardial effusion >5 mm in nine patients (45 %); abnormal LV or RV contractility in 19 patients (95 %), reduced LV or RV function in 14 patients (70 %; 95 % CI: 51-88 %), pathologic LGE in all patients, RV dilatation in 6 patients (30 %; 95 % CI: 15-54 %). CONCLUSIONS: CMR diagnosis of myocardial involvement in SSc requires increased attention to subtle findings. Pathologic findings in at least three of five categories indicate myocardial involvement in SSc.
Assuntos
Cardiomiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Escleroderma Sistêmico/complicações , Adulto , Biópsia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Compostos Organometálicos/administração & dosagem , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/patologia , Derrame Pericárdico/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Escleroderma Sistêmico/diagnóstico , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/patologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda , Função Ventricular DireitaRESUMO
Direct stem cell therapies for functionally impaired tissue require a sufficient number of cells in the target region and a method for verifying the fate of the cells in the subsequent time course. In vivo MRI of iron labeled mesenchymal stem cells has been suggested to comply with these requirements. The study was conducted to evaluate proliferation, migration, differentiation and adhesion effects as well as the obtained iron load of an iron labeling strategy for mesenchymal stem cells. After injection into the porcine urethral sphincter, the labeled cells were monitored for up to six months using MRI. Mesenchymal stem cells were labeled with ferucarbotran (60/100/200 µg/mL) and ferumoxide (200 µg/mL) for the analysis of migration and viability. Phantom MR measurements were made to evaluate effects of iron labeling. For short and long term studies, the iron labeled cells were injected into the porcine urethral sphincter and monitored by MRI. High resolution anatomical images of the porcine urethral sphincter were applied for detection of the iron particles with a turbo-spin-echo sequence and a gradient-echo sequence with multiple TE values. The MR images were then compared with histological staining. The analysis of cell function after iron labeling showed no effects on proliferation or differentiation of the cells. Although the adherence increases with higher iron dose, the ability to migrate decreases as a presumed effect of iron labeling. The iron labeled mesenchymal stem cells were detectable in vivo in MRI and histological staining even six months after injection. Labeling with iron particles and subsequent evaluation with highly resolved three dimensional data acquisition allows sensitive tracking of cells injected into the porcine urethral sphincter for several months without substantial biological effects on mesenchymal stem cells.
Assuntos
Rastreamento de Células/métodos , Ferro , Imageamento por Ressonância Magnética/métodos , Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais/citologia , Uretra/citologia , Animais , Movimento Celular/fisiologia , Sobrevivência Celular/fisiologia , Meios de Contraste , Endoscopia/métodos , Células-Tronco Mesenquimais/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos , Suínos , Uretra/cirurgiaRESUMO
OBJECTIVE: This large-scale randomized study aimed to show the noninferiority in terms of diagnostic performance of gadoterate meglumine-enhanced versus gadobutrol-enhanced 3-T MR angiography (MRA) using digital subtraction angiography (DSA) as the reference standard in patients with peripheral arterial occlusive disease (PAOD). SUBJECTS AND METHODS: In this prospective international randomized double-blind phase IV trial, 189 patients were enrolled. Of them, 156 could be included in the per-protocol population for on-site assessments and 154 for off-site readings. Subjects underwent peripheral MRA, after injection of 0.1 mmol/kg of either gadoterate meglumine or gadobutrol, and DSA within 30 days. The diagnostic accuracy was evaluated and compared using a noninferiority analysis. Secondary endpoints included sensitivity, specificity, diagnostic confidence, contrast-to-noise ratio, and signal-to-noise ratio evaluations. RESULTS: The percentage agreement between MRA and DSA for stenosis detection was similar for on-site readings for both groups (mean ± SD, 80.6% ± 16.1% with gadoterate meglumine vs 77.1% ± 19.6% with gadobutrol; 3.5% difference), and the same was true for off-site readings (73.9% ± 16.9% with gadoterate meglumine vs 75.1% ± 13.8% with gadobutrol; 1.1% difference). The noninferiority of gadoterate meglumine to gadobutrol was shown for both on- and off-site readings. Sensitivity in detecting significant stenosis (> 50%) was 72.3% for gadoterate meglumine versus 70.6% for gadobutrol, whereas specificity (92.6% vs 92.3%), diagnostic confidence (87.0% vs 86.0%), signal-to-noise ratio (165.5 vs 161.0), and contrast-to-noise ratio (159.5 vs 155.3) did not differ statistically significantly between the two groups. CONCLUSION: Gadoterate meglumine was found to be not inferior to gadobutrol in terms of diagnostic performance in patients with PAOD undergoing 3-T contrast-enhanced MRA. No statistically significant differences were detected between the two MRA groups.
Assuntos
Arteriopatias Oclusivas/diagnóstico , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Doença Arterial Periférica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/métodos , Meios de Contraste , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: Newborns and small infants have shallow breathing. OBJECTIVE: To suggest criteria for when respiratory gating is necessary during cardiac MRI in newborns and infants. MATERIALS AND METHODS: One-hundred ten data sets of newborns and infants with (n = 92, mean age: 1.9 ± 1.7 [SD] years) and without (n = 18, mean age: 1.6 ± 1.8 [SD] years) navigator gating were analysed retrospectively. The respiratory motion of the right hemidiaphragm was recorded and correlated to age, weight, body surface area and qualitative image quality on a 4-point score. Quantitative image quality assessment was performed (sharpness of the delineation of the ventricular septal wall) as well as a matched-pair comparison between navigator-gated and non-gated data sets. RESULTS: No significant differences were found in overall image quality or in the sharpness of the ventricular septal wall between gated and non-gated scans. A navigator acceptance of >80% was frequently found in patients ages <12 months, body surface area <0.40 m(2), body weight <10 kg and a size of <80 cm. CONCLUSION: Sequences without respiratory gating may be used in newborns and small infants, in particular if age <12 months, body surface area <0.40 m(2), body weight <10 kg and height <80 cm.
Assuntos
Cardiopatias Congênitas/diagnóstico , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Miocárdio/patologia , Artefatos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Respiração , Estudos RetrospectivosRESUMO
OBJECTIVE: To directly compare the diagnostic performance of targeted MRI-guided biopsy (MR-GB) and systematic transrectal ultrasound-guided biopsy (TRUS-GB). METHODS: Thirty-five patients with at least one negative TRUS-GB, persistently elevated or rising prostate-specific antigen and a lesion suspicious for prostate cancer (PC) on multiparametric MRI (mpMRI) scored by using the Prostate Imaging Reporting and Data System (PI-RADS) were included. A median of three targeted biopsies per lesion were obtained and systematic TRUS-GB was performed subsequently by an independent urologist without knowledge of the MRI findings. Definite pathology reports were analyzed for anatomical location and criteria of clinical significance. RESULTS: The tumor detection rate was significantly higher with MR-GB compared with TRUS-GB (16/35, 46% and 8/35, 23%, respectively, p < 0.05). MR-GB detected PC in all patients with positive TRUS-GB. All tumors detected by MR-GB exhibited at least one criterion of clinical significance. PC lesions showed a significantly higher PI-RADS sum score compared with benign lesions. CONCLUSIONS: MR-GB is more effective compared with TRUS-GB in detecting clinically significant PC in men after previous negative TRUS-GB. PI-RADS scores give additional information and could be part of the decision-making process when considering retrial biopsy. Additional systematic biopsy can be omitted in patients undergoing targeted MR-GB.
Assuntos
Biópsia/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Bases de Dados Factuais , Reações Falso-Negativas , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Índice de Gravidade de Doença , UltrassonografiaAssuntos
Consumo de Álcool na Faculdade , Consumo de Bebidas Alcoólicas/efeitos adversos , Cerveja/efeitos adversos , Consumo Excessivo de Bebidas Alcoólicas/complicações , Esôfago , Corpos Estranhos/etiologia , Estudantes , Consumo de Bebidas Alcoólicas/sangue , Consumo Excessivo de Bebidas Alcoólicas/sangue , Concentração Alcoólica no Sangue , Esofagoscopia , Esôfago/diagnóstico por imagem , Corpos Estranhos/diagnóstico , Corpos Estranhos/terapia , Humanos , Masculino , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: As dose-escalation in prostate cancer radiotherapy improves cure rates, a major concern is rectal toxicity. We prospectively assessed an innovative approach of hydrogel injection between prostate and rectum to reduce the radiation dose to the rectum and thus side effects in dose-escalated prostate radiotherapy. METHODS: Acute toxicity and planning parameters were prospectively evaluated in patients with T1-2 N0 M0 prostate cancer receiving dose-escalated radiotherapy after injection of a hydrogel spacer. Before and after hydrogel injection, we performed MRI scans for anatomical assessment of rectal separation. Radiotherapy was planned and administered to 78 Gy in 39 fractions. RESULTS: From eleven patients scheduled for spacer injection the procedure could be performed in ten. In one patient hydrodissection of the Denonvillier space was not possible. Radiation treatment planning showed low rectal doses despite dose-escalation to the target. In accordance with this, acute rectal toxicity was mild without grade 2 events and there was complete resolution within four to twelve weeks. CONCLUSIONS: This prospective study suggests that hydrogel injection is feasible and may prevent rectal toxicity in dose-escalated radiotherapy of prostate cancer. Further evaluation is necessary including the definition of patients who might benefit from this approach. TRIAL REGISTRATION: German Clinical Trials Register DRKS00003273.
Assuntos
Adenocarcinoma/radioterapia , Fracionamento da Dose de Radiação , Hidrogel de Polietilenoglicol-Dimetacrilato/administração & dosagem , Neoplasias da Próstata/radioterapia , Lesões por Radiação/prevenção & controle , Radioterapia de Intensidade Modulada , Reto/efeitos da radiação , Adenocarcinoma/sangue , Adenocarcinoma/patologia , Idoso , Estudos de Viabilidade , Alemanha , Humanos , Injeções , Calicreínas/sangue , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Estudos Prospectivos , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Fatores de Tempo , Resultado do TratamentoRESUMO
"Athlete's heart" is characterized by an increase in ventricular chamber sizes and myocardial mass (MM), and is mainly observed in endurance athletes. At present, it remains unclear whether cardiac adaptations in long-distance runners differ from those in triathletes. Twenty male triathletes (mean age 38.7 ± 6.2 years) and 20 male marathon runners (mean age 44.1 ± 7.9) underwent cardiac magnetic resonance imaging to calculate left and right ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and MM. Late-enhancement (LE) imaging was used to exclude structural alterations or myocardial scarring. EDV, ESV, SV, and EF for the left and right ventricles, as well as MM, did not differ between long-distance runners and triathletes, although the weekly training volume was significantly higher in triathletes (17.05 vs 9.95 h/week, P < 0.0001). There was a significant correlation between weekly training volume and right and left EDV, right and left ESV as well as MM within the study group. Myocardial LE was absent in all athletes. Highly trained male long-distance runners and triathletes have comparable cardiac parameters. However, the extent of physical training seems to be associated with the degree of cardiac adaptation in endurance athletes. The absence of LE supports the idea that athlete's heart is a nonpathological adaptation of the cardiovascular system.
Assuntos
Ciclismo , Cardiomegalia Induzida por Exercícios , Imageamento por Ressonância Magnética , Resistência Física , Corrida , Natação , Função Ventricular Esquerda , Função Ventricular Direita , Adaptação Fisiológica , Adulto , Meios de Contraste , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Condicionamento Físico Humano , Valor Preditivo dos Testes , Volume SistólicoRESUMO
OBJECTIVE: Exact determination of localization and extent of peritoneal carcinomatosis (PC) before peritonectomy and hyperthermic intraperitoneal chemotherapy (HIPEC) is crucial for the clinical outcome. Our study compares dynamic contrast enhanced 3D MRI (T1wDCE) and 18F-FDG PET/CT regarding diagnostic accuracy in correlation with surgical exploration (SE) and histological (HI) results. MATERIALS AND METHODS: 15 patients with PC were examined on a 1.5T MRI and 16 slice PET/CT. MRI: coronal T1wDCE covering the complete abdomen (0.15 mmol Gd-chelate/kg BW, 2000 mL mannitol solution p.o., 40 mg buscopan i.v.). PET-CT: contrast enhanced 16slice CT (120 mL ultravist 370 i.v., 1000 mL mannitol solution p.o., 40 mg buscopan i.v.), PET: 350 MBq 18-FDG i.v., 3 min acquisition time/bed, 60 min after tracer injektion). Assessment by two independent, experienced observers in correlation with results of SE and HI for each abdominal segment based on the peritoneal cancer index (PCI) proposed by Sugarbaker and co-authors. RESULTS: MRI and PET/CT provided reliable detection of PC. One patient had to be excluded from statistical analysis. In summary, 182 segments were assessed (13/patient, 14 patients, one patient excluded from statistical analysis). PC was found in 118 by MRI, 124 by PET/CT. 4 segments were classified false positive for MRI, 2 for PET/CT. False negative segments (MRI: 17, PET/CT: 9) did not result in irresectability. Positive predictive value for PC/segment was 97/98%, negative predictive value 73/84%, sensitivity 87/93%, specificity 92/96%, and diagnostic accuracy 88/94% (MRI/PET/CT). CONCLUSION: With high diagnostic accuracy for PC of both, MRI and PET/CT, PET/CT provides better diagnostic accuracy and especially better NPV.
Assuntos
Carcinoma/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Neoplasias Peritoneais/patologia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Carcinoma/diagnóstico por imagem , Carcinoma/cirurgia , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/cirurgia , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Compostos Radiofarmacêuticos , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To measure blood perfusion in extramedullary myeloma by contrast-enhanced sonography, correlate it with specific hematologic parameters, and determine their utility for local and systemic response monitoring. METHODS: Twenty-five consecutive patients (14 male and 11 female; median age, 68 years) with extramedullary myeloma were included. After intravenous administration of 2.4 mL of sulfur hexafluoride, extramedullary myeloma masses were examined for 60 seconds. All patients underwent contrast-enhanced sonography at baseline, and 15 were monitored additionally (3 weeks during therapy). Average peak perfusion, regional blood flow (RBF), and regional blood volume (RBV) were calculated. Baseline perfusion parameters were compared with short-term follow-up sonographic data and serologic biomarkers (M gradient). For validation of extramedullary myeloma and systemic myeloma, patients underwent midterm (<3 months) imaging and serologic diagnosis. RESULTS: Patients with baseline ß2-microglobulin (B2M) greater than 3.5 mg/L (n = 17) showed higher perfusion parameters compared with baseline B2M less than 3.5 mg/L (n = 8). At short-term follow-up, patients were classified by serologic criteria as responders (n = 9) and nonresponders (n = 6) and by sonographic criteria as responders (n = 10) and nonresponders (n = 5). In sonographic responders, mean peak, RBV, and RBF dropped from 59.13, 1446.09, and 71.52 (artificial units) at baseline to 29.30, 364.19, and 34.64 at follow-up (P < .05), whereas in nonresponders, perfusion parameters increased from 33.18, 789.82, and 36.92 at baseline to 51.14, 1491.06, and 65.34 at follow-up (P > .05). Prediction of a midterm course of systemic myeloma using serologic data yielded sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 0.66, 0.77, 0.66, and 0.77, whereas sonographic results (judged by RBV) yielded values of 0.66, 0.55, 0.5, and 0.71. Separate prediction of a local (extramedullary myeloma) response by sonography yielded sensitivity, specificity, PPV, and NPV of 0.8, 1.0, 1.0, and 0.71. CONCLUSIONS: Contrast-enhanced sonography is a valuable tool for short-term monitoring of the treatment response in extramedullary myeloma.
Assuntos
Antineoplásicos/uso terapêutico , Biomarcadores Tumorais/sangue , Mieloma Múltiplo/diagnóstico , Mieloma Múltiplo/tratamento farmacológico , Fosfolipídeos , Hexafluoreto de Enxofre , Ultrassonografia/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do TratamentoRESUMO
OBJECTIVE: In patients with peritoneal carcinomatosis (PC) accurate preoperative assessment is essential to determine indication and surgical procedure to ensure optimal outcome. Purpose of our study was to assess the diagnostic accuracy (DA) of multiphasic dynamic contrast-enhanced MRI to determine the extent of PC in correlation with surgical and histopathological findings. MATERIALS AND METHODS: 14 Patients with proven PC were examined on a 1.5T system before peritonectomy and hyperthermic intraperitoneal chemotherapy. Patient preparation included oral application of 2000 mL mannitol solution and 40 mg butylscopolaminiumbromid i.v. Coronal contrast-enhanced multiphasic dynamic T1w 3D gre sequences (T1W DCE) (0.15 mmol Gd-chelate/kg bw) covering the whole abdomen were acquired (TR 2.9 ms, TE 1.1 ms, resolution 2.0 × 2.0 × 1.8 mm, FOV 400 × 400 mm). MRI was assessed by two radiologists and correlated with surgical exploration (SE) and histopathology for each segment based on the peritoneal cancer index proposed by Sugarbaker et al. RESULTS: In total, 182 segments were evaluated. PC was found in 118/121 of 182 segments (reader 1/2) by MRI and in 131 segments by SE. In 4/7 segments MRI was false positive. False negative segments 17/17 in MRI did not result in irresectability. The positive predictive value for PC per segment of MRI was 97%/94%, the negative predictive value 73%/72%, the sensitivity 87%/87% and the specificity 92%/86%. The DA was 88%/87%. CONCLUSION: T1W DCE is an accurate and clinical valuable tool for the preoperative assessment of peritoneal tumor spread.
Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Peritoneais/diagnóstico , Neoplasias Peritoneais/cirurgia , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Peritoneais/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: The objective of our study was to assess the feasibility and diagnostic performance of time-resolved MR angiography (MRA) in the pretreatment evaluation of peripheral vascular malformations at 1.5 T. SUBJECTS AND METHODS: Twenty-two consecutive patients (15 women and seven men; mean age, 22.1 ± 12.1 years) who were known or suspected to have vascular malformations were studied using time-resolved MRA with interleaved stochastic trajectories and parallel acquisition followed by conventional MRA (n = 12). All studies were performed on a 1.5-T whole-body MR system. Image sets of time-resolved and conventional MRA were independently reviewed by two observers for image quality, level of confidence and presence, location, and classification of vascular malformations. The interobserver agreement was calculated using conventional MRA as the standard of reference. RESULTS: On the basis of time-resolved MRA, nine of the lesions were categorized as high-flow arteriovenous malformations (AVMs), the remaining 13 lesions were categorized as low-flow vascular malformations or hemangiomas. There was no significant difference in the image quality grading scores between the two observers for time-resolved MRA (p = 0.61) and conventional MRA (p = 0.54). The kappa coefficient revealed good agreement (κ = 0.76) between time-resolved MRA and conventional MRA. Both observers visualized fine vascular details with higher confidence in two patients on conventional MRA. The additional functional information regarding feeding artery and flow patterns provided by time-resolved MRA was confirmed by digital subtraction in all nine cases. CONCLUSION: Time-resolved MRA provided the temporal information needed for the appropriate classification of vascular malformations, enabling visualization of both the arterial feeders and draining veins. Furthermore, time-resolved MRA has the potential to be used as an initial and screening diagnostic tool obviating conventional MRA to categorize these lesions and determine their extent to correctly guide treatment.
Assuntos
Malformações Arteriovenosas/diagnóstico , Hemangioma/diagnóstico , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Neoplasias Vasculares/diagnóstico , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estatísticas não Paramétricas , Adulto JovemRESUMO
PURPOSE: The evaluation process of potential living kidney donors focusses on renal anatomy and split renal function. This study aimed to evaluate a magnetic resonance imaging (MRI)-based approach for simultaneous evaluation of both and its impact on clinical decision making. METHOD: Over a 3-year period, 65 potential living kidney donors were consecutively enrolled. The MRI protocol was extended by MR-nephrography to measure split renal function. Standard DTPA-scintigraphy was used for functional comparison. RESULTS: Split renal function showed no systematic bias between the two methods (mean difference 0.3%, p = 0.08). Both methods would have yielded the same clinical decision for donor nephrectomy in 75% of the patients. In 25 % of the patients, one method indicated a relevant side difference while the other did not, and a different clinical decision could have been made based on split renal function alone. CONCLUSIONS: MRI proved eligible for comprehensive living kidney donor evaluation and non-inferior to scintigraphy for determining split renal function. In clinical decision making, these two methods would have resulted in the same side for donor nephrectomy in a large proportion of potential donors. Whether MRN will be implemented in clinical practice depends on transplant centre infrastructure and policy.
Assuntos
Transplante de Rim , Humanos , Rim/diagnóstico por imagem , Rim/fisiologia , Testes de Função Renal , Doadores Vivos , Imageamento por Ressonância Magnética , NefrectomiaRESUMO
OBJECTIVES: To longitudinally assess the value of cardiac functional and viability imaging as a supplement to MR angiography in patients with atherosclerotic disease. METHODS: Cardiac MRI was performed in 195 consecutive patients with symptomatic peripheral arterial disease. Of these, 186 patients were followed for 22 +/- 5 months for the presence of cardiac events (cardiac death, acute coronary syndrome and hospitalisation as a result of congestive heart failure). RESULTS: Myocardial viability imaging showed a high prevalence of known (n = 31) and occult myocardial infarctions (MI) (n = 26). Cardiac events occurred more often in patients with reduced ventricular function (ejection fraction (EF) less than 40%, cardiac event in 4/8 patients; EF 40-55%, cardiac event in 10/40 patients; EF greater than 55%, cardiac event in 15/138 patients) as well as in patients with occult MI (8/25 patients) and known MI (11/30 patients). In patients with normal function, the detection of a previous MI was of high relevance to prognosis. CONCLUSIONS: Both reduced EF and the presence of MI influence patients' prognoses. Performing cardiac MRI in this patient population may influence further patient management including intensified risk factor intervention.
Assuntos
Aterosclerose/diagnóstico , Aterosclerose/epidemiologia , Cardiopatias/diagnóstico , Cardiopatias/epidemiologia , Angiografia por Ressonância Magnética/estatística & dados numéricos , Idoso , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Sobrevivência de TecidosRESUMO
OBJECTIVE: Stress perfusion magnetic resonance imaging (MSPMRI) is an established technique for the assessment of myocardial perfusion. Shortcomings at 1.5 T are low signal to noise ratio (SNR) and contrast to noise ratio (CNR). One approach to overcome these shortcomings is to increase field strength and contrast concentration. The aim of our study was to investigate the diagnostic capability of high resolution MSPMRI at 3-T field strength using a 1 M contrast agent. MATERIAL AND METHODS: Fifty-seven patients (62.3 +/- 11.0 years) with symptoms of coronary artery disease (CAD) were examined at 3 T. MMRSPI was assessed using a 2D saturation recovery gradient echo (SR GRE) sequence in short axis orientation (TR 1.9 ms, TE 1.0 ms, flip 12 degrees , 0.1 mmol gadobutrol/kg body weight (bw), 140 microg adenosine/kg bw/min). Perfusion images were assessed visually and semiquantitatively (upslope, peak signal intensity (SI), and myocardial perfusion reserve index (MPRI)). Standard of reference was invasive coronary angiography. RESULTS: Stress-induced hypoperfusion was found in 43 patients. Sensitivity for hemodynamically relevant CAD (stenoses greater than 70%) was 95%/98%, specificity 80%/87%, diagnostic accuracy 91%/95% (reader 1/reader 2). The MPRI was significantly lower in hypoperfused myocardium (1.3 +/- 0.2) compared with normal myocardium (2.6 +/- 0.7). CONCLUSION: High resolution MMRSPI at 3 T using 1 M contrast agent under daily routine conditions provides reliable detection of stress-induced myocardial hypoperfusion with higher diagnostic accuracy than 1.5-T conditions.
Assuntos
Adenosina , Doença da Artéria Coronariana/diagnóstico , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Imagem de Perfusão/métodos , Disfunção Ventricular Esquerda/diagnóstico , Meios de Contraste , Doença da Artéria Coronariana/complicações , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologiaRESUMO
PURPOSE: To compare true positive and false negative results of myocardial edema mapping in two methods. Myocardial edema may be difficult to detect on cardiac MRI. MATERIALS AND METHODS: 76 patients (age 59â±â11 years, 15 female) with acute myocardial infarction (MI) and 10 healthy volunteers were prospectively included in this single-center study. 1.5âT cardiac MRI was performed in patients 2.5 days after revascularization (median) for edema mapping: Steady State Free Precession (SSFP) mapping sequence with T2-preparation pulses (T2prep); and dual-contrast Fast Spin-Echo (dcFSE) signal decay edema mapping. Late gadolinium enhancement (LGE) was used as the reference for expected edema in acute MI. RESULTS: 311 myocardial segments in patients were acutely infarcted with mean T2 73âms for T2prep SSFP vs. 87âms for dcFSE edema mapping. In healthy volunteers the mean T2 was 56âms for T2prep SSFP vs. 50âms for dcFSE edema mapping. Receiver operating characteristic (ROC) curve for T2prep SSFP show area under the curve (AUC) 0.962, pâ<â0.0001, Youden index J 0.8266, associated criterion >â60âms, sensitivity 94â%, specificity 89â%. dcFSE ROC AUC 0.979, pâ<â0.0001, J 0.9219, associated criterion >â64âms, sensitivity 93â%, specificity 99â%. CONCLUSION: Both edema mapping methods indicate high-grade edema with high sensitivity. Nevertheless, edema in acute infarction may be focally underestimated in both mapping methods. KEY POINTS: · Sensitivity for edema detection is high for both methods.. · Edema may be focally underestimated by T2prep SSFP edema mapping and dcFSE mapping.. CITATION FORMAT: · Krumm P, Martirosian P, Rath D etâal. Performance of two Methods for Cardiac MRI Edema Mapping: Dual-Contrast Fast Spin-Echo and T2 Prepared Balanced Steady State Free Precession. Fortschr Röntgenstr 2020; 192: 669â-â677.
Assuntos
Edema Cardíaco/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Reações Falso-Negativas , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e EspecificidadeRESUMO
The study was approved by the local ethics committee, and informed consent was provided by all participants prior to the examination. The aim of the study was to assess the feasibility of whole-body three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiography with parallel imaging in the phase- and section-encoding directions (ie, integrated parallel acquisition technique [iPAT(2); Siemens, Erlangen, Germany]) for all anatomic imaging stations in combination with a single injection of contrast material. Whole-body contrast-enhanced MR angiography was performed in 23 patients at 3.0 T. Images were evaluated by two independent observers for quality on a four-point scale (where a score of 1 indicated poor image quality and a score of 4, excellent image quality); signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for representative vessel regions in each station. Mean image quality scores were 3.13 +/- 1.15 (standard deviation) and 3.17 +/- 1.14 for observers 1 and 2, respectively (kappa = 0.81). Signal intensity measurements revealed mean SNR values between 36.2 +/- 8.0 and 56.2 +/- 17.7 and mean CNR values between 29.0 +/- 7.4 and 48.2 +/- 15.7. The data suggest that contrast-enhanced MR angiography with iPAT(2) is feasible for whole-body applications and allows acquisition of 3D data sets with adequate spatial resolution within short measurement times, facilitating a single injection of contrast material.