Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607938

RESUMO

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Sistema de Registros , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Suíça/epidemiologia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos
2.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37387689

RESUMO

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
3.
Stroke ; 54(10): 2542-2551, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37548011

RESUMO

BACKGROUND: Atrial fibrillation is a major risk factor for stroke and silent brain infarcts. We studied whether a multimodal approach offers additional insights to the CHA2DS2-VASc score in predicting stroke or new brain infarcts on magnetic resonance imaging (MRI) over a 2-year follow-up. METHODS: Swiss-AF is a prospective, multicenter cohort study of patients with known atrial fibrillation. We included patients with available brain MRI both at enrollment and 2 years later. The dates of the baseline and follow-up visits ranged from March 2014 to November 2020. The primary outcome was assessed 2 years after baseline and was defined as a composite of clinically identified stroke or any new brain infarct on the 2-year MRI. We compared a multivariable logistic regression model including prespecified clinical, biomarker, and baseline MRI variables to the CHA2DS2-VASc score. RESULTS: We included 1232 patients, 89.8% of them taking oral anticoagulants. The primary outcome occurred in 78 patients (6.3%). The following baseline variables were included in the final multivariate model and were significantly associated with the primary outcome: white matter lesion volume in milliliters (adjusted odds ratio [aOR], 1.91 [95% CI, 1.45-2.56]), NT-proBNP (N-terminal pro-B-type natriuretic peptide; aOR, 1.75 [95% CI, 1.20-2.63]), GDF-15 (growth differentiation factor-15; aOR, 1.68 [95% CI, 1.11-2.53]), serum creatinine (aOR, 1.50 [95% CI, 1.02-2.22]), IL (interleukin)-6 (aOR, 1.37 [95% CI, 1.00-1.86]), and hFABP (heart-type fatty acid-binding protein; aOR, 0.48 [95% CI, 0.31-0.73]). Overall performance and discrimination of the new model was superior to that of the CHA2DS2-VASc score (C statistic, 0.82 [95% CI, 0.77-0.87] versus 0.64 [95% CI, 0.58-0.70]). CONCLUSIONS: In patients with atrial fibrillation, a model incorporating white matter lesion volume on baseline MRI and selected blood markers yielded new insights on residual stroke risk despite a high proportion of patients on oral anticoagulants. This may be relevant to develop further preventive measures.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Estudos de Coortes , Estudos Prospectivos , Medição de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Biomarcadores , Anticoagulantes/uso terapêutico
4.
Value Health ; 26(12): 1721-1729, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37741443

RESUMO

OBJECTIVES: Randomized controlled trials of pulmonary vein isolation (PVI) for treating atrial fibrillation (AF) have proven the procedure's efficacy. Studies assessing its empirical cost-effectiveness outside randomized trial settings are lacking. We aimed to evaluate the effectiveness and cost-effectiveness of PVI versus medical therapy for AF. METHODS: We followed a target trial approach using the Swiss-AF cohort, a prospective observational cohort study that enrolled patients with AF between 2014 and 2017. Resource utilization and cost information were collected through claims data. Quality of life was measured with EQ-5D-3L utilities. We estimated incremental cost-effectiveness ratios (ICERs) from the perspective of the Swiss statutory health insurance system. RESULTS: Patients undergoing PVI compared with medical therapy had a 5-year overall survival advantage with a hazard ratio of 0.75 (95% CI 0.46-1.21; P = .69) and a 19.8% SD improvement in quality of life (95% CI 15.5-22.9; P < .001), at an incremental cost of 29 604 Swiss francs (CHF) (95% CI 16 354-42 855; P < .001). The estimated ICER was CHF 158 612 per quality-adjusted life-year (QALY) gained within a 5-year time horizon. Assuming similar health effects and costs over 5 additional years changed the ICER to CHF 82 195 per QALY gained. Results were robust to the sensitivity analyses performed. CONCLUSIONS: Our results show that PVI might be a cost-effective intervention within the Swiss healthcare context in a 10-year time horizon, but unlikely to be so at 5 years, if a willingness-to-pay threshold of CHF 100 000 per QALY gained is assumed. Given data availability, we find target trial designs are a valuable tool for assessing the cost-effectiveness of healthcare interventions outside of randomized controlled trial settings.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Qualidade de Vida , Veias Pulmonares/cirurgia , Estudos Prospectivos , Anos de Vida Ajustados por Qualidade de Vida
5.
Europace ; 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37165671

RESUMO

BACKGROUND: Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS: The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS: Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION: When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters.

6.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38036293

RESUMO

AIMS: Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS: One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION: Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37944133

RESUMO

AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS: Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2-7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69-73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74-83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78-89, one study) and PFA (87%, 95%CI 84-90, 2 studies). CONCLUSION: We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fatores de Tempo , Resultado do Tratamento , Recidiva
8.
Europace ; 25(2): 487-495, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36355748

RESUMO

AIMS: Assess prevalence, risk factors, and management of patients with intra-cardiac thrombus referred for scar-related ventricular tachycardia (VT) ablation. METHODS AND RESULTS: Consecutive VT ablation referrals between January 2015 and December 2019 were reviewed (n = 618). Patients referred for de novo, scar-related VT ablation who underwent pre-procedure cardiac computed tomography (cCT) were included. We included 401 patients [61 ± 14 years; 364 male; left ventricular ejection fraction (LVEF) 40 ± 13%]; 45 patients (11%) had cardiac thrombi on cCT at 49 sites [29 LV; eight left atrial appendage (LAA); eight right ventricle (RV); four right atrial appendage]. Nine patients had pulmonary emboli. Overall predictors of cardiac thrombus included LV aneurysm [odds ratio (OR): 6.6, 95%, confidence interval (CI): 3.1-14.3], LVEF < 40% (OR: 3.3, CI: 1.5-7.3), altered RV ejection fraction (OR: 2.3, CI: 1.1-4.6), and electrical storm (OR: 2.9, CI: 1.4-6.1). Thrombus location-specific analysis identified LV aneurysm (OR: 10.9, CI: 4.3-27.7) and LVEF < 40% (OR: 9.6, CI: 2.6-35.8) as predictors of LV thrombus and arrhythmogenic right ventricular cardiomyopathy (OR: 10.6, CI: 1.2-98.4) as a predictor for RV thrombus. Left atrial appendage thrombi exclusively occurred in patients with atrial fibrillation. Ventricular tachycardia ablation was finally performed in 363 including 7 (16%) patients with thrombus but refractory electrical storm. These seven patients had tailored ablation with no embolic complications. Only one (0.3%) ablation-related embolic event occurred in the entire cohort. CONCLUSION: Cardiac thrombus can be identified in 11% of patients referred for scar-related VT ablation. These findings underscore the importance of systematic thrombus screening to minimize embolic risk.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Trombose , Humanos , Masculino , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Volume Sistólico , Prevalência , Cicatriz , Função Ventricular Esquerda , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia , Cardiopatias/complicações , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Ablação por Cateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento
9.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37314197

RESUMO

AIMS: Atrial remodelling, defined as a change in atrial structure, promotes atrial fibrillation (AF). Bone morphogenetic protein 10 (BMP10) is an atrial-specific biomarker released to blood during atrial development and structural changes. We aimed to validate whether BMP10 is associated with AF recurrence after catheter ablation (CA) in a large cohort of patients. METHODS AND RESULTS: We measured baseline BMP10 plasma concentrations in AF patients who underwent a first elective CA in the prospective Swiss-AF-PVI cohort study. The primary outcome was AF recurrence lasting longer than 30 s during a follow-up of 12 months. We constructed multivariable Cox proportional hazard models to determine the association of BMP10 and AF recurrence. A total of 1112 patients with AF (age 61 ± 10 years, 74% male, 60% paroxysmal AF) was included in our analysis. During 12 months of follow-up, 374 patients (34%) experienced AF recurrence. The probability for AF recurrence increased with increasing BMP10 concentration. In an unadjusted Cox proportional hazard model, a per-unit increase in log-transformed BMP10 was associated with a hazard ratio (HR) of 2.28 (95% CI 1.43; 3.62, P < 0.001) for AF recurrence. After multivariable adjustment, the HR of BMP10 for AF recurrence was 1.98 (95% CI 1.14; 3.42, P = 0.01), and there was a linear trend across BMP10 quartiles (P = 0.02 for linear trend). CONCLUSION: The novel atrial-specific biomarker BMP10 was strongly associated with AF recurrence in patients undergoing CA for AF. CLINICALTRIALS.GOV IDENTIFIER: NCT03718364; https://clinicaltrials.gov/ct2/show/NCT03718364.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos de Coortes , Estudos Prospectivos , Proteínas Morfogenéticas Ósseas , Ablação por Cateter/efeitos adversos
10.
Eur Heart J ; 43(22): 2127-2135, 2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35171989

RESUMO

AIMS: We aimed to investigate the association of clinically overt and silent brain lesions with cognitive function in atrial fibrillation (AF) patients. METHODS AND RESULTS: We enrolled 1227 AF patients in a prospective, multicentre cohort study (Swiss-AF). Patients underwent standardized brain magnetic resonance imaging (MRI) at baseline and after 2 years. We quantified new small non-cortical infarcts (SNCIs) and large non-cortical or cortical infarcts (LNCCIs), white matter lesions (WML), and microbleeds (Mb). Clinically, silent infarcts were defined as new SNCI/LNCCI on follow-up MRI in patients without a clinical stroke or transient ischaemic attack (TIA) during follow-up. Cognition was assessed using validated tests. The mean age was 71 years, 26.1% were females, and 89.9% were anticoagulated. Twenty-eight patients (2.3%) experienced a stroke/TIA during 2 years of follow-up. Of the 68 (5.5%) patients with ≥1 SNCI/LNCCI, 60 (88.2%) were anticoagulated at baseline and 58 (85.3%) had a silent infarct. Patients with brain infarcts had a larger decline in cognition [median (interquartile range)] changes in Cognitive Construct score [-0.12 (-0.22; -0.07)] than patients without new brain infarcts [0.07 (-0.09; 0.25)]. New WML or Mb were not associated with cognitive decline. CONCLUSION: In a contemporary cohort of AF patients, 5.5% had a new brain infarct on MRI after 2 years. The majority of these infarcts was clinically silent and occurred in anticoagulated patients. Clinically, overt and silent brain infarcts had a similar impact on cognitive decline. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02105844, https://clinicaltrials.gov/ct2/show/NCT02105844.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Infarto Encefálico , Cognição , Estudos de Coortes , Feminino , Humanos , Ataque Isquêmico Transitório/complicações , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/patologia
11.
J Cardiovasc Electrophysiol ; 33(8): 1687-1693, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637606

RESUMO

INTRODUCTION: Systematic and quantitative descriptions of vein of Marshall (VOM)-induced tissue ablation are lacking. We sought to characterize the distribution of low voltage observed in the left atrium (LA) after VOM ethanol infusion. METHODS AND RESULTS: The distribution of ethanol-induced low voltage was evaluated by comparing high-density maps performed before and after VOM ethanol infusion in 114 patients referred for atrial fibrillation ablation. The two most frequently impacted segments were the inferior portion of the ridge (82.5%) and the first half of the mitral isthmus (pulmonary vein side) (92.1%). Low-voltage absence in these typical areas resulted from inadvertent ethanol infusion in the left atrial appendage vein (n = 3), initial VOM dissection (n = 3), or a "no branches" VOM morphology (n = 1). Visible anastomosis of the VOM with roof or posterior veins more frequently resulted in low-voltage extension beyond typical areas, toward the entire left antrum (19.0% vs. 1.9%, p = .0045) or the posterior LA (39.7% vs. 3.8%, p < .001) but with a limited positive predictive value ranging from 29.4% to 43.5%. Ethanol-induced low voltage covered a median LA surface of 3.6% (1.9%-5.0%) and did not exceed 8% of the LA surface in 90% of patients. CONCLUSION: VOM ethanol infusion typically locates at the inferior ridge and the adjacent half of the mitral isthmus. Low-voltage extensions can be anticipated but not guaranteed by the presence of visible anastomosis of the VOM with roof or posterior veins.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Etanol/efeitos adversos , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia
12.
J Cardiovasc Electrophysiol ; 33(5): 908-916, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35274776

RESUMO

INTRODUCTION: Due to changes in esophageal position, preoperative assessment of the esophageal location may not mitigate the risk of esophageal injury in catheter ablation for atrial fibrillation (AF). This study aimed to assess esophageal motion and its impact on AF ablation strategies. METHODS AND RESULTS: Ninety-seven AF patients underwent two computed tomography (CT) scans. The area at risk of esophageal injury (AAR) was defined as the left atrial surface ≤3 mm from the esophagus. On CT1, ablation lines were drawn blinded to the esophageal location to create three ablation sets: individual pulmonary vein isolation (PVI), wide antral circumferential ablation (WACA), and WACA with linear ablation (WACA + L). Thereafter, ablation lines for WACA and WACA + L were personalized to avoid the AAR. Rigid registration was performed to align CT1 onto CT2, and the relationship between ablation lines and the AAR on CT2 was analyzed. The esophagus moved by 3.6 [2.7 to 5.5] mm. The AAR on CT2 was 8.6 ± 3.3 cm2 , with 77% overlapping that on CT1. High body mass index was associated with the AAR mismatch (standardized ß 0.382, p < .001). Without personalization, AARs on ablation lines for individual PVI, WACA, and WACA + L were 0 [0-0.4], 0.8 [0.5-1.2], and 1.7 [1.2-2.0] cm2 . Despite the esophageal position change, the personalization of ablation lines for WACA and WACA + L reduced the AAR on lines to 0 [0-0.5] and 0.7 [0.3-1.0] cm2 (p < .001 for both). CONCLUSION: The personalization of ablation lines based on a preoperative CT reduced ablation to the AAR despite changes in esophageal position.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago/lesões , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 33(6): 1116-1124, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35347799

RESUMO

INTRODUCTION: The optimal strategy after a failed ablation for persistent atrial fibrillation (perAF) is unknown. This study evaluated the value of an anatomically guided strategy using a systematic set of linear lesions with adjunctive ethanol infusion into the vein of Marshall (Et-VOM) in patients referred for second perAF ablation procedures. METHODS AND RESULTS: Patients with perAF who underwent a second procedure were grouped according to the two strategies. The first strategy was an anatomically guided approach using systematic linear ablation with adjunctive Et-VOM, with bidirectional blocks at the posterior mitral isthmus (MI), roof, and cavotricuspid isthmus (CTI) as the procedural endpoint (Group I). The second one was an electrophysiology-guided strategy, with atrial tachyarrhythmia termination as the procedural endpoint (Group II). Arrhythmia behavior during the procedure guided the ablation strategy. Groups I and II consisted of 96 patients (65 ± 9 years; 71 men) and 102 patients (63 ± 10 years; 83 men), respectively. Baseline characteristics were comparable. In Group I, Et-VOM was successfully performed in 91/96 (95%), and procedural endpoint (bidirectional block across all three anatomical lines) was achieved in 89/96 (93%). In Group II, procedural endpoint (atrial tachyarrhythmia termination) was achieved in 80/102 (78%). One-year follow-up demonstrated Group I (21/96 [22%]) experienced less recurrence compared to Group II (38/102 [37%], Log-rank p = .01). This was driven by lower AT recurrence in Group I (Group I: 10/96 [10%] vs. Group II: 29/102 [28%]; p = .002). CONCLUSION: Anatomically guided strategy with adjunctive Et-VOM is superior to an electrophysiology-guided strategy for second procedures in patients with perAF at 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrofisiologia Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Etanol/efeitos adversos , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Taquicardia , Resultado do Tratamento
14.
Rev Cardiovasc Med ; 23(1): 14, 2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35092206

RESUMO

Evidence on sex differences in the pathophysiology and interventional treatment of ventricular arrhythmia in ischemic (ICM) or non-ischemic cardiomyopathies (NICM) is limited. However, women have different etiologies and types of structural heart disease due to sex differences in genetics, proteomics and sex hormones. These differences may influence ventricular electrophysiological parameters and may require different treatment strategies. Considering that women were consistently under-represented in all randomized-controlled trials on VT ablation, the applicability of the study results to female patients is not known. In this article, we review the current knowledge and gaps in evidence about sex differences in the epidemiology, pathophysiology and catheter ablation in patients with ventricular arrhythmias.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto , Caracteres Sexuais , Taquicardia Ventricular/etiologia , Resultado do Tratamento
15.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35727739

RESUMO

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
16.
J Cardiovasc Electrophysiol ; 32(8): 2216-2224, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34223662

RESUMO

INTRODUCTION: Ultrahigh-density mapping for ventricular tachycardia (VT) is increasingly used. However, manual annotation of local abnormal ventricular activities (LAVAs) is challenging in this setting. Therefore, we assessed the accuracy of the automatic annotation of LAVAs with the Lumipoint algorithm of the Rhythmia system (Boston Scientific). METHODS AND RESULTS: One hundred consecutive patients undergoing catheter ablation of scar-related VT were studied. Areas with LAVAs and ablation sites were manually annotated during the procedure and compared with automatically annotated areas using the Lumipoint features for detecting late potentials (LP), fragmented potentials (FP), and double potentials (DP). The accuracy of each automatic annotation feature was assessed by re-evaluating local potentials within automatically annotated areas. Automatically annotated areas matched with manually annotated areas in 64 cases (64%), identified an area with LAVAs missed during manual annotation in 15 cases (15%), and did not highlight areas identified with manual annotation in 18 cases (18%). Automatic FP annotation accurately detected LAVAs regardless of the cardiac rhythm or scar location; automatic LP annotation accurately detected LAVAs in sinus rhythm, but was affected by the scar location during ventricular pacing; automatic DP annotation was not affected by the mapping rhythm, but its accuracy was suboptimal when the scar was located on the right ventricle or epicardium. CONCLUSION: The Lumipoint algorithm was as/more accurate than manual annotation in 79% of patients. FP annotation detected LAVAs most accurately regardless of mapping rhythm and scar location. The accuracy of LP and DP annotations varied depending on mapping rhythm or scar location.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia
17.
J Cardiovasc Electrophysiol ; 32(9): 2451-2461, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34314087

RESUMO

INTRODUCTION: Human atria comprise distinct layers. One layer can bypass another, and lead to a downstream centrifugal propagation at their interface. We sought to characterize anatomical substrates, electrophysiological properties, and ablation outcomes of "pseudo-focal" atrial tachycardias (ATs), defined as macroreentrant ATs mimicking focal ATs. METHODS AND RESULTS: We retrospectively analyzed left atrial ATs showing centrifugal propagation with postpacing intervals (PPIs) after entrainment pacing suggestive of a macroreentrant mechanism. A total of 22 patients had pseudo-focal ATs consisting of 15 perimitral and 7 roof-dependent flutters. A low-voltage area was consistently found at the collision site and colocalized with distinct anatomical structures like the: (1) coronary sinus-great cardiac vein bundle (27%), (2) vein of Marshall bundle (18%), (3) Bachmann bundle (27%), (4) septopulmonary bundle (18%), and (5) fossa ovalis (9%). The mean missing tachycardia cycle length (TCL) was 65 ± 31 ms (22%) on the endocardial activation map. PPI was 0 [0-15] ms and 0 [0-21] ms longer than TCL at the breakthrough site and the opposite site, respectively. While feasible in 21 pseudo-focal ATs (95%), termination was better achieved by blocking the anatomical isthmus than ablating the breakthrough site [20/21 (95%) vs. 1/5 (20%); p < .001]. CONCLUSION: Perimitral and roof-dependent flutters with centrifugal propagation are favored by a low-voltage area located at well-identified anatomical structures. Comprehensive entrainment pacing maneuvers are crucial to distinguish pseudo-focal ATs from true focal ATs. Blocking the anatomical isthmus is a better therapeutic option than ablating the breakthrough site.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Humanos , Estudos Retrospectivos , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 32(3): 772-781, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33428312

RESUMO

BACKGROUND: Determining the etiology of syncope is challenging in Brugada syndrome (BrS) patients. Implantable cardioverter defibrillator placement is recommended in BrS patients who are presumed to have arrhythmic syncope. However, arrhythmic syncope in BrS patients can occur in the setting of atrioventricular block (AVB), which should be managed by cardiac pacing. The clinical characteristics of BrS patients with high-risk AVB remain unknown. METHODS: This study included 223 BrS patients with a history of syncope from two centers. The clinical characteristics of patients with high-risk AVB (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB) were investigated. RESULTS: During the 99 ± 78 months of follow-up, we identified six BrS patients (2.7%) with high-risk AVB. Three of the six patients (50%) with AVB presented with syncope associated with prodromes or specific triggers. Four patients (67%) were found to have paroxysmal third-degree AVB during the initial evaluation for BrS and syncope, while two patients developed third-degree AVB during the follow-up period. The incidence of first-degree AVB was significantly higher in AVB patients than in non-AVB patients (83% vs. 15%; p = .0005). There was no significant difference in the incidence of ventricular fibrillation between AVB and non-AVB patients (AVB [17%], non-AVB [12%]; p = .56). CONCLUSION: High-risk AVB can occur in BrS patients with various clinical presentations. Although rare, the incidence is worth considering, especially in BrS patients with first-degree AVB.


Assuntos
Bloqueio Atrioventricular , Síndrome de Brugada , Desfibriladores Implantáveis , Bloqueio Atrioventricular/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Humanos , Síncope/diagnóstico , Síncope/epidemiologia
19.
Europace ; 23(11): 1767-1776, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34240134

RESUMO

AIMS: Pulsed field ablation (PFA), a non-thermal ablative modality, may show different effects on the myocardial tissue compared to thermal ablation. Thus, this study aimed to compare the left atrial (LA) structural and mechanical characteristics after PFA vs. thermal ablation. METHODS AND RESULTS: Cardiac magnetic resonance was performed pre-ablation, acutely (<3 h), and 3 months post-ablation in 41 patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein (PV) isolation with PFA (n = 18) or thermal ablation (n = 23, 16 radiofrequency ablations, 7 cryoablations). Late gadolinium enhancement (LGE), T2-weighted, and cine images were analysed. In the acute stage, LGE volume was 60% larger after PFA vs. thermal ablation (P < 0.001), and oedema on T2 imaging was 20% smaller (P = 0.002). Tissue changes were more homogeneous after PFA than after thermal ablation, with no sign of microvascular damage or intramural haemorrhage. In the chronic stage, the majority of acute LGE had disappeared after PFA, whereas most LGE persisted after thermal ablation. The maximum strain on PV antra, the LA expansion index, and LA active emptying fraction declined acutely after both PFA and thermal ablation but recovered at the chronic stage only with PFA. CONCLUSION: Pulsed field ablation induces large acute LGE without microvascular damage or intramural haemorrhage. Most LGE lesions disappear in the chronic stage, suggesting a specific reparative process involving less chronic fibrosis. This process may contribute to a preserved tissue compliance and LA reservoir and booster pump functions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética
20.
Europace ; 23(7): 1052-1062, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33564832

RESUMO

AIMS: An incomplete understanding of the mechanism of atrial tachycardia (AT) is a major determinant of ablation failure. We systematically evaluated the mechanisms of AT using ultra-high-resolution mapping in a large cohort of patients. METHODS AND RESULTS: We included 107 consecutive patients (mean age: 65.7 ± 9.2 years, males: 81 patients) with documented endocardial gap-related AT after left atrial ablation for persistent atrial fibrillation (AF). We analysed the mechanism of 134 AT (94 macro-re-entries and 40 localized re-entries) using high-resolution activation mapping in combination with high-density voltage and entrainment mapping. Voltage in the conducting channels may be extremely low, even <0.1 mV (0.14 ± 0.095 mV, 51 of 134 AT, 41%), and almost always <0.5 mV (0.03-0.5 mV, 133 of 134 AT, 99.3%). The use of multipolar Orion, HDGrid, and Pentaray catheters improved our accuracy in delineating ultra-low-voltage areas critical for maintenance of the circuit of endocardial gap-related AT. Conventional ablation catheters often do not detect any signal (noise level) even using adequate contact force, and only multipolar catheters of small electrodes and shorter interelectrode space can detect clear fractionated low-amplitude and high frequency signals, critical for re-entry maintenance. We performed a diagnosis in 112 out of 134 AT (83.6%) using only activation mapping and in 134 out of 134 AT (100%) using the combination of activation and entrainment mapping. CONCLUSION: High-resolution activation mapping in combination with high-density voltage and entrainment mapping is the ideal strategy to delineate the critical part of the circuit in endocardial gap-related re-entrant AT after AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa