Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 37(11): 2194-2203, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37316432

RESUMO

Transcatheter edge-to-edge repair (TEER) of the mitral valve is a complex procedure requiring continuous image guidance with 2-dimensional and 3-dimensional transesophageal echocardiography. In this context, the role of the echocardiographer is of paramount importance. Training in interventional echocardiography for procedures such as TEER requires comprehending the complicated workflow of the hybrid operating room and advanced imaging skills that go beyond traditional echocardiography training to guide the procedure. Despite TEER being more commonly performed, the training structure for interventional echocardiographers is lagging, with many practitioners not having any formal training in image guidance for this procedure. In this context, novel training strategies must be developed to increase exposure and aid training. In this review, the authors present a step-wise approach to training for image guidance during TEER of the mitral valve. The authors have deconstructed this complex procedure into modular components and have incremental stages of training based on different steps of the procedure. At each step, trainees must demonstrate proficiency before advancing to the next step, thus ensuring a more structured approach to attaining proficiency in this complex procedure.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 98(2): 403-406, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33595150

RESUMO

Structural deterioration of transcatheter heart valve (THV) has been previously described. With the expansion of transcatheter aortic valve replacement (TAVR) indications toward treating lower risk patients with longer life expectancy, there will be increased necessity of managing the patients with THV dysfunction including those at risk for coronary obstruction or sinus sequestration. Coronary access also remains a challenge in such cases with THV dysfunction undergoing valve-in-transcatheter heart valve (ViTHV) TAVR. A unique and first reported case of THV deterioration treated with Sapien 3 ViTHV-TAVR inside a 31 mm CoreValve bioprosthesis along with left coronary leaflet laceration using the BASILICA technique has been presented.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
BMC Geriatr ; 20(1): 38, 2020 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-32013890

RESUMO

BACKGROUND: Current guidelines recommend considering life expectancy before aortic valve replacement (AVR). We compared the performance of a general mortality index, the Lee index, to a frailty index. METHODS: We conducted a prospective cohort study of 246 older adults undergoing surgical (SAVR) or transcatheter aortic valve replacement (TAVR) at a single academic medical center. We compared performance of the Lee index to a deficit accumulation frailty index (FI). Logistic regression was used to assess the association of Lee index or FI with poor outcome, defined as death or functional decline with severe symptoms at 12 months. Discrimination was assessed using C-statistics. RESULTS: In the overall cohort, 44 experienced poor outcome (31 deaths, 13 functional decline with severe symptoms). The risk of poor outcome by Lee index quartiles was 6.8% (reference), 17.9% (odds ratio [OR], 3.0; 95% confidence interval, [0.9-10.2]), 20.0% (OR 3.4; [1.0-11.4]), and 34.0% (OR 7.1; [2.2-22.6]) (p-for-trend = 0.001). Risk of poor outcome by FI quartiles was 3.6% (reference), 10.3% (OR 3.1; [0.6-15.8]), 25.0% (OR 8.8; [1.9-41.0]), and 37.3% (OR 15.8; [3.5-71.1]) (p-for-trend< 0.001). The Lee index predicted the risk of poor outcome in the SAVR cohort Lee index (quartiles 1-4: 2.1, 4.0, 15.4, and 20.0%; p-for-trend = 0.04), but not in the TAVR cohort (quartiles 1-4: 27.3, 29.0, 21.3, 35.4%; p-for-trend = 0.42). In contrast, the FI did not predict the risk of poor outcome well in the SAVR cohort (quartiles 1-4: 2.3, 4.4, 15.8, and 0%; p-for-trend = 0.24), however in the TAVR cohort (quartiles 1-4: 9.1, 14.3, 29.7, and 40.7%; p-for-trend = 0.004). Compared to the Lee index, an FI demonstrated higher C-statistics in the overall (Lee index versus FI: 0.680 versus 0.735; p = 0.03) and TAVR (0.560 versus 0.644; p = 0.03) cohorts, but not SAVR cohort (0.724 versus 0.766; p = 0.09). CONCLUSIONS: While a general mortality index Lee index predicted death or functional decline with severe symptoms at 12 months well among SAVR patients, the FI derived from a multi-domain geriatric assessment better informs risk-stratification for high-risk TAVR patients.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Atividades Cotidianas , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Fragilidade/diagnóstico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
4.
Circulation ; 128(11 Suppl 1): S136-43, 2013 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-24030397

RESUMO

BACKGROUND: Moderate alcohol consumption is known to be cardioprotective compared with either heavy drinking or complete abstinence. We assessed the hypothesis that ethanol supplementation would improve myocardial function in the setting of chronic ischemia. METHODS AND RESULTS: Sixteen male Yorkshire swine underwent placement of an ameroid constrictor into the left circumflex artery to induce chronic myocardial ischemia. Postoperatively, animals were supplemented with either 90 mL of ethanol (EtOH) daily (50%/V, EtOH) or 80 g of sucrose of equal caloric value (SUC), serving as controls. Seven weeks after ameroid placement, arteriolar density (1.74 ± 0.210% versus 3.11 ± 0.368% area of arterioles per low-powered field in sucrose (SUC) versus EtOH; P=0.004), myocardial perfusion (ratio of blood flow to the at-risk myocardium compared with the normal ventricle during demand pacing was 0.585 ± 0.107 versus 1.08 ± 0.138 for SUC versus EtOH; P=0.014), and microvascular reactivity were significantly increased in ethanol-treated animals compared with controls in the at-risk myocardium. Analysis of vascular endothelial growth factor and NOTCH pathway signaling suggested proneovascular and proliferative activity in the ischemic area. The average peak blood alcohol level in the treatment group was 40 ± 4 mg/dL, consistent with levels of moderate drinking in humans. CONCLUSIONS: Ethanol supplementation increased arteriolar density and significantly improved myocardial perfusion and endothelium-dependent vasorelaxation in chronically ischemic myocardium. These findings suggest that, at moderate doses, ethanol directly promotes vasculogenesis and improves microvascular function, resulting in significant improvements in myocardial perfusion in the setting of chronic ischemia.


Assuntos
Circulação Coronária/fisiologia , Vasos Coronários/fisiologia , Etanol/uso terapêutico , Isquemia Miocárdica/tratamento farmacológico , Reperfusão Miocárdica/métodos , Animais , Arteríolas/efeitos dos fármacos , Arteríolas/fisiologia , Circulação Coronária/efeitos dos fármacos , Vasos Coronários/efeitos dos fármacos , Etanol/farmacologia , Masculino , Isquemia Miocárdica/fisiopatologia , Miocárdio , Suínos , Porco Miniatura
5.
Am J Cardiol ; 214: 1-7, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
6.
Circulation ; 126(11 Suppl 1): S65-72, 2012 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-22965995

RESUMO

BACKGROUND: Moderate consumption of alcohol, particularly red wine, has been shown to decrease cardiac risk. We used a hypercholesterolemic swine model of chronic ischemia to examine the effects of 2 alcoholic beverages on the heart. METHODS AND RESULTS: Yorkshire swine fed a high-cholesterol diet underwent left circumflex ameroid constrictor placement to induce chronic ischemia at 8 weeks of age. One group (HCC, n=9) continued on the diet alone, the second (HCW, n=8) was supplemented with red wine (pinot noir, 12.5% alcohol, 375 mL daily), and the third (HCV, n=9) was supplemented with vodka (40% alcohol, 112 mL daily). After 7 weeks, cardiac function was measured, and ischemic myocardium was harvested for analysis of perfusion, myocardial fibrosis, vessel function, protein expression, oxidative stress, and capillary density. Platelet function was measured by aggregometry. Perfusion to the ischemic territory as measured by microsphere injection was significantly increased in both HCW and HCV compared with HCC at rest, but in only the HCW group under ventricular pacing. Microvessel relaxation response to adenosine 5'-diphosphate was improved in the HCW group alone as was regional contractility in the ischemic territory, although myocardial fibrosis was decreased in both HCW and HCV. Expression of proangiogenic proteins phospho-endothelial nitric oxide synthase and vascular endothelial growth factor was increased in both HCW and HCV, whereas phospho-mammalian target of rapamycin was increased only in the HCV group. Expression of Sirt-1 and downstream antioxidant phospho-FoxO1 was increased only in the HCW group. Protein oxidative stress was decreased in the HCW group alone, whereas capillary density was increased only in the HCV group. There was no significant difference in platelet function between groups. CONCLUSION: Moderate consumption of red wine and vodka may reduce cardiovascular risk by improving collateral-dependent perfusion through different mechanisms. Red wine may offer increased cardioprotection related to its antioxidant properties.


Assuntos
Bebidas Alcoólicas , Circulação Colateral , Circulação Coronária , Hipercolesterolemia/terapia , Isquemia Miocárdica/terapia , Vinho , Animais , Estimulação Cardíaca Artificial , Vasos Coronários/patologia , Dieta Aterogênica , Modelos Animais de Doenças , Endotélio Vascular/fisiopatologia , Indução Enzimática , Etanol/sangue , Regulação da Expressão Gênica , Hemodinâmica , Hipercolesterolemia/complicações , Hipercolesterolemia/fisiopatologia , Masculino , Modelos Cardiovasculares , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Óxido Nítrico Sintase Tipo III/biossíntese , Óxido Nítrico Sintase Tipo III/genética , Estresse Oxidativo , Sus scrofa , Suínos , Serina-Treonina Quinases TOR/biossíntese , Serina-Treonina Quinases TOR/genética , Fator A de Crescimento do Endotélio Vascular/biossíntese , Fator A de Crescimento do Endotélio Vascular/genética
7.
Catheter Cardiovasc Interv ; 82(7): E915-8, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-21954145

RESUMO

Left ventricular (LV) pseudoaneurysm is a rare complication after myocardial infarction and cardiac surgery. Standard treatment remains surgical correction; however, percutaneous closure has been attempted in high risk surgical patients. We report a case of three dimensional echocardiography and cardiac CT defined LV pseudoaneurysm which was closed percutaneously using intracardiac echocardiography (ICE) and fluoroscopy guidance. Appropriate planning and guidance proved essential to the procedure with an excellent outcome. Percutaneous closure of LV pseudoaneurysms is safe and feasible in high risk surgical patients and with appropriate imaging modalities may be an alternative to surgical correction.


Assuntos
Falso Aneurisma/terapia , Cateterismo Cardíaco/métodos , Ecocardiografia , Aneurisma Cardíaco/terapia , Ventrículos do Coração/diagnóstico por imagem , Radiografia Intervencionista/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Falso Aneurisma/diagnóstico por imagem , Ecocardiografia Tridimensional , Fluoroscopia , Aneurisma Cardíaco/diagnóstico por imagem , Humanos , Masculino , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
Cardiovasc Revasc Med ; 47: 48-54, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36266154

RESUMO

We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Marca-Passo Artificial/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Am J Cardiol ; 208: 37-43, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812864

RESUMO

Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Fatores de Risco
10.
Circulation ; 123(1): 62-9, 2011 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-21173354

RESUMO

BACKGROUND: Cell therapy for myocardial infarction (MI) may be limited by poor cell survival and lack of transdifferentiation. We report a novel technique of implanting whole autologous myocardial tissue from preserved myocardial regions into infarcted regions. METHODS AND RESULTS: Fourteen rats were used to optimize cardiomyotissue size with peritoneal wall implantation (300 µm identified as optimal size). Thirty-nine pigs were used to investigate cardiomyotissue implantation in MI induced by left anterior descending balloon occlusion (10 animals died; male-to-female transplantation for tracking with in situ hybridization for Y chromosome, n=4 [2 donors and 2 MI animals]; acute MI implantation cohort at 1 hour, n=13; and healed MI implantation at 2 weeks, n=12). Assessment included echocardiography, magnetic resonance imaging, hemodynamics, triphenyltetrazolium chloride staining, and histological and molecular analyses. Tracking studies demonstrated viable implants with donor cells interspersed in the adjacent myocardium with gap junctions and desmosomes. In the acute MI cohort, treated animals compared with controls had improved perfusion by magnetic resonance imaging (1.2±0.01 versus 0.86±0.05; P<0.01), decreased MI size (magnetic resonance imaging: left ventricle, 2.2±0.5% versus 5.4±1.5%, P=0.04; triphenyltetrazolium chloride: anterior wall, 10.3±4.6% versus 28.9±5.8%, P<0.03), and improved contractility (dP/dt, 1235±215 versus 817±817; P<0.05). In the healed MI cohort, treated animals had less decline in ejection fraction between 2 and 4 week assessment (-3±4% versus -13±-4%; P<0.05), less decline in ±dP/dt, and smaller MI (triphenyltetrazolium chloride, 21±11% versus 3±8%; P=0.006) than control animals. Infarcts in the treated animals contained more mdr-1(+) cells and fewer c-kit(+) cells with a trend for decreased expression of matrix metalloproteinase-2 and increased expression of tissue inhibitor of metalloproteinase-2. CONCLUSION: Autologous cardiomyotissue implanted in an MI area remains viable, exhibits electromechanical coupling, decreases infarct size, and improves left ventricular function.


Assuntos
Septos Cardíacos/transplante , Infarto do Miocárdio/cirurgia , Miocárdio , Regeneração/fisiologia , Função Ventricular Esquerda/fisiologia , Animais , Feminino , Septos Cardíacos/fisiologia , Masculino , Infarto do Miocárdio/fisiopatologia , Distribuição Aleatória , Ratos , Suínos , Transplante de Tecidos/métodos , Transplante Autólogo
11.
Basic Res Cardiol ; 107(2): 243, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22231675

RESUMO

Ossabaw miniswine have been naturally selected to efficiently store large amounts of lipids offering them a survival advantage. Our goal was to evaluate the myocardial response to chronic ischemia of the Ossabaw consuming a hypercaloric, high-fat/cholesterol diet with and without metformin supplementation. At 6 weeks of age animals were fed either a regular diet (OC, n = 9), a hypercaloric high-fat/cholesterol diet (OHC, n = 9), or a hypercaloric high-fat/cholesterol diet supplemented with metformin (OHCM, n = 8). At 9 weeks, all animals underwent ameroid constrictor placement to the left circumflex coronary artery to simulate chronic ischemia. Seven weeks after ameroid placement, all animals underwent hemodynamic and functional measurements followed by cardiac harvest. Both OHC and OHCM animals developed significantly greater weight gain, total cholesterol, and LDL:HDL ratio compared to OC controls. Metformin administration reversed diet-induced hypertension and glucose intolerance. There were no differences in global and regional contractility, myocardial perfusion, capillary and arteriolar density, or total protein oxidation between groups. Myocardial protein expression of VEGF, PPAR-α, γ, and δ was significantly increased in the OHC and OHCM groups. Microvessel reactivity was improved in the OHC and OHCM groups compared to controls, and correlated with increased p-eNOS expression. Overfed Ossabaw miniswine develop several components of metabolic syndrome. However, impairments of myocardial function, neovascularization and perfusion were not present, and microvessel reactivity was paradoxically improved in hypercholesterolemic animals. The observed cardioprotection despite metabolic derangements may be due to lipid-dependant upregulation of the PPAR pathway which is anti-inflammatory and governs myocardial fatty acid metabolism.


Assuntos
Vasos Coronários/metabolismo , Hemodinâmica/fisiologia , Síndrome Metabólica/metabolismo , Isquemia Miocárdica/metabolismo , Animais , Circulação Colateral/fisiologia , Vasos Coronários/fisiopatologia , Dieta Hiperlipídica , Hemodinâmica/efeitos dos fármacos , Hipoglicemiantes/farmacologia , Síndrome Metabólica/patologia , Metformina/farmacologia , Isquemia Miocárdica/fisiopatologia , Suínos , Porco Miniatura
12.
Catheter Cardiovasc Interv ; 80(4): 657-60, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22488685

RESUMO

Inferior vena cava filters can provide lifesaving protections in patients with recurrent venous thromboembolic disease that are not candidates for anticoagulation. They are, however, associated with short- and long-term complications necessitating frequent follow-up. The authors report, in this article, a case of migration of Bird's Nest filter strut into the descending aorta and its percutaneous retrieval by snaring and capture. This case also underscores the trend to use retrievable filters to avoid longer-term complications.


Assuntos
Aorta Torácica/lesões , Remoção de Dispositivo , Procedimentos Endovasculares , Migração de Corpo Estranho/terapia , Falha de Prótese , Lesões do Sistema Vascular/terapia , Filtros de Veia Cava , Veia Cava Inferior , Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Desenho de Prótese , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Veia Cava Inferior/diagnóstico por imagem
13.
JACC Cardiovasc Interv ; 15(7): 728-738, 2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35393106

RESUMO

OBJECTIVES: This study sought to evaluate patient-centered metrics in intermediate-surgical-risk aortic stenosis patients enrolled in the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial treated with self-expanding transcatheter aortic valve replacement (TAVR) or surgery. BACKGROUND: Studies have shown TAVR to be an alternative to surgery in patients with severe symptomatic aortic stenosis but have focused on "hard endpoints," including all-cause mortality and stroke, rather than on comparative patient-centered metrics, such as functional status and symptom burden. METHODS: The study analyzed functional status (6-minute walk test [6MWT]) and symptom burden (Kansas City Cardiomyopathy Questionnaire) in 1,492 patients from the SURTAVI trial at baseline, 30 days, 1 year, and 2 years. Patients were categorized by baseline functional status into tertiles of slow, medium, and fast walkers. RESULTS: Patients with lowest capacity baseline functional status were commonly women, had higher Society of Thoracic Surgeons scores, and had more New York Heart Association functional class III or IV symptoms; reduced baseline functional status was associated with higher aortic valve- and heart failure-related hospitalization at 2 years. There was greater improvement in 6MWT distance in TAVR compared with surgery patients at 30 days (P < 0.001) and 1 year (P = 0.012), but at 2 years, both groups had similar improvement (P = 0.091). The percentage of patients with large improvement in 6MWT was greatest in patients categorized as slow walkers and lowest in fast walkers. Symptom burden improved after TAVR at 30 days and after both procedures at 1 and 2 years. CONCLUSIONS: In this substudy of patients from the SURTAVI trial, patients receiving TAVR demonstrated a more rapid improvement in functional status and symptom burden compared with patients undergoing surgery; however, both groups had similar improvements in long-term follow-up. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Estado Funcional , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Circulation ; 122(11 Suppl): S142-9, 2010 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-20837905

RESUMO

BACKGROUND: Resveratrol may provide protection against coronary artery disease. We hypothesized that supplemental resveratrol will improve cardiac perfusion in the ischemic territory of swine with hypercholesterolemia and chronic myocardial ischemia. METHODS AND RESULTS: Yorkshire swine were fed either a normal diet (control, n=7), a hypercholesterolemic diet (HCC, n=7), or a hypercholesterolemic diet with supplemental resveratrol (100 mg/kg/d orally, HCRV, n=7). Four weeks later, an ameroid constrictor was placed on the left circumflex artery. Animals underwent cardiac MRI and coronary angiography 7 weeks later before euthanasia and tissue harvest. Total cholesterol was lowered about 30% in HCRV animals (P<0.001). Regional wall motion analysis demonstrated a significant decrease in inferolateral function from baseline to 7 weeks in HCC swine (P=0.04). There was no significant change in regional function in HCRV swine from baseline to 7 weeks (P=0.32). Tissue blood flow during stress was 2.8-fold greater in HCRV swine when compared with HCC swine (P=0.04). Endothelium-dependent microvascular relaxation response to Substance P was diminished in HCC swine, which was rescued by resveratrol treatment (P=0.004). Capillary density (PECAM-1 staining) demonstrated fewer capillaries in both HCC and HCRV swine versus control swine (P=0.02). Immunoblot analysis demonstrated significantly greater expression in HCRV versus HCC swine of the following markers of angiogenesis: VEGF (P=0.002), peNOS (ser1177) (P=0.04), NFkB (P=0.004), and pAkt (thr308) (P=0.001). CONCLUSIONS: Supplemental resveratrol attenuates regional wall motion abnormalities, improves myocardial perfusion in the collateral dependent region, preserves endothelium-dependent coronary vessel function, and upregulates markers of angiogenesis associated with the VEGF signaling pathway.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Circulação Coronária/efeitos dos fármacos , Hipercolesterolemia/tratamento farmacológico , Microcirculação/efeitos dos fármacos , Isquemia Miocárdica/tratamento farmacológico , Estilbenos/farmacologia , Animais , Capilares/crescimento & desenvolvimento , Capilares/metabolismo , Capilares/patologia , Doença Crônica , Doença das Coronárias/metabolismo , Doença das Coronárias/patologia , Doença das Coronárias/fisiopatologia , Doença das Coronárias/prevenção & controle , Modelos Animais de Doenças , Feminino , Humanos , Hipercolesterolemia/metabolismo , Hipercolesterolemia/mortalidade , Hipercolesterolemia/fisiopatologia , Masculino , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/patologia , Isquemia Miocárdica/fisiopatologia , Miocárdio/metabolismo , Miocárdio/patologia , Neovascularização Fisiológica/efeitos dos fármacos , Perfusão , Resveratrol , Transdução de Sinais/efeitos dos fármacos , Suínos , Fator A de Crescimento do Endotélio Vascular/metabolismo
15.
Am J Cardiol ; 158: 104-111, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34465458

RESUMO

Durability of transcatheter heart valve (THV) is critical as the indication of transcatheter aortic valve implantation (TAVI) expands to patients with longer life-expectancy. We aimed to compare the durability of different THV systems (balloon-expandable [BE] and self-expandable [SE]) and surgical aortic valve replacement (SAVR) prosthesis. PUBMED and EMBASE were searched through February 2021 for randomized trials investigating parameters of valve durability after TAVI and/or SAVR in severe aortic stenosis. A network meta-analysis using random-effect model was performed. Synthesis was performed with 5-year follow-up data for echocardiographic outcomes and the longest available follow-up data for clinical outcomes. Ten trials with a total of 9,388 patients (BE-THV: 2,562; SE-THV: 2,863; SAVR: 3,963) were included. Follow-up ranged from 1 to 6 years. SE-THV demonstrated significantly larger effective orifice area, lower mean aortic valve gradient (AVG), and less increase in mean AVG at 5-year compared with BE-THV and SAVR. Structural valve deterioration (SVD) was less frequent in SE-THV compared with BE-THV and SAVR (HR 0.14, 95% CI 0.07 to 0.27; HR 0.34, 95% CI 0.24 to 0.47, respectively). Total moderate-severe aortic regurgitation and reintervention was more frequent in BE-THV (HR 4.21, 95% CI 2.40 to 7.39; HR 2.22, 95% CI 1.16 to 4.26, respectively), and SE-THV (HR 7.51, 95% CI 3.89 to 14.5; HR 2.86, 95% CI 1.59 to 5.13, respectively) compared with SAVR. In conclusion, TAVI with SE-THV demonstrated favorable forward-flow hemodynamics and lowest risk of SVD compared with BE-THV and SAVR at mid-term. However, both THV systems suffer an increased risk of AR and re-intervention, and long-term data from newer generation valves is warranted.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Falha de Prótese , Humanos
16.
Struct Heart ; 5(6): 591-595, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35340992

RESUMO

Background: We sought to compare characteristics and outcomes of structural heart disease (SHD) patients treated during the regional peak of the Coronavirus Disease 2019 (COVID-19) pandemic ("COVID era") compared with historical controls. During the COVID era, elective SHD procedures at Beth Israel Deaconess Medical Center were canceled but urgent cases were still performed. We enacted several practice changes in an effort to minimize complications, prevent COVID transmission, and decrease hospital stay during the pandemic. Methods: Baseline characteristics and outcomes were collected on all patients who underwent SHD procedures during the COVID era and compared with patients treated during the same time period in 2019. Results: Compared with SHD patients treated during 2019 (N = 259), those treated during the COVID era (N = 26) had higher left ventricular end diastolic pressure (LVEDP; 28 vs. 21 mmHg, p = 0.001), and were more likely New York Heart Association class IV (26.9% vs. 10.0%, p = 0.019), but had a lower rate of bleeding/vascular complications (0% vs. 16.2%, p = 0.013), a lower rate of permanent pacemaker implantation (0% vs. 17.4%, p = 0.019), and a greater proportion of patients were discharged on post-operative day 1 (POD#1; 68.2% vs. 22.2%, p < 0.001). Conclusion: Practice changes employed for patients treated during the COVID era were associated with fewer vascular complications, a greater proportion of patients discharged on POD#1, and a lower rate of pacemaker implantation despite more severe illness. As a result, we plan to continue these practices in the post-COVID era.

17.
JACC Cardiovasc Interv ; 14(9): 941-948, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33958168

RESUMO

OBJECTIVES: This study sought to determine the safety of the BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) procedure. BACKGROUND: Transcatheter aortic valve replacement causes coronary artery obstruction in 0.7% of cases, with 40% to 50% mortality. BASILICA is a procedure to prevent coronary obstruction. Safety and feasibility in a large patient cohort is lacking. METHODS: The international BASILICA registry was a retrospective, multicenter, real-world registry of patients at risk of coronary artery obstruction undergoing BASILICA and transcatheter aortic valve replacement. Valve Academic Research Consortium-2 definitions were used to adjudicate events. RESULTS: Between June 2017 and December 2020, 214 patients were included from 25 centers in North America and Europe; 72.8% had bioprosthetic aortic valves and 78.5% underwent solo BASILICA. Leaflet traversal was successful in 94.9% and leaflet laceration in 94.4%. Partial or complete coronary artery obstruction was seen in 4.7%. Procedure success, defined as successful BASILICA traversal and laceration without mortality, coronary obstruction, or emergency intervention, was achieved in 86.9%. Thirty-day mortality was 2.8% and stroke was 2.8%, with 0.5% disabling stroke. Thirty-day death and disabling stroke were seen in 3.4%. Valve Academic Research Consortium-2 composite safety was achieved in 82.8%. One-year survival was 83.9%. Outcomes were similar between solo and doppio BASILICA, between native and bioprosthetic valves, and with the use of cerebral embolic protection. CONCLUSIONS: BASILICA is safe, with low reported rates of stroke and death. BASILICA is feasible in the real-world setting, with a high procedure success rate and low rates of coronary artery obstruction.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
J Mol Cell Cardiol ; 49(6): 1022-30, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20826160

RESUMO

We investigated the role of neuropeptide Y (NPY), abundant in the myocardial sympathetic nervous system and endothelial cells, in angiogenesis during chronic myocardial ischemia. Adult male Yorkshire swine underwent ameroid constrictor placement on the proximal left circumflex coronary artery. After 3 weeks, an osmotic pump was placed to deliver either placebo (control, n=8) or NPY(3-36) (NPY, n=8) to the collateral dependent region. Five weeks after pump placement, after cardiac catheterization and hemodynamic assessment, the heart was harvested for analysis. NPY treated animals demonstrated increased mean arterial pressures and improved left ventricular function (+dP/dt). Cardiac catheterization demonstrated a significant increase in the blush score in the NPY group (p<0.001). Blood flow to the ischemic myocardium was not different between groups at rest or during ventricular pacing. Immunohistochemical double staining for CD-31 and smooth muscle actin demonstrated an increase in capillary and arteriole formation in NPY treated animals (p=0.02 and p<0.001). Immunoblotting showed a significant upregulation of DPPIV (p=0.009) and NPY receptors 1 (p=0.008), 2 (p=0.02) and 5 (p=0.03) in the NPY treated group. Additionally, there was significant upregulation of VEGF (p=0.04), eNOS (p=0.014), phospho-eNOS (ser1177) (p=0.02), and PDGF (p<0.001) in NPY treated group. The anti-angiogenic factors endostatin and angiostatin were significantly decreased in NPY treated animals (endostatin, p=0.03; angiostatin, p=0.04). Exogenous NPY(3-36) resulted in improved myocardial function and increased angiogenesis and arteriogenesis by stimulating growth factor, pro-angiogenic receptor upregulation, and decreasing anti-angiogenic expression, but did not increase blood flow to the ischemic myocardium. NPY may act as a good adjunct to primary agents of therapeutic angiogenesis.


Assuntos
Circulação Colateral/efeitos dos fármacos , Isquemia Miocárdica/fisiopatologia , Neuropeptídeo Y/farmacologia , Animais , Doença Crônica , Angiografia Coronária , Modelos Animais de Doenças , Testes de Função Cardíaca , Immunoblotting , Imuno-Histoquímica , Microvasos/efeitos dos fármacos , Microvasos/patologia , Microvasos/fisiopatologia , Modelos Biológicos , Isquemia Miocárdica/diagnóstico por imagem , Perfusão , Sus scrofa
19.
JACC Case Rep ; 2(12): 1852-1858, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34317066

RESUMO

Annular rupture is a rare catastrophic event during transcatheter aortic valve replacement, often life threatening and requiring emergent surgical repair. We describe, herein, a case of contained annular rupture successfully managed percutaneously with coiling and polymer injection. This is a novel technique to manage this complication. (Level of Difficulty: Advanced.).

20.
Am J Med ; 133(10): 1219-1222, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32199811

RESUMO

BACKGROUND: Cognitive impairment and frailty are highly prevalent in older adults undergoing transcatheter aortic valve replacement. This study aimed to investigate the relationship of cognitive impairment and frailty with functional recovery after transcatheter aortic valve replacement. METHODS: This was a single-center prospective cohort study of 142 patients who were ≥70 years old and underwent transcatheter aortic valve replacement for aortic stenosis. Prior to transcatheter aortic valve replacement, cognitive impairment was defined as Mini-Mental State Examination score <24 points (range: 0-30), and moderate-to-severe frailty was defined as a deficit-accumulation frailty index ≥0.35 (range: 0-1). The functional status composite score, the number of 22 daily and physical tasks that a patient could perform independently, measured at baseline and 1, 3, 6, 9, and 12 months postoperatively were analyzed using linear mixed-effects model. RESULTS: The mean age was 84.2 years; 74 subjects were women (51.8%). Patients with moderate-to-severe frailty and cognitive impairment (n = 27, 19.0%) had the lowest functional status at baseline and throughout 12 months, while patients with mild or no frailty and no cognitive impairment (n = 48, 33.8%) had the best functional status. Patients with cognitive impairment alone (n = 19, 13.4%) had better functional status at baseline than those with moderate-to-severe frailty alone (n = 48, 33.8%), but their functional status scores merged and remained similar during the follow-up. CONCLUSIONS: Preoperative cognitive function plays a vital role in functional recovery after transcatheter aortic valve replacement, regardless of baseline frailty status. Impaired cognition may increase functional decline in the absence of frailty, whereas intact cognition may mitigate the detrimental effects of frailty. Cognitive assessment should be routinely performed prior to transcatheter aortic valve replacement.


Assuntos
Atividades Cotidianas , Estenose da Valva Aórtica/cirurgia , Disfunção Cognitiva/fisiopatologia , Fragilidade/fisiopatologia , Desempenho Físico Funcional , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Disfunção Cognitiva/complicações , Estudos de Coortes , Feminino , Fragilidade/complicações , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS