Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 105: 189-200, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38588951

RESUMO

BACKGROUND: Pediatric extremity vascular injuries constitute a rare yet serious entity that can lead to serious complications especially if left untreated or become late diagnosed. In our scoping review, we sought to evaluate different characteristics and outcomes of pediatric and combined adult trauma centers (ATCs) in the management of pediatric extremity vascular injury. METHODS: We sought to analyze various characteristics and parameters that differentiate a dedicated pediatric and a combined pediatric ATC in terms of effectiveness and quality of care in the acute setting and to describe special features and characteristics of an acute vascular disease that constitute pediatric population unique from the aspect of diagnosis and management. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping reviews guidelines to conduct the study. RESULTS: The search identified 8,815 records in title using MeSH terms from PubMed/MEDLINE database among which 12 studies reporting a total of 2,124 pediatric patients with vascular extremity injuries were included for analysis. Incidence of pediatric extremity vascular injury was 0.5%. Upper extremity injuries were the most frequent presenting in 63% of cases followed by lower extremity injuries in 37% of cases. Blunt injuries were marginally more common than penetrating injuries (58% vs. 42%). In-hospital mortality and morbidity ranged from 13.2% to 0.9% and 13% to 30%, respectively. Limb-salvage rates were high, ranging from 92% to 99%. Furthermore, there are no clearly defined clinical guidelines involving the mode of imaging and diagnosis, the surgical specialties involved and the competency of nursing or medical staff overall. CONCLUSIONS: Dedicated children trauma centers theoretically represent the optimal path for acute pediatric trauma admission, especially in complex trauma necessitating vascular reconstruction. However, in the current setting of rapidly increasing health costs and economic crisis worldwide, regional or resource-related factors make this option rather unavailable. In any case, it is imperative the clinicians have a high index of suspicion when confronting with these types of injuries because early diagnosis is highly related with reduced morbidity and superior outcomes.


Assuntos
Centros de Traumatologia , Lesões do Sistema Vascular , Humanos , Lesões do Sistema Vascular/terapia , Lesões do Sistema Vascular/mortalidade , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/epidemiologia , Centros de Traumatologia/normas , Criança , Adolescente , Fatores Etários , Resultado do Tratamento , Fatores de Risco , Pré-Escolar , Masculino , Feminino , Lactente , Procedimentos Cirúrgicos Vasculares/normas , Mortalidade Hospitalar , Extremidades/irrigação sanguínea , Extremidades/lesões , Fatores de Tempo
2.
J Vasc Surg ; 78(3): 668-678.e14, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37141949

RESUMO

OBJECTIVE/BACKGROUND: To investigate the long-term outcomes after endovascular aneurysm repair (EVAR) in a real-world setting using the Endurant endograft (EG). METHODS: 184 EVAR candidates treated with the Endurant family EGs in a single vascular center were prospectively enrolled from January 2009 to December 2016. Kaplan-Meir estimates of long-term standardized primary and secondary outcome measures were performed. Per protocol, subgroup comparison analysis was performed in three groups: patients treated within instructions for use (in-IFU) vs patients treated outside IFU (outside-IFU), EVAR in patients receiving the Endurant proximal diameter 32 or 36 mm EG vs those receiving the <32 mm diameter EG and EVAR with various Endurant EG versions. RESULTS: The mean follow-up was 75.09 ± 37.9 months (range: 4.1-172 months). The median age of the patients was 72.96 ± 7.03 years (range: 55-88 years). A total of 177 patients were male (96.2%). Compliance with IFU was followed in 107 patients (58.2%). Overall survival was 69.5% and 48% at 5 and 8 years, respectively. Of the 102 all-cause deaths, 7 (6.9%) were aneurysm related. Six of these postimplant deaths occurred in patients presented with aneurysm rupture from type Ia or/and type Ib endoleak. At 5, 8, and 10 years of observation, freedom from aneurysm rupture, open surgical conversion, type I/III endoleak, any type of endoleak, aneurysm-related secondary intervention probabilities, and neck-related events were as follows: 98.1%, 95%, and 89.4%; 95.1%, 91.2%, and 85.7%; 93.6%, 87.3%, and 83.9%; 83.4%, 74%, and 70.9%; 89.8%, 76.7%, and 72%; and 96.3%, 90%, and 87.6%, respectively. Corresponding clinical success was 90%, 77.4%, and 68.4%, respectively. Patients treated outside-IFU had significantly higher risk of aneurysm rupture, open surgical conversion probability, occurrence of type I/III endoleak, and chance of reinterventions and lower clinical success probabilities compared with the in-IFU counterparts at 5 and 8 years. This statistical difference remained when type Ia endoleak or endoleak of any type was considered independently. In addition, it was stronger in patients having extreme anatomic boundaries (>1 hostile anatomic condition), when aneurysm-related death, aneurysm rupture, and clinical success at 5 years were considered. Overall proximal migration and limb occlusion were recorded in 1.1% and 4.9% of the patients, respectively. Overall reintervention rate was 17.4%. An increase in aneurysm sac diameter was observed in 12.5% of patients and was not related to IFU status. The Endurant version or the proximal EG diameter had no significant association with the chance of any complication or adverse event. CONCLUSIONS: The data confirmed the durability of the Endurant EG, achieving promising long-term outcomes in a real-world setting. However, its positive performance must be interpreted with caution in patients treated off-label especially those with extreme anatomic boundaries. In this cohort, some of EVAR advantages might be lost in the late future. Further similar studies are warranted.


Assuntos
Aneurisma Roto , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Fatores de Risco , Resultado do Tratamento , Aneurisma Roto/cirurgia , Estudos Retrospectivos
3.
J Endovasc Ther ; 29(4): 646-658, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34836463

RESUMO

PURPOSE: Thoracic endovascular aortic aneurysm repair (TEVAR) has emerged as an attractive alternative option in the treatment of thoracoabdominal aortic aneurysm (TAAA) diseases, reporting lower morbidity and mortality rates compared with open or hybrid repair. A challenging situation arises when the aneurysm involves the celiac artery (CA), precluding a safe distal landing zone. We investigated the safety and efficacy of CA coverage in the treatment of complex TAAA diseases during endovascular management. MATERIALS AND METHODS: A review of the literature was conducted in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines. The electronic bibliographic sources searched were MEDLINE and SCOPUS databases. Primary outcomes of interest were perioperative and 30-day mortality. Any type of endoleak, mesenteric ischemia, perioperative spinal cord ischemia, and reintervention rates were secondary end points. A random-effects meta-analysis was performed. Summary statistics of event risks were expressed as proportions and 95% confidence interval (CI). RESULTS: Ten observational cohort studies published between 2009 and 2020, reporting a total of 175 patients, were eligible for quantitative synthesis. Indications for TEVAR were primary TAAAs in 82% of patients, aortic dissection in 14% of patients, type Ib endoleak after previous endograft deployment in 3% of patients, and penetrating aortic ulcer in 1 patient. Reintervention rate was 9% (95% CI, 4%-20%) and spinal cord ischemia was 7% (95% CI, 4%--12%). Type II endoleak was the predominant type of endoleak in 10% of patients (95% CI, 4%-22%), followed by type I endoleak in 5% of patients (95% CI, 2%-12%) and type III endoleak in 1% (95% CI, 0%-16%) of patients. Mesenteric ischemia occurred in 6% of patients (95% CI, 3%-10%). Thirty-day mortality was 5% (95% CI, 2%-13%) and the pooled estimate for overall mortality was 21% (95% CI, 14%-31%). CONCLUSIONS: Celiac artery coverage during TEVAR is a challenging but feasible option for the treatment of TAAA diseases, providing acceptable morbidity and mortality rates. Demonstration of adequate visceral collateral pathways before definitive CA coverage is the sine quo non for the success of the technique.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia Mesentérica , Isquemia do Cordão Espinal , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Artéria Celíaca/diagnóstico por imagem , Artéria Celíaca/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Isquemia Mesentérica/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
4.
Ann Vasc Surg ; 83: 313-327, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34954375

RESUMO

BACKGROUND: The creation of an arteriovenous fistula in obese patients with end-stage-renal-disease, might not lead to a successful hemodialysis session, partly due to excess adipose tissue overlapping the enlarged vein. This review summarizes the available evidence on superficialization methods in studies dealing with obese patients. METHODS: An English-language literature search was undertaken in the MEDLINE/SCOPUS databases looking for publications that described procedures of salvaging autologous arteriovenous access in upper extremities of obese patients. Perioperative outcomes including technical and clinical success, mean vein depth reduction, wound complications and patency rates were compared within all identified techniques. RESULTS: We identified 12 prospective and 8 retrospective studies. A total of 1149 patients with a mean age 57.2 (range: 49-68) years and a mean BMI 35.8 (range: 28.2-40.8) kg/m2 underwent mainly radial-cephalic and brachial-cephalic arteriovenous fistula superficialization procedures [transposition, 54%; elevation, 11.1%; lipectomy, 26.1%; liposuction, 2.4%; implantation of a venous window needle guide device, 6.4%]. Technical success was similar between all methods (≥96%). However, successful cannulation was lower after liposuction and elevation (81.5% and 78.1% respectively). Transposition achieved lower mean vein depth reduction and clinical success when compared with lipectomy (4.9 mm vs. 8.8 mm and 90% vs. 92.7% respectively). Transposition and liposuction had the lowest and highest complication rate respectively (1.6% vs. 40.8%). Primary and secondary patency rates were lower with liposuction (51.8% and 76.6% respectively), while lipectomy and elevation achieved the highest primary patency rates (68.3% and 71.6% respectively) at 12 months. CONCLUSIONS: In obese patients, all superficialisation techniques report high technical success rates. Although limited by the design of individual published studies and lack of a standard for reporting outcomes, these results lead to satisfactory postoperative and early outcomes. In aggregate, lipectomy and transposition are more clinically effective and more durable procedures.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Fístula Arteriovenosa/complicações , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/métodos , Humanos , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico , Estudos Prospectivos , Diálise Renal , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular
5.
J Vasc Surg ; 73(6): 2198-2203.e3, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33385504

RESUMO

OBJECTIVE: We investigated the comparative effectiveness of different endovascular treatments for patients with failing autogenous arteriovenous fistulas (AVFs) with outflow vein stenosis. METHODS: The Medline (via PubMed) and SCOPUS databases were searched. We performed a systematic review and network meta-analysis of randomized controlled trials that had investigated the effectiveness of plain balloon angioplasty (PBA), cutting balloon angioplasty, and drug-coated balloon angioplasty (DCBA) to treat vein stenoses in autogenous AVFs. Studies of central vein stenosis were excluded. The main outcome measures were the failure rates at 6 months and 1 year after treatment. RESULTS: Eleven randomized controlled trials were included, with 814 patients, 395 of whom had undergone PBA. The network meta-analysis showed that DCBA at 6 months was significantly more effective than PBA (odds ratio, 0.39; 95% confidence interval, 0.18-0.81) and ranked as the best treatment option, although the difference was not statistically significant compared with cutting balloon angioplasty (odds ratio, 0.65; 95% confidence interval, 0.20-2.12). The differences among the three treatments at 1 year were not statistically significant. Additional conventional pairwise meta-analyses did not find significant differences at 1 year. CONCLUSIONS: In failing AVFs with outflow stenosis, DCBA was significantly superior to PBA, with improved 6-month failure rates. However the effectiveness of DCBA in the long term deserves further investigation.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Desenho de Equipamento , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular
6.
Eur J Vasc Endovasc Surg ; 61(2): 181-190, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33257115

RESUMO

OBJECTIVE: There is discordance between reviews comparing eversion endarterectomy (EvE) with conventional carotid endarterectomy (CEA) mostly because under this term various "closure" techniques are included, from direct closure to a wide spectrum of patches with different materials. DATA SOURCES: MEDLINE (via PubMed) and SCOPUS. REVIEW METHODS: This was a systematic review of the Medline (via PubMed) and SCOPUS databases for randomised controlled trials (RCTs) comparing different CEA closure techniques. Network meta-analysis (NMA) was performed with a frequentist approach. The primary and the secondary outcome measures were the 30 day combined stroke and death rate and the late restenosis rate, respectively. RESULTS: Twenty-three RCTs were finally included in the NMA with a total of 4440 patients randomised, representing seven different techniques (primary carotid closure, n = 753; EvE, n = 431; vein patch closure, n = 973; polytetrafluoroethylene [PTFE] patch, n = 948; Dacron patch, n = 828; bovine pericardium patch, n = 249; and polyurethane patch, n = 258). NMA showed that EvE had a decreased 30 day combined stroke and death rate vs. all other methods of arterial closure, with the exception of PTFE and bovine pericardium patching. Additionally, EvE was associated with the lowest restenosis rate vs. all other methods of arterial closure after CEA. EvE was significantly superior to Dacron patches with regard to late restenosis, with the prediction intervals (PIs) lying completely on the beneficial side (risk ratio 0.06; PI 0.01-0.58) and increasing confidence of this comparison. Rare catastrophic complications of vein patch blow out or synthetic patch infection were reported in 0.2% of the total (n = 9/4 400) and no comparisons were made. CONCLUSION: EvE and patching with bovine pericardium or PTFE is associated with a lower incidence in both short term and late undesired outcomes following CEA and seems to represent the best choice compared with other carotid closure techniques. These results may support the vascular surgeon's choice of technique/patch material.


Assuntos
Materiais Biocompatíveis , Implante de Prótese Vascular/métodos , Prótese Vascular , Artérias Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Técnicas de Fechamento de Ferimentos , Implante de Prótese Vascular/instrumentação , Humanos , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/prevenção & controle
7.
Ann Vasc Surg ; 74: 502-510, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33831516

RESUMO

BACKGROUND: Vascular access (VA)-related high flows (HF) are common with brachial artery based fistulas. Flow-reduction procedures are indicated in symptomatic patients or asymptomatic ones with flows >2 L/min. However concomitant issues increase their complexity. We describe a case of a patient suffering congestive heart failure as a result of HF brachial-basilic fistula >3 L/min. A simultaneous late basilic vein transposition and revision using distal inflow (RUDI) was performed. METHODS: A large diameter untransposed arterialized basilic vein was carefully and completely mobilized up to the proximal upper arm. After harvesting an autologous great saphenous vein (GSV) segment, a new inflow anastomosis was performed in the proximal ulnar artery. At the final stage, and after tunneling the mobilizing basilic vein in a subcutaneous semicircular configuration, an end-to-end anastomosis joining the two stumps (basilic vein outflow portion and GSV inflow arterial portion) was performed. A decision-making process in order to reach this complex option is discussed. Results Access flow and cardiac output were greatly attenuated following our approach. After a mean follow-up of 9 months no VA complications were observed, with flow still detected below 2 L/min. All cardiac symptoms and ultrasound investigations improved. CONCLUSION: Multiple VA issues including HF pose a risk for abandonment and a challenge for the vascular surgeon. An effort toward increasing the "upper extremity life span" is advised.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Veia Axilar/cirurgia , Veia Safena/transplante , Artéria Ulnar/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Veia Axilar/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Diálise Renal , Reoperação , Veia Safena/diagnóstico por imagem , Ultrassonografia , Extremidade Superior/irrigação sanguínea
8.
Ann Vasc Surg ; 71: 356-369, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32890649

RESUMO

BACKGROUND: Delayed open conversion (OpC) after endovascular aortic aneurysm repair (EVAR) is becoming increasingly common worldwide. We reviewed our experience to characterize the perioperative spectrum of OpC repairs. MATERIALS AND METHODS: A retrospective analysis of a prospectively maintained institutional database to identify patients who underwent late OpC after failed EVAR was performed. Patient and aneurysm baseline characteristics, mechanism of failure, perioperative details, including type of repair/complications/survival, and late outcomes were examined. RESULTS: From January 2003 to January 2020, 38 male patients (mean age, 75 ± 7 years; range, 60-90) required late OpC. Interval time from initial EVAR to OpC was 63.6 ± 33.8 months (range, 17-120). Mean diameter of the aneurysms was 82.2 ± 22.1 mm before OpC compared with 62.9 ± 13 mm before endograft implantation. Mechanisms of failure were type Ia, Ib, II, and III endoleaks in 14 (36.8%), 9 (23.7%), 4 (10.5%), and 1 (2.6%) patient(s), respectively; infection in 3 (7.9%), leg ischemia in 2 (5.3%), and multiple causes in 5 (13.2%) patients. We observed 4 (10.5%) asymptomatic, 16 (42.1%) symptomatic, and 18 (47.3%) ruptured aneurysms. Four patients (10.5%) had stable contained ruptures, whereas the remaining 13 (34.2%) and 1 additional patient (2.6%) with aortoenteric fistula presented with hemorrhagic shock (class ≥II). Total endograft explantation, endograft preservation, or proximal/distal partial graft removal was performed in 16 (42.1%), 10 (26.3%), and 2 (5.2%)/9 (23.7%) of patients, respectively. Technical success was 100%, excluding an early postaortic clamping death. Overall, 30-day mortality was 21.1% (8 of 38) and significantly higher in patients with hemorrhagic shock or hemodynamic instability at presentation (P = 0.04 and P = 0.009, respectively) and in patients who had endografts with hooks/barbs or experiencing higher postoperative complication rate (P = 0.02 and P = 0.006, respectively). By definition, procedure success was 81.1%. Mean follow-up was 37.6 ± 39.8 months. By the end of the study, we recorded 11 deaths (2 were aneurysm related). CONCLUSIONS: Despite high technical success, OpC has a significant mortality in patients presenting with hemorrhagic shock and had active fixation endografts or experiencing high complication rate. Many other confounding factors may play a role.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Remoção de Dispositivo , Procedimentos Endovasculares , Complicações Pós-Operatórias/cirurgia , Reoperação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Reoperação/efeitos adversos , Reoperação/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Falha de Tratamento
9.
Ann Vasc Surg ; 68: 542-544, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32562831

RESUMO

The use of social media for academic or research purposes is still in infancy. However, the potential of dissemination of medical knowledge through these electronic platforms is dynamically increasing. We performed a search on Twitter® collecting tweets containing the keywords "peripheral arterial disease" and "abdominal aortic aneurysm" separately and including 3 types of emitters. Our aim was to assess the dissemination of these 2 major vascular entities across the social networking and their effect on the medical and general population. The results show that people talk about their experiences of hospitals and care quality on Twitter® more than health care providers or commercial industries in critical diseases that arise more concern. Twitter® could become a successful channel through which physicians, patients, and health care providers interact, engage, and disseminate medical knowledge.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Medicina Baseada em Evidências , Disseminação de Informação , Doença Arterial Periférica/cirurgia , Mídias Sociais , Procedimentos Cirúrgicos Vasculares , Humanos , Satisfação do Paciente , Indicadores de Qualidade em Assistência à Saúde , Comunicação Acadêmica
10.
Ann Vasc Surg ; 68: 568.e1-568.e5, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32278872

RESUMO

We report an innovative technique in an 82-year-old patient with a patent but infected right axillobifemoral (AxBF) bypass performed 7 years ago owingto critical limb ischemia who underwent a semielective de novo left-sided composite AxBF bypass consisting of a central prosthetic polytetrafluoroethylene segment and distal autologous limbs to the femoral regions (femoral crossover bypass vein to the right limb using the femoral vein and jump graft to the left femoral limb using the great saphenous vein.) Although AxBF bypass is not considered the "gold standard" surgical composite revascularization procedure in the suprainguinal region, it can constitute an acceptable intervention in selected cases.


Assuntos
Artéria Axilar/cirurgia , Implante de Prótese Vascular , Remoção de Dispositivo , Veia Femoral/transplante , Doença Arterial Periférica/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Veia Safena/transplante , Idoso de 80 Anos ou mais , Artéria Axilar/diagnóstico por imagem , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Humanos , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Resultado do Tratamento
11.
J Endovasc Ther ; 26(6): 826-835, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31464166

RESUMO

Purpose: To investigate whether plasma and connective tissue matrix metalloproteinases (MMP) and their inhibitors (TIMP) may predict late high-pressure endoleak after endovascular aneurysm repair (EVAR). Materials and Methods: Samples of inguinal fascia and blood were collected in 72 consecutive patients (mean age 73.1 years; 68 men) undergoing primary EVAR with the Endurant stent-graft. Baseline plasma levels of MMP-2, MMP-9, TIMP-1, and TIMP-2 and baseline MMP-2 and MMP-9 activity estimated using gelatin zymography (GZ) were compared between patients who developed late endoleak in follow-up and those who did not. Subgroup analyses were performed between patients with (n=18) and without inguinal hernias and between patients with moderate-diameter (50-59 mm; n=45) or large-diameter (≥60 mm; n=27) abdominal aortic aneurysms (AAA) at primary EVAR. Results: The mean follow-up period was 63.1 months (range 7.5-91.5), during which time 13 (18.1%) patients developed type I (6 Ia and 5 Ib) or 2 type III endoleaks. Only GZ-analyzed proMMP-9 concentrations were higher in the endoleak group than in patients without endoleak (mean difference 8.44, 95% CI -19.653 to -1.087, p=0.03). The patients with primary inguinal hernia at presentation had significantly higher tissue TIMP-2 values (0.8±0.7 vs 0.5±0.4, p=0.018) but lower plasma total (pro- + active) MMP-9 values (11.9±7.8 vs 16.2±7.4, p=0.042) than patients without hernias at the time of EVAR. Patients with AAAs ≥60 mm had significantly higher mean tissue homogenate levels of total (pro- + active) MMP-9 (p=0.025) and total (pro- + active) MMP-2 (p=0.049) as well as higher proMMP-9 (p=0.018) and total (pro- + active) MMP-9 (p=0.021) levels based on GZ compared to patients with moderate-diameter AAAs. Regression analysis revealed a significant association between total (pro- + active) MMP-9 plasma samples and the presence of hernia (OR 0.899, 95% CI 0.817 to 0.989, p=0.029) and between GZ-analyzed proMMP-9 and late endoleak (OR 1.055, 95% CI 1.007 to 1.106, p=0.025). GZ-analyzed proMMP-9 and active MMP-9 were strong predictors of late endoleak in patients with hernia (p=0.012 and p=0.044, respectively) and in patients with AAAs ≥60 mm (p=0.018 and p=0.041 respectively). Conclusion: Inguinal fascial tissue proMMP-9 significantly predicted late endoleak. ProMMP-9 and active MMP-9 biomarkers are significantly associated with late endoleak in hernia patients and in patients with AAAs ≥60 mm. Considering the clinical association between hernia and AAA and the fact that the AAA wall connective tissue environment remains exposed to systemic circulation after EVAR, inguinal fascia extracellular matrix dysregulation and altered MMP activity may reflect similar changes in AAA biology, leading to complications such as endoleak.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Metaloproteinase 9 da Matriz/sangue , Inibidores Teciduais de Metaloproteinases/sangue , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Biomarcadores/sangue , Endoleak/sangue , Endoleak/diagnóstico , Endoleak/fisiopatologia , Feminino , Humanos , Masculino , Metaloproteinase 2 da Matriz/sangue , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Inibidor Tecidual de Metaloproteinase-1/sangue , Inibidor Tecidual de Metaloproteinase-2/sangue , Resultado do Tratamento
12.
Eur J Vasc Endovasc Surg ; 58(6): 921-928, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31706740

RESUMO

OBJECTIVE: There is currently uncertainty regarding the ideal treatment to salvage thrombosed or failing synthetic arteriovenous grafts (AVGs) in patients with end stage renal disease. Therefore, a systematic review up to December 2018 and network meta-analysis of randomised control trials (RCTs) that compared three month failure risk of available treatments was carried out. METHODS: Medline, Scopus, Embase, and the Cochrane Library were the data sources. Pairwise meta-analyses were based on random effects models. Network meta-analysis was conducted within a frequentist framework with a multivariable random effects approach to model treatment effects across studies. The metric of choice was the odds ratio (OR) along with the associated 95% confidence interval (CI). RESULTS: Sixteen two arm RCTs were included involving 2011 patients who were randomised to six different treatments (plain balloon angioplasty, open surgical repair, stents, stent grafts, drug eluting balloons (DEBs), and cutting balloons). The network of RCTs had a star like geometry with plain balloon angioplasty being the common comparator. There were no significant differences between treatments with regards to risk of failure at three months with the exception of stent graft use that significantly reduced the risk of failure compared with plain balloon angioplasty (OR 0.53, 95% CI 0.34-0.84). Based on surface under the cumulative ranking curve (SUCRA) values, the best interventions to salvage thrombosed or failing AVGs were DEB and stent grafts. CONCLUSIONS: Stent graft seems to perform better than plain balloon angioplasty in terms of saving thrombosed or failing AVGs. However, this network meta-analysis was limited by the lack of closed loops and thus unable to assess consistency between direct and indirect evidence. The efficacy of DEBs as a promising treatment deserves further investigation and new RCTs are required.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Falência Renal Crônica/complicações , Terapia de Salvação/métodos , Trombose/terapia , Angioplastia com Balão/instrumentação , Angioplastia com Balão/métodos , Artérias/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Catéteres , Oclusão de Enxerto Vascular/etiologia , Humanos , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Terapia de Salvação/instrumentação , Stents , Trombose/etiologia , Fatores de Tempo , Falha de Tratamento , Grau de Desobstrução Vascular , Veias/cirurgia
13.
Ann Vasc Surg ; 49: 311.e1-311.e9, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29421425

RESUMO

BACKGROUND: Unfavorable anatomy is one of the major limitations of endovascular aortic aneurysm repair (EVAR) with specifically adverse proximal neck morphology excluding many patients from receiving the standard endograft devices. Thoracic tube endografts have been used to overcome the issue of wide infrarenal necks, either as a sole device (single tubes or double tubes using the trombone technique) or as the proximal part of a bifurcated device fixed to the aortic bifurcation or infrarenally oriented. However, custom-made large proximal diameter bifurcated endograft designs have never been used. METHODS: We present the case of a 56-year-old man with Marfan syndrome, suffering abdominal aortic aneurysm (AAA) enlargement from a type Ib endoleak after previous EVAR with 2 Endofit tube endografts (trombone technique). He was considered unfit for open surgery while possible alternatives such as fenestrated endovascular AAA repair and chimney technique were excluded. RESULTS: The patient was treated with a custom-made 44-mm proximal diameter, bifurcated Bolton Medical Treovance device with technical and clinical success. No immediate or perioperative complications were noted. Follow-up after 6 months showed graft patency and no endoleak of any type. CONCLUSIONS: This alternative technique for hostile proximal neck management is promising and needs long-term follow-up; an issue which is discussed within the broader context of custom-made device regulations.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Síndrome de Marfan/complicações , Falha de Prótese , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Síndrome de Marfan/diagnóstico , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento
14.
Ann Vasc Surg ; 48: 252.e9-252.e14, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29421417

RESUMO

We report the case of a 79-year-old man who was admitted to our department with acute limb ischemia due to the occlusion of the left iliac limb of an Endurant endograft. The admission computed tomography angiography revealed also a type IIIa endoleak due to modular disconnection of the iliac extensions from the right iliac limb of the endograft main body. Interestingly, during the 4-year post-endovascular aneurysm repair period, an increased kinking of the right limb has been observed leading to an almost cross-limb configuration of the limbs at the time of complications. To our knowledge, this is the first case in the literature of the simultaneous presence of limb thrombosis and late type IIIa endoleak with this particular device. The ischemia was treated with a femoro-femoral cross-over bypass, and the endoleak was corrected with the position of 2 Endurant iliac limb extensions bridging the dislocated endograft pieces.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/etiologia , Oclusão de Enxerto Vascular/etiologia , Artéria Ilíaca/cirurgia , Isquemia/etiologia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/cirurgia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Masculino , Desenho de Prótese , Resultado do Tratamento
15.
J Endovasc Ther ; 24(5): 688-697, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28756719

RESUMO

PURPOSE: To report a meta-analysis of the published evidence on the outcomes of aortic endograft infection after endovascular aneurysm repair (EVAR). METHODS: A search of electronic information sources (PubMed/MEDLINE, SCOPUS, CENTRAL) and bibliographic reference lists identified 12 studies reporting on 362 patients (mean age 72 years; 279 men). The methodological quality of the selected studies was assessed using the Newcastle-Ottawa scale. Endpoints were 30-day/in-hospital mortality and follow-up mortality. Pooled estimates are reported with the 95% confidence interval (CI). The review was registered at the International Prospective Register of Systematic Reviews in Health and Social Care (CRD42016034166). RESULTS: The incidence of graft infection after EVAR was 0.6% (95% CI 0.4% to 0.8%). The time from implantation to diagnosis ranged from 1 to 128 months (mean 25). The majority of patients (293, 81%) underwent surgical treatment (95% CI 77% to 83%); 9 (2.5%) patients (95% CI 21% to 43%) received conservative treatment. Aortic replacement with a prosthetic graft was performed in 58% (95% CI 52% to 62%), whereas cryopreserved allografts and autologous grafts were used in 31% (95% CI 28% to 33%) and 11% (95% CI% 8 to 14%), respectively. Less than half of the patients (40%) had emergency surgery. The pooled estimate of 30-day/in-hospital mortality was 26.6% (95% CI 16.9% to 39.2%). The pooled 30-day/in-hospital mortality for 9 patients treated conservatively was 63.3% (95% CI 30.7% to 87.0%). The pooled overall follow-up mortality was 45.7% (95% CI 36.4% to 55.4%) vs 58.6% (95% CI 28.8% to 83.3%) for the 9 patients receiving conservative treatment. CONCLUSION: Aortic endograft infection is a rare complication after EVAR. Surgical treatment with complete explantation of the infected endograft seems to be the optimal management in selected patients. Supportive medical treatment without surgical intervention has a significant associated mortality.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Infecções Relacionadas à Prótese/microbiologia , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/mortalidade , Tratamento Conservador , Remoção de Dispositivo , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Endovasc Ther ; 24(4): 559-565, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28597730

RESUMO

PURPOSE: To present early results with the Treovance aortic stent-graft in the treatment of abdominal aortic aneurysms (AAAs). METHODS: Between October 2013 and January 2016, 35 consecutive AAA patients (mean age 74±7.7 years; 32 men) were treated with Treovance. The maximum diameter of the treated AAA was 60±9 cm. Nine (25%) patients presented with concomitant iliac aneurysms. Seven (20%) AAAs had infrarenal neck angulation >60°. The infrarenal neck length and diameter were 21.6±12.6 mm and 25.7±4.6 mm, respectively. Sixteen (45%) AAAs had a reversed tapered neck contour. Six (17%) and 9 (25%) patients showed severe or moderate iliac tortuosity, respectively. Primary endpoints were endoleak, reintervention, and aneurysm-related death. RESULTS: Primary technical success was 94% due to 2 intraoperative type Ia endoleaks, which were successfully treated with a proximal aortic extension (100% assisted primary technical success). Local dissection was encountered in 5 (7%) of 70 femoral artery access sites in 4 patients. During a mean 12-month follow-up (range 6-24), clinical success was 97%. No type I or III endoleak, death, AAA rupture, open conversion, or device-related serious adverse events were documented. Four type II endoleaks were detected; one resolved spontaneously at 12 months and 2 remained stable, while one associated with AAA sac enlargement was treated successfully with embolization of the lumbar arteries (3% reintervention rate). CONCLUSION: Treovance shows accurate deployment even through angulated and tortuous iliac vessels and presents satisfactory conformability in highly angulated necks with acceptable clinical results. Future development to lower the profile and increase the flexibility of its delivery system will enhance its applicability in cases of narrow access vessels.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Ann Vasc Surg ; 40: 300.e17-300.e21, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28163182

RESUMO

Although small (<5 cm) abdominal aortic aneurysms (AAA) have been associated with symptoms and indication for intervention scarcely, the clinicians should never exclude such potential association especially in the absence of other overt pathological findings. In such cases, a surgical exploration with consequent intervention, if feasible, should be justified to prevent a detrimental evolution in a dubious scenario. In this article, we present 2 cases of patients with small AAA presenting with severe abdominal pain. In the absence of other solid clinical and radiological pathological findings, both patients underwent laparotomy where an inflammatory small AAA was identified and subjected either to resection and restoration with a tube graft or secondary endovascular repair because the periaortic fibrosis precluded the open repair. The characteristics and rationale of treatment modalities are exemplified and discussed.


Assuntos
Dor Abdominal/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Dor Abdominal/diagnóstico , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Valor Preditivo dos Testes , Fibrose Retroperitoneal/etiologia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Ann Vasc Surg ; 40: 146-153, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27890833

RESUMO

BACKGROUND: Ovation aortic stent-graft system is a new device for the endovascular treatment of Abdominal Aortic Aneurysms achieving fixation via a 35-mm long, rigid anchored suprarenal stent and sealing stent at the infrarenal level by a means of a polymer-filling pair of inflatable O-rings, which cause narrowing of flow lumen and regional stenosis. Thus, concerns have been raised regarding hemodynamic consequences associated with this new design. Our preliminary report showed no significant increase of aortic pulse wave velocity (aPWV) immediately after implantation of the ovation in 3 patients. We studied further the hemodynamic implications of the Ovation implantation in 6 patients for a follow-up of 6 months. METHODS: A brachial cuff-based automatic oscillometric device (Mobil-O-Graph; IEM, Stolberg, Germany) was used to perform noninvasively pulse wave analysis and stiffness estimation. Measurements were held preoperatively in 6 patients treated for abdominal aortic aneurysm, at the end of the first postoperative week, first and sixth postoperative month. Changes in systolic and diastolic blood pressure (cSyst, cDiast), heart rate, aPWV, augmentation index (AI@75), augmentation pressure (AP), and in the amplitude ratio of the reflected-to-forward pressure waves (reflection magnitude, RM) were recorded and compared. Significant change in any parameter was examined via analysis of variance repeated measures. RESULTS: The cSyst was 132 ± 19.6, 127 ± 17.63, 131.3 ± 19.96, and 129.83 ± 31.72 mm Hg (P = 0.81) and cDiast was 88 ± 10.58, 86.83 ± 11.72, 89.83 ± 16.01, and 98.5 ± 24.56 mm Hg (P = 0.40). The heart rate showed an increasing yet nonsignificant tendency (67 ± 10.60, 75.1 ± 8.63, 74.33 ± 8.89, and 70.66 ± 6.65 beats/min, 0.27). The aPWV remained constant (11.61 ± 1.88, 11.6 ± 1.74, 11.8 ± 2.08, and 11.85 ± 2.30 m/sec, P = 0.79). Similarly, RM (71.16 ± 9.94, 60.66 ± 11.79, 61.5 ± 14.47, and 64.5 ± 3.78), AI@75 (33.83 ± 12.25, 22.16 ± 7.93, 27.83 ± 11.23, and 19.5 ± 14.72), and AP (18.33 ± 10.36, 9.83 ± 4.91, 11.5 ± 9.22, and 12 ± 15.08 mm Hg) remained practically unaltered during the follow-up period (P value: 0.79, 0.25, 0.10, and 0.27), respectively. CONCLUSIONS: The implantation of the Ovation stent graft does not cause increase in aortic stiffness or in pulse wave reflection in the mid-period. The rationale of investigating noninvasively the impact of aortic stent grafts on the mechanical properties and the hemodynamic parameters should be encouraged because such findings may contribute to further development of newer endograft designs.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Análise de Onda de Pulso , Stents , Rigidez Vascular , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Pressão Sanguínea , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Ann Vasc Surg ; 43: 210-217, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28389287

RESUMO

BACKGROUND: Patients undergoing revascularization for infrarenal aortic occlusion (IAO) have been reported to present improved survival rates compared to those treated conservatively. Aim of this study was to investigate the hemodynamic changes induced after revascularization for IAO, as expressed with pulse wave velocity (PWV), augmentation index (Aix), augmentation pressure (AP), and pulse wave reflection coefficient (RC). MATERIALS AND METHODS: Twelve patients underwent revascularization (9 aortobifemoral/aortobiiliac bypasses, 2 primary iliac stenting, and 1 hybrid procedure of unilateral aortoiliac stenting and crossover bypass). Calculation of hemodynamic parameters was performed in all patients preoperatively, at 1 month, and 1 year postoperatively. Pulse wave analysis was performed noninvasively with a novel validated brachial cuff-based automatic oscillometric device (Mobil-O-Graph; IEM, Stolberg, Germany). The estimated hemodynamic parameters were AIx, AP, RC, and PWV. Data were analyzed with the Friedman analysis of variance test. RESULTS: Aix decreased significantly at 1 month and further at 1 year postoperatively compared to preoperative values (24 ± 11 and 17 ± 13 vs. 34 ± 13.5, respectively, P = 0.0006). AP decreased at 1 month and 1 year postoperatively compared to preoperative values (6.5 ± 4 mm Hg and 8 ± 6.5 mm Hg vs. 13 ± 12 mm Hg, respectively, P = 0.045). RC decreased also at 1-month and 1-year postoperatively compared to preoperative values (62 ± 5.5, 64 ± 4.3 vs. 73 ± 5.1, respectively, P = 0.002). However, changes in PWV were less prominent in this short-term postoperative period. CONCLUSIONS: Improved hemodynamic profile may theoretically contribute to the enhanced survival rates of these patients.


Assuntos
Doenças da Aorta/cirurgia , Arteriopatias Oclusivas/cirurgia , Procedimentos Endovasculares , Hemodinâmica , Enxerto Vascular , Idoso , Angiografia Digital , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Aortografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Pressão Arterial , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso/instrumentação , Stents , Fatores de Tempo , Resultado do Tratamento , Enxerto Vascular/efeitos adversos , Rigidez Vascular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa