Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Cardiol Sin ; 40(3): 331-339, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38779166

RESUMO

Background: The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR). Methods and Results: Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINELTM cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases. Conclusions: Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.

2.
Acta Cardiol Sin ; 35(4): 380-386, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31371898

RESUMO

BACKGROUND: Transcatheter aortic valve-in-valve implantation (aVIV) has been used to treat bioprosthetic failure due to "stent creep", defined as inward flexion or bending of stent posts. The aim of this study was to develop quantitative three-dimensional transesophageal echocardiography (3D-TEE) geometric analysis of failed bioprostheses to determine the incidence of stent creep in patients undergoing aVIV and its contribution to the hemodynamics of those valves. METHODS: We retrospectively examined the 3D-TEE of 22 consecutive patients (age 74.4 ± 11.3 years; M/F = 12/10) who underwent aVIV for failed bioprostheses. The modes of bioprosthesis failure included stenosis (n = 8), regurgitation (n = 9), and combined (n = 5). The degree of stent creep was assessed by calculating the triangular area obtained by projecting the apex of stent posts on a reconstructed plane. This measured area was divided by that of the regular triangle defined by the base of stent posts to calculate a ratio, which we termed the "stent creep ratio" (SCR). RESULTS: The mean SCR was lower in the patients with failed prostheses than that in the controls (0.82 ± 0.16 vs. 0.96 ± 0.05, p = 0.02). The SCR was negatively correlated with the peak trans-aortic pressure gradient (r = -0.62, p < 0.01). An SCR cut-off point of 0.79 was associated with aortic peak velocity > 4 m/s (AUC = 0.81, sensitivity = 0.79, specificity = 0.83). Fourteen of the 22 patients had pre- and post-aVIV 3D-TEE, and the SCR was corrected satisfactorily from 0.81 ± 0.13 to 1.04 ± 0.19 (p < 0.01). CONCLUSIONS: SCR measured by 3D-TEE is feasible to quantitatively evaluate stent creep. Stent creep is an important mode of structural deterioration in surgical bioprostheses, which can be treated by aVIV.

4.
Echocardiography ; 29(9): E233-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22672577

RESUMO

We report a 66-year-old man who underwent partial reconstruction of the aortic root and presented with heart failure 2 months after the procedure. We used live/real time three-dimensional transesophageal echocardiography (3DTEE) to detect the exact site of the dehiscence flap and extent of the leakage. This information could be valuable to surgeons.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Doenças das Valvas Cardíacas/cirurgia , Deiscência da Ferida Operatória/diagnóstico por imagem , Idoso , Sistemas Computacionais , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Masculino , Deiscência da Ferida Operatória/etiologia
5.
Front Cardiovasc Med ; 9: 767906, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35497985

RESUMO

Objective: Current guidelines recommend that transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve (BAV) with aortic stenosis (AS) should only be performed in selected patients. However, we consider it even more crucial to identify what the really important factors are while determining long-term outcomes in patients with BAV undergoing TAVR, which is precisely the aim of this study. Methods: We retrospectively evaluated consecutive patients who underwent TAVR with balloon-expandable Sapien XT or Sapien 3 valves (Edwards Lifesciences, Irvine, CA) for the treatment of severe bicuspid AS. The primary end points were major adverse cardiac and cerebral events (MACCE), that is, mortality, non-fatal myocardial infarction (MI), disabling stroke, valve failure needing reintervention, or clinically relevant valve thrombosis during follow-up. Results: A total of 56 patients who underwent TAVR with Sapien XT (n = 20) or Sapien 3 (n = 36) were included. The device and procedural success rates were similar between the two TAVR valves; however, the newer-generation Sapien 3 yielded a trend toward better long-term clinical outcomes than the early-generation Sapien XT did (MACCE rates 35 vs. 11%, p = 0.071). In the multivariate Cox proportional hazards analyses, the presence of calcified raphe > 4 mm was the only independent predictor of long-term MACCE (hazard ratio: 6.76; 95% confidence interval: 1.21-37.67, p = 0.029). Conclusion: TAVR performed by a skilled heart team, while using newer-generation balloon-expandable Sapien 3 valve, may yield better long-term clinical outcomes compared to TAVR using early-generation Sapien XT valve. Moreover, the presence of calcified raphe >4 mm is an independent determinant of adverse clinical outcomes.

6.
Ann Transl Med ; 10(1): 24, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35242869

RESUMO

BACKGROUND: Accumulated experience and advances in device technology have led to the increasing off-label use of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation (PNAR). This study aimed to evaluate the procedural and long-term outcomes of using newer-generation transcatheter heart valves (THVs) versus early-generation self-expanding CoreValve (Medtronic, Minneapolis, USA) to treat PNAR. METHODS: TAVRs were performed with the use of early- (N=15) and newer-generation (N=10) THVs in a total of 25 consecutive PNAR patients at an intermediate-to-high risk for surgical aortic valve replacement [mean Society of Thoracic Surgeons (STS) score of 6.8±4.5]. Procedural and clinical outcomes were reported according to the Valve Academic Research Consortium 2 criteria. The primary end-point of the study was all-cause mortality, myocardial infarction (MI), disabling stroke, and readmission due to heart failure. RESULTS: The device success rate of the newer-generation THVs was significantly higher than that of the early-generation CoreValve (100% vs. 33%, P<0.01), which was mainly driven by less frequent need for implanting a second THV (0% vs. 53%, P<0.01). Although the procedural success rates were 100% for both early- and newer-generation valves, the mean procedure fluoroscopic times which the newer-generation device group required, were significantly shorter (P<0.01) and the amount of contrast medium used in this group, markedly smaller (P<0.01), compared to those of the early-generation CoreValve group. During a median follow-up of 14 months, event-free survival was better in patients undergoing TAVR with the newer-generation THVs, although the differences were not statistically significant (log-rank test, P=0.137). According to multivariate analysis, a higher baseline STS score and longer intensive care unit stays are independent predictors of adverse outcomes. CONCLUSIONS: Evidently, the treatment of PNAR with TAVR using the newer-generation THVs yielded better procedural outcomes and is a valuable therapeutic option in selective patients. KEYWORDS: Transcatheter aortic valve replacement (TAVR); pure native aortic regurgitation (AR); transcatheter heart valves (THVs); procedural and clinical outcomes.

7.
Front Cardiovasc Med ; 9: 973889, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211540

RESUMO

Objectives: This study compared transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in terms of short- and long-term effectiveness. Methods: This retrospective cohort study based on nationwide National Health Insurance claims data and Cause of Death data focused on adult patients (n = 3,643) who received SAVR (79%) or TAVR (21%) between 2015 and 2019. Propensity score overlap weighting was applied to account for selection bias. Primary outcomes included all-cause mortality (ACM), hospitalization for heart failure, and a composite endpoint of major adverse cardiac events (MACE). Secondary outcomes included medical utilization, hospital stay, and total medical costs at index admission for the procedure and in various post-procedure periods. The Cox proportional-hazard model with competing risk was used to investigate survival and incidental health outcomes. Generalized estimation equation (GEE) models were used to estimate differences in the utilization of medical resources and overall costs. Results: After weighting, the mean age of the patients was 77.98 ± 5.86 years in the TAVR group and 77.98 ± 2.55 years in the SAVR group. More than half of the patients were female (53.94%). The incidence of negative outcomes was lower in the TAVR group than in the SAVR group, including 1-year ACM (11.39 vs. 17.98%) and 3-year ACM (15.77 vs. 23.85%). The risk of ACM was lower in the TAVR group (HR [95% CI]: 0.61 [0.44-0.84]; P = 0.002) as was the risk of CV death (HR [95% CI]: 0.47 [0.30-0.74]; P = 0.001) or MACE (HR [95% CI]: 0.66 [0.46-0.96]; P = 0.0274). Total medical costs were significantly higher in the TAVR group than in the SAVR in the first year after the procedure ($1,271.89 ± 4,048.36 vs. $887.20 ± 978.51; P = 0.0266); however, costs were similar in the second and third years after the procedure. The cumulative total medical costs after the procedure were significantly higher in the TAVR group than in the SAVR group (adjusted difference: $420.49 ± 176.48; P = 0.0172). Conclusion: In this real-world cohort of patients with aortic stenosis, TAVR proved superior to SAVR in terms of clinical outcomes and survival with comparable medical utilization after the procedure.

8.
Eur J Echocardiogr ; 12(3): E16, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21044982

RESUMO

Post-caesarean pulmonary embolism (PE) is associated with significant peri-operative morbidity and mortality. This report describes a case of sudden cardiac arrest 2 days post-caesarean due to massive PE diagnosed via bedside transesophageal echocardiography (TEE). Recognition of the PE at the bifurcation of the right and left pulmonary arteries was achieved by real-time three-dimensional TEE, but not two-dimensional TEE. Extracorporeal membrane oxygenation was immediately established and emergent pulmonary thromboembolectomy was performed. The patient was discharged without residual deficits on Day 22 of hospitalization.


Assuntos
Cesárea/efeitos adversos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana/métodos , Parada Cardíaca/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Embolia Pulmonar/diagnóstico por imagem , Adulto , Cesárea/métodos , Terapia Combinada , Ecocardiografia Tridimensional/métodos , Emergências , Feminino , Fibrinolíticos/uso terapêutico , Seguimentos , Parada Cardíaca/etiologia , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Gravidez , Embolia Pulmonar/complicações , Embolia Pulmonar/terapia , Medição de Risco , Trombectomia/métodos , Resultado do Tratamento
9.
Echocardiography ; 28(5): E101-3, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21395670

RESUMO

Residual patent ductus arteriosus (PDA) after surgical ligation is not common, but the anatomy of the residual duct may be distorted by the surgical ligation resulting in a difficult transcatheter closure. Such distorted anatomy of the duct may not be demonstrated by the two-dimensional transesophageal echocardiography (2D TEE). Fortunately, live 3D TEE provided the precise anatomy of the elongated distorted residual duct, and as in the case presented herein, guided the Amplatzer ductal occluder (ADO). We concluded that live 3D TEE provided novel images of complex residual ducts and successful guidance of a ductal occluder.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Ligadura/métodos , Dispositivo para Oclusão Septal , Adulto , Cateterismo Cardíaco/métodos , Terapia Combinada , Feminino , Humanos , Cirurgia Assistida por Computador , Resultado do Tratamento
10.
Echocardiography ; 28(7): E149-51, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21564280

RESUMO

Anomalous origin of the left coronary artery (LCA) from the pulmonary artery (ALCAPA) is a rare congenital defect that presents only infrequently in adults. An adult diagnosed with ALCAPA, heart failure, and mitral regurgitation underwent surgical ligation of the anomalous origin of the LCA from the pulmonary artery (PA) and coronary artery bypass grafting (CABG). The anomalous origin in the PA and proximal segment of the left anterior descending artery (LAD) was successfully delineated via real time, three-dimensional transesophageal echocardiography during surgery. This modality allows for fast assessment and novel views of complex cardiac abnormalities and can aid in perioperative monitoring.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Artéria Pulmonar/anormalidades , Idoso , Angiografia Coronária , Anomalias dos Vasos Coronários/cirurgia , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Período Intraoperatório , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Síndrome
11.
Echocardiography ; 28(1): E12-5, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20618389

RESUMO

Aorto-left ventricular tunnel (ALVT) is a rare congenital malformation. We report an unusual case of ALVT with a large interventricular septal aneurysm causing severe aortic regurgitation and left ventricular outflow obstruction diagnosed with real time three-dimensional transesophageal echocardiography (3D TEE). Real time 3D TEE allows for assessment and novel views of complex cardiac abnormalities and can aid in perioperative monitoring.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Aneurisma Cardíaco/diagnóstico , Comunicação Interventricular/diagnóstico , Adulto , Aneurisma Cardíaco/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Humanos , Masculino , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
12.
Front Cardiovasc Med ; 8: 633369, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34179124

RESUMO

Purpose: In this study, transapical transcatheter mitral valve-in-valve implantation (TAMVI) was compared with surgical redo mitral valve replacement (SRMVR) in terms of clinical outcomes. Methods: We retrospectively identified patients with degenerated mitral bioprosthesis or failed annuloplasty rings who underwent redo SRMVR or TAMVI at our medical center. Clinical outcomes were based on echocardiography results. Results: We retrospectively identified patients with symptomatic mitral bioprosthetic valve dysfunction (n = 58) and failed annuloplasty rings (n = 14) who underwent redo SRMVR (n = 36) or TAMVI (n = 36). The Society of Thoracic Surgeons Predicted Risk of Mortality scores were higher in the TAMVI group (median: 9.52) than in the SRMVR group (median: 5.59) (p-value = 0.02). TAMVI patients were more severe in New York Heart Association (p-value = 0.04). The total procedure time (skin to skin) and length of stay after procedures were significantly shorter in the TAMVI group, and no significant difference in mortality was noted after adjustment for confounding factors (p-value = 0.11). The overall mean mitral valve pressure gradient was lower in the TAMVI group than in the SRMVR group at 24 months (p < 0.01). Both groups presented a decrease in the severity of mitral and tricuspid regurgitation at 3-24 months. Conclusions: In conclusion, the statistical analysis is still not robust enough to make a claim that TAMVI is an appropriate alternative. The outcome of the patient appears only to be related to the patient's pre-operative STS score. Additional multi-center, longitudinal studies are warranted to adequately assess the effect of TAMVI.

13.
Eur J Echocardiogr ; 11(1): 14-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19933520

RESUMO

BACKGROUND: Perioperative monitoring of mitral valve (MV) anatomy, function, and pathology is essential for surgical management of different MV disease. AIMS: To overcome the several potential pitfalls of two-dimensional transesophageal echocardiography (2D TEE) and offline 3D TEE. METHODS: Live 3D TEE was used to assess 73 patients (44 men and 29 women) with Carpentier type II MV regurgitation undergoing MV surgery perioperatively. RESULTS: The isolated segment most frequently involved was A2/P2, but A1or P1 rarely was involved in an isolated lesion or combined lesions. The agreement between 3D TEE finding and surgery was 88% (64/73). In nine patients, the live 3D TEE images revealed more segments or scallops with prolapse than the surgeon noted intraoperatively. CONCLUSIONS: Live 3D TEE allows more sensitivity and was feasible identification of prolapse or flail of individual segments of MV leaflets during surgery. We conclude that live 3D TEE should be regarded as an important adjunct to the standard 2D TEE examination in making decisions about MV surgery.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Adulto Jovem
14.
Echocardiography ; 27(5): 587-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20374269

RESUMO

Endovascular stent grafts have become increasingly used in the management of arterial trauma, chronic vascular occlusive diseases, and deep vein thrombosis (DVT). Here, we describe a case of stent migration to the right heart due to a motor vehicle accident in a patient with iliac venous stent implanted for venous stenosis. Computed tomography (CT) scan imaging identification of a metallic stent was superior to the standard two-dimensional transesophageal echocardiography (TEE) techniques without imaging artifact from reverberation. However, real time three-dimensional (3D) TEE can precisely defined a metallic stent in right heart oriented with shape and direction without consuming time compared to that of CT scanning. The use of 3DTEE can facilitate identification of intracardiac metallic foreign bodies perioperatively in a patient with accident and emergent unstable condition. (Echocardiography 2010;27:587-589).


Assuntos
Acidentes de Trânsito , Embolização Terapêutica/métodos , Migração de Corpo Estranho/cirurgia , Stents/efeitos adversos , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Veia Ilíaca , Masculino , Doenças Vasculares Periféricas/cirurgia , Tomografia Computadorizada por Raios X
16.
Acad Radiol ; 27(3): 381-388, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31160174

RESUMO

RATIONALE AND OBJECTIVES: Computed tomography (CT)-determined skeletal muscle measures have been used for predicting postoperative outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). We investigated the impact of CT-determined muscle quantity (measured as psoas muscle area [PMA] and psoas muscle index [PMI]) and quality (measured as psoas muscle density [PMD]) on hospital length of stay (LOS) after TAVI. METHODS: We retrospectively identified 182 consecutive patients who underwent TAVI between March 2013 and August 2017 with adequate preprocedural CT imaging. Baseline demographic and clinical data, the Society of Thoracic Surgeons score, the essential frailty toolset (EFT) frailty rating, and precontrast PMD, PMA, and PMI were obtained in all study patients. The primary outcome was prolonged postoperative LOS defined as greater than 14 days. RESULTS: Patients with prolonged LOS had a significantly higher Society of Thoracic Surgeons score (p < 0.001) and significantly lower PMD (p < 0.001) than those with LOS ≤14 days. More patients with prolonged LOS had concomitant peripheral vascular disease (p  = 0.001), had undergone percutaneous coronary interventions (p = 0.022), and had an EFT score ≥4 (p < 0.001) compared to those without prolonged LOS. Neither PMA (p = 0.123) nor PMI (p = 0.271) were associated with prolonged LOS. Multivariate analysis identified EFT score ≥4, the presence of peripheral vascular disease, and PMD as independent predictors of prolonged LOS. CONCLUSION: The precontrast CT-determined muscle quality measurement PMD is a simple and objective predictor of prolonged LOS after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tempo de Internação , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Echocardiography ; 26(10): 1250-63, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19929871

RESUMO

We studied 19 patients with pericardial disease using two-dimensional and three-dimensional transthorathic echocardiography (2DTTE and 3DTTE, respectively) in order to determine whether 3DTTE provides incremental value on top of 2DTTE in the evaluation of these patients. With 3DTTE a more comprehensive assessment of pericardial effusion can be made and both the parietal and visceral layers of the pericardium can be visualized en face and examined for pathologies and fibrin deposits. In our series of patients, 3DTTE was superior to 2DTTE in uncovering mass lesions involving the pericardium such as tuberculous granulomas and metastatic disease. Furthermore, it provided a better assessment of the nature of pericardial lesions, such as pericardial and mediastinal hematomas, pericardial cysts, and metastatic disease to the pericardium by sequential cropping of the 3D data sets and visualizing the interior of the lesions in a manner not possible with 2DTTE. It was also valuable in determining the extent of pericardial calcification in pericardial constriction and in measuring the size of pericardial masses. These preliminary results suggest the superiority of 3DTTE over 2DTTE in the evaluation of pericardial diseases and that it provides incremental knowledge to the echocardiographer.


Assuntos
Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Derrame Pericárdico/diagnóstico por imagem , Pericardite/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Sistemas Computacionais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Chin Med Assoc ; 82(11): 827-834, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31693532

RESUMO

BACKGROUND: Data on whether different transcatheter aortic valve replacement (TAVR) devices and delivery approaches can achieve equally favorable outcomes when performed by a single heart team are scarce. We sought to compare the performance and short-term outcomes of three different TAVR devices-self-expanding Medtronic CoreValve (MCV), mechanically expanded Lotus valve, and balloon-expandable Edwards SAPIEN XT (SXT)-for the treatment of severe aortic stenosis (AS) in a single large-volume center in Taiwan. METHODS: We retrospectively reviewed consecutive patients who underwent TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. The composite primary endpoint was combined all-cause mortality, myocardial infarction (MI), or disabling stroke within 180 days. RESULTS: A total of 231 patients (MCV n=112, Lotus n=18, and SXT n=101) were included. The device and procedural success rates were similar among all three TAVR devices. At 30 days, there was no significant difference in all-cause mortality, cardiovascular mortality, periprocedural MI, stroke, major vascular complications, life-threatening bleeding, acute kidney injury (AKI, stage 2/3), or VARC-2 composite early safety endpoints. There was no difference among groups in the rate of primary endpoint within 180 days. Lack of procedural success, presence of acute coronary occlusion during TAVR, and presence of AKI (stage 3) after TAVR were independent predictors of adverse outcomes. CONCLUSION: TAVR using MCV, Lotus, or SXT was associated with similar 30- and 180-day clinical outcomes. The presence of periprocedural complications was one of the main determinants of short-term adverse outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade
19.
J Chin Med Assoc ; 71(8): 428-30, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18772125

RESUMO

Traumatic arteriovenous fistula (AVF) is not an uncommon disorder, but late discovery and the presentation of high-output heart failure is very rare. This patient did not know that he had traumatic AVF after a gunshot injury in the left thigh 14 years ago. The major presentation of the AVF was signs of heart failure. We performed surgical repair after making the diagnosis. The patient recovered with an uneventful course. This report stresses the importance of history-taking and physical examination in making the diagnosis of traumatic AVF.


Assuntos
Fístula Arteriovenosa/complicações , Insuficiência Cardíaca/etiologia , Ferimentos por Arma de Fogo/complicações , Fístula Arteriovenosa/cirurgia , Débito Cardíaco Elevado/etiologia , Artéria Femoral , Veia Femoral , Humanos , Masculino , Pessoa de Meia-Idade
20.
Acta Cardiol ; 61(5): 519-24, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17117751

RESUMO

OBJECTIVES: This hospital-based study was conducted to determine the survival rates of patients after coronary artery bypass grafting (CABG) surgery and the associated prognostic factors related to all-cause mortality during a 7-year follow-up in Taiwan. METHODS AND RESULTS: Between January 1997 and December 2003, the medical records of 1877 patients who underwent primary, isolated CABG surgery were studied. The Kaplan-Meier method was used to estimate survival. Multiple Cox regression was used to investigate the independence of prognostic factors associated with all-cause mortality. Of the 1877 patients who underwent CABG surgery, 192 expired during the 7-year study period. The overall patient survival rate was 85.96% (95% CI: 83.74-88.16). Using multiple Cox regression analysis, in addition to female gender, older age at surgery, pulmonary oedema, longer ischaemic time, longer cardiopulmonary bypass time, and poorer postoperative left ventricular ejection fraction were significant factors associated with all-cause mortality for both men and women. Associated prognostic factors varied by gender. For men, smoking (RR = 2.82, 95% CI: 1.06-4.16), respiratory failure (RR = 6.88, 95% CI: 3.29-14.40) and cardiogenic shock (RR = 4.04, 95% CI: 2.13-7.67) were significantly related to all-cause mortality, but not for women. Sepsis (RR = 8.97,95% CI: 1.19-19.81) and ICU stay (RR = 1.03,95% CI: 1.01-1.05) were significantly related to all-cause mortality among female patients only. CONCLUSIONS: Several gender-related differences were noted pertaining to all-cause mortality and the relationships between smoking, sepsis, respiratory failure, cardiogenic shock, and ICU stay.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Fatores Etários , Idoso , Análise de Variância , Ponte Cardiopulmonar , Isquemia Fria , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Humanos , Hipotermia Induzida , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Projetos de Pesquisa , Fatores de Risco , Fatores Sexuais , Volume Sistólico , Análise de Sobrevida , Taiwan/epidemiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa