Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 280(1): 117-27, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26859255

RESUMO

Purpose To assess the intermanufacturer variability of quantitative models in discriminating cancers with a Gleason score of at least 7 among peripheral zone (PZ) lesions seen at 3-T multiparametric magnetic resonance (MR) imaging. Materials and Methods An institutional review board-approved prospective database of 257 patients who gave written consent and underwent T2-weighted, diffusion-weighted, and dynamic contrast material-enhanced imaging before prostatectomy was retrospectively reviewed. It contained outlined lesions found to be suspicious for malignancy by two independent radiologists and classified as malignant or benign after correlation with prostatectomy whole-mount specimens. One hundred six patients who underwent imaging with 3-T MR systems from two manufacturers were selected (data set A, n = 72; data set B, n = 34). Eleven parameters were calculated in PZ lesions: normalized T2-weighted signal intensity, skewness and kurtosis of T2-weighted signal intensity, T2 value, wash-in rate, washout rate, time to peak (TTP), mean apparent diffusion coefficient (ADC), 10th percentile of the ADC, and skewness and kurtosis of the histogram of the ADC values. Parameters were selected on the basis of their specificity for a sensitivity of 0.95 in diagnosing cancers with a Gleason score of at least 7, and the area under the receiver operating characteristic curve (AUC) for the models was calculated. Results The model of the 10th percentile of the ADC with TTP yielded the highest AUC in both data sets. In data set A, the AUC was 0.90 (95% confidence interval [CI]: 0.85, 0.95) or 0.89 (95% CI: 0.82, 0.94) when it was trained in data set A or B, respectively. In data set B, the AUC was 0.84 (95% CI: 0.74, 0.94) or 0.86 (95% CI: 0.76, 0.95) when it was trained in data set A or B, respectively. No third variable added significantly independent information in any data set. Conclusion The model of the 10th percentile of the ADC with TTP yielded accurate results in discriminating cancers with a Gleason score of at least 7 among PZ lesions at 3 T in data from two manufacturers. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Meios de Contraste , Estudos de Avaliação como Assunto , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa