Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
PLoS One ; 19(4): e0301506, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38687748

RESUMO

BACKGROUND: The WHO recommends routine testing of G6PD activity to guide radical cure in patients with Plasmodium vivax malaria. Females may have intermediate G6PD enzyme activity and to date, only complex diagnostics are able to reliably identify them. The semi-quantitative G6PD diagnostic "One Step G6PD Test" (Humasis, RoK; "RDT") is a lateral flow assay that can distinguish deficient, intermediate, and normal G6PD status and offers a simpler diagnostic alternative. METHODS: G6PD status of participants enrolled in Malinau and Nunukan Regencies and the capital Jakarta was assessed with the RDT, and G6PD activity was measured in duplicate by reference spectrophotometry. The adjusted male median (AMM) of the spectrophotometry measurements was defined as 100% activity; 70% and 30% of the AMM were defined as thresholds for intermediate and deficient G6PD status, respectively. Results were compared to those derived from spectrophotometry at the clinically relevant G6PD activity thresholds of 30% and 70%. RESULTS: Of the 161 participants enrolled, 10 (6.2%) were G6PD deficient and 12 (7.5%) had intermediate G6PD activity by spectrophotometry. At the 30% threshold, the sensitivity of the RDT was 10.0% (95%CI: 0.3-44.5%) with a specificity of 99.3% (95%CI: 96.4-100.0%); the positive predictive value was 50.0% (95%CI: 1.3-98.7%) and the negative predictive value 94.3% (95%CI: 89.5-97.4%). The corresponding figures at the 70% threshold were 22.7% (95%CI: 7.8-45.4%), 100.0% (95%CI: 97.4-100.0%), 100.0% (95%CI: 47.8-100.0%) and 89.1% (95%CI: 83.1-93.5%), respectively. CONCLUSION: While there is a dire need for an easy-to-use, economical, semi-quantitative diagnostic for the point of care, the observed performance of the "One Step G6PD Test" in its current form was insufficient to guide antimalarial treatment.


Assuntos
Deficiência de Glucosefosfato Desidrogenase , Malária Vivax , Humanos , Deficiência de Glucosefosfato Desidrogenase/diagnóstico , Feminino , Indonésia , Masculino , Adulto , Adolescente , Malária Vivax/diagnóstico , Malária Vivax/sangue , Pessoa de Meia-Idade , Adulto Jovem , Sistemas Automatizados de Assistência Junto ao Leito , Criança , Glucosefosfato Desidrogenase/metabolismo , Glucosefosfato Desidrogenase/sangue , Espectrofotometria/métodos , Sensibilidade e Especificidade
2.
PLoS One ; 19(1): e0296708, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38241389

RESUMO

In remote communities, diagnosis of G6PD deficiency is challenging. We assessed the impact of modified test procedures and delayed testing for the point-of-care diagnostic STANDARD G6PD (SDBiosensor, RoK), and evaluated recommended cut-offs. We tested capillary blood from fingerpricks (Standard Method) and a microtainer (BD, USA; Method 1), venous blood from a vacutainer (BD, USA; Method 2), varied sample application methods (Methods 3), and used micropipettes rather than the test's single-use pipette (Method 4). Repeatability was assessed by comparing median differences between paired measurements. All methods were tested 20 times under laboratory conditions on three volunteers. The Standard Method and the method with best repeatability were tested in Indonesia and Nepal. In Indonesia 60 participants were tested in duplicate by both methods, in Nepal 120 participants were tested in duplicate by either method. The adjusted male median (AMM) of the Biosensor Standard Method readings was defined as 100% activity. In Indonesia, the difference between paired readings of the Standard and modified methods was compared to assess the impact of delayed testing. In the pilot study repeatability didn't differ significantly (p = 0.381); Method 3 showed lowest variability. One Nepalese participant had <30% activity, one Indonesian and 10 Nepalese participants had intermediate activity (≥30% to <70% activity). Repeatability didn't differ significantly in Indonesia (Standard: 0.2U/gHb [IQR: 0.1-0.4]; Method 3: 0.3U/gHb [IQR: 0.1-0.5]; p = 0.425) or Nepal (Standard: 0.4U/gHb [IQR: 0.2-0.6]; Method 3: 0.3U/gHb [IQR: 0.1-0.6]; p = 0.330). Median G6PD measurements by Method 3 were 0.4U/gHb (IQR: -0.2 to 0.7, p = 0.005) higher after a 5-hour delay compared to the Standard Method. The definition of 100% activity by the Standard Method matched the manufacturer-recommended cut-off for 70% activity. We couldn't improve repeatability. Delays of up to 5 hours didn't result in a clinically relevant difference in measured G6PD activity. The manufacturer's recommended cut-off for intermediate deficiency is conservative.


Assuntos
Técnicas Biossensoriais , Deficiência de Glucosefosfato Desidrogenase , Oxibato de Sódio , Humanos , Masculino , Glucosefosfato Desidrogenase , Projetos Piloto , Deficiência de Glucosefosfato Desidrogenase/diagnóstico
3.
PLOS Glob Public Health ; 4(7): e0003476, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39028699

RESUMO

Plasmodium vivax remains a challenge for malaria elimination since it forms dormant liver stages (hypnozoites) that can reactivate after initial infection. 8-aminoquinolone drugs kill hypnozoites but can cause severe hemolysis in individuals with Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency. The STANDARD G6PD test (Biosensor) is a novel point-of-care diagnostic capable of identifying G6PD deficiency prior to treatment. In 2021, Cambodia implemented the Biosensor to facilitate radical cure treatment for vivax malaria. To assess the Biosensor's implementation after its national rollout, a mixed-methods study was conducted in eight districts across three provinces in Cambodia. Interviews, focus group discussions, and observations explored stakeholders' experiences with G6PD testing and factors influencing its implementation. Quantitative data illustrative of test implementation were gathered from routine surveillance forms and key proportions derived. Qualitative data were analyzed thematically. The main challenge to implementing G6PD testing was that only 49.2% (437/888) of eligible patients reached health centers for G6PD testing following malaria diagnosis by community health workers. Factors influencing this included road conditions and long distances to the health center, compounded by the cost of seeking further care and patients' perceptions of vivax malaria and its treatment. 93.9% (790/841) of eligible vivax malaria patients who successfully completed referral (429/434) and directly presented to the health center (360/407) were G6PD tested. Key enabling factors included the test's acceptability among health workers and their understanding of the rationale for testing. Only 36.5% (443/1213) of eligible vivax episodes appropriately received primaquine. 70.5% (165/234) of female patients and all children under 20 kilograms never received primaquine. Our findings suggest that access to radical cure requires robust infrastructure and income security, which would likely improve referral rates to health centers enabling access. Bringing treatment closer to patients, through community health workers and nuanced community engagement, would improve access to curative treatment of vivax malaria.

4.
PLoS One ; 19(5): e0297918, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38728310

RESUMO

Quantitative diagnosis of glucose-6-phosphate dehydrogenase (G6PD) deficiency is essential for the safe administration of 8-aminoquinoline based radical cure for the treatment of Plasmodium vivax infections. Here, we present the PreQuine Platform (IVDS, USA), a quantitative biosensor that uses a dual-analyte assay for the simultaneous measurement of Hemoglobin (Hgb) levels and G6PD enzyme activity within the same sample. The platform relies on a downloadable mobile application. The device requires 10µl of whole blood and works with a reflectance-based meter. Comparing the G6PD measurement normalized by Hgb of 12 samples from the PreQuine Platform with reference measurements methods (spectrophotometry, Pointe Scientific, USA and hemoglobin meter, HemoCue, Sweden) showed a positive and significant agreement with a slope of 1.0091 and an intercept of -0.0379 under laboratory conditions. Next steps will be to conduct field trials in Bangladesh, Cambodia, and the USA to assess diagnostic performance, user friendliness and acceptance.


Assuntos
Deficiência de Glucosefosfato Desidrogenase , Glucosefosfato Desidrogenase , Hemoglobinas , Humanos , Glucosefosfato Desidrogenase/metabolismo , Glucosefosfato Desidrogenase/sangue , Deficiência de Glucosefosfato Desidrogenase/diagnóstico , Deficiência de Glucosefosfato Desidrogenase/sangue , Hemoglobinas/análise , Hemoglobinas/metabolismo , Técnicas Biossensoriais/métodos , Malária Vivax/diagnóstico , Malária Vivax/sangue , Aminoquinolinas
5.
Pathogens ; 12(12)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38133328

RESUMO

Early malaria investigators were certainly correct in classifying the species falciparum and the species vivax as belonging to the same genus, Plasmodium [...].

6.
BMJ Glob Health ; 8(12)2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38123228

RESUMO

BACKGROUND: The optimal dosing of primaquine to prevent relapsing Plasmodium vivax malaria in South Asia remains unclear. We investigated the efficacy and safety of different primaquine regimens to prevent P. vivax relapse. METHODS: A systematic review identified P. vivax efficacy studies from South Asia published between 1 January 2000 and 23 August 2021. In a one-stage meta-analysis of available individual patient data, the cumulative risks of P. vivax recurrence at day 42 and 180 were assessed by primaquine total mg/kg dose and duration. The risk of recurrence by day 180 was also determined in a two-stage meta-analysis. Patients with a >25% drop in haemoglobin to <70 g/L, or an absolute drop of >50 g/L between days 1 and 14 were categorised by daily mg/kg primaquine dose. RESULTS: In 791 patients from 7 studies in the one-stage meta-analysis, the day 180 cumulative risk of recurrence was 61.1% (95% CI 42.2% to 80.4%; 201 patients; 25 recurrences) after treatment without primaquine, 28.8% (95% CI 8.2% to 74.1%; 398 patients; 4 recurrences) following low total (2 to <5 mg/kg) and 0% (96 patients; 0 recurrences) following high total dose primaquine (≥5 mg/kg). In the subsequent two-stage meta-analysis of nine studies (3529 patients), the pooled proportions of P. vivax recurrences by day 180 were 12.1% (95% CI 7.7% to 17.2%), 2.3% (95% CI 0.3% to 5.4%) and 0.7% (95% CI 0% to 6.1%), respectively. No patients had a >25% drop in haemoglobin to <70 g/L. CONCLUSIONS: Primaquine treatment led to a marked decrease in P. vivax recurrences following low (~3.5 mg/kg) and high (~7 mg/kg) total doses, with no reported severe haemolytic events. PROSPERO REGISTRATION NUMBER: CRD42022313730.


Assuntos
Antimaláricos , Malária Vivax , Humanos , Primaquina/uso terapêutico , Primaquina/efeitos adversos , Malária Vivax/tratamento farmacológico , Malária Vivax/induzido quimicamente , Malária Vivax/prevenção & controle , Antimaláricos/efeitos adversos , Plasmodium vivax , Recidiva , Ásia Meridional , Hemoglobinas/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa