Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 92(4): 3409-3416, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-31948225

RESUMO

Establishing rapid, simple, and in situ detection of microcystin-LR (MC-LR) in drinking water sources is of significant importance for human health. To ease the situation that current methods cannot address, an open surface droplet microfluidic magnetosensor was designed and validated to quantify MC-LR in reservoir water, which is capable of (1) MC-LR isolation via MC-LR antibody-conjugated magnetic beads, (2) parallel and multistep analytical procedures in 15-array power-free and reusable active droplet microfluidic chips, (3) immunoassay incubation and fluorescence excitation within a miniaturized multifunctional 3D-printing optosensing accessory, and (4) signal read-out and data analysis by a user-friendly Android app. The proposed smartphone-based fluorimetric magnetosensor exhibited a low limit of detection of 1.2 × 10-5 µg/L in the range of 10-4 µg/L to 100 µg/L. This integrated and high throughput platform was utilized to draw an MC-LR contamination map for six reservoirs distributed in the Pearl River delta, Guangdong Province. It promises to be a simple and successful quantification method for MC-LR field detection, bringing many benefits to rapid on-site screening.


Assuntos
Água Potável/química , Toxinas Marinhas/análise , Microcistinas/análise , Técnicas Analíticas Microfluídicas , Fluorometria , Campos Magnéticos , Tamanho da Partícula , Smartphone , Software , Propriedades de Superfície
2.
Food Chem ; 369: 131008, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34500205

RESUMO

In this study, we developed a prussian blue nanoparticles (PBNPs) immunochromatographic assay (ICA) integrated with smartphone-based detection device for ZEN in cereals. PBNPs, as probe labels, were synthesized with properties of controllable structure, environment friendliness, and high affinities to antibody (Ab). PBNPs-ICA quantitative analysis was performed with a hand-held smartphone-based device coupled with a user-friendly and self-programmed detection App. This integrated strategy demonstrated high sensitivity for ZEN with a cut-off value of 10 µg/kg, a detection limit of 0.12 µg/kg, a quantitation limit of 0.27 µg/kg, and recovery rates of 92.0%-105.0% and 88.0%-98.0% for maize and wheat, respectively. The results of 20 naturally contaminated cereal samples showed good correlation (R2>0.99) between LC-MS/MS and developed system. Moreover, the stability experiment revealed that PBNPs-ICA maintained high stability and bioactivity against competitive antigen (Ag). The proposed strategy exhibited great potential for the rapid monitoring of mycotoxins or other small molecule hazards.


Assuntos
Zearalenona , Cromatografia de Afinidade , Cromatografia Líquida , Grão Comestível/química , Ferrocianetos , Contaminação de Alimentos/análise , Limite de Detecção , Smartphone , Espectrometria de Massas em Tandem , Zearalenona/análise
3.
Food Chem ; 366: 130594, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34303207

RESUMO

In this work, a single-emission, dual-enzyme immunofluorometric magnetosensor was fabricated to simultaneously detect three illegal colorants in chili seasoning. Specifically, two enzymatic reactions catalyzed by horse radish peroxidase-labeled Rhodamine (RhB) antibody and glucose oxidase-labeled Sudan dyes (SuDs) antibody were performed within a functional microfluidic chip, leading to production of strongly fluorescent Resorufin. In addition, a compact analyzer assisted by a smartphone was developed to quantify signals. Compared with the available multiplex optical biosensors, this work demonstrated four superiorities: 1) Simple optical structure. Only single wavelength excitation/emission module was needed; 2) High multiplexing capacity through spatial resolution and signal resolution; 3) Precise determination by discriminant analysis; 4) Easy-operated and high-throughput parallel detection on 16-channel chips. Ultralow detection limits for RhB (0.0072 ng/mL), Sudan I (0.0040 ng/mL) and Sudan II (0.0260 ng/mL) were obtained by this magnetosensor, which opens a new approach in field detection of multiplex illegal dyes in food system.


Assuntos
Corantes , Fluorimunoensaio
4.
Biosens Bioelectron ; 158: 112178, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32275211

RESUMO

In this study, a smartphone-based quantitative dual detection mode device, integrated with gold nanoparticles (GNPs) and time-resolved fluorescence microspheres (TRFMs) lateral flow immunoassays (LFIA) for multiplex mycotoxins in cereals were established. The most frequently used visible light and fluorescence detection modes were integrated in one device. A user-friendly application was self-written to rapidly quantify results. GNPs-LFIA and TRFMs-LFIA were used to detect aflatoxin B1 (AFB1), zearalenone (ZEN), deoxynivalenol (DON), T-2 toxin (T-2), and fumonisin B1 (FB1). The visible limits of detection (vLODs) were 10/2.5/1.0/10/0.5, 2.5/0.5/0.5/2.5/0.5 µg/kg for the two methods, respectively. The quantitative limits of detection (qLODs) were 0.59/0.24/0.32/0.9/0.27, 0.42/0.10/0.05/0.75/0.04 µg/kg, respectively. The recoveries of both LFIAs ranged from 84.0%-110.0%. A parallel analysis in 30 naturally contaminated cereal samples was conducted by liquid chromatography-tandem mass spectrometry (LC-MS/MS), the results showed good consistency, indicating the practical reliability of the established methods. The developed two smartphone-based LFIAs provide a promising technique for multiplex, highly sensitive, and on-site detection of mycotoxins.


Assuntos
Grão Comestível , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Imunoensaio/métodos , Micotoxinas , Smartphone , Cromatografia Líquida , Grão Comestível/química , Desenho de Equipamento , Análise de Alimentos/instrumentação , Concentração de Íons de Hidrogênio , Imunoensaio/instrumentação , Limite de Detecção , Micotoxinas/análise , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa