Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 24(23): 7108-7115, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38722094

RESUMO

Diamond is considered the most promising next-generation semiconductor material due to its excellent physical characteristics. It has been more than three decades since the discovery of a special structure named n-diamond. However, despite extensive efforts, its crystallographic structure and properties are still unclear. Here, we show that subdisordered structures in diamond provide an explanation for the structural feature of n-diamond. Monocrystalline diamond with subdisordered structures is synthesized via the chemical vapor deposition method. Atomic-resolution scanning transmission electron microscopy characterizations combined with the picometer-precision peak finder technology and diffraction simulations reveal that picometer-scale shifts of atoms within cells of diamond govern the subdisordered structures. First-principles calculations indicate that the bandgap of diamond decreases rapidly with increasing shifting distance, in accordance with experimental results. These findings clarify the crystallographic structure and electronic properties of n-diamond and provide new insights into the bandgap adjustment in diamond.

2.
Small ; 20(15): e2304886, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38009493

RESUMO

Phase change material (PCM) can provide a battery system with a buffer platform to respond to thermal failure problems. However, current PCMs through compositing inorganics still suffer from insufficient thermal-transport behavior and safety reliability against external force. Herein, a best-of-both-worlds method is reported to allow the PCM out of this predicament. It is conducted by combining a traditional PCM (i.e., paraffin wax/boron nitride) with a spirally weaved polyethylene fiber fabric, just like the traditional PCM is wearing functional underwear. On the one hand, the spirally continuous thermal pathways of polyethylene fibers in the fabric collaborate with the boron nitride network in the PCM, enhancing the through-plane and in-plane thermal conductivity to 10.05 and 7.92 W m-1 K, respectively. On the other, strong polyethylene fibers allow the PCM to withstand a high puncture strength of 47.13 N and tensile strength of 18.45 MPa although above the phase transition temperature. After this typical PCM packs a triple Li-ion battery system, the battery can be promised reliable safety management against both thermal and mechanical abuse. An obvious temperature drop of >10 °C is observed in the battery electrode during the cycling charging and discharging process.

3.
Analyst ; 149(2): 386-394, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38050732

RESUMO

The presence of sulfamethoxazole (SMX) in natural waters has become a significant concern recently because of its detrimental effects on human health and the ecological environment. To address this issue, it is of utmost urgency to develop a reliable method that can determine SMX at ultra-low levels. In our research, we utilized PVP-induced shape control of a hydrothermal synthesis method to fabricate layer-like structured VS2, and employed it as an electrode modification material to prepare an electrochemical sensor for the sensitive determination of SMX. Thus, our prepared VS2 electrodes exhibited a linear range of 0.06-10.0 µM and a limit of detection (LOD) as low as 47.0 nM (S/N = 3) towards SMX detection. Additionally, the electrochemical sensor presented good agreement with the HPLC method, and afforded perfect recovery results (97.4-106.8%) in the practical analysis. The results validated the detection accuracy of VS2 electrodes, and demonstrated their successful applicability toward the sensitive determination of SMX in natural waters. In conclusion, this research provides a promising approach for the development of electrochemical sensors based on VS2 composite materials.


Assuntos
Antibacterianos , Compostos de Vanádio , Humanos , Sulfametoxazol , Técnicas Eletroquímicas/métodos , Eletrodos , Limite de Detecção
4.
Sensors (Basel) ; 24(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38733009

RESUMO

Recent advancements in polymer-assisted layer-by-layer (LbL) fabrication have revolutionized the development of wearable sensors for health monitoring. LbL self-assembly has emerged as a powerful and versatile technique for creating conformal, flexible, and multi-functional films on various substrates, making it particularly suitable for fabricating wearable sensors. The incorporation of polymers, both natural and synthetic, has played a crucial role in enhancing the performance, stability, and biocompatibility of these sensors. This review provides a comprehensive overview of the principles of LbL self-assembly, the role of polymers in sensor fabrication, and the various types of LbL-fabricated wearable sensors for physical, chemical, and biological sensing. The applications of these sensors in continuous health monitoring, disease diagnosis, and management are discussed in detail, highlighting their potential to revolutionize personalized healthcare. Despite significant progress, challenges related to long-term stability, biocompatibility, data acquisition, and large-scale manufacturing are still to be addressed, providing insights into future research directions. With continued advancements in polymer-assisted LbL fabrication and related fields, wearable sensors are poised to improve the quality of life for individuals worldwide.


Assuntos
Técnicas Biossensoriais , Polímeros , Dispositivos Eletrônicos Vestíveis , Polímeros/química , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos
5.
Small ; 19(52): e2303933, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37574266

RESUMO

Exploiting novel strategies for simultaneously harvesting ubiquitous, renewable, and easily accessible solar energy based on the photothermal effect, and efficiently storing the acquired thermal energy plays a vital role in revolutionizing the current fossil fuel-dominating energy structure. Developing black phosphorene-based phase-change composites with optimized photothermal conversion efficiencyand high latent heat is the most promising way to achieve efficient solar energy harvesting and rapid thermal energy storage. However, exfoliating high-quality black phosphorene nanosheets  remains challenging, Furthermore, an efficient strategy that can construct the aligned black phosphorene frameworks to maximize thermal conductivity enhancement is still lacking. Herein, high-quality black phosphorene nanosheets are prepared by an optimized exfoliating strategy. Meanwhile, by regulating the temperature gradient during freeze-casting, the framework consisting of shipshape aligned black phosphorene at long-range is successfully fabricated, improving the thermal conductivity of the poly(ethylene glycol) matrix up to 1.81 W m-1  K-1 at 20 vol% black phosphorene loading. The framework also endows the composite with excellent phase-change material encapsulation capacity and  high latent heat of 103.91 J g-1 . It is envisioned that the work advances the paradigm of contrasting frameworks with nanosheets toward controllable structure thermal enhancement of the composites.

6.
Nanotechnology ; 34(28)2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37059077

RESUMO

As an ultra-wide bandgap semiconductor, hexagonal boron nitride (h-BN) has drawn great attention in solar-blind photodetection owing to its wide bandgap and high thermal conductivity. In this work, a metal-semiconductor-metal structural two-dimensional h-BN photodetector was fabricated by using mechanically exfoliated h-BN flakes. The device achieved an ultra-low dark current (16.4 fA), high rejection ratio (R205nm/R280nm= 235) and high detectivity up to 1.28 × 1011Jones at room temperature. Moreover, due to the wide bandgap and high thermal conductivity, the h-BN photodetector showed good thermal stability up to 300 °C, which is hard to realize for common semiconductor materials. The high detectivity and thermal stability of h-BN photodetector in this work showed the potential applications of h-BN photodetectors working in solar-blind region at high temperature.

7.
Sensors (Basel) ; 23(20)2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37896749

RESUMO

Bisphenol A (BPA) is an industrial chemical used extensively in plastics and resins. However, its endocrine-disrupting properties pose risks to human health and the environment. Thus, accurate and rapid detection of BPA is crucial for exposure monitoring and risk mitigation. Molecularly imprinted electrochemical sensors (MIES) have emerged as a promising tool for BPA detection due to their high selectivity, sensitivity, affordability, and portability. This review provides a comprehensive overview of recent advances in MIES for BPA detection. We discuss the operating principles, fabrication strategies, materials, and methods used in MIES. Key findings show that MIES demonstrate detection limits comparable or superior to conventional methods like HPLC and GC-MS. Selectivity studies reveal excellent discrimination between BPA and structural analogs. Recent innovations in nanomaterials, novel monomers, and fabrication techniques have enhanced sensitivity, selectivity, and stability. However, limitations exist in reproducibility, selectivity, and stability. While challenges remain, MIES provide a low-cost portable detection method suitable for on-site BPA monitoring in diverse sectors. Further optimization of sensor fabrication and characterization will enable the immense potential of MIES for field-based BPA detection.


Assuntos
Impressão Molecular , Humanos , Impressão Molecular/métodos , Reprodutibilidade dos Testes , Técnicas Eletroquímicas/métodos , Plásticos
8.
Sensors (Basel) ; 23(5)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36905070

RESUMO

A sensitive and selective electrochemical dopamine (DA) sensor has been developed using gold nanoparticles decorated marimo-like graphene (Au NP/MG) as a modifier of the glassy carbon electrode (GCE). Marimo-like graphene (MG) was prepared by partial exfoliation on the mesocarbon microbeads (MCMB) through molten KOH intercalation. Characterization via transmission electron microscopy confirmed that the surface of MG is composed of multi-layer graphene nanowalls. The graphene nanowalls structure of MG provided abundant surface area and electroactive sites. Electrochemical properties of Au NP/MG/GCE electrode were investigated by cyclic voltammetry and differential pulse voltammetry techniques. The electrode exhibited high electrochemical activity towards DA oxidation. The oxidation peak current increased linearly in proportion to the DA concentration in a range from 0.02 to 10 µM with a detection limit of 0.016 µM. The detection selectivity was carried out with the presence of 20 µM uric acid in goat serum real samples. This study demonstrated a promising method to fabricate DA sensor-based on MCMB derivatives as electrochemical modifiers.

9.
Molecules ; 28(18)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37764496

RESUMO

Graphene is an emerging nanomaterial increasingly being used in electrochemical biosensing applications owing to its high surface area, excellent conductivity, ease of functionalization, and superior electrocatalytic properties compared to other carbon-based electrodes and nanomaterials, enabling faster electron transfer kinetics and higher sensitivity. Graphene electrochemical biosensors may have the potential to enable the rapid, sensitive, and low-cost detection of cancer biomarkers. This paper reviews early-stage research and proof-of-concept studies on the development of graphene electrochemical biosensors for potential future cancer diagnostic applications. Various graphene synthesis methods are outlined along with common functionalization approaches using polymers, biomolecules, nanomaterials, and synthetic chemistry to facilitate the immobilization of recognition elements and improve performance. Major sensor configurations including graphene field-effect transistors, graphene modified electrodes and nanocomposites, and 3D graphene networks are highlighted along with their principles of operation, advantages, and biosensing capabilities. Strategies for the immobilization of biorecognition elements like antibodies, aptamers, peptides, and DNA/RNA probes onto graphene platforms to impart target specificity are summarized. The use of nanomaterial labels, hybrid nanocomposites with graphene, and chemical modification for signal enhancement are also discussed. Examples are provided to illustrate applications for the sensitive electrochemical detection of a broad range of cancer biomarkers including proteins, circulating tumor cells, DNA mutations, non-coding RNAs like miRNA, metabolites, and glycoproteins. Current challenges and future opportunities are elucidated to guide ongoing efforts towards transitioning graphene biosensors from promising research lab tools into mainstream clinical practice. Continued research addressing issues with reproducibility, stability, selectivity, integration, clinical validation, and regulatory approval could enable wider adoption. Overall, graphene electrochemical biosensors present powerful and versatile platforms for cancer diagnosis at the point of care.


Assuntos
Grafite , Neoplasias , Reprodutibilidade dos Testes , Carbono , Anticorpos , Biomarcadores Tumorais , Neoplasias/diagnóstico
10.
Sensors (Basel) ; 21(4)2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33572293

RESUMO

Chloramphenicol (CAP) is a harmful compound associated with human hematopathy and neuritis, which was widely used as a broad-spectrum antibacterial agent in agriculture and aquaculture. Therefore, it is significant to detect CAP in aquatic environments. In this work, carbon nanotubes/silver nanowires (CNTs/AgNWs) composite electrodes were fabricated as the CAP sensor. Distinguished from in situ growing or chemical bonding noble metal nanomaterials on carbon, this CNTs/AgNWs composite was formed by simple solution blending. It was demonstrated that CNTs and AgNWs both contributed to the redox reaction of CAP in dynamics, and AgNWs was beneficial in thermodynamics as well. The proposed electrochemical sensor displayed a low detection limit of up to 0.08 µM and broad linear range of 0.1-100 µM for CAP. In addition, the CNTs/AgNWs electrodes exhibited good performance characteristics of repeatability and reproducibility, and proved suitable for CAP analysis in real water samples.


Assuntos
Cloranfenicol , Nanotubos de Carbono , Nanofios , Cloranfenicol/análise , Técnicas Eletroquímicas , Eletrodos , Humanos , Reprodutibilidade dos Testes , Prata
11.
Analyst ; 145(8): 3073-3080, 2020 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-32142088

RESUMO

Herein we combine the sandwich immunoreaction at a vertically aligned single-walled carbon nanotube (SWCNT)-based immunosensor and the enzymatically catalytic deposition of gold nanoparticles (Au NPs) by a gold nanoprobe to develop a novel electrochemical immunosensing method. The vertically arranged nanostructure was prepared through the covalent linking of terminally carboxylated SWCNTs at an aryldiazonium-modified electrode. It not only provides an excellent platform for the high density immobilization of antibodies to obtain the immunosensor but also serves as useful molecular wires to accelerate electron transfer during the electrochemical immunosensing process. Meanwhile, the enzymatic reaction of the nanoprobe prepared by surface functionalization of the nanocarrier of Au NPs by high-content glucoamylases can catalyze the deposition of a large number of Au NPs at the immunosensor. The electrochemical stripping analysis of these nanoparticles enabled the convenient signal transduction of the method. Due to the sensitive gold stripping analysis at the vertically aligned SWCNTs and the multi-enzyme signal amplification of the nanoprobe, the electrochemical signal response was greatly enhanced. Thus, the method can be used for the ultrasensitive detection of the tumor biomarker of carcinoembryonic antigen in a wide linear range of 5 orders of magnitude with a low detection limit of 0.48 pg mL-1. Considering its obvious performance superiorities, this immunosensing method exhibits an extensive prospect for practical applications.


Assuntos
Biomarcadores Tumorais/sangue , Antígeno Carcinoembrionário/sangue , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Nanopartículas Metálicas/química , Nanotubos de Carbono/química , Anticorpos Imobilizados/imunologia , Aspergillus niger/enzimologia , Biomarcadores Tumorais/imunologia , Antígeno Carcinoembrionário/imunologia , Técnicas Eletroquímicas/instrumentação , Eletrodos , Glucana 1,4-alfa-Glucosidase/química , Ouro/química , Humanos , Limite de Detecção
12.
Nanotechnology ; 31(11): 115502, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-31778981

RESUMO

Surface modification is a simple and effective means to promote the sensing performance of metal oxide semiconductor-based gas sensors. Marigold-shaped ZnO nanoflowers are fabricated via a simple precipitation reaction and subsequently catalytically modified with RuO2 on the surface through an ethylene glycol solvothermal treatment. The experimental results have proven that a very low content of Ru on the surface of ZnO exists in an oxidized state. However, the gas response of the sensor based on RuO2-modified ZnO is remarkably improved by 17 times to 100 ppm acetone with the decrease of optimal operating temperature from 219 °C-172 °C and reduction in recovery time from 79-52 s. The sensing enhancement mechanism of surface modification can be attributed to the formation of massive small heterostructure between p-type RuO2 ultrasmall nanoparticles and n-type ZnO as well as the catalytic effect of Ru4+ and a rougher surface.

13.
Mikrochim Acta ; 187(6): 361, 2020 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-32468206

RESUMO

A magnetic bead (MB)-based sandwich biorecognition reactions is combined with a gold nanoprobe-induced homogenous synthesis of molybdophosphate to develop a novel bioassay method for the electrochemical detection of the tumor biomarker of carcinoembryonic antigen (CEA). The nanoprobe is prepared through the specific loading of numerous alkaline phosphatase (ALP)-functionalized gold nanoparticles (Au NPs) on a double-stranded DNA (dsDNA) produced by the CEA aptamer-triggered hybridization chain reaction (HCR). Both the large amounts of PO43- produced by the ALP catalytic hydrolysis of pyrophosphate and the phosphate backbones of dsDNA can react with the added MoO42- to generate electroactive molybdophosphates. So, the gold nanoprobe was used for signal tracing of the sandwich bioassay of CEA at a constructed antibody-functionalized MB platform. The sensitive electrochemical measurement of molybdophosphate produced from the quantitatively captured nanoprobes at a carbon nanotube-modified electrode (measured at about 0.12 V vs. Ag/AgCl, 3 M KCl) enabled the convenient signal transduction of the method. Due to the dually enhanced synthesis of molybdophosphate by the HCR and multi-enzyme Au NP nanotags, this method shows a wide linear range from 0.05 pg mL-1 to 10 ng mL-1 along with a low detection limit of 0.027 pg mL-1. In addition, the MB-based biorecognition reaction and the homogeneous synthesis of molybdophosphate are much convenient in manipulations. These excellent performances decide the extensive application potentials of the method. Graphical abstract A magnetic bead-based bioassay method was simply developed for the electrochemical detection of carcinoembryonic antigen. The dually enhanced homogenous synthesis of molybdophosphate by hybridization chain reaction (HCR) and enzyme nanotags and the sensitive electrochemical measurement of molybdophosphate at a carbon nanotube (CNT)-electrode enable ultrasensitive signal transduction of the method.


Assuntos
Fosfatase Alcalina/química , Antígeno Carcinoembrionário/sangue , Técnicas Eletroquímicas/métodos , Molibdênio/química , Ácidos Fosfóricos/química , Anticorpos Imobilizados/imunologia , Aptâmeros de Nucleotídeos/química , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/química , Antígeno Carcinoembrionário/química , Antígeno Carcinoembrionário/imunologia , DNA/química , Enzimas Imobilizadas/química , Ouro/química , Humanos , Imunoensaio/métodos , Separação Imunomagnética , Limite de Detecção , Nanopartículas Metálicas/química , Técnicas de Amplificação de Ácido Nucleico , Ácidos Fosfóricos/síntese química
14.
Mult Scler ; 25(5): 644-652, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-29569515

RESUMO

BACKGROUND: Multiple sclerosis (MS) is a multifactorial disease of unknown origin. The current paradigm is that disease develops in genetically susceptible individuals, influenced by environmental factors. Epstein-Barr virus (EBV) and human herpesvirus 6 (HHV-6) have particularly strong associations with the disease. Both viruses are typically acquired during childhood, decades before MS presents. However, in patients with pediatric MS, the temporal window between viral acquisition and disease onset is shortened, which may provide insights into the association of herpesviruses with MS. OBJECTIVE: To compare the frequency of EBV and HHV-6 in the saliva of a cohort of pediatric MS patients and age-matched controls. METHODS: The study enrolled 32 pediatric MS patients and 42 controls and evaluated saliva for HHV-6 u57 and EBV lmp-1 amplification by droplet digital polymerase chain reaction (ddPCR). RESULTS: Pediatric MS patients did not differ from controls in the frequency or magnitude of salivary viral shedding. During the assessment of EBV positivity, distinct profiles emerged that correlated with target amplicon mutations. CONCLUSIONS: None of these mutations were evident in EBV-positive samples from pediatric MS patients, whereas they were present in pediatric controls, in addition to MS and control adults, suggesting differential host-immune control of EBV in this pediatric MS cohort.


Assuntos
Infecções por Vírus Epstein-Barr/epidemiologia , Herpesviridae/patogenicidade , Esclerose Múltipla/epidemiologia , Esclerose Múltipla/virologia , Saliva/virologia , Adulto , Criança , Estudos de Coortes , Feminino , Herpesvirus Humano 4/imunologia , Herpesvirus Humano 4/patogenicidade , Humanos , Masculino , Prevalência , Eliminação de Partículas Virais/imunologia
15.
Mikrochim Acta ; 186(4): 222, 2019 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-30847573

RESUMO

Hierarchical Co3O4@NiMoO4 core-shell nanowires (NWs) were synthesized utilizing a two-step hydrothermal method. The NWs show a high chemiresistive response (at a temperature of 255 °C) to xylene, with an Rgas/Rair ratio of 24.6 at 100 ppm xylene, while the response towards toluene, benzene, ethanol, and acetone, CO, H2S and NO2 is much weaker. In contrast, pure Co3O4 nanowires exhibit weak responses to all the vapors/gases and poor selectivity. The new NW sensor displays an almost linear response (1-100 ppm) to xylene and a lower detection limit of 424 ppb. The remarkable gas sensing characteristics are attributed to the synergistic catalytic effect and the formation of a heterostructure between Co3O4 and NiMoO4. Graphical abstract Schematic presentation of a xylene vapor chemiresistive sensor based on Co3O4@NiMoO4 core-shell nanowires. The Co3O4@NiMoO4 core-shell nanowires-based sensor exhibits a high response (24.6) to 100 ppm xylene at 255 °C and high response/recovery speed (13-15 and 25-29 s).

16.
Mikrochim Acta ; 186(7): 413, 2019 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-31187252

RESUMO

The authors of "A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol (Microchimica Acta 185, no. 2 (2018): 87)" wish to replace the incorrect images of Fig. 1C, 1D shown below.

17.
Sensors (Basel) ; 19(13)2019 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-31284502

RESUMO

The development of accurate, reliable devices for glucose detection has drawn much attention from the scientific community over the past few years. Here, we report a single-step method to fabricate Ni nanoparticle-modified graphene-diamond hybrid electrodes via a catalytic thermal treatment, by which the graphene layers are directly grown on the diamond surface using Ni thin film as a catalyst, meanwhile, Ni nanoparticles are formed in situ on the graphene surface due to dewetting behavior. The good interface between the Ni nanoparticles and the graphene guarantees efficient charge transfer during electrochemical detection. The fabricated electrodes exhibit good glucose sensing performance with a low detection limit of 2 µM and a linear detection range between 2 µM-1 mM. In addition, this sensor shows great selectivity, suggesting potential applications for sensitive and accurate monitoring of glucose in human blood.


Assuntos
Técnicas Eletroquímicas/instrumentação , Eletrodos , Glucose/análise , Nanopartículas Metálicas/química , Níquel/química , Catálise , Diamante/química , Técnicas Eletroquímicas/métodos , Grafite/química , Limite de Detecção , Oxirredução , Espectroscopia Fotoeletrônica , Sensibilidade e Especificidade , Análise Espectral Raman
18.
Nano Lett ; 18(7): 4611-4617, 2018 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-29911386

RESUMO

Nanostructures in silicon (Si) induced by phase transformations have been investigated during the past 50 years. Performances of nanostructures are improved compared to that of bulk counterparts. Nevertheless, the confinement and loading conditions are insufficient to machine and fabricate high-performance devices. As a consequence, nanostructures fabricated by nanoscale deformation at loading speeds of m/s have not been demonstrated yet. In this study, grinding or scratching at a speed of 40.2 m/s was performed on a custom-made setup by an especially designed diamond tip (calculated stress under the diamond tip in the order of 5.11 GPa). This leads to a novel approach for the fabrication of nanostructures by nanoscale deformation at loading speeds of m/s. A new deformation-induced nanostructure was observed by transmission electron microscopy (TEM), consisting of an amorphous phase, a new tetragonal phase, slip bands, twinning superlattices, and a single crystal. The formation mechanism of the new phase was elucidated by ab initio simulations at shear stress of about 2.16 GPa. This approach opens a new route for the fabrication of nanostructures by nanoscale deformation at speeds of m/s. Our findings provide new insights for potential applications in transistors, integrated circuits, diodes, solar cells, and energy storage systems.

19.
Mikrochim Acta ; 190(5): 183, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-37067606
20.
Mikrochim Acta ; 186(1): 15, 2018 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-30542980

RESUMO

The authors describe a nanocomposite that was obtained by in-situ deposition of CdS nanocrystals on mesoporous silica nanospheres (MSNs), and its use in an electrochemical immunoassay of human immunoglobulin G (HIgG). The MCN/CdS nanocomposite was covalently modified with the antibodies against HIgG and then employed in a voltammetric immunoassay at antibody-functionalized magnetic beads. Through sandwich immunoreaction, the MCN/CdS nanoprobes are quantitatively captured onto the magnetic beads where numerous Cd(II) ions are released in an acidic solution. The Cd(II) can be detected by anodic stripping voltammetry at a typical working potential of -0.78 V (vs. Ag/AgCl). In combination with the high loading of CdS on MSNs, the use of the stripping voltammetric analysis renders the method high sensitivity. A wide linear range varying from 0.01 to 100 ng mL-1 is obtained for HIgG detection with a lower detection limit at 2.9 pg mL-1. In addition, the preparation of the nanoprobe is inexpensive. The magnetic bead-based assay does not require complex manipulations. Therefore, this method is deemed to possess a wide scope in that it may be applied to other immunoassays. Graphical abstract Graphical Abstract contains poor quality and small text inside the artwork. Please do not re-use the file that we have rejected or attempt to increase its resolution and re-save. It is originally poor, therefore, increasing the resolution will not solve the quality problem. We suggest that you provide us the original format. We prefer replacement figures containing vector/editable objects rather than embedded images. Preferred file formats are eps, ai, tiff and pdf.A TIFF file at 900 dpi resolution of the Graphical Abstract has been attached via this online system. Schematic presentation of the preparation of the mesoporous silica nanosphere (MSN)/CdS nanocomposite for the electrochemical immunoassay of human IgG at magnetic beads. The high decoration of CdS on MSN and the stripping voltammetric analysis of Cd(II) ions render the method high sensitivity.


Assuntos
Cádmio/análise , Imunoensaio/métodos , Imunoglobulina G/análise , Compostos de Cádmio/química , Técnicas Eletroquímicas , Humanos , Nanopartículas/química , Nanosferas/química , Dióxido de Silício/química , Sulfetos/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa