1.
J Formos Med Assoc ; 122(9): 880-889, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37149422

RESUMO

BACKGROUND: Weaning rate is an important quality indicator of care for patients with prolonged mechanical ventilation (PMV). However, diverse clinical characteristics often affect the measured rate. A risk-adjusted control chart may be beneficial for assessing the quality of care. METHODS: We analyzed patients with PMV who were discharged between 2018 and 2020 from a dedicated weaning unit at a medical center. We generated a formula to estimate monthly weaning rates using multivariate logistic regression for the clinical, laboratory, and physiologic characteristics upon weaning unit admission in the first two years (Phase I). We then applied both multiplicative and additive models for adjusted p-charts, displayed in both non-segmented and segmented formats, to assess whether special cause variation existed. RESULTS: A total of 737 patients were analyzed, including 503 in Phase I and 234 in Phase II, with average weaning rates of 59.4% and 60.3%, respectively. The p-chart of crude weaning rates did not show special cause variation. Ten variables from the regression analysis were selected for the formula to predict individual weaning probability and generate estimated weaning rates in Phases I and II. For risk-adjusted p-charts, both multiplicative and additive models showed similar findings and no special cause variation. CONCLUSION: Risk-adjusted control charts generated using a combination of multivariate logistic regression and control chart-adjustment models may provide a feasible method to assess the quality of care in the setting of PMV with standard care protocols.


Assuntos
Respiração Artificial , Desmame do Respirador , Humanos , Unidades de Terapia Intensiva , Alta do Paciente , Modelos Logísticos
2.
J Formos Med Assoc ; 122(11): 1132-1140, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37169656

RESUMO

BACKGROUND: To analyze the predictability of an automatic tube compensation (ATC) screening test compared with the conventional direct liberation test performed before continuous oxygen support for MV liberation. METHODS: This retrospective study analyzed tracheostomized patients with prolonged MV in a weaning unit of a medical center in Taiwan. In March 2020, a four-day ATC test to screen patient eligibility for ventilator liberation was implemented, intended to replace the direct liberation test. We compared the predictive accuracy of these two screening methods on the relevant outcomes in the two years before and one year after the implementation of this policy. RESULTS: Of the 403 cases, 246 (61%) and 157 (39%) received direct liberation and ATC screening tests, respectively. These two groups had similar outcomes: successful weaning upon leaving the Respiratory Care Center (RCC), success on day 100 of MV, success at hospital discharge, and in-hospital survival. Receiver operating characteristic curve analysis showed that the ATC screening test had better predictive ability than the direct liberation test for RCC weaning, discharge weaning, 100-day weaning, and in-hospital survival. CONCLUSION: This closed-circuit ATC screening test before ventilator liberation is a feasible and valuable method for screening PMV patients undergoing ventilator liberation in the pandemic era. Its predictability for a comparison with the open-circuit oxygen test requires further investigation.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Respiração Artificial , Estudos Retrospectivos , Desmame do Respirador/métodos , Oxigênio