Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(3): 863-872, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36576323

RESUMO

AIMS: There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. METHODS AND RESULTS: We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097-0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639-2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). CONCLUSION: The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. TRIAL REGISTRATION: Clinical Trials Registration: NCT02459574.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Antiarrítmicos/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Hospitais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
2.
J Cardiovasc Electrophysiol ; 31(11): 2964-2974, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32976636

RESUMO

AIMS: A prolonged PR interval may adversely affect ventricular filling and, therefore, cardiac function. AV delay can be corrected using right ventricular pacing (RVP), but this induces ventricular dyssynchrony, itself harmful. Therefore, in intermittent heart block, pacing avoidance algorithms are often implemented. We tested His-bundle pacing (HBP) as an alternative. METHODS: Outpatients with a long PR interval (>200 ms) and intermittent need for ventricular pacing were recruited. We measured within-patient differences in high-precision hemodynamics between AV-optimized RVP and HBP, as well as a pacing avoidance algorithm (Managed Ventricular Pacing [MVP]). RESULTS: We recruited 18 patients. Mean left ventricular ejection fraction was 44.3 ± 9%. Mean intrinsic PR interval was 266 ± 42 ms and QRS duration was 123 ± 29 ms. RVP lengthened QRS duration (+54 ms, 95% CI 42-67 ms, p < .0001) while HBP delivered a shorter QRS duration than RVP (-56 ms, 95% CI -67 to -46 ms, p < .0001). HBP did not increase QRS duration (-2 ms, 95% CI -8 to 13 ms, p = .6). HBP improved acute systolic blood pressure by mean of 5.0 mmHg (95% CI 2.8-7.1 mmHg, p < .0001) compared to RVP and by 3.5 mmHg (95% CI 1.9-5.0 mmHg, p = .0002) compared to the pacing avoidance algorithm. There was no significant difference in hemodynamics between RVP and ventricular pacing avoidance (p = .055). CONCLUSIONS: HBP provides better acute cardiac function than pacing avoidance algorithms and RVP, in patients with prolonged PR intervals. HBP allows normalization of prolonged AV delays (unlike pacing avoidance) and does not cause ventricular dyssynchrony (unlike RVP). Clinical trials may be justified to assess whether these acute improvements translate into longer term clinical benefits in patients with bradycardia indications for pacing.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Algoritmos , Hemodinâmica , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
Europace ; 21(9): 1422-1431, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30820561

RESUMO

AIMS: Abnormal rate adaptation of the action potential is proarrhythmic but is difficult to measure with current electro-anatomical mapping techniques. We developed a method to rapidly quantify spatial discordance in whole heart activation in response to rate cycle length changes. We test the hypothesis that patients with underlying channelopathies or history of aborted sudden cardiac death (SCD) have a reduced capacity to maintain uniform activation following exercise. METHODS AND RESULTS: Electrocardiographical imaging (ECGI) reconstructs >1200 electrograms (EGMs) over the ventricles from a single beat, providing epicardial whole heart activation maps. Thirty-one individuals [11 SCD survivors; 10 Brugada syndrome (BrS) without SCD; and 10 controls] with structurally normal hearts underwent ECGI vest recordings following exercise treadmill. For each patient, we calculated the relative change in EGM local activation times (LATs) between a baseline and post-exertion phase using custom written software. A ventricular conduction stability (V-CoS) score calculated to indicate the percentage of ventricle that showed no significant change in relative LAT (<10 ms). A lower score reflected greater conduction heterogeneity. Mean variability (standard deviation) of V-CoS score over 10 consecutive beats was small (0.9 ± 0.5%), with good inter-operator reproducibility of V-CoS scores. Sudden cardiac death survivors, compared to BrS and controls, had the lowest V-CoS scores post-exertion (P = 0.011) but were no different at baseline (P = 0.50). CONCLUSION: We present a method to rapidly quantify changes in global activation which provides a measure of conduction heterogeneity and proof of concept by demonstrating SCD survivors have a reduced capacity to maintain uniform activation following exercise.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração/fisiopatologia , Estresse Fisiológico/fisiologia , Fibrilação Ventricular/fisiopatologia , Potenciais de Ação/fisiologia , Adulto , Síndrome de Brugada/diagnóstico por imagem , Estudos de Casos e Controles , Eletrocardiografia/métodos , Teste de Esforço , Feminino , Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Sobreviventes , Teste da Mesa Inclinada , Tomografia Computadorizada por Raios X , Fibrilação Ventricular/diagnóstico por imagem , Dispositivos Eletrônicos Vestíveis
4.
Pacing Clin Electrophysiol ; 42(2): 257-264, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30569504

RESUMO

INTRODUCTION: A spontaneous type I electrocardiogram (ECG) pattern and/or unheralded syncope are conventionally used as risk markers for primary prevention of sudden cardiac arrest/death (SCA/SCD) in Brugada syndrome (BrS). In this study, we determine the prevalence of conventional and newer markers of risk in those with and without previous aborted SCA events. METHODS: All patients with BrS were identified at our institute. History of symptoms was obtained from medical tests or from interviews. Other markers of risk were also obtained, such as presence of (1) spontaneous type I pattern, (2) fractionated QRS (fQRS), (3) early repolarization (ER) pattern, (4) late potentials on signal-averaged ECG (SAECG), and (5) response to programmed electrical stimulation. RESULTS: In 133 patients with Bars, 10 (7%) patients (mean age = 39 ± 11 years; nine males) were identified with a previous ventricular fibrillation/ventricular tachycardia episode (n = 8) or requiring cardio-pulmonary resuscitation (n = 2). None of these patients had a prior history of syncope before their SCA event. Only two (20%) patients reported a history of palpitations or dizziness. None had apneic breathing and three (30%) patients had a family history of SCA. From their ECGs, a spontaneous pattern was only found in one (10%) of these patients. Further, 10% of patients had fQRS, 17% had late potentials on SAECG, 20% had deep S waves in lead I, and 10% had an ER pattern in the peripheral leads. No significant differences were observed in the non-SCA group. CONCLUSION: The majority of BrS patients with previous aborted SCA events did not have a spontaneous type I and/or prior history of syncope. Conventional and newer markers of risk appear to only have limited ability to predict SCA.


Assuntos
Síndrome de Brugada/complicações , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Síncope/etiologia , Síncope/fisiopatologia , Adulto , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Sobreviventes , Síncope/epidemiologia
5.
J Cardiovasc Electrophysiol ; 29(1): 115-126, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091329

RESUMO

BACKGROUND: Models of cardiac arrhythmogenesis predict that nonuniformity in repolarization and/or depolarization promotes ventricular fibrillation and is modulated by autonomic tone, but this is difficult to evaluate in patients. We hypothesize that such spatial heterogeneities would be detected by noninvasive ECG imaging (ECGi) in sudden cardiac death (SCD) survivors with structurally normal hearts under physiological stress. METHODS: ECGi was applied to 11 SCD survivors, 10 low-risk Brugada syndrome patients (BrS), and 10 controls undergoing exercise treadmill testing. ECGi provides whole heart activation maps and >1,200 unipolar electrograms over the ventricular surface from which global dispersion of activation recovery interval (ARI) and regional delay in conduction were determined. These were used as surrogates for spatial heterogeneities in repolarization and depolarization. Surface ECG markers of dispersion (QT and Tpeak-end intervals) were also calculated for all patients for comparison. RESULTS: Following exertion, the SCD group demonstrated the largest increase in ARI dispersion compared to BrS and control groups (13 ± 8 ms vs. 4 ± 7 ms vs. 4 ± 5 ms; P = 0.009), with baseline dispersion being similar in all groups. In comparison, surface ECG markers of dispersion of repolarization were unable to discriminate between the groups at baseline or following exertion. Spatial heterogeneities in conduction were also present following exercise but were not significantly different between SCD survivors and the other groups. CONCLUSION: Increased dispersion of repolarization is apparent during physiological stress in SCD survivors and is detectable with ECGi but not with standard ECG parameters. The electrophysiological substrate revealed by ECGi could be the basis of alternative risk-stratification techniques.


Assuntos
Potenciais de Ação , Mapeamento Potencial de Superfície Corporal , Morte Súbita Cardíaca/etiologia , Teste de Esforço , Exercício Físico , Sistema de Condução Cardíaco/fisiopatologia , Estresse Fisiológico , Fibrilação Ventricular/diagnóstico , Adulto , Idoso , Morte Súbita Cardíaca/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
6.
J Cardiovasc Electrophysiol ; 28(11): 1285-1294, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28776822

RESUMO

BACKGROUND: Ripple mapping (RM) displays electrograms as moving bars over a three-dimensional surface displaying bipolar voltage, and has shown in a single-center series to be effective for atrial tachycardia (AT) mapping without annotation of local activation time or window-of-interest assignment. We tested the reproducibility of these findings in operators naïve to RM, using it for the first time in postablation AT. METHODS: Maps were collected with multielectrode catheters and CARTO ConfiDENSE. A diagnosis of the tachycardia mechanism was made using RM and an assessment of operator confidence was made according to a three-grade scale (1 highest-3 lowest). RESULTS: The first 20 patients (64 ± 9 years, median two previous ablations) undergoing RM-guided AT ablation across five sites were studied. High-density maps (2,935 ± 1,328 points) in AT (CL = 296 ± 95 milliseconds) were collected. Macroreentrant ATs bordered by scar or anatomical obstacles were identified in n = 12 (60%), small reentrant ATs around scar in n = 3 (15%), and focal ATs from scar in n = 5 (25%). Diagnostic confidence with RM was grade 1 in n = 13 (65%), where operators felt confident to proceed to ablation without entrainment. Ablation offered the correct diagnosis n = 18 (90%). Retrospective review of the accompanying LAT maps demonstrated potential sources for error related to the window of interest selection, interpolation, and differentiating regions of scar during tachycardia on the voltage map. CONCLUSION: RM was easy to adopt by operators using it for the first time, and identified the correct target for ablation with high diagnostic confidence in most cases of complex AT.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento Tridimensional/métodos , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia
7.
J Cardiovasc Electrophysiol ; 28(12): 1445-1453, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28833757

RESUMO

INTRODUCTION: We hypothesized that very high-density mapping of typical atrial flutter (AFL) would facilitate a more complete understanding of its circuit. Such very high-density mapping was performed with the RhythmiaTM (Boston Scientific) mapping system using its 64 electrode basket catheter. METHODS AND RESULTS: Data were acquired from 13 patients in AFL. Functional anatomy of the right atrium (RA) was readily identified during mapping including the Crista Terminalis and Eustachian ridge. The leading edge of the activation wavefront was identified without interruption and its conduction velocity (CV) was calculated. CV was not different at the cavotricuspid isthmus (CTI) compared to the remainder of the RA (1.02 vs. 1.03 m/s, P = 0.93). The sawtooth pattern of the surface electrocardiogram (EKG) flutter waves was compared to the position of the dominant wavefront. The downslope of the surface EKG flutter waves represented on average 73% ± 9% of the total flutter cycle length. During the downslope, the activation wavefront traveled significantly further than during the upslope (182 ± 21 milliseconds vs. 68 ± 29 milliseconds, P < 0.0001) with no change in CV between the two phases (0.88 vs. 0.91 m/s, P = 0.79). CONCLUSION: CV at the CTI is not slower than other RA regions during typical AFL. The gradual downslope of the sawtooth EKG  is not due to slow conduction at the CTI suggesting that success of ablation at this site relates to anatomical properties rather than the presence of a "slow isthmus."


Assuntos
Flutter Atrial/fisiopatologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Valva Tricúspide/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
8.
Eur Heart J Digit Health ; 5(1): 50-59, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38264702

RESUMO

Aims: Implantable cardioverter defibrillator (ICD) therapies have been associated with increased mortality and should be minimized when safe to do so. We hypothesized that machine learning-derived ventricular tachycardia (VT) cycle length (CL) variability metrics could be used to discriminate between sustained and spontaneously terminating VT. Methods and results: In this single-centre retrospective study, we analysed data from 69 VT episodes stored on ICDs from 27 patients (36 spontaneously terminating VT, 33 sustained VT). Several VT CL parameters including heart rate variability metrics were calculated. Additionally, a first order auto-regression model was fitted using the first 10 CLs. Using features derived from the first 10 CLs, a random forest classifier was used to predict VT termination. Sustained VT episodes had more stable CLs. Using data from the first 10 CLs only, there was greater CL variability in the spontaneously terminating episodes (mean of standard deviation of first 10 CLs: 20.1 ± 8.9 vs. 11.5 ± 7.8 ms, P < 0.0001). The auto-regression coefficient was significantly greater in spontaneously terminating episodes (mean auto-regression coefficient 0.39 ± 0.32 vs. 0.14 ± 0.39, P < 0.005). A random forest classifier with six features yielded an accuracy of 0.77 (95% confidence interval 0.67 to 0.87) for prediction of VT termination. Conclusion: Ventricular tachycardia CL variability and instability are associated with spontaneously terminating VT and can be used to predict spontaneous VT termination. Given the harmful effects of unnecessary ICD shocks, this machine learning model could be incorporated into ICD algorithms to defer therapies for episodes of VT that are likely to self-terminate.

9.
Artigo em Inglês | MEDLINE | ID: mdl-36867371

RESUMO

BACKGROUND: Ablation of autonomic ectopy-triggering ganglionated plexuses (ET-GP) has been used to treat paroxysmal atrial fibrillation (AF). It is not known if ET-GP localisation is reproducible between different stimulators or whether ET-GP can be mapped and ablated in persistent AF. We tested the reproducibility of the left atrial ET-GP location using different high-frequency high-output stimulators in AF. In addition, we tested the feasibility of identifying ET-GP locations in persistent atrial fibrillation. METHODS: Nine patients undergoing clinically-indicated paroxysmal AF ablation received pacing-synchronised high-frequency stimulation (HFS), delivered in SR during the left atrial refractory period, to compare ET-GP localisation between a custom-built current-controlled stimulator (Tau20) and a voltage-controlled stimulator (Grass S88, SIU5). Two patients with persistent AF underwent cardioversion, left atrial ET-GP mapping with the Tau20 and ablation (Precision™, Tacticath™ [n = 1] or Carto™, SmartTouch™ [n = 1]). Pulmonary vein isolation (PVI) was not performed. Efficacy of ablation at ET-GP sites alone without PVI was assessed at 1 year. RESULTS: The mean output to identify ET-GP was 34 mA (n = 5). Reproducibility of response to synchronised HFS was 100% (Tau20 vs Grass S88; [n = 16] [kappa = 1, SE = 0.00, 95% CI 1 to 1)][Tau20 v Tau20; [n = 13] [kappa = 1, SE = 0, 95% CI 1 to 1]). Two patients with persistent AF had 10 and 7 ET-GP sites identified requiring 6 and 3 min of radiofrequency ablation respectively to abolish ET-GP response. Both patients were free from AF for > 365 days without anti-arrhythmics. CONCLUSIONS: ET-GP sites are identified at the same location by different stimulators. ET-GP ablation alone was able to prevent AF recurrence in persistent AF, and further studies would be warranted.

10.
J Am Heart Assoc ; 12(8): e028661, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37042261

RESUMO

Background Idiopathic ventricular fibrillation (VF) is a diagnosis of exclusion following normal cardiac investigations. We sought to determine if exercise-induced changes in electrical substrate could distinguish patient groups with various ventricular arrhythmic pathophysiological conditions and identify patients susceptible to VF. Methods and Results Computed tomography and exercise testing in patients wearing a 252-electrode vest were combined to determine ventricular conduction stability between rest and peak exercise, as previously described. Using ventricular conduction stability, conduction heterogeneity in idiopathic VF survivors (n=14) was compared with those surviving VF during acute ischemia with preserved ventricular function following full revascularization (n=10), patients with benign ventricular ectopy (n=11), and patients with normal hearts, no arrhythmic history, and negative Ajmaline challenge during Brugada family screening (Brugada syndrome relatives; n=11). Activation patterns in normal subjects (Brugada syndrome relatives) are preserved following exercise, with mean ventricular conduction stability of 99.2±0.9%. Increased heterogeneity of activation occurred in the idiopathic VF survivors (ventricular conduction stability: 96.9±2.3%) compared with the other groups combined (versus 98.8±1.6%; P=0.001). All groups demonstrated periodic variation in activation heterogeneity (frequency, 0.3-1 Hz), but magnitude was greater in idiopathic VF survivors than Brugada syndrome relatives or patients with ventricular ectopy (7.6±4.1%, 2.9±2.9%, and 2.8±1.2%, respectively). The cause of this periodicity is unknown and was not replicable by introducing exercise-induced noise at comparable frequencies. Conclusions In normal subjects, ventricular activation patterns change little with exercise. In contrast, patients with susceptibility to VF experience activation heterogeneity following exercise that requires further investigation as a testable manifestation of underlying myocardial abnormalities otherwise silent during routine testing.


Assuntos
Síndrome de Brugada , Complexos Ventriculares Prematuros , Humanos , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Sistema de Condução Cardíaco , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/complicações , Eletrocardiografia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Sobreviventes
11.
Cardiovasc Digit Health J ; 4(2): 60-67, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37101944

RESUMO

Background: Accurately determining arrhythmia mechanism from a 12-lead electrocardiogram (ECG) of supraventricular tachycardia can be challenging. We hypothesized a convolutional neural network (CNN) can be trained to classify atrioventricular re-entrant tachycardia (AVRT) vs atrioventricular nodal re-entrant tachycardia (AVNRT) from the 12-lead ECG, when using findings from the invasive electrophysiology (EP) study as the gold standard. Methods: We trained a CNN on data from 124 patients undergoing EP studies with a final diagnosis of AVRT or AVNRT. A total of 4962 5-second 12-lead ECG segments were used for training. Each case was labeled AVRT or AVNRT based on the findings of the EP study. The model performance was evaluated against a hold-out test set of 31 patients and compared to an existing manual algorithm. Results: The model had an accuracy of 77.4% in distinguishing between AVRT and AVNRT. The area under the receiver operating characteristic curve was 0.80. In comparison, the existing manual algorithm achieved an accuracy of 67.7% on the same test set. Saliency mapping demonstrated the network used the expected sections of the ECGs for diagnoses; these were the QRS complexes that may contain retrograde P waves. Conclusion: We describe the first neural network trained to differentiate AVRT from AVNRT. Accurate diagnosis of arrhythmia mechanism from a 12-lead ECG could aid preprocedural counseling, consent, and procedure planning. The current accuracy from our neural network is modest but may be improved with a larger training dataset.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38124803

RESUMO

Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41-0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67-1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.

13.
Cardiovasc Eng Technol ; 13(2): 219-233, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34453278

RESUMO

PURPOSE: Left atrial (LA) rapid AF activity has been shown to co-localise with areas of successful atrial fibrillation termination by catheter ablation. We describe a technique that identifies rapid and regular activity. METHODS: Eight-second AF electrograms were recorded from LA regions during ablation for psAF. Local activation was annotated manually on bipolar signals and where these were of poor quality, we inspected unipolar signals. Dominant cycle length (DCL) was calculated from annotation pairs representing a single activation interval, using a probability density function (PDF) with kernel density estimation. Cumulative annotation duration compared to total segment length defined electrogram quality. DCL results were compared to dominant frequency (DF) and averaging. RESULTS: In total 507 8 s AF segments were analysed from 7 patients. Spearman's correlation coefficient was 0.758 between independent annotators (P < 0.001), 0.837-0.94 between 8 s and ≥ 4 s segments (P < 0.001), 0.541 between DCL and DF (P < 0.001), and 0.79 between DCL and averaging (P < 0.001). Poorer segment organization gave greater errors between DCL and DF. CONCLUSION: DCL identifies rapid atrial activity that may represent psAF drivers. This study uses DCL as a tool to evaluate the dynamic, patient specific properties of psAF by identifying rapid and regular activity. If automated, this technique could rapidly identify areas for ablation in psAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Análise Espacial
14.
Eur Heart J Digit Health ; 3(3): 405-414, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36712163

RESUMO

Aims: Accurately determining atrial arrhythmia mechanisms from a 12-lead electrocardiogram (ECG) can be challenging. Given the high success rate of cavotricuspid isthmus (CTI) ablation, identification of CTI-dependent typical atrial flutter (AFL) is important for treatment decisions and procedure planning. We sought to train a convolutional neural network (CNN) to classify CTI-dependent AFL vs. non-CTI dependent atrial tachycardia (AT), using data from the invasive electrophysiology (EP) study as the gold standard. Methods and results: We trained a CNN on data from 231 patients undergoing EP studies for atrial tachyarrhythmia. A total of 13 500 five-second 12-lead ECG segments were used for training. Each case was labelled CTI-dependent AFL or non-CTI-dependent AT based on the findings of the EP study. The model performance was evaluated against a test set of 57 patients. A survey of electrophysiologists in Europe was undertaken on the same 57 ECGs. The model had an accuracy of 86% (95% CI 0.77-0.95) compared to median expert electrophysiologist accuracy of 79% (range 70-84%). In the two thirds of test set cases (38/57) where both the model and electrophysiologist consensus were in agreement, the prediction accuracy was 100%. Saliency mapping demonstrated atrial activation was the most important segment of the ECG for determining model output. Conclusion: We describe the first CNN trained to differentiate CTI-dependent AFL from other AT using the ECG. Our model matched and complemented expert electrophysiologist performance. Automated artificial intelligence-enhanced ECG analysis could help guide treatment decisions and plan ablation procedures for patients with organized atrial arrhythmias.

15.
Heart Rhythm ; 19(4): 516-524, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34915187

RESUMO

BACKGROUND: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system may play a role in atrial fibrillation (AF). OBJECTIVE: We hypothesized that ablating the ectopy-triggering GPs (ET-GPs) prevents AF. METHODS: GANGLIA-AF (ClinicalTrials.gov identifier NCT02487654) was a prospective, randomized, controlled, 3-center trial. ET-GPs were mapped using high frequency stimulation, delivered within the atrial refractory period and ablated until nonfunctional. If triggered AF became incessant, atrioventricular dissociating GPs were ablated. We compared GP ablation (GPA) without pulmonary vein isolation (PVI) against PVI in patients with paroxysmal AF. Follow-up was for 12 months including 3-monthly 48-hour Holter monitors. The primary end point was documented ≥30 seconds of atrial arrhythmia after a 3-month blanking period. RESULTS: A total of 102 randomized patients were analyzed on a per-protocol basis after GPA (n = 52; 51%) or PVI (n = 50; 49%). Patients who underwent GPA had 89 ± 26 high frequency stimulation sites tested, identifying a median of 18.5% (interquartile range 16%-21%) of GPs. The radiofrequency ablation time was 22.9 ± 9.8 minutes in GPA and 38 ± 14.4 minutes in PVI (P < .0001). The freedom from ≥30 seconds of atrial arrhythmia at 12-month follow-up was 50% (26 of 52) with GPA vs 64% (32 of 50) with PVI (log-rank, P = .09). ET-GPA without atrioventricular dissociating GPA achieved 58% (22 of 38) freedom from the primary end point. There was a significantly higher reduction in antiarrhythmic drug usage postablation after GPA than after PVI (55.5% vs 36%; P = .05). Patients were referred for redo ablation procedures in 31% (16 of 52) after GPA and 24% (12 of 50) after PVI (P = .53). CONCLUSION: GPA did not prevent atrial arrhythmias more than PVI. However, less radiofrequency ablation was delivered to achieve a higher reduction in antiarrhythmic drug usage with GPA than with PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Gânglios/cirurgia , Átrios do Coração , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Heart Rhythm ; 18(10): 1682-1690, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34004345

RESUMO

BACKGROUND: Conduction channels have been demonstrated within the postinfarct scar and seem to be co-located with the isthmus of ventricular tachycardia (VT). Mapping the local scar potentials (SPs) that define the conduction channels is often hindered by large far-field electrograms generated by healthy myocardium. OBJECTIVE: The purpose of this study was to map conduction channel using ripple mapping to categorize SPs temporally and anatomically. We tested the hypothesis that ablation of early SPs would eliminate the latest SPs without direct ablation. METHODS: Ripple maps of postinfarct scar were collected using the PentaRay (Biosense Webster) during normal rhythm. Maps were reviewed in reverse, and clusters of SPs were color-coded on the geometry, by timing, into early, intermediate, late, and terminal. Ablation was delivered sequentially from clusters of early SPs, checking for loss of terminal SPs as the endpoint. RESULTS: The protocol was performed in 11 patients. Mean mapping time was 65 ± 23 minutes, and a mean 3050 ± 1839 points was collected. SP timing ranged from 98.1 ± 60.5 ms to 214.8 ± 89.8 ms post QRS peak. Earliest SPs were present at the border, occupying 16.4% of scar, whereas latest SPs occupied 4.8% at the opposing border or core. Analysis took 15 ± 10 minutes to locate channels and identify ablation targets. It was possible to eliminate latest SPs in all patients without direct ablation (mean ablation time 16.3 ± 11.1 minutes). No VT recurrence was recorded (mean follow-up 10.1 ± 7.4 months). CONCLUSION: Conduction channels can be located using ripple mapping to analyze SPs. Ablation at channel entrances can eliminate the latest SPs and is associated with good medium-term results.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Infarto do Miocárdio/complicações , Miocárdio/patologia , Taquicardia Ventricular/etiologia , Idoso , Cicatriz/complicações , Cicatriz/diagnóstico , Cicatriz/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
17.
Am J Cardiol ; 160: 53-59, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34610873

RESUMO

A multivariate risk score model was proposed by Sieira et al in 2017 for sudden death in Brugada syndrome; their validation in 150 patients was highly encouraging, with a C-index of 0.81; however, this score is yet to be validated by an independent group. A total of 192 records of patients with Brugada syndrome were collected from 2 centers in the United Kingdom and retrospectively scored according to a score model by Sieira et al. Data were compiled summatively over follow-up to mimic regular risk re-evaluation as per current guidelines. Sudden cardiac death survivor data were considered perievent to ascertain the utility of the score before cardiac arrest. Scores were compared with actual outcomes. Sensitivity in our cohort was 22.7%, specificity was 57.6%, and C-index was 0.58. In conclusion, up to 75% of cardiac arrest survivors in this cohort would not have been offered a defibrillator if evaluated before their event. This casts doubt on the utility of the score model for primary prevention of sudden death. Inherent issues with modern risk scoring strategies decrease the likelihood of success even in robustly designed tools such as the Sieira score model.


Assuntos
Síndrome de Brugada/terapia , Morte Súbita Cardíaca/epidemiologia , Síndrome de Brugada/complicações , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco , Síndrome do Nó Sinusal/fisiopatologia , Síncope/fisiopatologia , Reino Unido/epidemiologia
19.
PLoS One ; 16(4): e0249201, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33819279

RESUMO

INTRODUCTION: During viral pandemics, filtering facepiece (FFP) masks together with eye protection form the essential components of personal protective equipment (PPE) for healthcare workers. There remain concerns regarding insufficient global supply and imperfect protection offered by currently available PPE strategies. A range of full-face snorkel masks were adapted to accept high grade medical respiratory filters using bespoke-designed 3D-printed connectors. We compared the protection offered by the snorkel to that of standard PPE using a placebo-controlled respirator filtering test as well as a fluorescent droplet deposition experiment. Out of the 56 subjects tested, 42 (75%) passed filtering testing with the snorkel mask compared to 31 (55%) with a FFP3 respirator mask (p = 0.003). Amongst the 43 subjects who were not excluded following a placebo control, 85% passed filtering testing with the snorkel versus to 68% with a FFP3 mask (p = 0.008). Following front and lateral spray of fluorescence liquid particles, the snorkel mask also provided superior protection against droplet deposition within the subject's face, when compared to a standard PPE combination of FFP3 masks and eye protection (3.19x108 versus 6.81x108 fluorescence units, p<0.001). The 3D printable adaptors are available for free download online at https://www.ImperialHackspace.com/COVID-19-Snorkel-Respirator-Project/. CONCLUSION: Full-face snorkel masks adapted as particulate respirators performed better than a standard PPE combination of FFP3 mask and eye protection against aerosol inhalation and droplet deposition. This adaptation is therefore a promising PPE solution for healthcare workers during highly contagious viral outbreaks.


Assuntos
COVID-19/prevenção & controle , Pessoal de Saúde , Máscaras , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Adulto , Feminino , Humanos , Masculino
20.
Auton Neurosci ; 228: 102699, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32769021

RESUMO

BACKGROUND: Epicardial ganglionated plexuses (GP) have an important role in the pathogenesis of atrial fibrillation (AF). The relationship between anatomical, histological and functional effects of GP is not well known. We previously described atrioventricular (AV) dissociating GP (AVD-GP) locations. In this study, we hypothesised that ectopy triggering GP (ET-GP) are upstream triggers of atrial ectopy/AF and have different anatomical distribution to AVD-GP. OBJECTIVES: We mapped and characterised ET-GP to understand their neural mechanism in AF and anatomical distribution in the left atrium (LA). METHODS: 26 patients with paroxysmal AF were recruited. All were paced in the LA with an ablation catheter. High frequency stimulation (HFS) was synchronised to each paced stimulus for delivery within the local atrial refractory period. HFS responses were tagged onto CARTO™ 3D LA geometry. All geometries were transformed onto one reference LA shell. A probability distribution atlas of ET-GP was created. This identified high/low ET-GP probability regions. RESULTS: 2302 sites were tested with HFS, identifying 579 (25%) ET-GP. 464 ET-GP were characterised, where 74 (16%) triggered ≥30s AF/AT. Median 97 (IQR 55) sites were tested, identifying 19 (20%) ET-GP per patient. >30% of ET-GP were in the roof, mid-anterior wall, around all PV ostia except in the right inferior PV (RIPV) in the posterior wall. CONCLUSION: ET-GP can be identified by endocardial stimulation and their anatomical distribution, in contrast to AVD-GP, would be more likely to be affected by wide antral circumferential ablation. This may contribute to AF ablation outcomes.


Assuntos
Fibrilação Atrial/fisiopatologia , Complexos Atriais Prematuros/fisiopatologia , Ablação por Cateter , Gânglios Autônomos/fisiologia , Coração/inervação , Pericárdio/inervação , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Complexos Atriais Prematuros/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa