Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Echocardiography ; 37(6): 808-814, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32524654

RESUMO

BACKGROUND: Studies determining the reliability of the World Heart Federation (WHF) anterior mitral valve leaflet (AMVL) measurement are limited by the introduction of bias in their test-retest analyses. This study sought to determine the reliability of the current AMVL measurement while controlling for systematic bias. METHODS: Retrospective analysis of echocardiographic data from 16 patients with previous acute rheumatic fever was performed. Included in this study was an optimized cine loop of the mitral valve (MV) [reader-optimized measurement (ROM]) in the parasternal long-axis view and an optimized still image of the MV obtained from the same cine loop [specialist-optimized image (SOI)]. Each still image and associated cine loop was quadruplicated and randomized to determine intra- and inter-rater agreement and quantify the impact of zoom on AMVL measurement. RESULTS: Specialist-optimized image without zoom reflected the highest degree of agreement in both cohorts with an ICC of 0.29 and 0.46. The agreement in ROM images without zoom was ICC of 0.23 and 0.45. The addition of zoom to SOI decreased agreement further to an ICC of 0.20 and 0.36. The setting associated with the poorest agreement profile was ROI with zoom with an ICC of 0.13 and 0.34, respectively. The intra-rater agreement between readers in both cohorts was moderate across all settings with an ICC ranging between 0.64 and 0.86. CONCLUSIONS: The WHF AMVL measurement is only moderately repeatable within readers and demonstrates poor reproducibility that was not improved by the addition of a zoom-optimized protocol. Given our study findings, we cannot advocate the current WHF AMVL measurement as a reliable assessment for RHD.


Assuntos
Insuficiência da Valva Mitral , Cardiopatia Reumática , Humanos , Valva Mitral/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Cardiopatia Reumática/diagnóstico por imagem
2.
Echocardiography ; 30(5): 527-33, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23316786

RESUMO

BACKGROUND: Resting echocardiographic measures of cardiac function such as left ventricular ejection fraction correlate poorly with exercise capacity. Assessment during exercise using measures less dependent on hemodynamic loading conditions, such as tissue Doppler imaging (TDI), may more accurately characterize the relationship between cardiac function and exercise capacity. METHODS AND RESULTS: One hundred one subjects with various cardiac diagnoses underwent exercise stress echocardiography with simultaneous cardiopulmonary gas exchange analysis. Standard two-dimensional, Doppler and spectral TDI parameters were assessed at both rest and peak exercise. Across all subjects the strongest relationship with peak oxygen uptake (pVO2 ) was with peak left ventricular systolic tissue velocity (S') during exercise (r = 0.84, P < 0.001). The strength of the relationship was greater than that observed with any other common echocardiographic measure of systolic or diastolic cardiac function. CONCLUSION: There is a very strong relationship between measurements of S' during exercise and exercise capacity. The previously observed poor correlation with standard measures of systolic and diastolic cardiac function may be explained both by the load dependence of parameters such as ejection fraction and by reliance on resting as opposed to exercise assessment.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia sob Estresse , Tolerância ao Exercício/fisiologia , Contração Miocárdica/fisiologia , Volume Sistólico/fisiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/fisiopatologia , Estudos de Casos e Controles , Estudos de Coortes , Teste de Esforço/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Testes de Função Cardíaca , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Consumo de Oxigênio/fisiologia , Fisiologia , Valor Preditivo dos Testes , Valores de Referência , Medição de Risco , Índice de Gravidade de Doença , Função Ventricular Esquerda/fisiologia
3.
Europace ; 13(6): 815-20, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21208945

RESUMO

AIMS: In patients requiring permanent pacemaker implantation for sinus node disease (SND) or atrioventricular (AV) block, right ventricular (RV) pacing has been demonstrated to increase the risk of developing atrial fibrillation (AF). The effects of RV pacing in patients with paroxysmal AF are less well defined. Short- and medium-term studies have suggested no significant correlation between RV pacing and atrial fibrillation burden (AFB) measurement; we sought to assess for an effect in the long-term. METHODS AND RESULTS: Sixty-six patients were randomized to receive either conventional dual chamber pacing (DDDR, n = 33), or dual chamber minimal ventricular pacing (MinVP, n = 33), for a period of at least 1 year. Patients were reviewed every 6 months and all pacemaker data were downloaded. The primary outcome measures were device-derived AFB and progression to persistent AF. The mean duration of study follow-up was 1.4 ± 0.6 years. Mean ventricular pacing was less in the MinVP cohort compared with the DDDR cohort (5.8 vs. 74.0%, P < 0.001). At follow-up, the device-derived AFB was significantly lower in the MinVP cohort when compared with the DDDR cohort (12.8 ± 15.3% vs. DDDR 47.6 ± 42.2%, P < 0.001). Kaplan-Meier estimates of time to onset of persistent AF showed significant reductions in the rates of persistent AF for MinVP pacing (9%) when compared with conventional DDDR pacing (42%), P = 0.004. CONCLUSION: Right ventricular pacing induces increased AFB in patients with paroxysmal AF in the long term. Dual chamber MinVP algorithms result in reduced AFB and reduced disease progression from paroxysmal to persistent AF in the long term.


Assuntos
Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Progressão da Doença , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Bloqueio Atrioventricular/terapia , Feminino , Seguimentos , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Síndrome do Nó Sinusal/terapia , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento
4.
Eur Heart J Open ; 1(3): oeab041, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35919886

RESUMO

Aims: The World Heart Federation (WHF) criteria identify a large borderline rheumatic heart disease (RHD) category that has hampered the implementation of population-based screening. Inter-scallop separations (ISS) of the posterior mitral valve leaflet, a recently described normal variant of the mitral valve, appears to be an important cause of mild mitral regurgitation (MR) leading to misclassification of cases as WHF 'borderline RHD'. This study aims to report the findings of the Echo in Africa project, a large-scale RHD screening project in South Africa and determine what proportion of borderline cases would be re-classified as normal if there were a systematic identification of ISS-related MR. Methods and results: A prospective cross-sectional study of underserved secondary schools in the Western Cape was conducted. Participants underwent a screening study with a handheld (HH) ultrasound device. Children with an abnormal HH study were re-evaluated with a portable laptop echocardiography machine. A mechanistic evaluation was applied in cases with isolated WHF 'pathological' MR (WHF 'borderline RHD'). A total of 5255 participants (mean age 15± years) were screened. A total of 3439 (65.8%) were female. Forty-nine cases of WHF 'definite RHD' [9.1 cases/1000 (95% confidence interval, CI, 6.8-12.1 cases/1000)] and 104 cases of WHF 'borderline RHD' [19.5 cases/1000 (95% CI, 16.0-23.7 cases/1000)] were identified. Inter-scallop separations-related MR was the underlying mechanism of MR in 48/68 cases classified as WHF 'borderline RHD' with isolated WHF 'pathological' MR (70.5%). Conclusion: In a real-world, large-scale screening project, the adoption of a mechanistic evaluation based on the systematic identification of ISS-related MR markedly reduced the number of WHF 'screen-positive' cases misclassified as WHF 'borderline RHD'. Implementing strategies that reduce this misclassification could reduce the cost- and labour burden on large-scale RHD screening programmes.

5.
Pacing Clin Electrophysiol ; 33(1): 85-93, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19889192

RESUMO

INTRODUCTION: Accurate atrial arrhythmia discrimination is important for dual chamber pacemakers and defibrillators. The aim was to assess the accuracy of atrial arrhythmia recording using modern devices and relate this to atrial tip-to-ring (TTR) distance. METHODS: One hundred eighty-two patients (72 + or - 9 years, 55% male) with paroxysmal atrial fibrillation were enrolled and were included in the study if they had an atrial fibrillation (AF) burden of 1-50% during a monitoring phase. Seventy-nine patients fulfilled these criteria and were followed for at least 5 months. Electrodes were classified as having short (<10 mm), medium (10-12), or long (13-18) atrial TTR spacing. RESULTS: Two thousand eight hundred eighty-three detailed onset reports were analyzed; 730 (25%) demonstrated aberrant sensing. Six percent were due to farfield R wave oversensing (FFRWO) and 19% due to undersensing, sometimes occurring in the same patient and study phase. FFRWO was significantly reduced with short TTR electrodes (P < 0.05). Undersensing due to sensitivity fallout was 18% (short), 24% (medium), and 17% (long) (P = ns). Undersensing due to pacemaker blanking was 11% (short), 11% (medium), and 12% (long) (P = ns). Active fixation electrodes did not show any difference from passive fixation. CONCLUSION: Atrial electrodes with a short TTR (<10 mm) significantly reduce FFRWO without increasing undersensing and should be used routinely in patients with paroxysmal atrial tachyarrhythmias. However, 20% of atrial tachyarrythmia episodes were incorrectly classified as terminated by these modern devices due to undersensing. Clinicians should be wary of using device-derived endpoints that rely on AF episode number or duration as these may be falsely increased or reduced, respectively.


Assuntos
Eletrodos , Marca-Passo Artificial , Taquicardia/diagnóstico , Idoso , Fibrilação Atrial/diagnóstico , Desenho de Equipamento , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
6.
Echo Res Pract ; 6(3): 43-52, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31100718

RESUMO

BACKGROUND: Mortality dramatically rises with the onset of symptoms in patients with severe aortic stenosis (AS). Surgery is indicated when symptoms become apparent or when there is ventricular decompensation. Cardiopulmonary exercise testing (CPET) in combination with exercise echocardiography can unmask symptoms and provides valuable information regarding contractile reserve. The aim of the present study was to determine the prevalence of reduced exercise tolerance and the parameters predicting adverse cardiovascular events. METHODS: Thirty-two patients with asymptomatic severe AS were included in this study. Patients were followed up as part of an enhanced surveillance clinic. RESULTS: Age was 69 ± 15.7 years, 75% of patients were male. Patients had a raised NT-ProBNP of 301 pg/mL. VO2peak was 19.5 ± 6.2 mL/kg/min. Forty-one percent of patients had a reduced %VO2peak and this predicted unplanned cardiac hospitalisation (P = 0.005). Exercise systolic longitudinal velocity (S') and age were the strongest independent predictors for VO2peak (R 2 = 0.76; P < 0.0001). Exercise S' was the strongest independent predictor for NT-ProBNP (R 2 = 0.48; P = 0.001). CONCLUSION: A large proportion of patients had a lower than predicted VO2peak. The major determinant of exercise and NT-ProBNP is the ability of the left ventricle (LV) to augment S' on exercise rather than the severity of aortic valve obstruction or resting structural remodelling of the LV. Reduced exercise tolerance and more adverse remodelling, rather than valve obstruction predicted unplanned hospitalisation. This study demonstrates that for those patients, in whom a watchful waiting is an agreed strategy, a detailed assessment should be undertaken including CPET, exercise echocardiography and biomarkers to ensure those with exercise limitation and risk of decompensation are detected early and treated appropriately.

7.
Eur J Echocardiogr ; 9(1): 136-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17905663

RESUMO

A 75-year-old woman presented with left ventricular apical ballooning syndrome mimicking acute anterior myocardial infarction. She had a long history of chest tightness and was undergoing a contrast stress echocardiogram because of frequent re-admissions with chest pain, all with normal ECGs and troponins. A standard dobutamine/atropine protocol had been used. The patient developed central crushing chest pain, marked ST elevation, transient slowing of heart rate and left ventricular apical ballooning. She was admitted to the coronary care unit and received thrombolysis. Echocardiography showed no mitral regurgitation, normal pulmonary artery systolic pressure and no intraventricular gradient. Immediate troponin T was significantly raised and peaked at 6 h. The patient underwent coronary angiography the next day. This showed systolic left ventricular apical ballooning and no coronary lesions or vasospasm. A further contrast echo 2 weeks later showed complete resolution of the wall motion abnormalities. Left ventricular apical ballooning or takotsubo syndrome can lead to cardiogenic shock but has a favourable prognosis compared to myocardial infarction. This patient was noted to be unusually anxious about having a stress echocardiogram and mental stress might be a precipitating factor, furthermore, this response during dobutamine stress echocardiography favours a catecholamine related disease mechanism.


Assuntos
Ecocardiografia sob Estresse/efeitos adversos , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Idoso , Feminino , Humanos , Cardiomiopatia de Takotsubo/etiologia
8.
J Bone Joint Surg Am ; 99(21): 1827-1835, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29088037

RESUMO

BACKGROUND: High failure rates of metal-on-metal (MoM) hip implants prompted regulatory authorities to issue worldwide safety alerts. Circulating cobalt from these implants causes rare but fatal autopsy-diagnosed cardiotoxicity. There is concern that milder cardiotoxicity may be common and underrecognized. Although blood metal ion levels are easily measured and can be used to track local toxicity, there are no noninvasive tests for organ deposition. We sought to detect correlation between blood metal ions and a comprehensive panel of established markers of early cardiotoxicity. METHODS: Ninety patients were recruited into this prospective single-center blinded study. Patients were divided into 3 age and sex-matched groups according to implant type and whole-blood metal ion levels. Group-A patients had a ceramic-on-ceramic [CoC] bearing; Group B, an MoM bearing and low blood metal ion levels; and Group C, an MoM bearing and high blood metal-ion levels. All patients underwent detailed cardiovascular phenotyping using cardiac magnetic resonance imaging (CMR) with T2*, T1, and extracellular volume mapping; echocardiography; and cardiac blood biomarker sampling. T2* is a novel CMR biomarker of tissue metal loading. RESULTS: Blood cobalt levels differed significantly among groups A, B, and C (mean and standard deviation [SD], 0.17 ± 0.08, 2.47 ± 1.81, and 30.0 ± 29.1 ppb, respectively) and between group A and groups B and C combined. No significant between-group differences were found in the left atrial or ventricle size, ejection fraction (on CMR or echocardiography), T1 or T2* values, extracellular volume, B-type natriuretic peptide level, or troponin level, and all values were within normal ranges. There was no relationship between cobalt levels and ejection fraction (R = 0.022, 95% confidence interval [CI] = -0.185 to 0.229) or T2* values (R = 0.108, 95% CI = -0.105 to 0.312). CONCLUSIONS: Using the best available technologies, we did not find that high (but not extreme) blood cobalt and chromium levels had any significant cardiotoxic effect on patients with an MoM hip implant. There were negligible-to-weak correlations between elevated blood metal ion levels and ejection fraction even at the extremes of the 95% CI, which excludes any clinically important association. LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/efeitos adversos , Técnicas de Imagem Cardíaca/métodos , Cardiotoxicidade/diagnóstico por imagem , Cardiotoxicidade/etiologia , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Cobalto/efeitos adversos , Cobalto/sangue , Estudos Transversais , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Ferro/análise , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Prospectivos , Fatores de Risco
9.
Echo Res Pract ; 2(1): 19-27, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26693312

RESUMO

Resting echocardiography measurements are poor predictors of exercise capacity and symptoms in patients with heart failure (HF). Stress echocardiography may provide additional information and can be expressed using left ventricular ejection fraction (LVEF), or diastolic parameters (E/E'), but LVEF has some major limitations. Systolic annular velocity (S') provides a measure of longitudinal systolic function, which is relatively easy to obtain and shows a good relationship with exercise capacity. The objective of this study was to investigate the relationship among S', E/E' and LVEF obtained during stress echocardiography and both mortality and hospitalisation. A secondary objective was to compare S' measured using a simplified two-wall model. A total of 80 patients with stable HF underwent exercise stress echocardiography and simultaneous cardiopulmonary exercise testing. Volumetric and tissue velocity imaging (TVI) measurements were obtained, as was peak oxygen uptake (VO2 peak). Of the total number of patients, 11 died and 22 required cardiac hospitalisation. S' at peak exertion was a powerful predictor for death and hospitalisation. Cut-off points of 5.3 cm/s for death and 5.7 cm/s for hospitalisation provided optimum sensitivity and specificity. This study suggests that, in patients with systolic HF, S' at peak exertion calculated from the averaged spectral TVI systolic velocity of six myocardial segments, or using a simplified measure of two myocardial segments, is a powerful predictor of future events and stronger than LVEF, diastolic velocities at rest or exercise and VO2 peak. Results indicate that measuring S' during exercise echocardiography might play an important role in understanding the likelihood of adverse clinical outcomes in patients with HF.

10.
J Interv Card Electrophysiol ; 28(1): 51-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20082131

RESUMO

INTRODUCTION: The beneficial effects of atrial pacing on the incidence, duration and symptomatology of paroxysmal atrial fibrillation (PAF) may be negated by increased ventricular pacing. This prospective randomised study evaluates the effect of pacing algorithms that minimise ventricular pacing (MinVP) with and without anti-AF algorithms, on AF burden (AFB) in patients with symptomatic PAF. METHODS: Patients implanted with pacemakers with MinVP capability with AFB 1-70% were enrolled. Three different DDDRP devices were assessed. Following a 1-month induction phase, patients were randomised to MinVP with and without preventive AF algorithms or dual chamber rate adaptive pacemaker (DDDR) (AV delay (AVD) 150 ms) for 2 months per study phase. The primary outcome measure was AFB. RESULTS: One hundred and ten patients were enrolled; of these, 66 (mean age 74.3 + or - 7.9, 56% males) had an AFB of 1-70% during the induction phase and completed all study phases. There was no significant difference in AFB between the control phase DDDR, 13.8% (95% CI 8.7 to 18.8), and MinVP, 14.4% (95% CI 9.4 to 19.4), or MinVP with AF algorithms enabled, 14.7% (95% CI 9.7 to 19.7), (p = 0.65 and p = 0.49, respectively). Median ventricular pacing was significantly higher during the control phase, 86.0% (IQR 72.8, 97.3), than in MinVP 2.0% (IQR 0.0, 14.1) and MinVP + algorithms 3.0% (IQR 0.4, 15.6), p = < 0.001. CONCLUSION: MinVP algorithms are effective in reducing ventricular pacing. However, there is no significant reduction in AFB with minimal ventricular pacing algorithms in the short term. No additional benefit or adverse outcome was found with preventative anti-AF algorithms in combination with MinVP algorithms.


Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Taquicardia Paroxística/terapia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/terapia , Intervalos de Confiança , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Taquicardia Paroxística/diagnóstico , Resultado do Tratamento
11.
Maturitas ; 63(1): 28-33, 2009 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-19321277

RESUMO

Cardiovascular diseases are the most common cause of death among women. Women historically under-appreciate these risks. There are key differences in terms of the relative importance of risk factors, particularly in the age of presentation. The female 'gender advantage' previously felt to be due to female sex hormones remains unexplained. The effects of post-menopausal hormone replacement also remain controversial. Risk can be reduced by sensible risk-factor control, but there is an ongoing imbalance between calculated risk and evidence of subclinical atherosclerosis and in women, in particular, a more proactive approach to risk reduction may be required. The controversy surrounding the effectiveness of statins in women is probably more due to problems with meta-analyses than from gender dimorphism. Cardiac rehabilitation reduces cardiac risk but women have previously been under-referred, although the benefits are equally great in both genders.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/etiologia , Doença das Coronárias/mortalidade , Dieta , Terapia de Reposição de Estrogênios , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Medição de Risco , Fatores de Risco , Fatores Sexuais
12.
J Interv Card Electrophysiol ; 26(1): 83-9, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19629664

RESUMO

PURPOSE: The study aim was to validate the closed loop stimulation (CLS) vs. accelerometer (ACC) rate-responsive sensors with electrodes placed in the right ventricular high septal (RVHS) or right ventricular apical (RVA) lead positions in patients following 'ablate and pace' therapy for persistent atrial fibrillation. METHODS: 'Ablate and pace' patients were randomised to either RVHS or RVA electrode placement with a dual sensor device. A double-blind crossover study comparing CLS vs. ACC rate-response pacing modes was undertaken. Subjects undertook cardiopulmonary testing with constant workload light exercise followed by a ramp protocol in addition to activity of daily living assessments. RESULTS: Twenty subjects (14 male; age, 74 +/- 8 years) were studied. Heart rate increase was greater from lying to sitting with ACC. With mental stress, heart rate increase was greater with CLS. Peak heart rates were similar for stair ascent and descent in ACC mode. With CLS mode, however, the peak heart rate was significantly lower for stair descent. There was no difference between modes in mean response time, oxygen deficit, peak VO(2), VO(2) at anaerobic threshold, peak heart rate, total exercise time and total workload. CLS function was equally optimal at both electrode sites. CONCLUSIONS: CLS rate adaptive pacing is appropriate for 'ablate and pace' patients, and this sensor functions equally well using RVA or RVHS lead positions.


Assuntos
Aceleração , Ablação por Cateter , Eletrodos Implantados , Septos Cardíacos/cirurgia , Marca-Passo Artificial , Transdutores , Idoso , Estimulação Cardíaca Artificial/métodos , Terapia Combinada , Estudos Cross-Over , Método Duplo-Cego , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Resultado do Tratamento
13.
J Am Soc Echocardiogr ; 21(7): 808-12, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18486444

RESUMO

OBJECTIVE: Exercise-induced changes in the synchrony of left ventricular contraction may be an important therapeutic target in heart failure. There are limited data to support the feasibility of exercise assessments. In addition, the effect of exercise on synchrony in healthy individuals is undetermined. METHODS: Eleven healthy young men underwent tissue Doppler assessments before and immediately after maximal cardiopulmonary exercise. Left ventricular synchrony was assessed using pulsed wave tissue Doppler of the lateral, septal, inferior, and anterior walls. The maximal dispersion times between the walls for onset and peak systolic velocities were used as synchrony indices. RESULTS: The proportion of the cardiac cycle taken between Q wave and time to onset or peak systolic motion was constant at rest and peak exercise. There was no significant exercise-induced change seen in either interventricular or intraventricular synchrony. CONCLUSION: Exercise synchrony assessment is technically feasible. Synchronization of cardiac contraction is maintained after maximal exercise in healthy individuals.


Assuntos
Ecocardiografia Doppler/métodos , Exercício Físico/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto , Eletrocardiografia , Teste de Esforço , Humanos , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Descanso/fisiologia , Função Ventricular
14.
Europace ; 9(9): 790-7, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17562750

RESUMO

AIMS: The PAFS study is a randomized, multicentre investigation of the effects of third generation anti-atrial fibrillation pacemaker algorithms in patients with paroxysmal atrial fibrillation (PAF). METHODS AND RESULTS: 182 patients (72 +/- 9 years, 55% male) with at least three symptomatic episodes of PAF within prior 3 months resistant to two anti-arrhythmics were enrolled. A pacemaker-derived atrial fibrillation (AF) burden of 1-50% was required in the initial induction phase. Seventy-nine patients fulfilled these criteria and were randomized to four, month-long phases in a crossover design. Algorithm phases were 'rate soothing' on, 'ventricular rate stabilization' on, and 'All on', which included these two algorithms plus post-AF response. The algorithm phases were compared to 'All off' dual chamber universal mode (DDD 60) for the analysis. Forty-two percent of patients enrolled in the monitoring phase had no AF. The percentage of AF induced by premature atrial contractions (PACs) was significantly reduced by rate soothing from 25 to 17% (P < 0.05). There was no significant change in AF burden, AF episode number, quality of life, or symptoms with any algorithm (P = ns). CONCLUSION: The rate-soothing algorithm by atrial overdrive pacing reduced PAC-initiated PAF. However, there was no overall change in AF burden, PAF episodes, patient symptoms, or quality of life. Forty-two percent of PAF patients did not show any AF after enrollment, suggesting that bradycardia pacing alone eliminates AF.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Átrios do Coração/patologia , Taquicardia Paroxística/prevenção & controle , Taquicardia Paroxística/terapia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Bradicardia , Estudos Cross-Over , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Taquicardia Paroxística/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa