Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Circ Res ; 108(7): 792-6, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21415390

RESUMO

RATIONALE: Transcatheter, intramyocardial injections of bone marrow-derived cell therapy produces reverse remodeling in large animal models of ischemic cardiomyopathy. OBJECTIVE: We used cardiac MRI (CMR) in patients with left ventricular (LV) dysfunction related to remote myocardial infarction (MI) to test the hypothesis that bone marrow progenitor cell injection causes functional recovery of scarred myocardium and reverse remodeling. METHODS AND RESULTS: Eight patients (aged 57.2±13.3 years) received transendocardial, intramyocardial injection of autologous bone marrow progenitor cells (mononuclear or mesenchymal stem cells) in LV scar and border zone. All patients tolerated the procedure with no serious adverse events. CMR at 1 year demonstrated a decrease in end diastolic volume (208.7±20.4 versus 167.4±7.32 mL; P=0.03), a trend toward decreased end systolic volume (142.4±16.5 versus 107.6±7.4 mL; P=0.06), decreased infarct size (P<0.05), and improved regional LV function by peak Eulerian circumferential strain in the treated infarct zone (-8.1±1.0 versus -11.4±1.3; P=0.04). Improvements in regional function were evident at 3 months, whereas the changes in chamber dimensions were not significant until 6 months. Improved regional function in the infarct zone strongly correlated with reduction of end diastolic volume (r(2)=0.69, P=0.04) and end systolic volume (r(2)=0.83, P=0.01). CONCLUSIONS: These data suggest that transcatheter, intramyocardial injections of autologous bone marrow progenitor cells improve regional contractility of a chronic myocardial scar, and these changes predict subsequent reverse remodeling. The findings support the potential clinical benefits of this new treatment strategy and ongoing randomized clinical trials.


Assuntos
Transplante de Células-Tronco Mesenquimais/métodos , Recuperação de Função Fisiológica/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/cirurgia , Remodelação Ventricular/fisiologia , Adulto , Idoso , Humanos , Injeções , Imageamento por Ressonância Magnética , Masculino , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Infarto do Miocárdio/complicações , Projetos Piloto , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
2.
Heart ; 97(22): 1852-6, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21873440

RESUMO

OBJECTIVE: While patients with cardiac implantable electronic devices could benefit from magnetic resonance (MR) imaging, the presence of such devices has been designated as an absolute contraindication to MR. Although scanning algorithms are proposed for cardiac implantable electronic devices, their safety remains uncertain. To address this issue, the safety of serial cardiac MR scans was evaluated in patients with implantable cardioverter defibrillators (ICDs). METHODS: Three serial cardiac MR scans were prospectively performed at 1.5 T on 10 patients (9 men) of median age 56 years (range 51-68) with ICDs. ICD interrogation was performed before and after the MR scan and at a follow-up of median 370 days (range 274-723). Image quality was also assessed. RESULTS: In all patients MR scanning occurred without complications. There were no differences between pre- and post-MR pacing capture threshold, pacing lead or high voltage lead impedance, or battery voltage values. During follow-up there were no occurrences of ICD dysfunction. Although most patients had image artifacts, the studies were generally diagnostic regarding left ventricular function and wall motion. Delayed enhancement imaging was of good quality for inferior wall and inferolateral infarcts, but ICD artifacts often affected the imaging of anterior wall infarcts. CONCLUSION: Serial MR scans at 1.5 T in patients with ICDs, when carefully performed in a monitored setting, have no adverse effects on either patient or device. When required, single or multiple MR scans at 1.5 T may therefore be considered for clinical diagnostic purposes in these patients.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Idoso , Segurança de Equipamentos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa