Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Periodontal Res ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38757372

RESUMO

AIM: Evidence suggests that translocation of oral pathogens through the oral-gut axis may induce intestinal dysbiosis. This study aimed to evaluate the impact of a highly leukotoxic Aggregatibacter actinomycetemcomitans (Aa) strain on the gut microbiota, intestinal mucosal integrity and immune system in healthy mice. METHODS: Eight-week-old male C57BL6 mice were divided into control (n = 16) and JP2 groups (n = 19), which received intragastric gavage with PBS and with a suspension of Aa JP2 (HK921), respectively, twice a week for 4 weeks. Colonic lamina propria, fecal material, serum, gingival tissues, and mandibles were obtained for analyses of leukocyte populations, inflammatory mediators, mucosal integrity, alveolar bone loss, and gut microbiota. Differences between groups for these parameters were examined by non-parametric tests. RESULTS: The gut microbial richness and the number of colonic macrophages, neutrophils, and monocytes were significantly lower in Aa JP2-infected mice than in controls (p < .05). In contrast, infected animals showed higher abundance of Clostridiaceae, Lactobacillus taiwanensis, Helicobacter rodentium, higher levels of IL-6 expression in colonic tissues, and higher splenic MPO activity than controls (p < .05). No differences in tight junction expression, serum endotoxin levels, and colonic inflammatory cytokines were observed between groups. Infected animals presented also slightly more alveolar bone loss and gingival IL-6 levels than controls (p < .05). CONCLUSION: Based on this model, intragastric administration of Aa JP2 is associated with changes in the gut ecosystem of healthy hosts, characterized by less live/recruited myeloid cells, enrichment of the gut microbiota with pathobionts and decrease in commensals. Negligible levels of colonic pro-inflammatory cytokines, and no signs of mucosal barrier disruption were related to these changes.

2.
J Clin Densitom ; 27(2): 101467, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38306807

RESUMO

INTRODUCTION: Poor eating habits and a sedentary lifestyle can impair health. Regular physical activity improves the quality of life and is essential for bone health. Therefore, the present study aimed to evaluate the effects of the cafeteria diet on bone quality of sedentary and exercised rats. METHODS: Sixty young male Wistar rats were divided into six groups (n=10) according to diet composition and activity level, being: SD+CON, standard diet and control; SD+SED, standard diet and sedentary; SD+EX, standard diet and exercised; CD+CON, cafeteria diet and control; CD+SED, cafeteria diet and sedentary; CD+EX, cafeteria diet and exercised. The exercise protocol consisted of 10 ladder-climbing sessions/day, 5 days/week, and the sedentary rats were maintained in individual cages with limited mobility. Body mass and food intake were evaluated weekly. After 10 weeks, the animals were euthanized, and white adipose tissue was collected. The bone structure was evaluated by densitometry, mechanical tests, histomorphometric, and micro-computed tomography analyses. RESULTS: The cafeteria diet increased adipose tissue (p<0.001), decreased bone mineral density (p=0.004), and impaired biomechanical properties (p<0.05) and histomorphometry parameters (p=0.044). The sedentarism decreased bone mineral density (p<0.001) and biomechanical properties (p<0.05), and the exercise did not improve bone properties. CONCLUSION: In this experimental model, it was concluded that the cafeteria diet and a sedentary lifestyle negatively affect bone, and ladder-climbing exercise could not prevent the effects of the unhealthy diet.


Assuntos
Densidade Óssea , Condicionamento Físico Animal , Ratos Wistar , Comportamento Sedentário , Microtomografia por Raio-X , Animais , Masculino , Condicionamento Físico Animal/fisiologia , Ratos , Dieta , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/metabolismo , Tecido Adiposo Branco/diagnóstico por imagem
3.
Int Endod J ; 57(6): 700-712, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38404175

RESUMO

AIM: To evaluate the influence of different preparation tapers on the reduction in planktonic bacteria and biofilms of Enterococcus faecalis and Candida albicans in the apical third (4 mm) of the mesial roots of mandibular molars, correlating decontamination with canal shape. METHODOLOGY: After microtomography analysis for morphological standardization of the canals, 48 mandibular molar roots, each containing two canals (96 canals), were contaminated with E. faecalis and C. albicans and divided into four groups (n = 11) for canal instrumentation using ProDesign Logic 2 files with different tapers G (.03): # 25.03; G (.04): # 25.04; G (.05): # 25.05; and G (.06): # 25.06 and irrigation with 2.5% sodium hypochlorite. Four roots were examined under a scanning electron microscope (SEM) to qualitatively assess biofilm formation. Eight roots were used as the negative control group (samples were not contaminated). Bacteriological samples were taken exclusively from the apical third of the roots before and after chemical-mechanical preparation and bacterial counts were determined (CFU/mL). The final micro-CT scan was used to quantify the volume variation and unprepared canal area in the apical third. Statistical analysis was performed using the Kruskal-Wallis, Student-Newman-Keuls and Wilcoxon tests for analysis of microbiological data. anova and the Tukey or Games-Howell test were used for analysis of micro-CT data and Spearman's test for correlations (α = 5%). RESULTS: All groups showed a significant reduction in bacteria (p < .05), with no statistically significant difference between groups. There was no significant difference in per cent volume increase between groups. The unprepared area (Δ%) was affected by the file used (p = .026) and was significantly lower for G (.06) compared to G (.03). There was no statistically significant correlation among bacterial reduction, volume and unprepared area (p > .05). CONCLUSION: The different preparation tapers influenced root canal shaping in the apical third but did not improve decontamination in this region.


Assuntos
Biofilmes , Candida albicans , Cavidade Pulpar , Enterococcus faecalis , Preparo de Canal Radicular , Microtomografia por Raio-X , Microtomografia por Raio-X/métodos , Humanos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Candida albicans/isolamento & purificação , Candida albicans/fisiologia , Cavidade Pulpar/microbiologia , Cavidade Pulpar/diagnóstico por imagem , Hipoclorito de Sódio/uso terapêutico , Hipoclorito de Sódio/farmacologia , Microscopia Eletrônica de Varredura , Dente Molar/microbiologia , Plâncton , Irrigantes do Canal Radicular/administração & dosagem , Irrigantes do Canal Radicular/uso terapêutico , Técnicas In Vitro , Ápice Dentário/microbiologia , Ápice Dentário/diagnóstico por imagem
4.
Int Endod J ; 57(1): 100-107, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37886883

RESUMO

AIM: This study compared intracanal removal of filling as well as the frequency and volume of extruded material after retreatment with either HyFlex or Reciproc instruments in mandibular teeth from cadavers. METHODOLOGY: The root canals of 14 pairs of contralateral single-rooted teeth in mandibles of cadavers were instrumented with Reciproc R40 and filled using lateral compaction. The mandibles were scanned in a micro-computed tomographic (micro-CT) device before and after retreatment procedures. The contralateral teeth were assigned to two groups (n = 14) according to the retreatment protocol using either HyFlex or Reciproc instrument systems. In the HyFlex group, the HyFlex Remover instrument was worked 3 mm short of the working length (WL), followed by HyFlex CM 40.04 and 50.04 at the WL. In the Reciproc group, the R50 instrument was worked up at the coronal two thirds, followed by two more cycles until the WL was reached. Pre- and post-operative micro-CT images were analysed for extrusion and intracanal removal of filling material. RESULTS: After retreatment, extrusion of filling material occurred in 11 (78%) and 14 (100%) teeth from HyFlex and Reciproc groups respectively (p > .05). A similar volume of extruded material was observed after retreatment with both systems (p > .05). A significant decrease in the intracanal filling volume was verified after retreatment with both tested systems (p < .05). However, residual filling material was found in all root canals, regardless of the system. The amount of filling material removed (HyFlex = 80.8%; Reciproc = 65.9%) and the operation time was similar between systems (p > .05). CONCLUSIONS: A high frequency of filling material extrusion was observed after retreatment with the two systems in a cadaver model, with no significant difference between them. Both protocols obtained similar efficacy in filling material removal procedures, although none completely cleaned the canals.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Guta-Percha , Obturação do Canal Radicular , Preparo de Canal Radicular , Instrumentos Odontológicos , Retratamento , Microtomografia por Raio-X/métodos , Cavidade Pulpar
5.
J Prosthet Dent ; 131(6): 1159.e1-1159.e10, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38580583

RESUMO

STATEMENT OF PROBLEM: The type of veneer preparation is often chosen according to the patient's tooth structure and occlusion. Taking biomechanics into account in this decision-making process provides the clinician with more technical information on how to improve the clinical longevity of restorations. However, biomechanical analyses of veneer preparation designs are sparse. PURPOSE: The purpose of this 3-dimensional (3D) finite element analysis with microcomputed tomography (µCT) data obtained from realistic models was to assess the influence of different preparations for ceramic and composite resin veneers on restoration and resin layer stress distribution. MATERIAL AND METHODS: Four replicas of a central incisor were printed and prepared for laminate veneers with 4 different incisal edge designs: shoulder (SH), palatal chamfer (PC), palatal chamfer and oblique fracture involving the distal angle (OF-PC), and palatal chamfer involving horizontal incisal fracture (IF-PC). After fabrication and cementation of the veneers, the restored replicas were assessed with µCT, and 3D finite element models were built. A 100-N load was applied on the palatal surface at 60 and 125 degrees relative to the longitudinal axis. Maximum principal stress and stress distribution on the veneers, cement layer, and tooth structure were calculated and analyzed. RESULTS: The SH preparation exhibited better stress distribution than the PC preparation, and the cement layer and the veneer were subjected to lower stress. The IF-PC preparation had better stress distribution than the OF-PC. The shoulder and IF-PC showed higher stress on laminate veneers, but lower stress on the cement layer. Ceramic veneers exhibited lower stress than composite resin veneers. CONCLUSIONS: The different incisal preparations for laminate veneers influenced stress distribution on restorations and on the resin cement layer. The shoulder type preparation showed better stress distribution and the composite resin veneers showed unfavorable results compared with the ceramic veneers.


Assuntos
Resinas Compostas , Facetas Dentárias , Análise de Elementos Finitos , Incisivo , Microtomografia por Raio-X , Humanos , Incisivo/diagnóstico por imagem , Resinas Compostas/química , Microtomografia por Raio-X/métodos , Análise do Estresse Dentário , Planejamento de Prótese Dentária/métodos , Imageamento Tridimensional/métodos , Cerâmica/química , Preparo Prostodôntico do Dente/métodos
6.
J Imaging ; 10(6)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38921603

RESUMO

Addressing the pressing issue of food waste is vital for environmental sustainability and resource conservation. While computer vision has been widely used in food waste reduction research, existing food image datasets are typically aggregated into broad categories (e.g., fruits, meat, dairy, etc.) rather than the fine-grained singular food items required for this research. The aim of this study is to develop a model capable of identifying individual food items to be integrated into a mobile application that allows users to photograph their food items, identify them, and offer suggestions for recipes. This research bridges the gap in available datasets and contributes to a more fine-grained approach to utilising existing technology for food waste reduction, emphasising both environmental and research significance. This study evaluates various (n = 7) convolutional neural network architectures for multi-class food image classification, emphasising the nuanced impact of parameter tuning to identify the most effective configurations. The experiments were conducted with a custom dataset comprising 41,949 food images categorised into 20 food item classes. Performance evaluation was based on accuracy and loss. DenseNet architecture emerged as the top-performing out of the seven examined, establishing a baseline performance (training accuracy = 0.74, training loss = 1.25, validation accuracy = 0.68, and validation loss = 2.89) on a predetermined set of parameters, including the RMSProp optimiser, ReLU activation function, '0.5' dropout rate, and a 160×160 image size. Subsequent parameter tuning involved a comprehensive exploration, considering six optimisers, four image sizes, two dropout rates, and five activation functions. The results show the superior generalisation capabilities of the optimised DenseNet, showcasing performance improvements over the established baseline across key metrics. Specifically, the optimised model demonstrated a training accuracy of 0.99, a training loss of 0.01, a validation accuracy of 0.79, and a validation loss of 0.92, highlighting its improved performance compared to the baseline configuration. The optimal DenseNet has been integrated into a mobile application called FridgeSnap, designed to recognise food items and suggest possible recipes to users, thus contributing to the broader mission of minimising food waste.

7.
J Conserv Dent Endod ; 27(3): 246-251, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38634025

RESUMO

Context: Complementary procedures have been proposed to improve the endodontic retreatments. Aim: The aim of this study was to evaluate, by microcomputed tomography (micro-CT), the dentin wear caused by passive ultrasonic irrigation (PUI) and easy clean (EC) instruments, when used for the final removal of filling material during endodontic retreatment. Methods: Thirty-six mesial roots of the lower first molars were divided into four groups (n = 9), according to the final irrigation and sealer: PUI/AH Plus, EC/AH Plus, PUI/Total Fill (TF), and EC/TF. Canal volume was evaluated, both before and after the final irrigation, by micro-CT analysis. The Kruskal-Wallis test was used to compare the volumes among groups and the paired Wilcoxon test was used to compare the volume values before and after the final irrigation within each group. Results: Both complementary cleaning procedures promoted dentin wear that was observed only when the volume was analyzed for each third of the root canal. In the apical third, both instruments showed significant wear, where the use of the EC instrument resulted in greater wear than the PUI, in teeth filled with both AH Plus and TF BC Sealers (P < 0.05). Conclusion: Both complementary cleaning procedures promoted dentin wear and must be used cautiously.

8.
Braz Dent J ; 35: e245599, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537013

RESUMO

The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.


Assuntos
Implantes Dentários , Brasil , Torque , Implantação Dentária Endóssea
9.
Acta Odontol Latinoam ; 37(1): 34-39, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38920124

RESUMO

The remaining filling material after retreatment can harbor bacteria and organic tissues that can influence the outcome of the therapy. AIM: The aim of this study was to evalúate, by micro-CT, the amount of filling material remaining in the root canal after its removal using WaveOne Gold or ProDesign RT. MATERIAL AND METHOD: Forty human mandibular canines were instrumented with the ProTaper Next system up to the X2 instrument (25.06) and filled with gutta-percha cones and AHPlus. Teeth were divided into 2 groups (n=20): WaveOne Gold 25.07 (WOG) and ProDesign RT 25.08 (PRT) for filling removal, after which they were scanned in a micro-CT device to quantify the volume of remaining filling material. The data were subjected to log 10 transformation, Student 's t-test was performed to account for multiple observationsper sample, significance was set at 5%. RESULTS: Student 's t-test showed that there was no difference between the two systems regarding the volume of remaining filling material in the thirds: apical (p = 0.392), middle (p = 0.065), or cervical (p = 0.918). CONCLUSIÓN: Remaining filling material was present in all groups and both systems were similar in removing root filling material in mandibular canines.


A permanencia de material obturador após o retratamento pode abrigar bactérias e tecidos orgánicos que podem influenciar o resultado da terapia. OBJETIVO: O objetivo deste estudo foi avaliar, por micro-CT, a quantidade de material obturador remanescente no canal radicular após a desobturagdo com WaveOne Gold e ProDesign RT. MATERIAL E MÉTODO: Quarenta caninos inferiores humanos foram instrumentados com o sistema ProTaper Next até o instrumento X2 (25.06) e obturados com cones de guta-percha e AHPlus. Os dentes foram divididos em dois grupos (n=20): WaveOne Gold 25.07 (WOG) e ProDesign RT 25.08 (PRT) e escaneados em micro-CT para quantificagdo do volume de material obturador remanescente. Os dados foram submetidos á transformando log 10, o teste t de Student foi realizado para contabilizar múltiplas observagoes por amostra, a significáncia foi fixada em 5%. RESULTADOS: O teste t de Student mostrou que ndo houve diferenga no volume de material obturador remanescente entre os dois sistemas nos tergos: apical (p = 0,392), médio (p = 0,065) ou cervical (p = 0,918). CONCLUSÃO: O material obturador remanescente estavapresente em todos os grupos e ambos os sistemas foram semelhantes na remogdo do material obturador radicular nos caninos inferiores.


Assuntos
Materiais Restauradores do Canal Radicular , Microtomografia por Raio-X , Humanos , Dente Canino/diagnóstico por imagem , Técnicas In Vitro , Desenho de Equipamento
10.
Iran Endod J ; 19(3): 199-207, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086709

RESUMO

Introduction: This study aimed to compare the effectiveness of two endodontic cleaning techniques, passive ultrasonic irrigation (PUI) and the XP-endo Finisher R (XPR) system, in removing residual filling material during endodontic retreatment procedures. Materials and Methods: Forty mandibular premolars with oval canals were divided into four groups based on the sealer used (AH-Plus or Bio-C Sealer) and the cleaning technique employed (PUI or XPR). To ensure uniformity of canal volume among groups, initial micro-CT scans were conducted. The canals were instrumented, filled, and then re-instrumented before undergoing either PUI or XPR cleaning techniques. Residual filling material volumes were assessed through micro-CT scans, and statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Following instrumentation, there was no significant difference in residual filling material volumes between AH-Plus and Bio-C Sealer groups (1.35 mm3and 1.02 mm3, respectively; P>0.05). However, after supplementary cleaning techniques, XPR-cleaned specimens exhibited significantly less residual material compared to PUI-cleaned specimens (0.01 mm3 and 0.29 mm3 for Bio-C Sealer, and 0.07 mm3 and. 0.30 mm3 for AH-Plus, P<0.05). Conclusion: The XPR system was found to be more effective than PUI in removing residual filling material from Bio-C Sealer-filled root canals. This highlights its potential as a useful supplementary cleaning technique in endodontic retreatment procedures.

11.
Rev Port Cardiol ; 43(8): 459-467, 2024 Aug.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38460748

RESUMO

INTRODUCTION AND OBJECTIVES: Digital health (DH) is a broad concept, bringing together technology and healthcare, that is playing an increasingly important role in the daily routine of healthcare professionals (HCPs) and promises to contribute to the prevention and treatment of cardiovascular disease. There are no solid data on the position of Portuguese HCPs toward the implementation of DH in cardiovascular medicine. This national cross-sectional study aims to provide a snapshot of DH implementation in Portuguese cardiovascular HCP routines and to identify both expectations and barriers to its adoption. METHODS: An 18-question survey was created specifically for this study and distributed to 1174 individuals on the Portuguese Society of Cardiology mailing list. RESULTS: We collected 117 valid responses (response rate 10%). Almost all participants had smartphones and laptops, and two-thirds had tablets. Electronic medical information systems were the most used DH tool (84% of respondents) and were considered the most important for improving cardiovascular care. Implantable technologies (sensors and devices), telemedicine and social media were used by more than two out of three respondents and considered «very important¼ or «extremely important¼ by most of them. Most participants showed positive expectations regarding the impact of DH in cardiovascular medicine: 78% agreed that DH could improve health outcomes, 64% that it promotes health literacy and 63% that it could decrease healthcare costs. The top-rated barriers were patients' inability to use smartphones, limited access to electronic devices, and lack of legal regulation of DH. CONCLUSION: Most Portuguese cardiovascular HCPs had at least three electronic devices (mainly smartphones, laptops and tablets) and showed positive expectations regarding DH's current and future impact on cardiovascular medicine. Patient DH literacy, technology adoption, and DH regulation were identified as the most important barriers to increasing the adoption of DH tools in cardiovascular medicine.


Assuntos
Cardiologia , Doenças Cardiovasculares , Portugal , Humanos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Doenças Cardiovasculares/terapia , Adulto , Atitude do Pessoal de Saúde , Telemedicina , Pessoal de Saúde , Saúde Digital
12.
Micron ; 180: 103611, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447516

RESUMO

Worldwide, some of the largest hydrocarbon reservoirs are located in tropical neritic carbonate deposits. Biostratigraphic and paleoenvironmental analyzes of these sedimentary records are often based on the study of foraminiferal assemblage. Foraminifera-based biozones are widely employed in the oil industry to support drilling processes that, alongside petrophysical prospecting, define interval favorable for exploiting hydrocarbon resources. Both scientific research and the petroleum industry, however, usually apply traditional petrographical and paleontological methods to analyze microfossil assemblages, especially for large benthic foraminifera. New, faster, and more accurate methods based on microCT analyzes have emerged as a valuable high-output tool to obtain high-resolution microfossil records for biostratigraphy and paleoenvironmental reconstructions. This method is also useful for the development of digital databases for artificial intelligence applications. MicroCT analyzes, therefore, lead to faster identification of foraminifera assemblage and support digital access to international foraminifera repositories and reference collections, introducing a new dimension in micropaleontological research.

13.
Aust Endod J ; 50(1): 140-147, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38152976

RESUMO

The objective of the study was to investigate the 5.25% sodium hypochlorite (NaOCl) penetration into the dentinal tubules after different irrigation methods. Seventy canines were stained with 1% crystal violet and divided into groups (n = 20): GEC-EasyClean; GPUI-E1 Irrisonic ultrasonic insert; GXP-XP-Endo finisher; GPC-conventional irrigation and GNC-stained tooth without irrigation. Axial sections (16×) were assessed and irrigant penetration was quantified as a bleaching halo on the surface of the apical, middle and coronal third. In the apical third, GPUI promoted greater NaOCl penetration (p < 0.05). GXP was better than GEC (p < 0.05), as was GPC (p > 0.05). The GPUI and GXP groups were similar in the middle and coronal third (p > 0.05). GPUI and GXP showed better results than GEC (p < 0.05). GPUI was more effective in the apical third and like GXP in the cervical and middle third.


Assuntos
Dentina , Irrigantes do Canal Radicular , Irrigação Terapêutica/métodos , Hipoclorito de Sódio , Ultrassom/métodos
14.
Aust Endod J ; 50(2): 341-351, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38715465

RESUMO

This study assessed canal preparation effects on disinfection and dentin preservation. Thirty mandibular incisors were paired into two experimental groups (n = 10). Following contamination, the initial microbial sample was collected. Instruments 30/0.03 (Group 1) and 30/0.05 (Group 2) were employed and a second sample was obtained. Canals were enlarged using instruments 40/0.03 and 40/0.05, respectively, and a third sample was collected. Final irrigation was performed, and sample S4 obtained. A final scan evaluated volume, surface area, unprepared areas, removed dentin and dentin thickness. Data were analysed using Student t-test, Mann-Whitney, Kruskal-Wallis and Dunn tests. A significant difference was observed between S1 and other time points (p < 0.05). Comparison between groups showed no differences in bacterial loads and in the percentage of microbial reduction (p > 0.05). Group 2 exhibited greater reduction in dentin thickness than group 1 in the mesial aspect of the root (p < 0.05). Instrument 30/0.03 might provide effective disinfection and safety during mandibular incisors canal preparation.


Assuntos
Desinfecção , Incisivo , Mandíbula , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Desinfecção/métodos , Cavidade Pulpar/microbiologia , Desenho de Equipamento , Dentina/microbiologia , Carga Bacteriana
15.
J Cardiovasc Dev Dis ; 11(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38667725

RESUMO

The early management of transferred patients with a large vessel occlusion (LVO) stroke could be improved by identifying patients who are likely to recanalize early. We aim to predict early recanalization based on patient clinical and thrombus imaging characteristics. We included 81 transferred anterior-circulation LVO patients with an early recanalization, defined as the resolution of the LVO or the migration to a distal location not reachable with endovascular treatment upon repeated radiological imaging. We compared their clinical and imaging characteristics with all (322) transferred patients with a persistent LVO in the MR CLEAN Registry. We measured distance from carotid terminus to thrombus (DT), thrombus length, density, and perviousness on baseline CT images. We built logistic regression models to predict early recanalization. We validated the predictive ability by computing the median area-under-the-curve (AUC) of the receiver operating characteristics curve for 100 5-fold cross-validations. The administration of intravenous thrombolysis (IVT), longer transfer times, more distal occlusions, and shorter, pervious, less dense thrombi were characteristic of early recanalization. After backward elimination, IVT administration, DT and thrombus density remained in the multivariable model, with an AUC of 0.77 (IQR 0.72-0.83). Baseline thrombus imaging characteristics are valuable in predicting early recanalization and can potentially be used to optimize repeated imaging workflow.

16.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38132642

RESUMO

BACKGROUND: Regional functional left ventricular (LV) assessment using current imaging techniques remains limited. Inward displacement (InD) has been developed as a novel technique to assess regional LV function via measurement of the regional displacement of the LV endocardial border across each of the 17 LV segments. Currently, normal ranges for InD are not available for clinical use. The aim of this study was to validate the normal reference limits of InD in healthy adults across all LV segments. METHODS: InD was analyzed in 120 healthy subjects with a normal LV ejection fraction, using the three standard long-axis views obtained during cardiac MRI that quantified the degree of inward endocardial wall motion towards the true LV center of contraction. For all LV segments, InD was measured in mm and expressed as a percentage of the theoretical degree of maximal segment contraction towards the true LV centerline. The arithmetic average InD was obtained for each of the 17 segments. The LV was divided into three regions, obtaining average InD at the LV base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). RESULTS: Average InD was 33.4 ± 4.3%. InD was higher in basal and mid-cavity LV segments (32.8 ± 4.1% and 38.1 ± 5.8%) compared to apical LV segments (28.6 ± 7.7%). Interobserver variability correlations for InD were strong (R = 0.80, p < 0.0001). CONCLUSIONS: We provide clinically meaningful reference ranges for InD in subjects with normal LV function, which will emerge as an important screening and assessment imaging tool for a range of HFrEF therapies.

17.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1550089

RESUMO

Abstract: The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.


Resumo O objetivo deste estudo foi avaliar a estabilidade de implante e a microarquitetura óssea em duas técnicas de fresagem, comparando a técnica convencional (CT) e a osseodensificação (OD) (Versah Burs - Jackson - Mississippi - EUA). O torque de inserção do implante (IT), quociente de estabilidade primária (ISQ) e a estrutura trabecular peri-implantar foram avaliados em fragmentos ósseos obtidos de tíbia de porco (n=12), divididos entre CT (n=6) e OD (n=6). Após o procedimento de fresagem, foram instalados implantes (3,5x8,5 mm, Epikut - SIN - São Paulo - Brasil). O IT e o ISQ foram aferidos por meio de um torquimetro digital e análise de frequência de ressonância. Em seguida, os fragmentos ósseos contendo os implantes foram removidos com trefina e analisados ​​por microtomografia computadorizada (µCT, 8,0 µm). A comparação entre os grupos foi realizada por meio do teste-t não-pareado (α=0.05). Os resultados revelaram que a OD promove maior torque de inserção (CT: 7,67 ± 2,44º Ncm; OD: 19,78 ± 5,26 Ncm) (p=0,0005), embora a estabilidade primária não tenha sido diferente (CT: 61.33 ± 4.66; OD:63.25 ± 4.58) (p=0,48). Houve um aumento significativo no volume ósseo peri-implantar (CT: 23,17±3,39 mm3; OD: 32,01±5,75 mm3) (p=0,0089) e parâmetros trabeculares: separação (CT: 0,4357 ± 0,03 mm; OD: 0,3865 ± 0,04 mm) (p=0,0449), número (CT: 1,626 ± 0,18 1/mm; OD: 1,946 ± 0,13 1/mm) (p=0,007) e espessura (CT: 0,1130 ± 0,009 mm; OD: 0,1328 ± 0,015 mm) (p=0,02) O índice de modelo estrutural (SMI) não demostrou diferença estatisticamente significativa (p=0.1228). Concluindo, OD apresenta maiores valores de torque de inserção e promove mudanças benéficas na microarquitetura óssea em comparação com a TC, revelando maior volume ósseo peri-implantar.

18.
Acta odontol. latinoam ; 37(1): 34-39, Jan. 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1563657

RESUMO

ABSTRACT The remaining filling material after retreatment can harbor bacteria and organic tissues that can influence the outcome of the therapy. Aim The aim of this study was to evalúate, by micro-CT, the amount of filling material remaining in the root canal after its removal using WaveOne Gold or ProDesign RT. Material and Method Forty human mandibular canines were instrumented with the ProTaper Next system up to the X2 instrument (25.06) and filled with gutta-percha cones and AHPlus. Teeth were divided into 2 groups (n=20): WaveOne Gold 25.07 (WOG) and ProDesign RT 25.08 (PRT) for filling removal, after which they were scanned in a micro-CT device to quantify the volume of remaining filling material. The data were subjected to log 10 transformation, Student 's t-test was performed to account for multiple observationsper sample, significance was set at 5%. Results Student 's t-test showed that there was no difference between the two systems regarding the volume of remaining filling material in the thirds: apical (p = 0.392), middle (p = 0.065), or cervical (p = 0.918). Conclusión Remaining filling material was present in all groups and both systems were similar in removing root filling material in mandibular canines.


RESUMO A permanencia de material obturador após o retratamento pode abrigar bactérias e tecidos orgánicos que podem influenciar o resultado da terapia. Objetivo O objetivo deste estudo foi avaliar, por micro-CT, a quantidade de material obturador remanescente no canal radicular após a desobturagdo com WaveOne Gold e ProDesign RT. Material e Método Quarenta caninos inferiores humanos foram instrumentados com o sistema ProTaper Next até o instrumento X2 (25.06) e obturados com cones de guta-percha e AHPlus. Os dentes foram divididos em dois grupos (n=20): WaveOne Gold 25.07 (WOG) e ProDesign RT 25.08 (PRT) e escaneados em micro-CT para quantificagdo do volume de material obturador remanescente. Os dados foram submetidos á transformando log10, o teste t de Student foi realizado para contabilizar múltiplas observagoes por amostra, a significáncia foi fixada em 5%. Resultados O teste t de Student mostrou que ndo houve diferenga no volume de material obturador remanescente entre os dois sistemas nos tergos: apical (p = 0,392), médio (p = 0,065) ou cervical (p = 0,918). Conclusao O material obturador remanescente estavapresente em todos os grupos e ambos os sistemas foram semelhantes na remogdo do material obturador radicular nos caninos inferiores.

19.
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1451777

RESUMO

Several agents can cause hemoparasitic diseases in dogs, and blood-sucking arthropods transmit these diseases. These agents can cause several clinical manifestations and, in some cases, can kill the host. Because these agents are essential in animal health, this study aims to detect the frequency of Ehrlichia canis, Rickettsia rickettsii, Anaplasma platys, and Rangelia vitalii by real-time PCR and Babesia vogeli in dogs in the southern region of the city of São Paulo, São Paulo. Of the 98 dog samples, 18 (18.4%) tested positive with real-time polymerase chain reaction for at least one studied agent. Of these 18 samples, 17 tested positive for a single agent (11.2% for B. canis vogeli, 1.02% for R. vitalii, and 5.1% for E. canis), and one showed co-infection with B. canis vogeli and R. vitalii. The results demonstrate the presence of hemoparasites in the studied animals, which can influence the quality and life expectancy of these animals. The Rangeliadetection warns small animal clinicians to include it as a differential diagnosis for hemoparasitosis.(AU)


As hemoparasitoses em cães podem ser causadas por diversos agentes, sendo essas doenças transmitidas por artrópodes hematófagos. Esses agentes podem causar diversas manifestações clínicas e, em alguns casos, podem matar o hospedeiro. Este estudo teve como objetivo detectar por PCR em tempo real a frequência de Ehrlichia canis, Rickettsia rickettsii, Anaplasma platys, Rangelia vitalii e Babesia canis vogeli em amostras de cães da zona sul da cidade de São Paulo, Brasil. Das 98 amostras de cães, 18 (18,4%) testaram positivo com reação em cadeia da polimerase em tempo real para pelo menos um agente estudado. Destas 18 amostras, 17 testaram positivo para um único agente (11,2% para B. canis vogeli, 1,02% para R. vitalii e 5,1% para E. canis), e uma apresentou coinfecção com B. canis vogeli e R. vitalii. Os resultados demonstram a presença de hemoparasitas nos animais estudados, o que pode influenciar a qualidade e a expectativa de vida desses animais. Além disso, é o primeiro relato da detecção de R. vitalli na zona sul de São Paulo e serve de alerta para os clínicos de pequenos animais incluírem esse agente como diagnóstico diferencial para as hemoparasitoses.(AU)


Assuntos
Animais , Infecções por Protozoários/diagnóstico , Babesiose/diagnóstico , Ehrlichiose/diagnóstico , Cães/microbiologia , Brasil , Reação em Cadeia da Polimerase/veterinária , Piroplasmida , Técnicas de Diagnóstico Molecular/veterinária , Ehrlichia canis
20.
Pesqui. bras. odontopediatria clín. integr ; 23: e210162, 2023. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1431047

RESUMO

ABSTRACT Objective: To compare the agreement of images in white light (WL), fluorescence (FL), and digital radiographs (DR), on the diagnosis and treatment decisions for occlusal caries lesions against a micro-CT gold standard. Material and Methods: Ten extracted third molars, with enamel and/or dentin caries (ICDAS 2-4), were included. Occlusal surface images were acquired with an intraoral camera (SoproLife®) in WL and FL modes. DR was obtained using an intraoral X-ray and a semi-direct digital system. A total of 780 images were needed, organized in a template, to be later examined by twenty-six dentists invited to compose the study. The Generalized Estimation Equations model was used to compare the proportions of the correct answers between the three methods and the gold standard. When significant, Bonferroni post-hoc test was used to identify differences (α=5%). Results: Most of the examiners were specialists (76.9%) with 14.5 years of experience. All diagnostic methods were similar and showed low agreement (DR 12.7%, WL 16.5%, and FL 16.5%) compared with gold standard caries diagnostic scores. Regarding treatment decisions, mean agreement for all diagnostic methods was higher (43.2%; p<0.001), and among all methods, WL (48.1%) and FL (51.2%) modes performed better than DR (30.4%, p<0.001). Conclusion: SoproLife® images could help clinicians to propose rational, minimally invasive treatments for occlusal caries lesions.


Assuntos
Humanos , Cárie Dentária/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Fluorescência , Tomada de Decisão Clínica , Dente Serotino/lesões , Efetividade , Técnicas In Vitro/métodos , Estudos Transversais/métodos , Radiografia Dentária Digital/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa