Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Thorax ; 78(4): 354-361, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35580898

RESUMO

RATIONALE: In patients with COVID-19 pneumonia and mild hypoxaemia, the clinical benefit of high-flow nasal oxygen (HFNO) remains unclear. We aimed to examine whether HFNO compared with conventional oxygen therapy (COT) could prevent escalation of respiratory support in this patient population. METHODS: In this multicentre, randomised, parallel-group, open-label trial, patients with COVID-19 pneumonia and peripheral oxygen saturation (SpO2) ≤92% who required oxygen therapy were randomised to HFNO or COT. The primary outcome was the rate of escalation of respiratory support (ie, continuous positive airway pressure, non-invasive ventilation or invasive mechanical ventilation) within 28 days. Among secondary outcomes, clinical recovery was defined as the improvement in oxygenation (SpO2 ≥96% with fractional inspired oxygen (FiO2) ≤30% or partial pressure of arterial carbon dioxide/FiO2 ratio >300 mm Hg). RESULTS: Among 364 randomised patients, 55 (30.3%) of 181 patients assigned to HFNO and 70 (38.6%) of 181 patients assigned to COT underwent escalation of respiratory support, with no significant difference between groups (absolute risk difference -8.2% (95% CI -18% to +1.4%); RR 0.79 (95% CI 0.59 to 1.05); p=0.09). There was no significant difference in clinical recovery (69.1% vs 60.8%; absolute risk difference 8.2% (95% CI -1.5% to +18.0%), RR 1.14 (95% CI 0.98 to 1.32)), intensive care unit admission (7.7% vs 11.0%, absolute risk difference -3.3% (95% CI -9.3% to +2.6%)), and in hospital length of stay (11 (IQR 8-17) vs 11 (IQR 7-20) days, absolute risk difference -1.0% (95% CI -3.1% to +1.1%)). CONCLUSIONS: Among patients with COVID-19 pneumonia and mild hypoxaemia, the use of HFNO did not significantly reduce the likelihood of escalation of respiratory support. TRIAL REGISTRATION NUMBER: NCT04655638.


Assuntos
COVID-19 , Humanos , COVID-19/complicações , COVID-19/terapia , Oxigênio , Oxigenoterapia , Hipóxia/etiologia , Hipóxia/terapia , Respiração Artificial
2.
BMC Health Serv Res ; 20(1): 1035, 2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-33176775

RESUMO

BACKGROUND: To cope with shortages of equipment during the COVID-19 pandemic, we established a nonprofit end-to-end system to identify, validate, regulate, manufacture, and distribute 3D-printed medical equipment. Here we describe the local and global impact of this system. METHODS: Together with critical care experts, we identified potentially lacking medical equipment and proposed solutions based on 3D printing. Validation was based on the ISO 13485 quality standard for the manufacturing of customized medical devices. We posted the design files for each device on our website together with their technical and printing specifications and created a supply chain so that hospitals from our region could request them. We analyzed the number/type of items, petitioners, manufacturers, and catalogue views. RESULTS: Among 33 devices analyzed, 26 (78·8%) were validated. Of these, 23 (88·5%) were airway consumables and 3 (11·5%) were personal protective equipment. Orders came from 19 (76%) hospitals and 6 (24%) other healthcare institutions. Peak production was reached 10 days after the catalogue was published. A total of 22,135 items were manufactured by 59 companies in 18 sectors; 19,212 items were distributed to requesting sites during the busiest days of the pandemic. Our online catalogue was also viewed by 27,861 individuals from 113 countries. CONCLUSIONS: 3D printing helped mitigate shortages of medical devices due to problems in the global supply chain.


Assuntos
Infecções por Coronavirus/epidemiologia , Equipamentos e Provisões/provisão & distribuição , Pandemias , Equipamento de Proteção Individual/provisão & distribuição , Pneumonia Viral/epidemiologia , Impressão Tridimensional , COVID-19 , Hospitais , Humanos
3.
Thorax ; 74(7): 715-717, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31028239

RESUMO

Episodes of patient-ventilator asynchrony (PVA) occur during acute and chronic non-invasive positive pressure ventilation (NIV). In long-term NIV, description and quantification of PVA is not standardised, thus limiting assessment of its clinical impact. The present report provides a framework for a systematic analysis of polygraphic recordings of patients under NIV for the detection and classification of PVA validated by bench testing. The algorithm described uses two different time windows: rate asynchrony and intracycle asynchrony. This approach should facilitate further studies on prevalence and clinical impact of PVA in long-term NIV.


Assuntos
Ventilação não Invasiva/métodos , Insuficiência Respiratória/terapia , Algoritmos , Humanos , Hipercapnia/terapia , Monitorização Fisiológica/métodos , Ventilação não Invasiva/efeitos adversos , Polissonografia , Insuficiência Respiratória/fisiopatologia , Fenômenos Fisiológicos Respiratórios , Processamento de Sinais Assistido por Computador
4.
Eur Respir J ; 54(3)2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31467119

RESUMO

BACKGROUND: While the role of acute non-invasive ventilation (NIV) has been shown to improve outcome in acute life-threatening hypercapnic respiratory failure in COPD, the evidence of clinical efficacy of long-term home NIV (LTH-NIV) for management of COPD is less. This document provides evidence-based recommendations for the clinical application of LTH-NIV in chronic hypercapnic COPD patients. MATERIALS AND METHODS: The European Respiratory Society task force committee was composed of clinicians, methodologists and experts in the field of LTH-NIV. The committee developed recommendations based on the GRADE (Grading, Recommendation, Assessment, Development and Evaluation) methodology. The GRADE Evidence to Decision framework was used to formulate recommendations. A number of topics were addressed under a narrative format which provides a useful context for clinicians and patients. RESULTS: The task force committee delivered conditional recommendations for four actionable PICO (target population-intervention-comparator-outcome) questions, 1) suggesting for the use of LTH-NIV in stable hypercapnic COPD; 2) suggesting for the use of LTH-NIV in COPD patients following a COPD exacerbation requiring acute NIV 3) suggesting for the use of NIV settings targeting a reduction in carbon dioxide and 4) suggesting for using fixed pressure support as first choice ventilator mode. CONCLUSIONS: Managing hypercapnia may be an important intervention for improving the health outcome of COPD patients with chronic respiratory failure. The task force conditionally supports the application of LTH-NIV to improve health outcome by targeting a reduction in carbon dioxide in COPD patients with persistent hypercapnic respiratory failure. These recommendations should be applied in clinical practice by practitioners that routinely care for chronic hypercapnic COPD patients.


Assuntos
Ventilação não Invasiva/normas , Respiração com Pressão Positiva/normas , Doença Pulmonar Obstrutiva Crônica/terapia , Pneumologia/normas , Progressão da Doença , Europa (Continente) , Medicina Baseada em Evidências , Serviços de Assistência Domiciliar , Humanos , Hipercapnia/terapia , Guias de Prática Clínica como Assunto , Insuficiência Respiratória/terapia , Resultado do Tratamento
5.
Eur Respir J ; 43(2): 545-53, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23845720

RESUMO

Pneumococcal serotypes are one of the main determinants of pneumococcal disease severity; however, data about their implication in respiratory failure are scarce. We conducted an observational study of adults hospitalised with invasive pneumococcal pneumonia to describe the host- and pathogen-related factors associated with respiratory failure. Of 1258 adults with invasive pneumococcal disease, 615 (48.9%) had respiratory failure at presentation. Patients with respiratory failure were older (62.1 years versus 55.4 years, p<0.001) and had a greater proportion of comorbid conditions. They also had a greater proportion of septic shock (41.7% versus 6.1%, p<0.001), required admission to the intensive care unit more often (38.4% versus 4.2%, p<0.001) and had a higher mortality (25.5% versus 3.5%, p<0.001). After adjustment, independent risk factors for respiratory failure were: age >50 years (OR 1.63, 95% CI 1.15-2.3), chronic lung disease (OR 1.54, 95% CI 1.1-2.15), chronic heart disease (OR 1.49, 95% CI 1.01-2.22) and infection caused by serotypes 3 (OR 1.97, 95% CI 1.23-3.16), 19A (OR 2.34, 95% CI 1.14-4.42) and 19F (OR 3.55, 95% CI 1.22-10.28). In conclusion, respiratory failure is a frequent complication of pneumococcal pneumonia and causes high morbidity and mortality. Pneumococcal serotypes 3, 19A and 19F are the main risk factors for this complication.


Assuntos
Pneumonia Pneumocócica/complicações , Insuficiência Respiratória/complicações , Streptococcus pneumoniae/classificação , Adulto , Idoso , Antibacterianos/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vacinas Pneumocócicas , Pneumonia Pneumocócica/microbiologia , Insuficiência Respiratória/microbiologia , Insuficiência Respiratória/mortalidade , Fatores de Risco , Sorotipagem , Choque Séptico , Espanha , Resultado do Tratamento
6.
Scand J Infect Dis ; 46(3): 185-92, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24456230

RESUMO

BACKGROUND: The incidence of invasive pneumococcal disease (IPD) appears to be associated with influenza. The objectives of this study were to evaluate the changes in IPD incidence and clinical data as well as the trends in Streptococcus pneumoniae serotype distribution in adults during the peak period of the 2009 influenza A H1N1 pandemic (IAP). METHODS: We performed a prospective multicentre study on IPD from week 42 to 48, 2009 in an area of Barcelona (Catalonia, Spain) covering 1,483,781 adult inhabitants. Serotyping was done by Quellung reaction. The data from 2009 were compared to those from the same periods in 2008 and 2010. RESULTS: Two hundred and three cases of IPD were detected during 2009, compared with 182 in 2008 and 139 in 2010. The incidence of IPD during the 7-week study period in 2009 (2.89) was statistically higher than that observed in 2008 (1.96) and 2010 (1.46). IAP was confirmed in 3/30 patients during the 2009 study period. Patients with IPD in 2009 were significantly healthier and younger than those in the other years, although the mortality was higher than in 2008 (p = 0.05) and 2010 (p > 0.05). Eleven (10 non-PCV-7) serotypes not present in 2008 appeared in 2009. CONCLUSIONS: During weeks 42 to 48, in which the 2009 IAP peaked in Catalonia, the incidence of IPD was statistically higher than that observed in the same time period in 2008 and 2010, with some differences in the epidemiological data, showing a close relationship between S. pneumoniae and influenza.


Assuntos
Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Influenza Humana/epidemiologia , Influenza Humana/virologia , Pandemias/estatística & dados numéricos , Infecções Pneumocócicas/epidemiologia , Infecções Pneumocócicas/microbiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infecções Pneumocócicas/virologia , Estudos Prospectivos , Fatores de Risco , Streptococcus pneumoniae/classificação , Streptococcus pneumoniae/isolamento & purificação , Adulto Jovem
7.
J Clin Med ; 13(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38731172

RESUMO

Mechanical insufflation-exsufflation (MI-E) is essential for secretion clearance, especially in neuromuscular disorders. For the best outcomes, initiation of MI-E should be started at the correct time with regular evaluation to the response to treatment. Typically, cough peak flow has been used to evaluate cough effectiveness with and without MI-E. This review highlights the limitations of this and discussed other tools to evaluate MI-E efficacy in this rapidly developing field. Such tools include the interpretation of parameters (like pressure, flow and volumes) that derive from the MI-E device and external methods to evaluate upper airway closure. In this review we pinpoint the differences between different devices in the market and discuss new tools to better titrate MI-E and detect pathological responses of the upper airway. We discuss the importance of point of care ultrasound (POCUS), transnasal fiberoptic laryngoscopy and wave form analysis in this setting. To improve clinical practice newer generation MI-E devices should allow real-time evaluation of waveforms and standardize some of the derived parameters.

8.
Arch Bronconeumol ; 2024 May 04.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38782632

RESUMO

INTRODUCTION: The effectiveness of home high flow nasal cannula (HFNC) for the treatment of chronic respiratory failure in patients with chronic respiratory diseases (CRDs) has not been summarized. We aimed to conduct a systematic review of the effectiveness, adherence, and safety of HFNC in the long-term treatment of patients with chronic respiratory diseases and respiratory failure. METHODS: A systematic review was conducted. PubMed, Web of science, and SCOPUS were search up to August 2023. Long-term HFNC studies (≥4 weeks) reporting dyspnea; exacerbations, hospitalizations; peripheral oxygen saturation (SpO2), comfort; patient experience, health-related quality of life or partial pressure of carbon dioxide (paCO2) were included. RESULTS: Thirteen articles (701 patients) based on 10 studies were selected: randomized control trials (n=3), randomized crossover trials (n=2), crossover (n=3) and retrospective (n=2) studies. COPD (n=6), bronchiectasis (n=2), COPD/bronchiectasis (n=1) and ILD (n=1) were the underlined CRDs. HFNC reduced exacerbations when compared to usual care/home respiratory therapies (n=6). Quality of life outcomes were also in favor of HFNC in patients with COPD and bronchiectasis (n=6). HFNC had significant effects on hospitalizations, paCO2, and lung function. Adherence ranged from 5.2 to 8.6h/day (n=5). Three studies reported no events, 3 non-serious events and 2 no differences compared with other home respiratory therapies. CONCLUSIONS: HFNC seems more effective than usual care or other home respiratory therapies in reducing exacerbations and improving quality of life in patients with COPD and bronchiectasis, while presenting good adherence and being safe. Its apparently superior effectiveness needs to be better studied in future real-world pragmatic trials.

9.
Expert Rev Respir Med ; 18(3-4): 227-236, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38829281

RESUMO

BACKGROUND: Thoraco-abdominal asynchrony (TAA) is usually assessed by respiratory inductance plethysmography. The main parameter used for its assessment is the calculation of the phase angle based on Lissajous plots. However, there are some mathematical limitations to its use. RESEARCH DESIGN AND METHODS: Sequences of five breaths were selected from a) normal subjects, b) COPD patients, both at rest and during exercise, and c) patients with obstructive apnea syndrome. Automated analysis was performed calculating phase angle, loop rotation (clockwise or counterclockwise), global phase delay and loop area. TAA severity was estimated quantitatively and in subgroups. RESULTS: 2290 cycles were analyzed (55% clockwise rotation). Phase angle ranged from -86.90 to + 88.4 degrees, while global phase delay ranged from -179.75 to + 178.54. Despite a good correlation with global phase delay (p < 0.01, ANOVA test), phase angle and loop area were not able to correctly classify breaths with severe deviation and paradoxical movements (p=ns, Bonferroni post hoc test). CONCLUSIONS: Global phase delay covers the whole spectrum of TAA situations in a single value. It may be a relevant parameter for diagnosis and follow-up of clinical conditions leading to TAA. CLINICAL TRIAL REGISTRATION: The trial from which the traces were obtained was registered at ClinicalTrials.gov ;(identifier: NCT04597606).


Assuntos
Pletismografia , Doença Pulmonar Obstrutiva Crônica , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Abdome/fisiopatologia , Pletismografia/métodos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Respiração , Mecânica Respiratória/fisiologia
10.
Arch Bronconeumol ; 60(5): 285-295, 2024 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38521646

RESUMO

Acute respiratory failure due to COVID-19 pneumonia often requires a comprehensive approach that includes non-pharmacological strategies such as non-invasive support (including positive pressure modes, high flow therapy or awake proning) in addition to oxygen therapy, with the primary goal of avoiding endotracheal intubation. Clinical issues such as determining the optimal time to initiate non-invasive support, choosing the most appropriate modality (based not only on the acute clinical picture but also on comorbidities), establishing criteria for recognition of treatment failure and strategies to follow in this setting (including palliative care), or implementing de-escalation procedures when improvement occurs are of paramount importance in the ongoing management of severe COVID-19 cases. Organizational issues, such as the most appropriate setting for management and monitoring of the severe COVID-19 patient or protective measures to prevent virus spread to healthcare workers in the presence of aerosol-generating procedures, should also be considered. While many early clinical guidelines during the pandemic were based on previous experience with acute respiratory distress syndrome, the landscape has evolved since then. Today, we have a wealth of high-quality studies that support evidence-based recommendations to address these complex issues. This document, the result of a collaborative effort between four leading scientific societies (SEDAR, SEMES, SEMICYUC, SEPAR), draws on the experience of 25 experts in the field to synthesize knowledge to address pertinent clinical questions and refine the approach to patient care in the face of the challenges posed by severe COVID-19 infection.


Assuntos
COVID-19 , Ventilação não Invasiva , Humanos , COVID-19/complicações , COVID-19/terapia , Insuficiência Respiratória/terapia , Insuficiência Respiratória/etiologia , Oxigenoterapia , Consenso , SARS-CoV-2 , Pandemias , Comunicação Interdisciplinar , Respiração com Pressão Positiva
11.
Clin Infect Dis ; 57(12): 1722-30, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24065334

RESUMO

BACKGROUND: The 13-valent pneumococcal conjugate vaccine (PCV13) has recently been approved for use in immunocompromised adults. However, it is unclear whether there is an association between specific underlying conditions and infection by individual serotypes. The objective was to determine the prevalence of serotypes covered by PCV13 in a cohort of patients with invasive pneumococcal disease of respiratory origin and to determine whether there are specific risk factors for each serotype. METHODS: An observational study of adults hospitalized with invasive pneumococcal disease in 2 Spanish hospitals was conducted during the period 1996-2011. A multinomial regression analysis was performed to identify conditions associated with infection by specific serotypes (grouped according their formulation in vaccines and individually). RESULTS: A total of 1094 patients were enrolled; the infecting serotype was determined in 993. In immunocompromised patients, 64% of infecting serotypes were covered by PCV13. After adjusting for age, smoking, alcohol abuse, and nonimmunocompromising comorbidities, the group of serotypes not included in either PCV13 or PPV23 were more frequently isolated in patients with immunocompromising conditions and cardiopulmonary comorbidities. Regarding individual serotypes, 6A, 23F, 11A, and 33F were isolated more frequently in patients with immunocompromise and specifically in some of their subgroups. The subgroup analysis showed that serotype10A was also associated with HIV infection. CONCLUSIONS: Specific factors related to immunocompromise seem to determine the appearance of invasive infection by specific pneumococcal serotypes. Although the coverage of serotypes in the 13-valent conjugate pneumococcal vaccine (PCV13) was high, some non-PCV13-emergent serotypes are more prevalent in immunocompromised patients.


Assuntos
Vacinas Pneumocócicas/administração & dosagem , Pneumonia Pneumocócica/imunologia , Pneumonia Pneumocócica/microbiologia , Streptococcus pneumoniae/classificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Comorbidade , Infecções por HIV/microbiologia , Humanos , Hospedeiro Imunocomprometido , Pessoa de Meia-Idade , Neoplasias/microbiologia , Pneumonia Pneumocócica/prevenção & controle , Streptococcus pneumoniae/imunologia , Streptococcus pneumoniae/isolamento & purificação
12.
BMC Pulm Med ; 13: 75, 2013 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-24325396

RESUMO

BACKGROUND: So far, the accuracy of tidal volume (VT) and leak measures provided by the built-in software of commercial home ventilators has only been tested using bench linear models with fixed calibrated and continuous leaks. The objective was to assess the reliability of the estimation of tidal volume (VT) and unintentional leaks in a single tubing bench model which introduces random dynamic leaks during inspiratory or expiratory phases. METHODS: The built-in software of four commercial home ventilators and a fifth ventilator-independent ad hoc designed external software tool were tested with two levels of leaks and two different models with excess leaks (inspiration or expiration). The external software analyzed separately the inspiratory and expiratory unintentional leaks. RESULTS: In basal condition, all ventilators but one underestimated tidal volume with values ranging between -1.5 ± 3.3% to -8.7% ± 3.27%. In the model with excess of inspiratory leaks, VT was overestimated by all four commercial software tools, with values ranging from 18.27 ± 7.05% to 35.92 ± 17.7%, whereas the ventilator independent-software gave a smaller difference (3.03 ± 2.6%). Leaks were underestimated by two applications with values of -11.47 ± 6.32 and -5.9 ± 0.52 L/min. With expiratory leaks, VT was overestimated by the software of one ventilator and the ventilator-independent software and significantly underestimated by the other three, with deviations ranging from +10.94 ± 7.1 to -48 ± 23.08%. The four commercial tools tested overestimated unintentional leaks, with values between 2.19 ± 0.85 to 3.08 ± 0.43 L/min. CONCLUSIONS: In a bench model, the presence of unintentional random leaks may be a source of error in the measurement of VT and leaks provided by the software of home ventilators. Analyzing leaks during inspiration and expiration separately may reduce this source of error.


Assuntos
Serviços de Assistência Domiciliar , Monitorização Fisiológica/instrumentação , Software , Ventiladores Mecânicos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Volume de Ventilação Pulmonar
13.
J Clin Med ; 12(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37109277

RESUMO

The choice of a ventilator model for a single patient is usually based on parameters such as size (portability), presence or absence of battery and ventilatory modes. However, there are many details within each ventilator model about triggering, pressurisation or autotitration algorithms that may go unnoticed, but may be important or may justify some drawbacks that may occur during their use in individual patients. This review is intended to emphasize these differences. Guidance is also provided on the operation of autotitration algorithms, in which the ventilator is able to take decisions based on a measured or estimated parameter. It is important to know how they work and their potential sources of error. Current evidence on their use is also provided.

14.
J Clin Med ; 12(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37048774

RESUMO

Most of the published reviews about non-invasive home ventilation mainly reflect the technical aspects of ventilators. There is much less information about the consumables most used at home. However, the choice of a good interface or tubing system can lead to physiological changes in the patient-ventilator interaction that the clinician should be aware of. These physiological changes may affect the performance of the ventilator itself, the reliability of monitoring and, of course, the comfort of the patient. The use of different circuits, masks or filters is therefore related to the concepts of rebreathing, compressible volume, instrumental dead space or leak estimation and tidal volume. Through certain bench experiments, it is possible to determine the implications that each of these elements may have in clinical practice.

15.
J Clin Med ; 12(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685610

RESUMO

BACKGROUND: One of the main features of COVID-19 pneumonia is hypoxemic acute respiratory failure (ARF), often requiring ventilatory support. The influence of chest physiotherapy in patients with ARF is not extensively studied. The aim of the study was to analyze the short-time effects of chest physiotherapy using a 10 cm H2O threshold valve in patients with COVID-19 and ARF. Methods; Quasi-experimental cross-sectional study, in hospitalized patients from March to May 2020. The fractions of inspired oxygen, oxygen saturation, heart rate, respiratory rate and dyspnea were collected before and after the starting session (day 1) and after the 5th day of therapy. RESULTS: The final sample size included 125 patients. Significant differences (p < 0.01) were found in the pre-post intervention SpO2/FiO2 ratio (250 ± 88.4 vs. 275.6 ± 97.5, p < 0.001), reaching 354.4 ± 110.2 after 5 days of therapy (p < 0.001 with respect to the baseline). The respiratory and heart rate dyspnea level did not change during the intervention. In patients needing FiO2 > 0.4, the SpO2/FiO2 ratio improvement was higher than in patients with milder severity (46.85 ± 77.69, p < 0.01). CONCLUSIONS: Chest physiotherapy with a 10 cm H2O threshold valve seems to be a safe and tolerated intervention with short-term improvement in oxygenation in patients with COVID-19 pneumonia.

16.
J Neuromuscul Dis ; 10(4): 627-637, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37212068

RESUMO

BACKGROUND AND OBJECTIVE: Forced vital capacity (FVC) less than 50% of predicted is one of the main parameters used for Non-Invasive Ventilation (NIV) initiation in Amyotrophic Lateral Sclerosis (ALS). Recent studies suggest that higher values of FVC could be considered as a threshold. The aim of this study is to evaluate whether early use of NIV improves the prognosis of ALS patients compared with standard initiation. METHODS: This is a randomized, parallel, multicenter, open-label, controlled clinical trial, with recruitment at the ALS outpatient multidisciplinary units of six Spanish hospitals. Patients were included when their FVC reached the 75% threshold and were randomized by computer, stratifying by center in an allocation ratio of 1:1 to Early NIV (FVC below 75%) or Standard NIV (FVC below 50%) initiation. The primary outcome was time to death or tracheostomy.Trial registration number ClinicalTrials.gov: NCT01641965. RESULTS: Between May 2012 and June 2014, 42 patients were randomized to two groups, 20 to Early NIV and 22 to Standard NIV initiation. We found differences in survival in favor of the intervention group: an incidence of mortality (2.68 [1.87-5.50] vs. 3.33 [1.34-4.80] person-months) and a median survival (25.2 vs. 19.4 months), although without reaching statistical significance (p = 0.267). CONCLUSIONS: This trial did not reach the primary endpoint of survival; nevertheless, it is the first Randomized Controlled Trial (RCT) to demonstrate the benefits of early NIV in slowing the decline of respiratory muscle strength and reducing adverse events. Although not all the results reached statistical significance, all the analyzed data favor early NIV. In addition, this study demonstrates good tolerance and compliance with early NIV without quality of sleep impairment. These data reinforce the early respiratory evaluation of ALS patients and NIV initiation with an FVC of around 75%.


Assuntos
Esclerose Lateral Amiotrófica , Ventilação não Invasiva , Humanos , Esclerose Lateral Amiotrófica/terapia , Ventilação não Invasiva/métodos , Respiração Artificial , Capacidade Vital , Cooperação do Paciente
17.
Sci Rep ; 13(1): 7720, 2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37173327

RESUMO

Computer-assisted diagnosis (CAD) algorithms have shown its usefulness for the identification of pulmonary nodules in chest x-rays, but its capability to diagnose lung cancer (LC) is unknown. A CAD algorithm for the identification of pulmonary nodules was created and used on a retrospective cohort of patients with x-rays performed in 2008 and not examined by a radiologist when obtained. X-rays were sorted according to the probability of pulmonary nodule, read by a radiologist and the evolution for the following three years was assessed. The CAD algorithm sorted 20,303 x-rays and defined four subgroups with 250 images each (percentiles ≥ 98, 66, 33 and 0). Fifty-eight pulmonary nodules were identified in the ≥ 98 percentile (23,2%), while only 64 were found in lower percentiles (8,5%) (p < 0.001). A pulmonary nodule was confirmed by the radiologist in 39 out of 173 patients in the high-probability group who had follow-up information (22.5%), and in 5 of them a LC was diagnosed with a delay of 11 months (12.8%). In one quarter of the chest x-rays considered as high-probability for pulmonary nodule by a CAD algorithm, the finding is confirmed and corresponds to an undiagnosed LC in one tenth of the cases.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Raios X , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade , Neoplasias Pulmonares/diagnóstico por imagem , Diagnóstico por Computador/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem
18.
Artigo em Inglês | MEDLINE | ID: mdl-35058690

RESUMO

PURPOSE: The European Task Force for chronic non-invasive ventilation in stable COPD recommends the use of high pressure-support (PS) level to maximize the decrease in PaCO2. It is possible that the ventilator model can influence the need for higher or lower pressure levels. RESEARCH QUESTION: To determine the differences between ventilators in a bench model with an increased inspiratory demand; and to compare the degree of muscular unloading measured by parasternal electromyogram (EMGpara) provided by the different ventilators in real patients with stable COPD. PATIENTS AND METHODS: Bench: four levels of increasing progressive effort were programmed. The response of nine ventilators to four levels of PS and EPAP of 5 cm H2O was studied. The pressure-time product was determined at 300 and 500 msec (PTP 300/500). CLINICAL STUDY: The ventilators were divided into two groups, based on the result of the bench test. Severe COPD patients with non-invasive ventilation (NIV) were studied, randomly comparing the performance of one ventilator from each group. Muscle unloading was measured by the decrease in EMGpara from its baseline value. RESULTS: There were significant differences in PTP 300 and PTP 500 in the bench study. Based on these results, home ventilators were classified into two groups; group 1 included four models with higher PTP 300. Ten COPD patients were recruited for the clinical study. Group 1 ventilators showed greater muscle unloading at the same PS than group 2. CONCLUSION: The scale of pressure support in NIV for high intensity ventilation may be influenced by the ventilator model. CLINICAL TRIALSGOV: NCT03373175.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Respiração com Pressão Positiva/efeitos adversos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/terapia , Respiração , Respiração Artificial/métodos , Ventiladores Mecânicos
19.
Arch Bronconeumol ; 58(9): 642-648, 2022 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35312537

RESUMO

BACKGROUND: Treatment of chronic hypercapnic failure in COPD patients with home noninvasive ventilation (HNIV) remains unclear. AIM: To create a curated cohort of all COPD patients on HNIV in Catalonia, perform a cluster analysis, and evaluate mortality evolution. STUDY DESIGN AND METHODS: This study was a multicenter, observational study including all COPD patients on HNIV on 1st January of 2018. Patients were selected through the Catalan Health Service, and administrative and clinical data were obtained in the previous four years. Principal component analysis of mixed data and hierarchical clustering were performed to identify clusters of patients. Mortality was evaluated from 1 January 2018 until 31 December 2020. RESULTS: A total of 247 patients were enrolled. They were mostly male (78.1%), with a median (SD) age of 70.4 (9.4) years old. In 60%, 55% and 29% of patients, obesity, sleep apnea and heart failure coexisted, respectively. Cluster analysis identified four well-differentiated groups labeled for their clinical characteristics: (1) obese smokers, (2) very severe COPD, (3) sleep apnea and (4) older comorbid males. Patients belonging to Clusters (2) and (4) had a worse prognosis than patients in Clusters (1) and (3). INTERPRETATION: A high heterogeneity in the prescription of HNIV was demonstrated. Cluster analysis identifies four different groups, of which only one had COPD as the main cause of ventilation, while the other three clusters showed a predominance of other comorbidities. This leads to different survival outcomes, including an overlapping phenotype of obesity-related disease and sleep apnea with better survival.


Assuntos
Ventilação não Invasiva , Doença Pulmonar Obstrutiva Crônica , Síndromes da Apneia do Sono , Análise por Conglomerados , Feminino , Humanos , Masculino , Obesidade , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/terapia , Respiração Artificial
20.
Sci Rep ; 12(1): 6527, 2022 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-35444251

RESUMO

The effectiveness of noninvasive respiratory support in severe COVID-19 patients is still controversial. We aimed to compare the outcome of patients with COVID-19 pneumonia and hypoxemic respiratory failure treated with high-flow oxygen administered via nasal cannula (HFNC), continuous positive airway pressure (CPAP) or noninvasive ventilation (NIV), initiated outside the intensive care unit (ICU) in 10 university hospitals in Catalonia, Spain. We recruited 367 consecutive patients aged ≥ 18 years who were treated with HFNC (155, 42.2%), CPAP (133, 36.2%) or NIV (79, 21.5%). The main outcome was intubation or death at 28 days after respiratory support initiation. After adjusting for relevant covariates and taking patients treated with HFNC as reference, treatment with NIV showed a higher risk of intubation or death (hazard ratio 2.01; 95% confidence interval 1.32-3.08), while treatment with CPAP did not show differences (0.97; 0.63-1.50). In the context of the pandemic and outside the intensive care unit setting, noninvasive ventilation for the treatment of moderate to severe hypoxemic acute respiratory failure secondary to COVID-19 resulted in higher mortality or intubation rate at 28 days than high-flow oxygen or CPAP. This finding may help physicians to choose the best noninvasive respiratory support treatment in these patients.Clinicaltrials.gov identifier: NCT04668196.


Assuntos
COVID-19 , Ventilação não Invasiva , Insuficiência Respiratória , COVID-19/terapia , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Intubação Intratraqueal , Ventilação não Invasiva/métodos , Oxigênio , Insuficiência Respiratória/terapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa