Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev Soc Bras Med Trop ; 50(5): 666-669, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29160514

RESUMO

INTRODUCTION: The objective was to identify comorbidities related to HIV-positive patients in Blumenau, State of Santa Catarina. METHODS: A retrospective, descriptive observational design study which analyzed data from 424 patients assisted by the sexually transmitted disease/acquired immunodeficiency syndrome (STD/AIDS) Specialized Care Service (SCS). RESULTS: Of 424 medical records analyzed, 388 patients presented CD4+/CD8+ ratios lower than 1. The most prevalent comorbidities were smoking, depression, alcoholism, and herpes zoster infection, in males and females. CONCLUSIONS: The most relevant comorbidity in both genders was herpes zoster, an important marker of immunity in patients. The lowest mean was observed among patients with neurotoxoplasmosis.


Assuntos
Síndrome da Imunodeficiência Adquirida/sangue , Síndrome da Imunodeficiência Adquirida/epidemiologia , Relação CD4-CD8/estatística & dados numéricos , Adulto , Alcoolismo/sangue , Alcoolismo/epidemiologia , Brasil/epidemiologia , Comorbidade , Depressão/sangue , Depressão/epidemiologia , Feminino , Herpes Zoster/sangue , Herpes Zoster/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Valores de Referência , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Fumar/sangue , Fumar/epidemiologia , Adulto Jovem
3.
Audiol., Commun. res ; 25: e2280, 2020. tab, graf
Artigo em Português | LILACS | ID: biblio-1131778

RESUMO

RESUMO Objetivo Correlacionar o desempenho de usuários de implante coclear unilateral em testes de reconhecimento de fala, no silêncio e no ruído, com as respostas ao questionário de autoavaliação Hearing Implant Sound Quality Index (HISQUI19) e correlacionar o desempenho em testes de reconhecimento de fala com o tempo de uso do dispositivo e a orelha implantada. Métodos Participaram 27 usuários de implante coclear unilateral com deficiência auditiva pós-lingual, que faziam uso do dispositivo há, pelo menos, um ano e apresentavam limiar tonal em campo livre menor que 40 dBA. Todos os participantes foram submetidos à audiometria tonal em campo livre, responderam ao questionário HISQUI19 e realizaram testes de reconhecimento de fala no silêncio e no ruído. Resultados As respostas ao questionário foram comparadas com os testes de reconhecimento de fala no silêncio e no ruído e não houve diferença estatisticamente significativa. Na comparação em relação ao tempo de uso do implante coclear, só houve diferença estatisticamente significativa para o teste de reconhecimento de fala no silêncio. Não houve correlação significativa entre o reconhecimento de fala e a orelha implantada. Conclusão independentemente do tempo de uso do dispositivo e/ou do desempenho nos testes de reconhecimento de fala, muitos participantes classificaram a qualidade sonora do implante coclear como moderada. A aplicação de testes que possibilitem mensurar a satisfação e o benefício dos usuários deve fazer parte da rotina clínica dos centros de implante.


ABSTRACT Purpose To correlate the performance of unilateral cochlear implant users in speech recognition tests, in quiet and noise, with the answers to the Hearing Implant Sound Quality Index (HISQUI19) self-assessment questionnaire; also, to correlate the performance in speech recognition tests with the time of CI use and the implanted ear. Methods A total of 27 unilateral CI users with postlingual hearing loss, who had been using the device for at least one year and had free-field pure-tone threshold lower than 40 dBA, participated in the study. All the participants were submitted to free-field pure-tone audiometry, answered the HISQUI19 questionnaire, and took speech recognition tests in quiet and noise. Results The answers to the questionnaire were compared with the speech recognition tests in quiet and noise; there was no statistically significant difference. When comparing with the time of CI use, there was a statistically significant difference only for the speech recognition test in quiet. There was no significant correlation between speech recognition and the implanted ear. Conclusion Regardless of the time of CI use and/or performance in the speech recognition tests, many participants classified the sound quality of their cochlear implant as moderate. Administering tests to measure the users' level of satisfaction and benefit should integrate the clinical routine in implantation centers.


Assuntos
Humanos , Testes de Discriminação da Fala , Percepção da Fala , Implante Coclear , Limiar Auditivo , Autoavaliação Diagnóstica , Perda Auditiva
4.
Distúrb. comun ; 32(3): 396-405, set. 2020. tab, ilus
Artigo em Português | LILACS | ID: biblio-1397548

RESUMO

Introdução: A mensuração do benefício proporcionado pelo Implante Coclear é fundamental e há vários métodos de avaliação descritos, mas, os testes de percepção de fala ainda são os mais utilizados, dentre eles a "Lista de Sentenças em Português" - LSP. Determinar os fatores que influenciam o reconhecimento de fala nos usuários de IC auxilia nas orientações da etapa pré-operatória, melhora a adaptação, reabilitação e evidencia mudanças necessárias no dispositivo. Objetivo: Verificar a correlação das variáveis: tempo de privação auditiva e tempo de uso de Implante Coclear (IC) com os resultados dos testes de percepção de fala no silêncio e no ruído em usuários de IC com deficiência auditiva pós-lingual e idade entre 14 e 60 anos. Método: Os 27 participantes foram submetidos às seguintes avaliações: levantamento de dados- para coleta de informações que caracterizem a perda auditiva prévia, como tempo de privação auditiva e início do uso do IC -, audiometria em campo livre com IC nas frequências sonoras de 250 a 4000 Hz e o reconhecimento de fala que foi avaliado por meio do teste "Listas de Sentenças em Português" - LSP aplicado na condição favorável (silêncio) e na condição desfavorável (ruído) de escuta. Na análise estatística foram utilizados o coeficiente de correlação linear de Pearson e gráficos de dispersão bidimensional, além disso, a análise descritiva dos dados. Resultados: Não houve relação estatisticamente significante entre a privação auditiva e a percepção de fala no silêncio e no ruído. Por outro lado, houve correlação positiva estatisticamente significante entre o Tempo de Uso do IC com o desempenho no teste de reconhecimento de sentenças no silêncio. Conclusão: Verificou-se correlação significante apenas entre tempo de uso de implante e reconhecimento de sentenças no silêncio em usuários de implante com surdez pós-lingual.


Introduction: It is essential to measure the benefits provided by the cochlear implant, to which end various assessment methods have been described. Of these, the speech perception tests are still the most used, including the List of Sentences in Portuguese ­ LSP. Determining the factors that influence the speech recognition of CI users helps in preoperative instructions, improves adaptation and rehabilitation, and reveals necessary changes to be made in the device. Purpose: To verify the correlation between time of auditory deprivation and duration of use of the cochlear implant (CI) with the results of the speech perception in silence and noise tests in CI users with post lingual hearing loss aged 14 to 60 years old. Method: The 27 participants were submitted to the following assessments: data collection to characterize the previous hearing loss, such as the time of auditory deprivation and beginning of CI use; free-field audiometry with CI at the frequencies of 250 to 4000 Hz; speech recognition assessed through the Lists of Phrases in Portuguese (LPP), presented in favorable (silence) and unfavorable (noise) hearing conditions. In the statistical analysis, Pearson's linear correlation coefficient was used, as well as bidimensional dispersion graphs and descriptive data analysis. Results: There was no statistically significant relationship between auditory deprivation and speech perception in silence and noise. On the other hand, there was a statistically significant positive correlation between the duration of CI use and the performance in sentence recognition in silence. Conclusion: A significant correlation was verified only between duration of implant use and sentence recognition in silence in implant users with post lingual deafness.


Introduccion: La medición del beneficio proporcionado por el implante coclear es esencial y existen varios métodos para evaluar lãs pruebas, pero lãs pruebas de percepción Del habla son aún más utilizadas, entre ellas la "Lista de oraciones em portugués" - LSP. Determinar los factores que influyen o El reconocimiento de lãs conversaciones em los usuários del IC auxiliar em lãs instrucciones pre-operatorias, mejora La adaptación, la rehabilitación y la evidencia de cambios alterados em el dispositivo.Objetivo: Verifique la correlación de las variables: tiempo de privación auditiva y tiempo de uso del implante coclear (CI) com los resultados de las pruebas de percepción del habla en silencio y el ruído em usuarios de CI com audición poslingual y edad entre 14 y 60 años. Método: los 27 participantes se sometieron a los siguientes pasos: recopilación de datos - para la recopilación de datos que caracteriza la pérdida auditiva previa, como el tiempo de privación auditiva y el comienzo del uso de CI -, audiometria e nel campo libre con CI a 250 a 4000 Hz frecuencias de sonido y El reconocimiento de voz se evaluó mediante la prueba "Lista de oraciones em portugués" - LSP aplicado em la condición favorable (silencio) y em la condición desfavorable (ruido) de la escucha. Em el análisis estadístico, se utilizaron coeficientes de correlación lineal de Pearson y gráficos de dispersión bidimensionales, además, um análisis descriptivo de los datos. Resultados: No hubo una relación estadísticamente significativa entre la privación auditiva y la percepción del habla en silencio y ruido. Por otro lado, hubo una correlación positiva estadísticamente significativa entre el tiempo de uso del implante coclear y el rendimento em la prueba de reconocimiento de oraciones en silencio. Conclusión: Hubo una correlación significativa solo entre el tiempo de uso del implante y el reconocimiento de oraciones en silencio em usuarios de implantes com sordera poslingual.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Implantes Cocleares , Surdez , Avaliação da Deficiência , Privação Sensorial , Fatores de Tempo , Perda Auditiva Bilateral , Testes Auditivos/métodos
5.
Rev. Soc. Bras. Med. Trop ; Rev. Soc. Bras. Med. Trop;50(5): 666-669, Sept.-Oct. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-1041430

RESUMO

Abstract INTRODUCTION: The objective was to identify comorbidities related to HIV-positive patients in Blumenau, State of Santa Catarina. METHODS: A retrospective, descriptive observational design study which analyzed data from 424 patients assisted by the sexually transmitted disease/acquired immunodeficiency syndrome (STD/AIDS) Specialized Care Service (SCS). RESULTS: Of 424 medical records analyzed, 388 patients presented CD4+/CD8+ ratios lower than 1. The most prevalent comorbidities were smoking, depression, alcoholism, and herpes zoster infection, in males and females. CONCLUSIONS: The most relevant comorbidity in both genders was herpes zoster, an important marker of immunity in patients. The lowest mean was observed among patients with neurotoxoplasmosis.


Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Síndrome da Imunodeficiência Adquirida/sangue , Síndrome da Imunodeficiência Adquirida/epidemiologia , Relação CD4-CD8/estatística & dados numéricos , Valores de Referência , Brasil/epidemiologia , Fumar/sangue , Fumar/epidemiologia , Comorbidade , Prevalência , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Depressão/sangue , Depressão/epidemiologia , Alcoolismo/sangue , Alcoolismo/epidemiologia , Herpes Zoster/sangue , Herpes Zoster/epidemiologia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa