Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36616793

RESUMO

Power-quality events and operation transients in power systems (PS) with isolated neutral can saturate inductive voltage transformers (IVT), which, when interacting with the overhead and underground cable capacitances, can cause ferroresonance events in the local PS. This abnormal operating mode can partially or totally damage the transformers and switchgears within the affected PS. Distribution system operators (DSO) can minimize these effects by detecting ferroresonance events accurately and fast enough and changing the mode of operation accordingly. Direct detection methods, i.e., based on voltage measurements, are reliable, but the massive deployment of this solution is relatively expensive; i.e., power quality analyzers cost thousands of USD. Alternatively, indirect detection methods are also available, e.g., IVT vibration measurements with accelerometers costing hundreds of USD, but their reliability depends on the installation method used. This manuscript proposes using the acoustic noise caused by magnetostriction forces within the IVT core during ferroresonance events to detect their occurrence. Compared to other indirect methods, electret condenser microphones with preamplifying stage cost less than USD 10 and are less sensitive to the installation procedure. The proposed method is validated experimentally, and its performance compared to IVT vibration measurements one by using the same detection methodology.

2.
Sensors (Basel) ; 20(24)2020 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-33322660

RESUMO

Efficiency in power lines operation is becoming more crucial as the electrification increases and more renewable energies are connected into the grid. New methods and sensors are being added to create smart grids to face these challenges and conductor temperature sensors are one of them. Contact temperature sensors have several problems regarding safety and electronic damage due to the electromagnetic fields induced on the conductors. The goal of this paper is to describe an infrared temperature measurement sensor and to compare contact and non-contact temperature measurements to estimate the temperature of power lines. Measurements were done for almost a year, storing around 150,000 measures of contact and infrared thermometers for many different weather and load conditions. The results conclude that the infrared system can be successfully used to control the temperature of the overhead conductor within a range of less than 4 ∘C difference with respect to contact temperature methods for the 88% of the samples and less than 6 ∘C for the 99%.

3.
Sensors (Basel) ; 19(19)2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31546981

RESUMO

Power transformers are the most important assets of electric power substations. The reliability in the operation of electric power transmission and distribution is due to the correct operation and maintenance of power transformers. The parameters that are most used to assess the health status of power transformers are dissolved gas analysis (DGA), oil quality analysis (OQA) and content of furfuraldehydes (FFA) in oil. The parameter that currently allows for simple online monitoring in an energized transformer is the DGA. Although most of the DGA continues to be done in the laboratory, the trend is online DGA monitoring, since it allows for detection or diagnosis of the faults throughout the life of the power transformers. This study presents a review of the main DGA monitors, single- or multi-gas, their most important specifications, accuracy, repeatability and measurement range, the types of installation, valve or closed loop, and number of analogue inputs and outputs. This review shows the differences between the main existing DGA monitors and aims to help in the selection of the most suitable DGA monitoring approach according to the needs of each case.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa