Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Clin Invest ; 54(4): e14139, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38063028

RESUMO

BACKGROUND: Technological progress in the acquisition of medical images and the extraction of underlying quantitative imaging data has introduced exciting prospects for the diagnostic assessment of a wide range of conditions. This study aims to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for classifying pulmonary embolism (PE) severity and assessing the risk for early death. METHODS: Patients who underwent CT pulmonary angiogram (CTPA) between January 2015 and March 2022 were considered for inclusion in this study. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models. RESULTS: The trained machine learning classifier achieved a classification accuracy of .90 for identifying high-risk PE patients with an area under the receiver operating characteristic curve of .59. This CT-based radiomics signature showed good diagnostic accuracy for risk stratification in individuals presenting with central PE, particularly within higher risk groups. CONCLUSION: Models utilizing DECT-derived radiomics features can accurately stratify patients with pulmonary embolism into established clinical risk scores. This approach holds the potential to enhance patient management and optimize patient flow by assisting in the clinical decision-making process. It also offers the advantage of saving time and resources by leveraging existing imaging to eliminate the necessity for manual clinical scoring.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Radiômica , Reprodutibilidade dos Testes , Embolia Pulmonar/diagnóstico por imagem , Medição de Risco , Estudos Retrospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38762707

RESUMO

An accurate diagnosis of venous thromboembolism (VTE) is crucial, given the potential for high mortality in undetected cases. Strategic D-dimer testing may aid in identifying low-risk patients, preventing overdiagnosis and reducing imaging costs. We conducted a retrospective, comparative analysis to assess the potential cost savings that could be achieved by adopting different approaches to determine the most effective D-dimer cut-off value in cancer patients with suspected VTE, compared to the commonly used rule-out cut-off level of 0.5 mg/L. The study included 526 patients (median age 65, IQR 55-75) with a confirmed cancer diagnosis who underwent D-dimer testing. Among these patients, the VTE prevalence was 29% (n = 152). Each diagnostic strategy's sensitivity, specificity, negative likelihood ratio (NLR), as well as positive likelihood ratio (PLR), and the proportion of patients exhibiting a negative D-dimer test result, were calculated. The diagnostic strategy that demonstrated the best balance between specificity, sensitivity, NLR, and PLR, utilized an inverse age-specific cut-off level for D-dimer [0.5 + (66-age) × 0.01 mg/L]. This method yielded a PLR of 2.9 at a very low NLR for the exclusion of VTE. We observed a significant cost reduction of 4.6% and 1.0% for PE and DVT, respectively. The utilization of an age-adjusted cut-off [patient's age × 0.01 mg/L] resulted in the highest cost savings, reaching 8.1% for PE and 3.4% for DVT. Using specified D-dimer cut-offs in the diagnosis of VTE could improve economics, considering the limited occurrence of confirmed cases among patients with suspected VTE.

3.
J Comput Assist Tomogr ; 48(2): 323-333, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38013237

RESUMO

OBJECTIVE: Our study objective was to explore the additional value of dual-energy CT (DECT) material decomposition for squamous cell carcinoma of the head and neck (SCCHN) survival prognostication. METHODS: A group of 50 SCCHN patients (male, 37; female, 13; mean age, 63.6 ± 10.82 years) with baseline head and neck DECT between September 2014 and August 2020 were retrospectively included. Primary tumors were segmented, radiomics features were extracted, and DECT material decomposition was performed. We used independent train and validation datasets with cross-validation and 100 independent iterations to identify prognostic signatures applying elastic net (EN) and random survival forest (RSF). Features were ranked and intercorrelated according to their prognostic importance. We benchmarked the models against clinical parameters. Intraclass correlation coefficients were used to analyze the interreader variation. RESULTS: The exclusively radiomics-trained models achieved similar ( P = 0.947) prognostic performance of area under the curve (AUC) = 0.784 (95% confidence interval [CI], 0.775-0.812) (EN) and AUC = 0.785 (95% CI, 0.759-0.812) (RSF). The additional application of DECT material decomposition did not improve the model's performance (EN, P = 0.594; RSF, P = 0.198). In the clinical benchmark, the top averaged AUC value of 0.643 (95% CI, 0.611-0.675) was inferior to the quantitative imaging-biomarker models ( P < 0.001). A combined imaging and clinical model did not improve the imaging-based models ( P > 0.101). Shape features revealed high prognostic importance. CONCLUSIONS: Radiomics AI applications may be used for SCCHN survival prognostication, but the spectral information of DECT material decomposition did not improve the model's performance in our preliminary investigation.


Assuntos
Neoplasias de Cabeça e Pescoço , Radiômica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem
4.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38523224

RESUMO

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado de Máquina , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Masculino , Feminino , Prognóstico , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Idoso , Biomarcadores/sangue , Valor Preditivo dos Testes , Estudos Retrospectivos
5.
Radiology ; 308(2): e223150, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37552067

RESUMO

Background In patients with distal radius fractures (DRFs), low bone mineral density (BMD) is associated with bone substitute use during surgery and bone nonunion, but BMD information is not regularly available. Purpose To evaluate the feasibility of dual-energy CT (DECT)-based BMD assessment from routine examinations in the distal radius and the relationship between the obtained BMD values, the occurrence of DRFs, bone nonunion, and use of surgical bone substitute. Materials and Methods Scans in patients who underwent routine dual-source DECT in the distal radius between January 2016 and December 2021 were retrospectively acquired. Phantomless BMD assessment was performed using the delineated trabecular bone of a nonfractured segment of the distal radius and both DECT image series. CT images and health records were examined to determine fracture severity, surgical management, and the occurrence of bone nonunion. Associations of BMD with the occurrence of DRFs, bone nonunion, and bone substitute use at surgical treatment were examined with generalized additive models and receiver operating characteristic analysis. Results This study included 263 patients (median age, 52 years; IQR, 36-64 years; 132 female patients), of whom 192 were diagnosed with fractures. Mean volumetric BMD was lower in patients who sustained a DRF (93.9 mg/cm3 vs 135.4 mg/cm3; P < .001), required bone substitutes (79.6 mg/cm3 vs 95.5 mg/cm3; P < .001), and developed bone nonunion (71.1 mg/cm3 vs 96.5 mg/cm3; P < .001). Receiver operating characteristic curve analysis identified these patients with an area under the curve of 0.71-0.91 (P < .001). Lower BMD increased the risk to sustain DRFs, develop bone nonunion, and receive bone substitutes at surgery (P < .001). Conclusion DECT-based BMD assessment at routine examinations is feasible and could help predict surgical bone substitute use and the occurrence of bone nonunion in patients with DRFs. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Carrino in this issue.


Assuntos
Substitutos Ósseos , Fraturas Ósseas , Fraturas do Punho , Humanos , Feminino , Pessoa de Meia-Idade , Densidade Óssea , Rádio (Anatomia)/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton
6.
NMR Biomed ; 36(2): e4828, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36082477

RESUMO

Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (Ï° = 0.96 [95% CI 0.88-1.00]) and conventional scans (Ï° = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Imagem Corporal Total , Fluxo de Trabalho
7.
Eur J Clin Invest ; 53(12): e14075, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37571983

RESUMO

BACKGROUND: To investigate the potential of radiomic features and dual-source dual-energy CT (DECT) parameters in differentiating between benign and malignant mediastinal masses and predicting patient outcomes. METHODS: In this retrospective study, we analysed data from 90 patients (38 females, mean age 51 ± 25 years) with confirmed mediastinal masses who underwent contrast-enhanced DECT. Attenuation, radiomic features and DECT-derived imaging parameters were evaluated by two experienced readers. We performed analysis of variance (ANOVA) and Chi-square statistic tests for data comparison. Receiver operating characteristic curve analysis and Cox regression tests were used to differentiate between mediastinal masses. RESULTS: Of the 90 mediastinal masses, 49 (54%) were benign, including cases of thymic hyperplasia/thymic rebound (n = 10), mediastinitis (n = 16) and thymoma (n = 23). The remaining 41 (46%) lesions were classified as malignant, consisting of lymphoma (n = 28), mediastinal tumour (n = 4) and thymic carcinoma (n = 9). Significant differences were observed between benign and malignant mediastinal masses in all DECT-derived parameters (p ≤ .001) and 38 radiomic features (p ≤ .044) obtained from contrast-enhanced DECT. The combination of these methods achieved an area under the curve of .98 (95% CI, .893-1.000; p < .001) to differentiate between benign and malignant masses, with 100% sensitivity and 91% specificity. Throughout a follow-up of 1800 days, a multiparametric model incorporating radiomic features, DECT parameters and gender showed promising prognostic power in predicting all-cause mortality (c-index = .8 [95% CI, .702-.890], p < .001). CONCLUSIONS: A multiparametric approach combining radiomic features and DECT-derived imaging biomarkers allows for accurate and noninvasive differentiation between benign and malignant masses in the anterior mediastinum.


Assuntos
Linfoma , Neoplasias do Mediastino , Neoplasias do Timo , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Linfoma/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico por imagem
8.
Eur J Clin Invest ; 53(4): e13914, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36444723

RESUMO

BACKGROUND: D-dimer testing is known to have a high sensitivity at simultaneously low specificity, resulting in nonspecific elevations in a variety of conditions. METHODS: This retrospective study sought to assess diagnostic and prognostic features of D-dimers in cancer patients referred to the emergency department for suspected pulmonary embolism (PE) and deep vein thrombosis (DVT). In total, 526 patients with a final adjudicated diagnosis of PE (n = 83) and DVT (n = 69) were enrolled, whereas 374 patients served as the comparative group, in which venous thromboembolism (VTE) has been excluded. RESULTS: For the identification of VTE, D-dimers yielded the highest positive predictive value of 96% (95% confidence interval (CI), 85-99) at concentrations of 9.9 mg/L and a negative predictive value of 100% at .6 mg/L (95% CI, 97-100). At the established rule-out cut-off level of .5 mg/L, D-dimers were found to be very sensitive (100%) at a moderate specificity of nearly 65%. Using an optimised cut-off value of 4.9 mg/L increased the specificity to 95% for the detection of life-threatening VTE at the cost of moderate sensitivities (64%). During a median follow-up of 30 months, D-dimers positively correlated with the reoccurrence of VTE (p = .0299) and mortality in both cancer patients with VTE (p < .0001) and without VTE (p = .0008). CONCLUSIONS: Although D-dimer testing in cancer patients is discouraged by current guidelines, very high concentrations above the 10-fold upper reference limit contain diagnostic and prognostic information and might be helpful in risk assessment, while low concentrations remain useful for ruling out VTE.


Assuntos
Neoplasias , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/diagnóstico , Prognóstico , Estudos Retrospectivos , Produtos de Degradação da Fibrina e do Fibrinogênio , Valor Preditivo dos Testes
9.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37409393

RESUMO

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio , Neoplasias , Humanos , Neoplasias/sangue , Neoplasias/complicações , Neoplasias/diagnóstico , Valor Preditivo dos Testes , Fatores de Risco , Tromboembolia Venosa/sangue , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevenção & controle , Bioensaio/normas , Sensibilidade e Especificidade
10.
Eur Radiol ; 33(9): 6339-6350, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37000215

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the diagnostic accuracy of third-generation dual-source dual-energy CT (DECT) color-coded collagen reconstructions for the assessment of the cruciate ligaments compared to standard grayscale image reconstruction. METHODS: Patients who underwent third-generation dual-source DECT followed by either 3-T MRI or arthroscopy of the knee joint within 14 days between January 2016 and December 2021 were included in this retrospective study. Five radiologists independently evaluated conventional grayscale DECT for the presence of injury to the cruciate ligaments; after 4 weeks, readers re-evaluated the examinations using grayscale images and color-coded collagen reconstructions. A reference standard for MRI was provided by a consensus reading of two experienced readers and arthroscopy. Sensitivity and specificity were the primary metrics of diagnostic performance. RESULTS: Eighty-five patients (mean age, 44 years ± 16; 50 male) with injury to the ACL or PCL (n = 31) were ultimately included. Color-coded collagen reconstructions significantly increased overall sensitivity (94/105 [90%] vs. 67/105 [64%]), specificity (248/320 [78%] vs. 215/320 [67%]), PPV (94/166 [57%] vs. 67/162 [39%]), NPV (248/259 [96%] vs. 215/253 [85%]), and accuracy (342/425 [81%] vs. 282/425 [66%]) for the detection of injury to the anterior cruciate ligament (all parameters, p < .001). For injury to the posterior cruciate ligament, diagnostic accuracy increased for complete tears (p < .001). Color-coded collagen reconstructions achieved superior diagnostic confidence, image quality, and noise scores compared to grayscale CT (all parameters, p < .001) and showed good agreement with MRI examinations. CONCLUSIONS: DECT-derived color-coded collagen reconstructions yield substantially higher diagnostic accuracy and confidence for assessing the integrity of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. KEY POINTS: • Color-coded collagen reconstructions derived from dual-energy CT yield substantially higher diagnostic accuracy and confidence for the assessment of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. • Color-coded collagen reconstructions demonstrate good agreement with MRI for the assessment cruciate ligament injury. • Dual-energy CT may serve as a readily available screening approach for patients with acute trauma to the knee when injury to the cruciate ligaments is suspected.


Assuntos
Lesões do Ligamento Cruzado Anterior , Tomografia Computadorizada por Raios X , Humanos , Masculino , Adulto , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho , Ligamento Cruzado Anterior , Colágeno , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos
11.
BMC Med Imaging ; 23(1): 71, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268876

RESUMO

BACKGROUND: Treatment plans for squamous cell carcinoma of the head and neck (SCCHN) are individually decided in tumor board meetings but some treatment decision-steps lack objective prognostic estimates. Our purpose was to explore the potential of radiomics for SCCHN therapy-specific survival prognostication and to increase the models' interpretability by ranking the features based on their predictive importance. METHODS: We included 157 SCCHN patients (male, 119; female, 38; mean age, 64.39 ± 10.71 years) with baseline head and neck CT between 09/2014 and 08/2020 in this retrospective study. Patients were stratified according to their treatment. Using independent training and test datasets with cross-validation and 100 iterations, we identified, ranked and inter-correlated prognostic signatures using elastic net (EN) and random survival forest (RSF). We benchmarked the models against clinical parameters. Inter-reader variation was analyzed using intraclass-correlation coefficients (ICC). RESULTS: EN and RSF achieved top prognostication performances of AUC = 0.795 (95% CI 0.767-0.822) and AUC = 0.811 (95% CI 0.782-0.839). RSF prognostication slightly outperformed the EN for the complete (ΔAUC 0.035, p = 0.002) and radiochemotherapy (ΔAUC 0.092, p < 0.001) cohort. RSF was superior to most clinical benchmarking (p ≤ 0.006). The inter-reader correlation was moderate or high for all features classes (ICC ≥ 0.77 (± 0.19)). Shape features had the highest prognostic importance, followed by texture features. CONCLUSIONS: EN and RSF built on radiomics features may be used for survival prognostication. The prognostically leading features may vary between treatment subgroups. This warrants further validation to potentially aid clinical treatment decision making in the future.


Assuntos
Neoplasias de Cabeça e Pescoço , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Estudos Retrospectivos , Prognóstico , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia
12.
J Appl Clin Med Phys ; 24(2): e13860, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36565180

RESUMO

This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95-23.01) to 2.36 µSv (IQR, 0.52-12.66) (-36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 µSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 µSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (-30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação , Humanos , Doses de Radiação , Estudos Prospectivos , Retroalimentação Sensorial , Radiometria , Lesões por Radiação/prevenção & controle , Exposição à Radiação/prevenção & controle , Exposição Ocupacional/prevenção & controle , Radiografia Intervencionista , Fluoroscopia
13.
Eur Radiol ; 32(1): 561-571, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34215940

RESUMO

OBJECTIVES: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. METHODS: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. RESULTS: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0-3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0-3) (p < .001). A cutoff value of - 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. CONCLUSIONS: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines. KEY POINTS: • In the setting of spinal trauma, dual-energy CT (DECT) is highly accurate in the evaluation of acute vertebral fractures and bone marrow edema presence and extent. • MRI provides moderate sensitivity and lower diagnostic confidence for the depiction of acute fracture lines, when compared to DECT, which might result in potentially inaccurate and underestimated severity assessment of injuries in certain cases when no fracture lines are visible on MRI. • DECT may represent a valid imaging alternative to MRI in specific settings of acute spinal trauma and in follow-up examinations, especially in elderly or unstable patients and in cases of subtle or complex orientated fracture lines.


Assuntos
Fraturas da Coluna Vertebral , Idoso , Medula Óssea , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
14.
Eur Radiol ; 32(5): 3076-3084, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34713330

RESUMO

OBJECTIVES: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. METHODS: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19-103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. RESULTS: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091-0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867-0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. CONCLUSIONS: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. KEY POINTS: •Dual-energy CT-derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).


Assuntos
Osteoporose , Fraturas por Osteoporose , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Osteoporose/epidemiologia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
15.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820684

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Assuntos
Deslocamento do Disco Intervertebral , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Medula Óssea , Edema , Feminino , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
16.
Acta Radiol ; 63(3): 328-335, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33657848

RESUMO

BACKGROUND: High-resolution computed tomography (HRCT) is essential in narrowing the possible differential diagnoses of diffuse and interstitial lung diseases. PURPOSE: To investigate the value of a novel computer-based decision support system (CDSS) for facilitating diagnosis of diffuse lung diseases at HRCT. MATERIAL AND METHODS: A CDSS was developed that includes about 100 different illustrations of the most common HRCT signs and patterns and describes the corresponding pathologies in detail. The logical set-up of the software facilitates a structured evaluation. By selecting one or more CT patterns, the program generates a ranked list of the most likely differential diagnoses. Three independent and blinded radiology residents initially evaluated 40 cases with different lung diseases alone; after at least 12 weeks, observers re-evaluated all cases using the CDSS. RESULTS: In 40 patients, a total of 113 HRCT patterns were evaluated. The percentage of correctly classified patterns was higher with CDSS (96.8%) compared to assessment without CDSS (90.3%; P < 0.01). Moreover, the percentage of correct diagnosis (81.7% vs. 64.2%) and differential diagnoses (89.2% vs. 38.3%) were superior with CDSS compared to evaluation without CDSS (both P < 0.01). CONCLUSION: Addition of a CDSS using a structured approach providing explanations of typical HRCT patterns and graphical illustrations significantly improved the performance of trainees in characterizing and correctly identifying diffuse lung diseases.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
17.
J Clin Ultrasound ; 50(9): 1414-1431, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36069404

RESUMO

Artificial intelligence is rapidly expanding in all technological fields. The medical field, and especially diagnostic imaging, has been showing the highest developmental potential. Artificial intelligence aims at human intelligence simulation through the management of complex problems. This review describes the technical background of artificial intelligence, machine learning, and deep learning. The first section illustrates the general potential of artificial intelligence applications in the context of request management, data acquisition, image reconstruction, archiving, and communication systems. In the second section, the prospective of dedicated tools for segmentation, lesion detection, automatic diagnosis, and classification of musculoskeletal disorders is discussed.


Assuntos
Aprendizado Profundo , Sistema Musculoesquelético , Humanos , Inteligência Artificial , Aprendizado de Máquina , Processamento de Imagem Assistida por Computador , Sistema Musculoesquelético/diagnóstico por imagem
18.
Eur Radiol ; 31(6): 4071-4078, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33277670

RESUMO

OBJECTIVES: To evaluate the performance of radiomic features extracted from high-resolution computed tomography (HRCT) for the differentiation between cholesteatoma and middle ear inflammation (MEI), and to investigate the impact of post-reconstruction harmonization and data resampling. METHODS: One hundred patients were included in this retrospective dual-center study: 48 with histology-proven cholesteatoma (center A: 23; center B: 25) and 52 with MEI (A: 27; B: 25). Radiomic features (co-occurrence and run-length matrix, absolute gradient, autoregressive model, Haar wavelet transform) were extracted from manually defined 2D-ROIs. The ten best features for lesion differentiation were selected using probability of error and average correlation coefficients. A multi-layer perceptron feed-forward artificial neural network (MLP-ANN) was used for radiomics-based classification, with histopathology serving as the reference standard (70% of cases for training, 30% for validation). The analysis was performed five times each on (a) unmodified data and on data that were (b) resampled to the same matrix size, and (c) corrected for acquisition protocol differences using ComBat harmonization. RESULTS: Using unmodified data, the MLP-ANN classification yielded an overall median area under the receiver operating characteristic curve (AUC) of 0.78 (0.72-0.84). Using original data from center A and resampled data from center B, an overall median AUC of 0.88 (0.82-0.99) was yielded, while using ComBat harmonized data, an overall median AUC of 0.89 (0.79-0.92) was revealed. CONCLUSION: Radiomic features extracted from HRCT differentiate between cholesteatoma and MEI. When using multi-centric data obtained with differences in CT acquisition parameters, data resampling and ComBat post-reconstruction harmonization clearly improve radiomics-based lesion classification. KEY POINTS: • Unenhanced high-resolution CT coupled with radiomics analysis may be useful for the differentiation between cholesteatoma and middle ear inflammation. • Pooling of data extracted from inhomogeneous CT datasets does not appear meaningful without further post-processing. • When using multi-centric CT data obtained with differences in acquisition parameters, post-reconstruction harmonization and data resampling clearly improve radiomics-based soft-tissue differentiation.


Assuntos
Colesteatoma , Otite Média , Humanos , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
Eur Radiol ; 31(7): 4428-4437, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409799

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded dual-energy CT virtual non-calcium (VNCa) reconstructions for the assessment of bone marrow edema (BME) of the scaphoid in patients with acute wrist trauma. METHODS: Our retrospective study included data from 141 patients (67 women, 74 men; mean age 43 years, range 19-80 years) with acute wrist trauma who had undergone third-generation dual-source dual-energy CT and 3-T MRI within 7 days. Eight weeks after assessment of conventional grayscale dual-energy CT scans for the presence of fractures, corresponding color-coded VNCa reconstructions were independently analyzed by the same six radiologists for the presence of BME. CT numbers on VNCa reconstructions were evaluated by a seventh radiologist. Consensus reading of MRI series by two additional radiologists served as the reference standard. RESULTS: MRI depicted 103 scaphoideal zones with BME in 76 patients. On qualitative analysis, VNCa images yielded high overall sensitivity (580/618 [94%]), specificity (1880/1920 [98%]), and accuracy (2460/2538 [97%]) for assessing BME as compared with MRI as reference standard. The interobserver agreement was excellent (κ = 0.98). CT numbers derived from VNCa images were significantly different in zones with and without edema (p < 0.001). A cutoff value of - 46 Hounsfield units provided a sensitivity of 91% and specificity of 97% for differentiating edematous scaphoid lesions. Receiver operating characteristic curve analysis revealed an overall area under the curve of 0.98. CONCLUSIONS: Qualitative and quantitative analyses showed excellent diagnostic accuracy of color-coded VNCa reconstructions for assessing traumatic BME of the scaphoid compared to MRI. KEY POINTS: • Color-coded virtual non-calcium (VNCa) reconstructions yield excellent diagnostic accuracy in assessing bone marrow edema of the scaphoid. • VNCa imaging enables detection of non-displaced fractures that are occult on standard grayscale CT. • Diagnostic confidence is comparable between VNCa imaging and MRI.


Assuntos
Medula Óssea , Osso Escafoide , Adulto , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Cálcio , Edema/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Escafoide/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Adulto Jovem
20.
Eur Radiol ; 31(12): 9221-9231, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34076743

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. METHODS: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. RESULTS: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89-0.96] vs 485/665 [73%; 95% CI, 0.67-0.80]), specificity (4775/4990 [96%; 95% CI, 0.90-0.98] vs 4066/4990 [82%; 95% CI, 0.79-0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93-0.98] vs 4551/5655 [81%; 95% CI, 0.74-0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). CONCLUSIONS: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT. KEY POINTS: • Color-coded VNCa reconstructions derived from third-generation dual-source dual-energy CT yielded significantly higher diagnostic accuracy for the assessment of thoracic disk herniation and spinal nerve root impingement compared to standard grayscale CT. • VNCa imaging provided higher diagnostic confidence and image quality at lower noise levels compared to standard grayscale CT. • Color-coded VNCa images may potentially serve as a viable imaging alternative to MRI under circumstances where MRI is unavailable or contraindicated.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Idoso , Medula Óssea , Edema , Feminino , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa