Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 245: 100-109, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34932999

RESUMO

BACKGROUND: Tricuspid valve disease (TVD) is presumed common, however, little is known about its prevalence or the impact of tricuspid valve surgery (TVS) on healthcare resource use. METHODS: To describe the prevalence of TVD and assess the impact of TVS on resource utilization, Medicare Fee-For-Service beneficiaries from 2011 -2019 were assessed for the prevalence of non-rheumatic TVD. Hospital costs and rates of all-cause, cardiovascular (CV), and heart failure (HF) hospitalizations were compared in the 3 months pre TVS to acute (0-3 months) and chronic (3 -12 months) post TVS periods. RESULTS: Among 80.3 million beneficiaries from 2011 - 2019 Q1, over 700,000 (0.9%) had non-rheumatic TVD with 1.4% undergoing TVS. Thirty-day and 1 year mortality after TVS was 5.5% to15.5%. Compared with pre-surgery, CV and HF hospitalizations decreased from 0.12 to 0.08 per patient-month (P <.001), and 0.06 to 0.04 (P <.001) acutely. All-cause hospitalizations increased from 0.18 per patient-month to 0.23 per patient-month acutely post-surgery (P <.001), before decreasing to 0.09 per patient-month chronically (P <.001). Hospital costs increased from $2,174 per patient-month to $4,171 per patient-month acutely (P < .001), before falling to $1,441 per patient-month (P < .001) chronically. Lower costs for HF and CV hospitalization in both acute (P = .028 and P < .001, respectively) and chronic (P < .001 for both) periods were observed. CONCLUSIONS: TVS is associated with reduced CV and HF hospitalizations and associated hospital costs. Future work should determine whether transcatheter tricuspid valve repair offers similar or additional benefits.


Assuntos
Doenças das Valvas Cardíacas , Valva Tricúspide , Idoso , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia , Hospitais , Humanos , Medicare , Prevalência , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Estados Unidos/epidemiologia
2.
JAMA ; 319(1): 27-37, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29297076

RESUMO

Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur. Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR. Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017. Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305). Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set. Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%). Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Bioprótese , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 90(3): 526-529, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28295972

RESUMO

Transcatheter aortic valve replacement is standard of care for patients with severe aortic stenosis at high risk for surgical aortic valve replacement. Although not intended for treatment of primary aortic insufficiency, several transcatheter aortic valve prostheses have been used to treat patients with severe aortic insufficiency (AI), including patients with left ventricular assist devices (LVAD), in whom significant AI is not uncommon. Similarly, transcatheter valve replacements have been used for valve-in-valve treatment, in the pulmonary, aortic, and mitral positions, either via a retrograde femoral approach or antegrade transseptal approach (mitral valve-in-valve). In this case report, we report an LVAD patient with severe aortic insufficiency and severe bioprosthetic mitral prosthetic stenosis, in whom we successfully performed transfemoral aortic valve replacement and transfemoral mitral valve-in-valve replacement via a transseptal approach. © 2017 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Coração Auxiliar , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Função Ventricular Esquerda , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/fisiopatologia , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 88(3): E74-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26699241

RESUMO

OBJECTIVES: The aim of this study was to test the feasibility and value of a real-time online appropriate use criteria (AUC) application for percutaneous coronary intervention (PCI) in patients without acute coronary syndrome. BACKGROUND: High rates of non-appropriate elective PCI in the National Cardiovascular Data Registry (NCDR) CathPCI Registry have created interest in integrating decision support tools into routine clinical care to improve the frequency of appropriate PCIs. METHODS: Patients undergoing diagnostic coronary angiography and subsequent PCI for non-ACS indications at a single center were scored using a real-time AUC application pre-procedure. Blinded angiographic review was performed subsequently for each case. Rates of appropriate, inappropriate, uncertain and not rated PCIs were tabulated according to specific clinical scenarios using information available both before and after the angiographic audit. RESULTS: Of 308 PCIs in 272 patients, 196 (63.6%) were deemed appropriate, 79 (25.6%) uncertain, and two (0.6%) inappropriate; 31 (10.1%) scenarios could not be rated. With angiographic audit, inappropriate PCIs increased to 9.7%. There was a significant improvement in the rate of appropriate PCI using the real-time AUC application compared with retrospective data collection for NCDR reporting (64% vs. 53%, P = 0.01). CONCLUSIONS: Use of a real-time AUC application together with angiographic audit may improve the accuracy of reporting PCI appropriateness. © 2015 Wiley Periodicals, Inc.


Assuntos
Doença da Artéria Coronariana/terapia , Técnicas de Apoio para a Decisão , Seleção de Pacientes , Intervenção Coronária Percutânea , Procedimentos Desnecessários , Idoso , Boston , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Auditoria Médica , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 87(3): 363-73, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26011467

RESUMO

BACKGROUND: Outcomes with bivalirudin compare favorably with heparin ± GPIIb/IIIa receptor inhibition (heparin ± GPI) during percutaneous coronary intervention (PCI). Patients with congestive heart failure (CHF) have increased risk for complications. The objective was to investigate clinical and economic outcomes for bivalirudin ± GPI vs. heparin ± GPI among PCI patients with CHF. METHODS: Using the Premier Hospital Database, PCI patients with CHF were stratified by anticoagulant: bivalirudin, bivalirudin ± GPI, heparin and heparin ± GPI. The probability of receiving bivalirudin ± GPI was estimated using individual and hospital variables. Using propensity scores, each bivalirudin ± GPI patient was matched to a heparin ± GPI patient. The primary outcome was in-hospital death. Bleeding rates, transfusion, length of stay and in-hospital cost were ascertained. RESULTS: Overall, 116,313 patients at 315 hospitals received bivalirudin (n = 45,559) bivalirudin + GPI (n = 8,115), heparin (n = 27,972) or heparin + GPI (n = 34,667). Patients had STEMI (21.2%), NSTEMI (29.1%), unstable angina (16.6%), stable angina (5.7%) or other ischemic heart disease (24.2%). Of these, 79.1% of bivalirudin patients matched, resulting in 84,948 analyzed patients. Compared with heparin ± GPI patients, bivalirudin ± GPI patients had fewer deaths (3.3% vs. 3.9%; p < 0.0001), less clinically apparent bleeding (10.2% vs. 11.4%; p < 0.0001), clinically apparent bleeding with transfusion (2.7% vs. 3.2%, p <0.0001), and transfusion (8.5% vs. 9.8%, p < 0.0001). Patients receiving bivalirudin had shorter length of stay (6.3 vs. 6.8 days; p < 0.0001) and lower in-hospital cost (mean $26,706 vs. $27,166 [median $19,414 vs. $19,798]; p < 0.0001). In conclusion, this is the largest retrospective analysis of PCI patients with CHF and demonstrates bivalirudin ± GPI compared with heparin ± GPI is associated with lower inpatient rates of death, bleeding, and cost.


Assuntos
Antitrombinas/economia , Antitrombinas/uso terapêutico , Custos de Medicamentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/economia , Hirudinas/economia , Custos Hospitalares , Fragmentos de Peptídeos/economia , Fragmentos de Peptídeos/uso terapêutico , Intervenção Coronária Percutânea/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/economia , Anticoagulantes/uso terapêutico , Antitrombinas/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue/economia , Análise Custo-Benefício , Bases de Dados Factuais , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Heparina/economia , Heparina/uso terapêutico , Hirudinas/efeitos adversos , Mortalidade Hospitalar , Humanos , Tempo de Internação/economia , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/economia , Inibidores da Agregação Plaquetária/uso terapêutico , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/economia , Proteínas Recombinantes/uso terapêutico , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Adulto Jovem
6.
JACC Case Rep ; 29(3): 102192, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38361571

RESUMO

Misloading during transcatheter aortic valve replacement (TAVR) is rare but can cause unpredictable valve release if unrecognized. We describe how to identify a misloaded ACURATE neo2 device, and 3 methods to solve this by using a modified technique of valve deployment, ipsilateral extraction, and contralateral valve externalization with extracorporeal valve release.

7.
Struct Heart ; 8(3): 100277, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799801

RESUMO

Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.

8.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38244892

RESUMO

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Cálcio , Resultado do Tratamento , Estudos Retrospectivos , Desenho de Prótese
9.
JACC Case Rep ; 11: 101777, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37077443

RESUMO

An 80-year-old man with a supra-annular transcatheter aortic valve (TAV) prosthesis presented with severe transvalvular aortic regurgitation 18 months after the TAV replacement procedure. The authors report the first ever valve-in-valve procedure using BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) in such a supra-annular TAV prosthesis. Minimal paravalvular leakage, normal coronary artery flow, and easy coronary access were seen postimplantation. (Level of Difficulty: Advanced.).

10.
Int J Cardiol ; 377: 26-32, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36640966

RESUMO

BACKGROUND: Cardiac tamponade caused by temporary right ventricular (RV) pacemaker perforation is a rare but serious complication in transcatheter aortic valve replacement (TAVR). AIMS: To study the incidence of temporary pacemaker related cardiac tamponade in TAVR, and the relation to the type of pacemaker lead used in periprocedural temporary transvenous pacing. METHODS: A single center registry of transfemoral TAVRs in 2014-2020. Main inclusion criterion was peri-operative use of a temporary RV pacing lead. Main exclusion criteria were a preoperatively implanted permanent pacemaker or the exclusive use of left ventricular guidewire pacing. Incident cardiac tamponade was classified as pacemaker lead related, or other. Patients were grouped according to type of temporary RV pacing wire. RESULTS: 810 patients were included (age 80.5 ± 7.3 [mean ± standard deviation], female 319, 39.4%). Of these, 566 (69.9%) received a standard RV temporary pacing wire (RV-TPW), and 244 (30.1%) received temporary RV pacing through a permanent, passive pacemaker lead (RV-TPPL). In total, 18 (2.2%) events of cardiac tamponade occurred, 12 (67%) were pacemaker lead related. All pacemaker lead-related cardiac tamponades occurred in the group who received a standard RV-TPW and none in the group who received RV-TPPL (n = 12 [2.1%] vs. n = 0 [0%], p = 0.022). No difference in cardiac tamponade due to other causes was seen between the groups (p = 0.82). CONCLUSIONS: The use of soft-tip RV-TPPL was associated with a lower risk of pacemaker related cardiac tamponade in TAVR. When perioperative pacing is indicated, temporary RV-TPPL may contribute to a significant reduction of cardiac tamponade in TAVR.


Assuntos
Estenose da Valva Aórtica , Tamponamento Cardíaco , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Valva Aórtica/cirurgia
11.
JACC Cardiovasc Interv ; 16(6): 670-677, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36990556

RESUMO

BACKGROUND: Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population. OBJECTIVES: The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve. METHODS: A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days. RESULTS: Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe. CONCLUSIONS: In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada Multidetectores
12.
JACC Heart Fail ; 11(8 Pt 2): 1121-1130, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37115132

RESUMO

BACKGROUND: Most approaches to the creation of an interatrial shunt require placement of a permanent implant to maintain patency. OBJECTIVES: The goal of this study was to investigate the safety and efficacy of a no-implant interatrial shunt for patients with heart failure with preserved ejection fraction (HFpEF) and heart failure with mildly reduced ejection fraction (HFmrEF). METHODS: This was a multicenter, uncontrolled study of patients with HFpEF/HFmrEF and NYHA functional class ≥II, ejection fraction >40%, and pulmonary capillary wedge pressure (PCWP) during supine exercise ≥25 mm Hg with PCWP-to-right atrial gradient ≥5 mm Hg. Follow-up was through 6 months with imaging to assess shunt durability. RESULTS: A total of 28 patients were enrolled: mean age was 68 ± 9 years, and 68% were female. Baseline resting and peak exercise PCWP were 19 ± 7 mm Hg and 40 ± 11 mm Hg, respectively. All procedures displayed technical success with confirmation of left-to-right flow (shunt diameter 7.1 ± 0.9 mm). At 1 month, peak exercise PCWP decreased 5.4 ± 9.6 mm Hg (P = 0.011) with no change in right atrial pressure. There were no serious device or procedure-related adverse events through 6 months. Mean 6-minute walk distance increased 101 ± 71 meters (P < 0.001); Kansas City Cardiomyopathy Questionnaire Overall Summary Score increased 26 ± 19 points (P < 0.001); N-terminal pro-B-type natriuretic peptide decreased 372 ± 857 pg/mL (P = 0.018); and shunt patency was confirmed with unchanged diameter. CONCLUSIONS: In these feasibility studies of a no-implant interatrial shunt, HFpEF/HFmrEF shunts exhibited stability with favorable safety and early efficacy signals. The results show promise toward this new approach for treating patients with HFpEF/HFmrEF and an appropriate hemodynamic profile. (Evaluation of the Safety and Feasibility of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-1]; NCT04583527; Evaluation of the Safety and Effectiveness of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-2]; NCT04838353).


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Volume Sistólico , Função Ventricular Esquerda , Estudos de Viabilidade , Cateterismo Cardíaco , Disfunção Ventricular Esquerda/etiologia
13.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37489732

RESUMO

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia
14.
EuroIntervention ; 19(4): e352-e362, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37334801

RESUMO

BACKGROUND: TAVI is a widely accepted treatment for patients with severe aortic stenosis (AS). Despite the adoption of diverse therapies, opportunities remain to develop technologies tailored to provide optimal acute and potential long-term benefits, particularly around haemodynamics, flow and durability. AIMS: We aimed to evaluate the safety and feasibility of the DurAVR transcatheter heart valve (THV), a first-in-class biomimetic valve, in the treatment of patients with symptomatic severe AS. METHODS: This was a first-in-human (FIH), prospective, non-randomised, single-arm, single-centre study. Patients with severe, symptomatic AS of any surgical risk and who were eligible for the DurAVR THV prosthesis were recruited; they were assessed at baseline, 30 days, 6 months, and 1 year post-procedure for implant success, haemodynamic performance, and safety. RESULTS: Thirteen patients (73.9±6.4 years old, 77% female) were enrolled. The DurAVR THV was successfully implanted in 100% of cases with no device-related complications. One access site complication, one permanent pacemaker implantation, and one case of moderate aortic regurgitation occurred. Otherwise, no deaths, stroke, bleeding, reinterventions, or myocardial infarction were reported during any of the follow-up visits. Despite a mean annulus size of 22.95±1.09 mm, favourable haemodynamic results were observed at 30 days (effective orifice area [EOA] 2.00±0.17 cm2, and mean pressure gradient [MPG] 9.02±2.68 mmHg) and were sustained at 1 year (EOA 1.96±0.11 cm2, MPG 8.82±1.38 mmHg), resulting in zero patients with any degree of prosthesis-patient mismatch. Additionally, new valve performance measures derived from cardiovascular magnetic resonance displayed restoration of laminar flow, consistent with a predisease state, in conjunction with a mean coaptation length of 8.3±1.7 mm. CONCLUSIONS: Preliminary results from the FIH study with DurAVR THV demonstrate a good safety profile with promising haemodynamic performance sustained at 1 year and restoration of near-normal flow dynamics. Further clinical investigation is warranted to evaluate how DurAVR THV may play a role in addressing the challenge of lifetime management in AS patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Estudos de Viabilidade , Biomimética , Resultado do Tratamento , Desenho de Prótese
15.
Int J Cardiol ; 359: 7-13, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35427700

RESUMO

BACKGROUND: Arterial access-site related complications constitute a large proportion of adverse events related to cardiac interventions requiring large-bore devices and have significant implications on morbidity, mortality and hospital cost. AIMS: To evaluate the safety and effectiveness of a novel percutaneous plug-based vascular closure device (VCD) in 1000 consecutive patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). METHODS: A single-center observational study evaluating a plug-based VCD (MANTA, Teleflex/Essential Medical Inc., Malvern, Pennsylvania, USA) in patients undergoing TAVI at the Karolinska University Hospital, Stockholm, Sweden. The primary outcome was VCD-related major vascular complication according to the criteria of the Valve Academic Research Consortium (VARC)-2. RESULTS: From May 2017 to September 2020 a total of 1000 consecutive patients underwent transfemoral TAVI with arterial access-site management using the MANTA VCD. VARC-2 major vascular complications occurred in 42 (4.2%) patients: 17 (1.7%) patients intraoperatively received a covered stent, 17 (1.7%) patients underwent surgical repair during hospital stay, 3 (0.3%) patients underwent vascular surgery after discharge, 3 (0.3%) patients had major bleeding and 2 (0.2%) patients had symptoms of claudication with conservative treatment. No significant differences in major complications were seen between individual interventionists irrespective of experience with the device. A larger sheath outer diameter to femoral artery inner diameter ratio was the only factor associated with a significant increase of VCD-related major vascular complications. CONCLUSION: This largest ever real-world evaluation of MANTA for large-bore arteriotomy closure in transfemoral TAVI patients indicates effective and safe arterial access-site management with low complication rates and short learning curve. CLINICAL TRIAL REGISTRATION: http://www. CLINICALTRIALS: gov. Unique identifier: NCT04392492.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Artéria Femoral/cirurgia , Técnicas Hemostáticas , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
16.
Struct Heart ; 6(4): 100078, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37288335

RESUMO

Background: Heart failure with preserved ejection fraction represents a major unmet clinical need with limited treatment options. Recent device therapies under investigation have focused on decompression of the left atrium through an implantable interatrial shunt. Although these devices have shown favorable safety and efficacy signals, an implant is required to maintain shunt patency, which may increase the patient risk profile and complicate subsequent interventions requiring transseptal access. Methods: The Alleviant System is a no-implant approach to creating an interatrial shunt using radiofrequency energy to securely capture, excise, and extract a precise disk of tissue from the interatrial septum. Acute preclinical studies in healthy swine (n = 5) demonstrated the feasibility of the Alleviant System to repeatably create a 7 mm interatrial orifice with minimal collateral thermal effect and minimal platelet and fibrin deposition observed histologically. Results: Chronic animal studies (n = 9) were carried out to 30- and 60-day time points and exhibited sustained shunt patency with histology demonstrating completely healed margins, endothelialization, and no trauma to adjacent atrial tissue. Preliminary clinical safety and feasibility were validated in a first-in-human study in patients with heart failure with preserved ejection fraction (n = 15). All patients demonstrated shunt patency by transesophageal echocardiographic imaging at 1, 3, and 6 months, as well as cardiac computed tomography imaging at 6-month follow-up timepoints. Conclusions: Combined, these data support the safety and feasibility of a novel no-implant approach to creating an interatrial shunt using the Alleviant System. Continued follow-up and subsequent clinical studies are currently ongoing.

17.
J Clin Med ; 11(20)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36294424

RESUMO

(1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: -55.15, -36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = -0.642 (95%CrI of differences: -0.85, -0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = -7.29 (95% CrI: -14.45, -0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.

18.
J Invasive Cardiol ; 34(11): E776-E783, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36227011

RESUMO

OBJECTIVES: We aimed to develop and validate an effective prediction model for 1-year mortality risk in elective transfemoral transcatheter aortic valve replacement (TAVR), ie, the TAVR-Risk (TARI) model. BACKGROUND: TAVR is the primary treatment for patients with symptomatic severe aortic valve stenosis; however, risk assessment tools for longer-term outcomes after TAVR remain scarce. METHODS: This retrospective cohort study used logistic regression to test univariate and multivariate associations. The German Aortic Valve Registry (GARY) was the derivation (n = 20,704) and the Swedish SWEDEHEART TAVR Registry (SWENTRY) was the validation cohort (n = 3982). The main outcome was the area under the curve (AUC) in the prediction of 1-year mortality. The final model included 12 parameters that were associated with 1-year mortality in a multivariate analysis. RESULTS: The TARI model (AUC, 0.66; 95% confidence interval [CI] 0.65-0.67) performed better as compared with the Society of Thoracic Surgeons (STS) score (AUC, 0.63; 95% CI, 0.62-0.64; P<.001) and logistic EuroSCORE I (AUC, 0.60; 95% CI, 0.59-0.61; P<.001) in the GARY derivation cohort, and discriminated the risk for 1-year mortality better than logistic EuroSCORE I in the SWENTRY validation cohort (AUC, 0.62; 95% CI, 0.60-0.64 vs AUC, 0.59; 95% CI, 0.57-0.61; P=.04). CONCLUSIONS: This novel TARI score provides a relatively easy-to-use risk model and offers a superior prediction for 1-year mortality in European TAVR patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Medição de Risco , Resultado do Tratamento
19.
JACC Cardiovasc Imaging ; 14(1): 61-111, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32828782

RESUMO

Primary or secondary tricuspid regurgitation (TR) represents an important health care burden and challenge which has often been neglected or undertreated in the past. The expansion and reinforcement of the indications for tricuspid valve (TV) intervention in the 2017 editions of the guidelines as well as the introduction of transcatheter tricuspid valve intervention (TTVI) has considerably increased the attention of the community on the TV and the volume of TV interventions in the past years. Depending on the anatomic target, TTVI can be categorized as the following: 1) direct or indirect tricuspid restrictive annuloplasty; 2) direct (edge-to-edge repair) or indirect (coaptation device) restoration of leaflet coaptation; 3) heterotopic tricuspid valve implantation; and 4) transcatheter tricuspid valve replacement. Multimodality imaging has crucial role for the following: 1) patient selection for TTVI and procedure planning; 2) guiding and monitoring the procedure; and 3) assessing and following over time the results of the procedure. The key points for pre-procedural imaging are: 1) accurate quantitation of TR severity; 2) proper identification of the mechanism(s) responsible for the TR; and 3) quantitation of RV dysfunction and pulmonary arterial hypertension. This imaging work-up is essential to select the right type of intervention for the right patient and TV. Transesophageal echocardiography and fluoroscopy imaging is also key for guiding the TTVI procedures and fusion between these 2 modalities may further enhance the quality of procedure guiding.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
20.
J Clin Med ; 10(20)2021 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-34682750

RESUMO

The new-generation ACURATE neo2 system was commercially released in September 2020. In this study, we sought to compare the aortic regurgitation (AR) severity of the ACURATE neo2 versus the ACURATE neo transcatheter heart valve, using quantitative videodensitometric angiography (qAR). This is a retrospective, Corelab analysis of final post-transcatheter aortic valve implantation (TAVI) aortograms of patients treated with the ACURATE neo2 and ACURATE neo systems. The ACURATE neo2 cohort comprised consecutive patients treated between September 2020 and January 2021 at two centers. The ACURATE neo cohort included consecutive patients treated before September 2020. Our primary objective was to compare AR severity on qAR following TAVI with ACURATE neo2 and ACURATE neo. Out of 401 aortograms, 228 (56.9%) were analyzable, with 120 in the ACURATE neo2 cohort, and 108 in the ACURATE neo cohort. The mean AR fraction was 4.4 ± 4.8% in the neo2 cohort, and 9.9 ± 8.2% in the neo cohort (p < 0.001). Furthermore, moderate or severe AR (qAR > 17%) was detected in 2 aortograms (1.7%) in the neo2 cohort and 15 aortograms (13.9%) in the neo cohort (p < 0.001). Quantitative aortography shows a lower rate of moderate or severe paravalvular AR in what is the first European experience of the new-generation, self-expanding ACURATE neo2 when compared to the first-generation ACURATE neo. Moreover, aortographic data need to be correlated and compared to Core Laboratory-adjudicated 30-day echocardiographic data.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa