Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Fail ; 28(6): 963-972, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35041933

RESUMO

OBJECTIVE: Patients with heart failure (HF) are at an increased risk of hospital admissions. The aim of this report is to describe the feasibility, safety and accuracy of a novel wireless left atrial pressure (LAP) monitoring system in patients with HF. METHODS: The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) study is a prospective, multicenter, single-arm, open-label, first-in human clinical trial to assess the safety, performance and usability of the V-LAP system (Vectorious Medical Technologies) in patients with New York Heart Association class III HF. The device was implanted in the interatrial septum via a percutaneous, trans-septal approach guided by fluoroscopy and echocardiography. Primary endpoints included the successful deployment of the implant, the ability to perform initial pressure measurements and safety outcomes. RESULTS: To date, 24 patients have received implants of the LAP-monitoring device. No device-related complications have occurred. LAP was reported accurately, agreeing well with wedge pressure at 3 months (Lin concordance correlation coefficient = 0.850). After 6 months, New York Heart Association class improved in 40% of the patients (95% CI = 16.4%-63.5%), while the 6-minute walk test distance had not changed significantly (313.9 ± 144.9 vs 232.5 ± 129.9 meters; P = 0.076). CONCLUSION: The V-LAP left atrium monitoring system appears to be safe and accurate.


Assuntos
Pressão Atrial , Insuficiência Cardíaca , Cateterismo Cardíaco , Humanos , Estudos Prospectivos , Volume Sistólico
2.
Echocardiography ; 33(3): 450-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26412026

RESUMO

BACKGROUND: Myocardial ischemia causes contractile dysfunction in ischemic, stunned, and tethered regions with larger infarcted zones having a negative prognostic impact on patients' outcomes. To distinguish the infarcted myocardium from the other regions, we investigated the diagnostic potential of circumferential strain (CS) and radial strain (RS) during the acute and chronic stages of myocardial infarction. METHODS: Ten pigs underwent 90-minute occlusion of the left anterior descending artery, followed by reperfusion. Echocardiography was performed at baseline, after 90-minute occlusion, and at 2 hours, 30, and 60 days postreperfusion. CS and RS were measured using speckle tracking echocardiography. Subsequently, the pigs were sacrificed, and histological analysis for infarct size was performed. RESULTS: After 90-minute occlusion, reduced strains were detected for all segments (infarcted anterior wall - baseline: CS: -17.6 ± 5.7%, RS: 54.4 ± 16.9%; 90 min: CS: -10.3 ± 3.0%, RS: 23.3 ± 7.0%; tethered posterior wall - baseline: CS: -18.4 ± 3.5%, RS: 68.7 ± 21.1%; 90 min: CS: -10.7 ± 6.4%, RS: 34.5 ± 14.7%, P < 0.001). However, postsystolic shortening was detected only in the infarcted segments, and the time-to-peak CS was 25% longer (P < 0.05). At 30 and 60 days postreperfusion, time-to-peak CS could only detect large scars in the anterior and anterior-septum walls (P < 0.05), while peak CS also detected smaller scars in the lateral wall (P < 0.05). RS failed to distinguish between normal, stunned/tethered, and infarcted myocardium. CONCLUSIONS: During occlusion and 2 hours postreperfusion, time-to-peak CS could distinguish between infarcted and stunned/tethered myocardial segments, while at 30 and 60 days postreperfusion, peak CS was the best detector of infarction.


Assuntos
Progressão da Doença , Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Doença Aguda , Animais , Doença Crônica , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
3.
J Cardiovasc Pharmacol ; 66(2): 214-22, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25900266

RESUMO

BACKGROUND: The current cornerstone treatment of myocardial infarction (MI) is restoration of coronary blood flow by means of thrombolytic therapy or primary percutaneous coronary intervention. However, reperfusion of ischemic myocardium can actually provoke tissue damage, defined as "ischemia-reperfusion (I/R) injury." TVP1022 [the S-isomer of rasagiline (Azilect), FDA-approved anti-Parkinson's drug] was found to exert cardioprotective activities against various cardiac insults, such as chronic heart failure and I/R, in rat models. Therefore, we tested the hypothesis that TVP1022 will provide cardioprotection against I/R injury and post-MI remodeling in a pig model. METHODS: For inducing MI, we used an I/R model of midleft anterior descending artery occlusion for 90 minutes followed by follow-up for 8 weeks in 18 farm pigs (9 pigs in each group, MI + TVP1022 or MI + Vehicle). Echocardiographic measurements were performed and cardiac scar size was calculated using histopathological methods. For fibrosis evaluation, we measured the interstitial collagen volume fraction in the remote noninfarcted tissue. RESULTS: TVP1022 administration significantly decreased cardiac scar size, attenuated left ventricular dilation, and improved cardiac function assessed by segmental circumferential strain analysis. Furthermore, TVP1022 significantly reduced myocardial fibrosis 8 weeks post-MI. CONCLUSIONS: Collectively, these findings indicate that TVP1022 provides prominent cardioprotection against I/R injury and post-MI remodeling in this I/R pig model.


Assuntos
Cardiotônicos/uso terapêutico , Indanos/uso terapêutico , Infarto do Miocárdio/tratamento farmacológico , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Remodelação Ventricular/efeitos dos fármacos , Animais , Cardiotônicos/farmacologia , Indanos/farmacologia , Infarto do Miocárdio/patologia , Traumatismo por Reperfusão Miocárdica/patologia , Sus scrofa , Suínos , Remodelação Ventricular/fisiologia
4.
Eur J Heart Fail ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38899626

RESUMO

AIMS: Haemodynamic monitoring using implantable pressure sensors reduces the risk of heart failure (HF) hospitalizations. Patient self-management (PSM) of haemodynamics in HF has the potential to personalize treatment, increase adherence, and reduce the risk of worsening HF, while lowering clinicians' burden. METHODS AND RESULTS: The VECTOR-HF I and IIa studies are prospective, single-arm, open-label clinical trials assessing safety, usability and performance of left atrial pressure (LAP)-guided HF management using PSM in New York Heart Association class II and III HF patients. Physician-prescribed LAP thresholds trigger patient self-adjustment of diuretics. Primary endpoints include the ability to perform LAP measurements and transmit data to the healthcare provider (HCP) interface and the patient guidance application, and safety outcomes. This is an interim analysis of 13 patients using the PSM approach. Over 12 months, no procedure- or device-related major adverse cardiovascular or neurological events were observed, and there were no failures to obtain measurements from the sensor and transmit the data to the HCP interface and the patient guidance application. Patient adherence was 91.4%. Using PSM, annualized HF hospitalization rate significantly decreased compared to a similar period prior to PSM utilization (0 admissions vs. 0.69 admissions over 11.84 months, p = 0.004). At 6 months, 6-min walk test distance and the Kansas City Cardiomyopathy Questionnaire overall summary score demonstrated significant improvement. CONCLUSIONS: Interim findings suggest that PSM using a LAP monitoring system is feasible and safe. PSM is associated with high patient adherence, potentially improving HF patients' functional status, quality of life, and limiting HF hospitalizations.

5.
Eur J Heart Fail ; 25(6): 902-911, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37092287

RESUMO

AIMS: In heart failure (HF), implantable haemodynamic monitoring devices have been shown to optimize therapy, anticipating clinical decompensation and preventing hospitalization. Direct left-sided haemodynamic sensors offer theoretical benefits beyond pulmonary artery pressure monitoring systems. We evaluated the safety, usability, and performance of a novel left atrial pressure (LAP) monitoring system in HF patients. METHODS AND RESULTS: The VECTOR-HF study (NCT03775161) was a first-in-human, prospective, multicentre, single-arm, clinical trial enrolling 30 patients with HF. The device consisted of an interatrial positioned leadless sensor, able to transmit LAP data wirelessly. After 3 months, a right heart catheterization was performed to correlate mean pulmonary capillary wedge pressure (PCWP) with simultaneous mean LAP obtained from the device. Remote LAP measurements were then used to guide patient management. The miniaturized device was successfully implanted in all 30 patients, without acute major adverse cardiac and neurological events (MACNE). At 3 months, freedom from short-term MACNE was 97%. Agreement between sensor-calculated LAP and PCWP was consistent, with a mean difference of -0.22 ± 4.92 mmHg, the correlation coefficient and the Lin's concordance correlation coefficient values were equal to 0.79 (p < 0.0001) and 0.776 (95% confidence interval 0.582-0.886), respectively. Preliminary experience with V-LAP-based HF management was associated with significant improvements in New York Heart Association (NYHA) functional class (32% of patients reached NYHA class II at 6 months, p < 0.005; 60% of patients at 12 months, p < 0.005) and 6-min walk test distance (from 244.59 ± 119.59 m at baseline to 311.78 ± 129.88 m after 6 months, p < 0.05, and 343.95 ± 146.15 m after 12 months, p < 0.05). CONCLUSION: The V-LAP™ monitoring system proved to be generally safe and provided a good correlation with invasive PCWP. Initial evidence also suggests possible improvement in HF clinical symptoms.


Assuntos
Pressão Atrial , Insuficiência Cardíaca , Humanos , Cateterismo Cardíaco/métodos , Estudos Prospectivos , Pressão Propulsora Pulmonar
6.
Am Heart J ; 163(4): 632-48, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22520530

RESUMO

BACKGROUND: Despite lower risks of access site-related complications with transradial approach (TRA), its clinical benefit for percutaneous coronary intervention (PCI) is uncertain. We conducted a systematic review and meta-analysis of clinical studies comparing TRA and transfemoral approach (TFA) for PCI. METHODS: Randomized trials and observational studies (1993-2011) comparing TRA with TFA for PCI with reports of ischemic and bleeding outcomes were included. Crude and adjusted (for age and sex) odds ratios (OR) were estimated by a hierarchical Bayesian random-effects model with prespecified stratification for observational and randomized designs. The primary outcomes were rates of death, combined incidence of death or myocardial infarction, bleeding, and transfusions, early (≤ 30 days) and late after PCI. RESULTS: We collected data from 76 studies (15 randomized, 61 observational) involving a total of 761,919 patients. Compared with TFA, TRA was associated with a 78% reduction in bleeding (OR 0.22, 95% credible interval [CrI] 0.16-0.29) and 80% in transfusions (OR 0.20, 95% CrI 0.11-0.32). These findings were consistent in both randomized and observational studies. Early after PCI, there was a 44% reduction of mortality with TRA (OR 0.56, 95% CrI 0.45-0.67), although the effect was mainly due to observational studies (OR 0.52, 95% CrI 0.40-0.63, adjusted OR 0.49 [95% CrI 0.37-0.60]), with an OR of 0.80 (95% CrI 0.49-1.23) in randomized trials. CONCLUSION: Our results combining observational and randomized studies show that PCI performed by TRA is associated with substantially less risks of bleeding and transfusions compared with TFA. Benefit on the incidence of death or combined death or myocardial infarction is found in observational studies but remains inconclusive in randomized trials.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Angioplastia Coronária com Balão/efeitos adversos , Humanos , Resultado do Tratamento
7.
J Cardiovasc Transl Res ; 15(1): 61-66, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34075553

RESUMO

There is an important need to develop a transcatheter/trans-septal-like model which will allow deliverability of mitral valve devices at the right angulation and height above the mitral annulus similar to the human patient. A ministernotomy allowing for TEE probe to be introduced transpericardially was performed in seven animals. In three, a standard trans-septal approach was used to attempt to deliver a device to the level of the mitral plane with a human delivery system. In four cases, a Dacron tube was connected to the RPV and the device introduced to the LA. Under TEE equivalent imaging, the device was then successfully steered to the mitral plane in all cases, having failed in all trans-septal attempts. A combination of transpericardial echocardiographic imaging (TPE) and RPV approach to the LA facilitated successful human-like mitral valve device implantation.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Veias Pulmonares , Animais , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Veias Pulmonares/cirurgia , Suínos
8.
J Cardiovasc Transl Res ; 15(1): 84-94, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34115322

RESUMO

High-frequency QRS (HFQRS) analysis of surface ECG is a reliable marker of cardiac ischemia (CI). This study aimed to assess the response of HFQRS signals from standard intracardiac electrodes (iHFQRS) to CI in swine and compare them with conventional ST-segment deviations. Devices with three intracardiac leads were implanted in three swine in a controlled environment. CI was induced by inflating a balloon in epicardial coronary arteries. A designated signal-processing algorithm was applied to quantify the iHFQRS content before, during, and after each occlusion. iHFQRS time responses were compared to conventional ST-segment deviations. Thirty-three over thirty-nine (85%) of the occlusions presented significant reduction in the iHFQRS signal, preceding ST-segment change, being the only indicator of CI in brief occlusions. iHFQRS was found to be an early indicator for the onset of CI and demonstrated superior sensitivity to conventional ST-segment deviations during brief ischemic episodes.


Assuntos
Doença da Artéria Coronariana , Isquemia Miocárdica , Animais , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Isquemia , Isquemia Miocárdica/diagnóstico , Suínos
9.
Catheter Cardiovasc Interv ; 77(5): 700-6, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20824765

RESUMO

BACKGROUND: In most patients with atrial fibrillation (AF) and stroke, there is thrombotic embolization from the left atrial appendage (LAA). Percutaneous closure of the LAA is a novel alternative for the treatment of patients with AF at a high risk of stroke, in whom long-term anticoagulation therapy is not possible or not desired. This study details the initial experience with the Amplatzer Cardiac Plug (ACP) in humans. METHODS: Investigator-initiated retrospective preregistry data collection to evaluate procedural feasibility and safety up to 24 hr after implantation of the ACP, a nitinol device designed for percutaneous trans-septal implantation in LAA of patients with paroxysmal, permanent, or persistent AF. RESULTS: In 137 of 143 patients, LAA occlusion was attempted, and successfully performed in 132 (96%). There were serious complications in 10 (7.0%) patients (three patients with ischemic stroke; two patients experienced device embolization, both percutaneously recaptured; and five patients with clinically significant pericardial effusions). Minor complications were insignificant pericardial effusions in four, transient myocardial ischemia in two, and loss of the implant in the venous system in one patient. CONCLUSION: The implantation of the ACP device is a feasible method for percutaneous occlusion of the LAA.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Ligas , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Cateterismo Cardíaco/efeitos adversos , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
10.
Can J Cardiol ; 37(7): 1027-1040, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33753201

RESUMO

Mitral regurgitation (MR) is a common condition causing significant morbidity and mortality in the Western world. Although surgical therapy has developed over 5 decades to provide solutions, only a minority of patients undergo surgery. The last decade has seen the emergence and application of multiple transcatheter techniques in attempts to address this undertreated population with the large clinical experience of MitraClip providing the most insight. Clear understanding of the pathophysiology of different MR types as well as the role of particularly secondary MR on patient's clinical syndrome allow for better prediction as to which patient subgroups will benefit from different repair techniques or intervention at all. Most of the techniques are based on surgical technique and are applied as single-device/technique solutions, whether leaflet, chordal, or annular solutions, but with broadening experience, combination therapies are likely to find a place in creating a more complete and surgical-like solution.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Terapia Combinada/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia
11.
J Interv Cardiol ; 23(2): 152-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20236215

RESUMO

OBJECTIVES: The aim of this study was to compare lesion dimensions as determined by a three-dimensional quantitative coronary angiographic (QCA) system to that of a validated two-dimensional QCA system. BACKGROUND: In an era of drug-eluting stents, device sizing has become an important clinical application of online QCA. The CardiOp-B system integrates two standard angiographic projections to provide a three-dimensional reconstruction of the arterial segment of interest. METHODS: Phase 1 - 47 stenoses from consecutive coronary angiograms were assessed in two projections with both systems providing two data sets for the CMS-Medis system and a single data set for CardiOp-B. Phase 2--a perspex phantom with a known lesion length, was analyzed at increasing degrees of foreshortening with acceptance criteria set at 5% from the absolute value. RESULTS: Phase 1 demonstrated an adequate correlation between the CardiOp-B and Medis systems when minimal luminal diameter was measured in the optimal view (1.32 +/- 0.47 mm vs 1.42 +/- 0.49 mm respectively; r = 0.82). A stronger correlation was noted when length was measured (25.27 +/- 10.76 mm and 21.32 +/- 8.08 mm, respectively; r = 0.95); however CardiOp-B provided a consistently longer length (P < 0.0001). On phantom length measurements the mean accuracy result for the CardiOp-B system was -1.3%. This compared favorably with the two-dimensional system where all measures performed at greater than 20 degrees of for shortening were beyond the 5% criteria from the known length. CONCLUSIONS: Three-dimensional QCA provides accurate and precise vessel diameter assessments. Length assessments are consistently longer than two-dimensional measures and are significantly less affected by foreshortened projections.


Assuntos
Angiografia Coronária/métodos , Angiografia Coronária/normas , Imageamento Tridimensional/normas , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
12.
EuroIntervention ; 15(14): 1291-1296, 2020 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-31113765

RESUMO

The neuroprotective effects of hypothermia have been demonstrated in experimental models and clinical trials. Experimental studies indicate that improved efficacy and broadened indications can be achieved with moderate to deep hypothermia. The TwinFlo catheter was designed to provide very rapid, deep and selective brain cooling with faster cooling rates, and temperatures much lower than those which can be achieved by any other hypothermia device and technique. This report describes the experimental in vivo studies and initial clinical experience with the TwinFlo catheter.


Assuntos
Hipotermia Induzida , Encéfalo , Catéteres , Temperatura Baixa , Neuroproteção
13.
Ann Thorac Surg ; 110(3): e221-e223, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32057815

RESUMO

Two high-risk patients were successfully treated with concomitant implantation of a transapical off-pump beating heart semirigid D-shape annuloplasty device combined in 1 case with a transfemoral edge-to-edge device and in another with transapical chordal implantation. The significant anteroposterior diameter reduction offered by the annuloplasty implantation maximized the leaflet coaptation obtained by the prolapse correction performed with the leaflet devices. Combining the transcatheter annuloplasty device and leaflet/chordal repair technologies represents progress toward definitive transcatheter treatment of degenerative mitral valve disease.


Assuntos
Procedimentos Endovasculares/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler em Cores , Procedimentos Endovasculares/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Desenho de Prótese
14.
J Cardiovasc Transl Res ; 12(4): 290-298, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30604310

RESUMO

The V-LAP™ measures left atrial pressure (LAP) and enables bi-directional communications with an external unit, designed to monitor heart failure patients. We hereby describe the pre-clinical experience. Following an ex vivo phase, the system was implanted at the interatrial septum of 10 ovine subjects. LAP readouts were compared with pulmonary capillary wedge pressure (PCWP) at index procedure and 1, 2 and 3-6 months after the implantation, at rest and after volume loading. Histopathology assessment (n = 8) was performed up to 50 weeks post procedure. Procedural success was 100%. Measurements showed a mean difference of 0.19 ± 2.51 mmHg. During this period, correlation of V-LAP™ with PCWP was excellent (R2 = 0.95, for 119 total measurements). There were no major adverse events related to the V-LAP™ system. In an animal model, the implantation of the novel wireless left atrial pressure sensor V-LAP™ was feasible, safe, and showed good accuracy and precision.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Insuficiência Cardíaca/diagnóstico , Telemedicina/instrumentação , Telemetria/instrumentação , Transdutores de Pressão , Tecnologia sem Fio/instrumentação , Animais , Desenho de Equipamento , Estudos de Viabilidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Teste de Materiais , Modelos Animais , Valor Preditivo dos Testes , Pressão Propulsora Pulmonar , Reprodutibilidade dos Testes , Carneiro Doméstico , Sus scrofa , Fatores de Tempo
16.
Catheter Cardiovasc Interv ; 71(2): 175-83, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-17985377

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) of coronary bifurcation lesions remains a subject of debate. Many studies have been published in this setting. They are often small scale and display methodological flaws and other shortcomings such as inaccurate designation of lesions, heterogeneity, and inadequate description of techniques implemented. METHODS: The aim is to propose a consensus established by the European Bifurcation Club (EBC), on the definition and classification of bifurcation lesions and treatments implemented with the purpose of allowing comparisons between techniques in various anatomical and clinical settings. RESULTS: A bifurcation lesion is a coronary artery narrowing occurring adjacent to, and/or involving, the origin of a significant side branch. The simple lesion classification proposed by Medina has been adopted. To analyze the outcomes of different techniques by intention to treat, it is necessary to clearly define which vessel is the distal main branch and which is (are) the side branche(s) and give each branch a distinct name. Each segment of the bifurcation has been named following the same pattern as the Medina classification. The classification of the techniques (MADS: Main, Across, Distal, Side) is based on the manner in which the first stent has been implanted. A visual presentation of PCI techniques and devices used should allow the development of a software describing quickly and accurately the procedure performed. CONCLUSION: The EBC proposes a new classification of bifurcation lesions and their treatments to permit accurate comparisons of well described techniques in homogeneous lesion groups.


Assuntos
Angioplastia Coronária com Balão/métodos , Estenose Coronária/classificação , Estenose Coronária/terapia , Implantação de Prótese/métodos , Stents , Terminologia como Assunto , Angiografia Coronária/normas , Estenose Coronária/diagnóstico por imagem , Humanos
17.
Can J Cardiol ; 39(12): 1957-1958, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37716643
18.
Isr Med Assoc J ; 9(4): 290-3, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17491224

RESUMO

BACKGROUND: Femoral artery vascular complications are the most common adverse events following cardiac catheterization. Smaller diameter introducer sheaths and catheters are likely to lower the puncture site complication rate but may hinder visualization. OBJECTIVES: To evaluate the safety and angiographic quality of 4 French catheters. METHODS: The study was designed to simulate real-life operator-based experience. Diagnostic angiography was performed with either 4F or 6F diagnostic catheters; the size of the catheter used in each patient was predetermined by the day of the month. Patients undergoing 4F and 6F diagnostic angiography were ambulated after 4 and 6 hours, respectively. The following technical parameters were recorded by the operator: ease of introducer sheath insertion, ease of coronary intubation, ease of injection, coronary opacification, collateral flow demonstration, and overall assessment. Adverse events were recorded in all patients and included minor bleeding, major bleeding (necessitating blood transfusion), minor hematoma, major hematoma, pseudo-aneurysm formation and arteriovenous fistula. RESULTS: The study group included 177 patients, of whom 91 were in the 4F arm and 86 in the 6F arm. Demographic and procedural data were similar in both groups. Seventy-seven percent of 6F and 50% of 4F procedures were evaluated as excellent (P < 0.05). This difference was attributed to easier intubation of the coronary ostium and contrast material injection, increased opacification of the coronary arteries, and demonstration of collateral flow with 6F catheters. Complications occurred in 22% of patients treated with 6F catheters and in 10% of those treated with 4F catheters (P = 0.11). Of the 50 patients who switched from 4F to 6F 12% had complications. In patients undergoing diagnostic angiography, the complication rate was 10% vs. 27% (most of them minor) in the 4F and 6F groups, respectively (P < 0.05). CONCLUSIONS: Patients catheterized with 4F have fewer complications compared with 6F diagnostic catheters even when ambulated earlier. Although 4F had a reduced quality compared to 6F angiographies, they were evaluated as satisfactory or excellent in quality 85% of the time. 4F catheters have a potential for reduced hospitalization stay and are a good option for primary catheterization in patients not anticipated to undergo coronary intervention.


Assuntos
Cateterismo Periférico/instrumentação , Angiografia Coronária/métodos , Isquemia Miocárdica/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Feminino , Artéria Femoral , Seguimentos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
Tex Heart Inst J ; 44(5): 320-325, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29259501

RESUMO

The prevalence of the left circumflex coronary artery (LCx) as the culprit vessel in ST-segment-elevation myocardial infarction (STEMI) is reportedly lowest among that of the 3 main epicardial arteries, and has not been described for non-STEMI (NSTEMI) and stable angina pectoris. We sought to define the distribution of culprit arteries in these clinical presentations and suggest mechanisms for the differences. We reviewed 189 coronary angiograms of patients with STEMI, 203 with NSTEMI, and 548 with stable angina (n=940), and compared distributions of stenotic and culprit coronary arteries (lesions prompting intervention). Obstructive coronary lesions (≥50% narrowing) were more prevalent in the left anterior descending coronary artery (LAD) (36%-38%) and similar in the LCx and right coronary artery (RCA) (27%-29%), regardless of clinical presentation (P <0.01). In NSTEMI and stable angina, culprit vessels and total obstructive disease had the same distribution. In STEMI, however, a culprit LCx was significantly less prevalent (17%) than was total obstructive disease (27%; P <0.01), or a culprit LAD (47%) or RCA (34%) (both P <0.001). In our computed tomographic angiographic model of coronary longitudinal strain (percentage of shortening), LCx strain was only 1.5% ± 2.4%, versus 9.5% ± 2.9% for LAD strain and 10.1% ± 3.9% for RCA strain. In STEMI, LCx plaques seem less prone to rupturing. Culprit and total disease distributions are similar in NSTEMI and angina, suggesting a different ischemic pathophysiology in these presentations. Lower LCx longitudinal strain might contribute to reduced plaque rupture in STEMI.


Assuntos
Estenose Coronária/complicações , Vasos Coronários/cirurgia , Eletrocardiografia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Idoso , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa