Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38055845

RESUMO

AIMS: Modern clinical management of patients with an implantable cardioverter defibrillator (ICD) largely consists of remote device monitoring, although a subset is at risk of mental health issues post-implantation. We compared a 12-month web-based intervention consisting of goal setting, monitoring of patients' mental health-with a psychological intervention if needed-psychoeducational support from a nurse, and an online patient forum, with usual care on participants' device acceptance 12 months after implantation. METHODS AND RESULTS: This national, multi-site, two-arm, non-blinded, randomized, controlled, superiority trial enrolled 478 first-time ICD recipients from all 6 implantation centres in Denmark. The primary endpoint was patient device acceptance measured by the Florida Patient Acceptance Survey (FPAS; general score range = 0-100, with higher scores indicating higher device acceptance) 12 months after implantation. Secondary endpoints included symptoms of depression and anxiety. The primary endpoint of device acceptance was not different between groups at 12 months [B = -2.67, 95% confidence interval (CI) (-5.62, 0.29), P = 0.08]. Furthermore, the secondary endpoint analyses showed no significant treatment effect on either depressive [B = -0.49, 95% CI (-1.19; 0.21), P = 0.17] or anxiety symptoms [B = -0.39, 95% CI (-0.96; 0.18), P = 0.18]. CONCLUSION: The web-based intervention as supplement to usual care did not improve patient device acceptance nor symptoms of anxiety and depression compared with usual care. This specific web-based intervention thus cannot be recommended as a standardized intervention in ICD patients.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Humanos , Ansiedade/prevenção & controle , Ansiedade/psicologia , Atenção à Saúde , Internet , Qualidade de Vida/psicologia , Inquéritos e Questionários
2.
Europace ; 21(6): 900-908, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30796456

RESUMO

AIM: The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICD) in Patients with Non-ischaemic Systolic Heart Failure (HF) on Mortality (DANISH) found no overall effect on all-cause mortality. The effect of ICD implantation on health-related quality of life (HRQoL) remains to be established as previous trials have demonstrated conflicting results. We investigated the impact of ICD implantation on HRQoL in patients with non-ischaemic systolic HF, a prespecified secondary endpoint in DANISH. METHODS AND RESULTS: In DANISH, a total of 1116 patients with non-ischaemic systolic HF were randomly assigned (1:1) to ICD implantation or usual clinical care (control). Patients completed disease-specific HRQoL as assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ; 0-105, high indicating worse). Changes in HRQoL 8 months after randomization were assessed with a mixed-effects model. At randomization, MLHFQ was completed by 935 (84%) patients (n = 472 in the ICD group and n = 463 in the control group) and was reassessed in 274 (58%) and 292 (63%) patients, respectively after 8 months for the primary analysis. Patients in the ICD group vs. the control group had similar improvements in MLHFQ after 8 months [least square mean -7.0 vs. -4.2 (P = 0.13)]. A clinically relevant improvement (decrease ≥5) in the MLHFQ overall score at 8 months was observed in 151 patients in the ICD group and 148 patients in the control group [55% vs. 51%, respectively (P = 0.25)]. CONCLUSION: Implantable cardioverter-defibrillator implantation in patients with non-ischaemic systolic HF did not significantly alter HRQoL compared with patients randomized to usual clinical care.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/prevenção & controle , Qualidade de Vida , Idoso , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
BMC Cardiovasc Disord ; 18(1): 136, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29969990

RESUMO

BACKGROUND: In Denmark and other countries, there has been a shift in the management of patients with an implantable cardioverter defibrillator (ICD) with remote device monitoring largely replacing in-hospital visits. Less patient-nurse and patient-physician interaction may lead to gaps in patients' quality of care and impede patients' adaptation to living successfully with the ICD. A comprehensive eHealth intervention that include goal-setting, monitoring of symptoms of depression, anxiety, and quality of life, psychological treatment, information provision, supportive tools, online dialogues with nursing staff and access to an online community network, may help fill these gaps and be particularly beneficial to patients who suffer from anxiety and depression. This study will evaluate the effectiveness of the ACQUIRE-ICD care innovation, a comprehensive and interactive eHealth intervention, on patient-reported and clinical outcomes. METHODS: The ACQUIRE-ICD study is a multicenter, prospective, two-arm, unblinded randomised controlled superiority trial that will enroll 478 patients implanted with a first-time ICD or ICD with cardiac synchronisation therapy (CRT-D) from the six implanting centers in Denmark. The trial will evaluate the clinical effectiveness and cost-effectiveness of the ACQUIRE-ICD care innovation, as add-on to usual care compared with usual care alone. The primary endpoint, device acceptance, assessed with the Florida Patient Acceptance Survey, is evaluated at 12 months' post implant. Secondary endpoints, evaluated at 12 and 24 months' post implant, include patient-reported outcomes, return to work, time to first ICD therapy and first hospitalisation, mortality and cost-effectiveness. DISCUSSION: The effectiveness of a comprehensive and interactive eHealth intervention that relies on patient-centred and personalised tools offered via a web-based platform targeted to patients with an ICD has not been assessed so far. The ACQUIRE-ICD care innovation promotes and facilitates that patients become active participants in the management of their disease, and as such addresses the need for a more patient-centered disease-management approach. If the care innovation proves to be beneficial to patients, it may not only increase patient empowerment and quality of life but also free up time for clinicians to care for more patients. TRIAL REGISTRATION: The trial has been registered on https://clinicaltrials.gov/ct2/show/NCT02976961 on November 30, 2016 with registration number [ NCT02976961 ].


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Medidas de Resultados Relatados pelo Paciente , Tecnologia de Sensoriamento Remoto/instrumentação , Telemedicina/instrumentação , Telemetria/instrumentação , Dinamarca , Cardioversão Elétrica/efeitos adversos , Nível de Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/psicologia , Humanos , Saúde Mental , Estudos Multicêntricos como Assunto , Valor Preditivo dos Testes , Estudos Prospectivos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-37682525

RESUMO

BACKGROUND AND AIM: There are a paucity of studies investigating workforce affiliation in connection with first-time ICD-implantation. This study explored workforce affiliation and risk markers associated with not returning to work in patients with ICDs. METHODS: Using the nationwide Danish registers, patients with a first-time ICD-implantation between 2007-2017 and of working age (30-65 years) were identified. Descriptive statistic and logistic regression models were used to describe workforce affiliation and to estimate risk markers associated with not returning to work, respectively. All analyses were stratified by indication for implantation (primary and secondary prevention). RESULTS: Of the 4,659 ICD-patients of working age, 3,300 patients (71%) were members of the workforce (employed, on sick leave or unemployed) (primary: 1428 (43%); secondary:1872 (57%)). At baseline, 842 primary and 1477 secondary prevention ICD-patients were employed. Of those employed at baseline, 81% primary and 75% secondary prevention ICD-patients returned to work within one-year, whereof more than 80% remained employed the following year. Among patients receiving sick leave benefits at baseline, 25% were employed after one-year. Risk markers of not returning to work were 'younger age' in primary prevention ICD-patients, while 'female sex', 'LVEF ≤40', 'lower income' and '≥3 comorbidities' were risk markers in secondary prevention ICD-patients. Lower educational level was a risk marker in both patient groups. CONCLUSIONS: High return-to-work proportions following ICD-implantation, with a subsequent high level of employment maintenance were found. Several significant risk markers of not returning to work were identified including 'lower educational level', that posed a risk in both patient groups.Trial registration number: Capital Region of Denmark, P-2019-051.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa