Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Magn Reson Imaging ; 59(4): 1193-1203, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37530755

RESUMO

BACKGROUND: Water T1 of the liver has been shown to be promising in discriminating the progressive forms of fatty liver diseases, inflammation, and fibrosis, yet proper correction for iron and lipid is required. PURPOSE: To examine the feasibility of an empirical approach for iron and lipid correction when measuring imaging-based T1 and to validate this approach by spectroscopy on in vivo data. STUDY TYPE: Retrospective. POPULATION: Next to mixed lipid-iron phantoms, individuals with different hepatic lipid content were investigated, including people with type 1 diabetes (N = 15, %female = 15.6, age = 43.5 ± 14.0), or type 2 diabetes mellitus (N = 21, %female = 28.9, age = 59.8 ± 9.7) and healthy volunteers (N = 9, %female = 11.1, age = 58.0 ± 8.1). FIELD STRENGTH/SEQUENCES: 3 T, balanced steady-state free precession MOdified Look-Locker Inversion recovery (MOLLI), multi- and dual-echo gradient echo Dixon, gradient echo magnetic resonance elastography (MRE). ASSESSMENT: T1 values were measured in phantoms to determine the respective correction factors. The correction was tested in vivo and validated by proton magnetic resonance spectroscopy (1 H-MRS). The quantification of liver T1 based on automatic segmentation was compared to the T1 values based on manual segmentation. The association of T1 with MRE-derived liver stiffness was evaluated. STATISTICAL TESTS: Bland-Altman plots and intraclass correlation coefficients (ICCs) were used for MOLLI vs. 1 H-MRS agreement and to compare liver T1 values from automatic vs. manual segmentation. Pearson's r correlation coefficients for T1 with hepatic lipids and liver stiffness were determined. A P-value of 0.05 was considered statistically significant. RESULTS: MOLLI T1 values after correction were found in better agreement with the 1 H-MRS-derived water T1 (ICC = 0.60 [0.37; 0.76]) in comparison with the uncorrected T1 values (ICC = 0.18 [-0.09; 0.44]). Automatic quantification yielded similar liver T1 values (ICC = 0.9995 [0.9991; 0.9997]) as with manual segmentation. A significant correlation of T1 with liver stiffness (r = 0.43 [0.11; 0.67]) was found. A marked and significant reduction in the correlation strength of T1 with liver stiffness (r = 0.05 [-0.28; 0.38], P = 0.77) was found after correction for hepatic lipid content. DATA CONCLUSION: Imaging-based correction factors enable accurate estimation of water T1 in vivo. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 1.


Assuntos
Diabetes Mellitus Tipo 2 , Imageamento por Ressonância Magnética , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Água , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Ferro , Reprodutibilidade dos Testes , Lipídeos
3.
NMR Biomed ; 30(7)2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28370530

RESUMO

Acute kidney injury (AKI) in mice caused by sustained ischemia followed by reperfusion is associated with acute tubular necrosis and renal dysfunctional blood flow. Although the principal role of the kidney is the maintenance of acid-base balance, current imaging approaches are unable to assess this important parameter, and clinical biomarkers are not robust enough in evaluating the severity of kidney damage. Therefore, novel noninvasive imaging approaches are needed to assess the acid-base homeostasis in vivo. This study investigates the usefulness of MRI-chemical exchange saturation transfer (CEST) pH imaging (through iopamidol injection) in characterizing moderate and severe AKI in mice following unilateral ischemia reperfusion injury. Moderate (20 min) and severe (40 min) ischemia were induced in Balb/C mice, which were imaged at several time points thereafter (Days 0, 1, 2, 7). A significant increase of renal pH values was observed as early as one day after the ischemia reperfusion damage for both moderate and severe ischemia. MRI-CEST pH imaging distinguished the evolution of moderate from severe AKI. A recovery of normal renal pH values was observed for moderate AKI, whereas a persisting renal pH increase was observed for severe AKI on Day 7. Renal filtration fraction was significantly lower for clamped kidneys (0.54-0.57) in comparison to contralateral kidneys (0.84-0.86) following impairment of glomerular filtration. The severe AKI group showed a reduced filtration fraction even after 7 days (0.38 for the clamped kidneys). Notably, renal pH values were significantly correlated with the histopathological score. In conclusion, MRI-CEST pH mapping is a valid tool for the noninvasive evaluation of both acid-base balance and renal filtration in patients with ischemia reperfusion injury.


Assuntos
Desequilíbrio Ácido-Base/diagnóstico por imagem , Injúria Renal Aguda/diagnóstico por imagem , Concentração de Íons de Hidrogênio , Rim/química , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Homeostase , Interpretação de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Camundongos , Camundongos Endogâmicos BALB C , Espectroscopia de Prótons por Ressonância Magnética/métodos , Traumatismo por Reperfusão/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Am Chem Soc ; 136(41): 14333-6, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-25238643

RESUMO

Chemical exchange saturation transfer (CEST) is a novel contrast mechanism for magnetic resonance imaging (MRI). CEST MRI selectively saturates exchangeable protons that are transferred to MRI-detectable bulk water signal. MRI-CEST (pH)-responsive agents are probes able to map pH in the microenvironment in which they distribute. To minimize the confounding effects of contrast agent concentration, researchers have developed ratiometric CEST imaging, which investigates contrast agents containing multiple magnetically non-equivalent proton groups, whose prototropic exchange have different pH responses. However, conventional ratiometric CEST MRI imposes stringent requirements on the selection of CEST contrasts agents. In this study, a novel ratiometric pH MRI method based on the analysis of CEST effects under different radio frequency irradiation power levels was developed. The proposed method has been demonstrated using iobitridol, an X-ray contrast agent analog of iopamidol but containing a single set of amide protons, both in vitro and in vivo.


Assuntos
Meios de Contraste , Iohexol/análogos & derivados , Rim/metabolismo , Imageamento por Ressonância Magnética/métodos , Animais , Meios de Contraste/química , Concentração de Íons de Hidrogênio , Iohexol/administração & dosagem , Iohexol/química , Camundongos , Camundongos Endogâmicos BALB C , Estrutura Molecular
5.
Nucl Med Biol ; 138-139: 108962, 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39393206

RESUMO

PURPOSE: Monitoring ß-cell mass and function would provide a better understanding of diabetes, setting the stage for truly individualized therapies. We applied a combined PET/MRI protocol to monitor engrafted islets mass and function without pre-labeling of isolated cells. A PET tracer binding to GLP-1R quantifies ß-cell mass, while Mn-CA characterizes ß-cell function. Both parameters were assessed in transplanted and native ß-cells in vivo and validated with autoradiography and mass spectrometry imaging. METHODS: Islets were collected and transplanted into the calves of C3H-mice. Accumulation of [64Cu]Ex4 and Mn-CA was examined with a PET/MRI at 1 h post-injection between 1 and 4 weeks after the transplantation. A separate blocking study with diazoxide targeted the functionality of the transplanted islets. As validation, ex vivo autoradiography and LA-ICP-MS imaging were performed after the last imaging session. RESULTS: PET/MRI monitored the engraftment of transplanted islets and visualized an increasing uptake of the PET tracer and Mn-CA. The Mn-CA accumulated at a higher islet-to-background ratio in the calf of mice than in the pancreas due to the high retention of Mn-CA in the exocrine pancreas. In vivo imaging data correlated well with autoradiography and LA-ICP-MS imaging, validating the in vivo approaches. CONCLUSION: For the quantification of ß-cell function, Mn-based contrast mechanisms between native and transplanted islets differ and require further studies for optimal biological readout. However, non-invasive PET/MRI nonetheless provides the tools to investigate the relationship between ß-cell mass and function in pancreatic islets.

6.
Diabetes ; 72(10): 1483-1492, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37478166

RESUMO

Intramyocellular lipid content (IMCL) is elevated in insulin-resistant humans, but it changes over time, and relationships with comorbidities remain unclear. We examined IMCL during the initial course of diabetes and its associations with complications. Participants of the German Diabetes Study (GDS) with recent-onset type 1 (n = 132) or type 2 diabetes (n = 139) and glucose-tolerant control subjects (n = 128) underwent 1H-MRS to measure IMCL and muscle volume, whole-body insulin sensitivity (hyperinsulinemic-euglycemic clamps; M-value), and cycling spiroergometry (VO2max). Subgroups underwent the same measurements after 5 years. At baseline, IMCL was ∼30% higher in type 2 diabetes than in other groups independently of age, sex, BMI, and muscle volume. In type 2 diabetes, the M-value was ∼36% and ∼62% lower compared with type 1 diabetes and control subjects, respectively. After 5 years, the M-value decreased by ∼29% in type 1 and ∼13% in type 2 diabetes, whereas IMCL remained unchanged. The correlation between IMCL and M-value in type 2 diabetes at baseline was modulated by VO2max. IMCL also associated with microalbuminuria, the Framingham risk score for cardiovascular disease, and cardiac autonomic neuropathy. Changes in IMCL within 5 years after diagnosis do not mirror the progression of insulin resistance in type 2 diabetes but associate with early diabetes-related complications. ARTICLE HIGHLIGHTS: Intramyocellular lipid content (IMCL) can be elevated in insulin-resistant humans, but its dynamics and association with comorbidities remain unclear. Independently of age, sex, body mass, and skeletal muscle volume, IMCL is higher in recent-onset type 2, but not type 1 diabetes, and remains unchanged within 5 years, despite worsening insulin resistance. A degree of physical fitness modulates the association between IMCL and insulin sensitivity in type 2 diabetes. Whereas higher IMCL associates with lower insulin sensitivity in people with lower physical fitness, there is no association between IMCL and insulin sensitivity in those with higher degree of physical fitness. IMCL associates with progression of microalbuminuria, cardiovascular disease risk, and cardiac autonomic neuropathy.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Resistência à Insulina , Humanos , Pré-Escolar , Diabetes Mellitus Tipo 2/metabolismo , Resistência à Insulina/fisiologia , Triglicerídeos/metabolismo , Doenças Cardiovasculares/metabolismo , Insulina/metabolismo , Músculo Esquelético/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Metabolismo dos Lipídeos
7.
Brain Sci ; 12(11)2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36358353

RESUMO

Glioblastomas are incurable primary brain tumors harboring a heterogeneous landscape of genetic and metabolic alterations. Longitudinal imaging by MRI and [18F]FET-PET measurements enable us to visualize the features of evolving tumors in a dynamic manner. Yet, close-meshed longitudinal imaging time points for characterizing temporal and spatial metabolic alterations during tumor evolution in patients is not feasible because patients usually present with already established tumors. The replication-competent avian sarcoma-leukosis virus (RCAS)/tumor virus receptor-A (tva) system is a powerful preclinical glioma model offering a high grade of spatial and temporal control of somatic gene delivery in vivo. Consequently, here, we aimed at using MRI and [18F]FET-PET to identify typical neuroimaging characteristics of the platelet-derived growth factor B (PDGFB)-driven glioma model using the RCAS-tva system. Our study showed that this preclinical glioma model displays MRI and [18F]FET-PET features that highly resemble the corresponding established human disease, emphasizing the high translational relevance of this experimental model. Furthermore, our investigations unravel exponential growth dynamics and a model-specific tumor microenvironment, as assessed by histology and immunochemistry. Taken together, our study provides further insights into this preclinical model and advocates for the imaging-stratified design of preclinical therapeutic interventions.

8.
Theranostics ; 10(1): 398-410, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31903128

RESUMO

Non-invasive imaging of ß-cells represents a desirable preclinical and clinical tool to monitor the change of ß-cell mass and the loss of function during pre-diabetic stages. Although it is widely accepted that manganese (Mn) ions are actively gated by voltage-dependent calcium channels (VDCC) in response to glucose metabolism, little is known on its specificity in vivo for quantification of islet ß-cell function using Mn and magnetic resonance imaging (MRI). On the other hand, glucagon-like-peptide-1 receptor (GLP-1R) represents a validated target for the estimation of ß-cell mass using radiolabeled exendin-4 (Ex4) and positron emission tomography (PET). However, a multiparametric imaging workflow revealing ß-cell mass and function quantitatively is still missing. Methods: We developed a simultaneous PET/MRI protocol to comprehensively quantify in vivo changes in ß-cell mass and function by targeting, respectively, GLP-1R and VDCC coupled with insulin secretion. Differences in the spatial distribution of Mn and radiolabeled Ex4 were monitored overtime in native and transgenic pancreata, characterized by spontaneous pancreatic neuroendocrine tumor development. Follow-up with mass spectrometry imaging (MSI) and autoradiography allowed the ex vivo validation of the specificity of Mn and PET tracer uptake and the detection of endogenous biometals, such as calcium and zinc, throughout the endocrine and exocrine pancreas. Results: Our in vivo data based on a volumetric PET/MRI readout for native pancreata and insulinomas connects uptake of Mn measured at early imaging time points to high non-specific binding by the exocrine tissue, while specific retention was only found 24 h post injection. These results are supported by cross-validation of the spatial distribution of exogenous 55Mn and endogenous 44Ca and 64Zn as well with the specific internalization of the radiolabeled peptide targeting GLP-1R. Conclusion: Simultaneous PET/MR imaging of the pancreas enabled the comprehensive in vivo quantification of ß-cell function and mass using Mn and radiolabeled Ex4. Most important, our data revealed that only late time-point measurements reflect the Mn uptake in the islet ß-cells, while early time points detect non-specific accumulation of Mn in the exocrine pancreas.


Assuntos
Células Secretoras de Insulina , Imageamento por Ressonância Magnética , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Animais , Canais de Cálcio/metabolismo , Receptor do Peptídeo Semelhante ao Glucagon 1/metabolismo , Células Secretoras de Insulina/patologia , Células Secretoras de Insulina/ultraestrutura , Manganês/química , Camundongos , Camundongos Transgênicos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Compostos Radiofarmacêuticos/química
9.
Invest Radiol ; 51(3): 155-62, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26460826

RESUMO

OBJECTIVES: The aim of this study was to evaluate 4 nonionic x-ray iodinated contrast agents (CAs), commonly used in radiographic procedures, as novel chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) agents by assessing their in vitro exchange properties and preliminary in vivo use as tumor enhancing agents. MATERIALS AND METHODS: The CEST properties, as function of pH (range, 5.5-7.9) and of radio frequency conditions (irradiation field strength range of 1-9 µT and time of 1-9 seconds), have been determined at 7 T and 310 K for 4 x-ray CAs commonly used in clinical settings, namely, iomeprol, iohexol, ioversol, and iodixanol. Their in vivo properties have been investigated upon intravenous injection in a murine HER2+ breast tumor model (n = 4 mice for each CA) using both computed tomography (CT) and MRI modalities. RESULTS: The prototropic exchange rates measured for the 4 investigated iodinated molecules showed strong pH dependence with base catalyzed exchange rate that was faster for monomeric compounds (20-4000 Hz in the pH range of 5.5-7.9). Computed tomography quantification showed marked (up to 2 mg I/mL concentration) and prolonged accumulation (up to 30 minutes postinjection) inside tumor regions. Among the 4 agents we tested, iohexol and ioversol display good CEST contrast properties at 7 T, and in vivo results confirmed strong and prolonged contrast enhancement of the tumors, with elevated extravasation fractions (74%-91%). A strong and significant correlation was found between CT and CEST-MRI tumor-enhanced images (R = 0.70, P < 0.01). CONCLUSIONS: The obtained results demonstrate that iohexol and ioversol, 2 commonly used radiographic compounds, can be used as MRI perfusion agents, particularly useful when serial images acquisitions are needed to complement CT information.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética , Neoplasias Mamárias Experimentais/diagnóstico , Tomografia Computadorizada por Raios X , Animais , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Iohexol/química , Iopamidol/análogos & derivados , Iopamidol/química , Camundongos , Ácidos Tri-Iodobenzoicos/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa