Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(1): 16, 2023 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-38135770

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the influence of crestal and subcrestal implant position on development of peri-implant diseases. MATERIALS AND METHODS: The study was designed as a retrospective clinical and radiographic analysis. Implant-supported fixed dental prostheses were allocated in two groups: with the shoulder (i) placed in sub-crestal level and (ii) placed at bone level. For each patient, the following clinical variables were assessed: FMPS, FMBS, PlI, BOP, and PD. After prothesis delivery, an intraoral radiograph was obtained; this exam was performed also at 5 years of observation period. RESULTS: No statistically significant difference was found in terms of FMPS and FMBS at baseline and after 5 years follow-up (P < 0.05). A statistically significant difference was assessed between PD of control group and test group (P = 0.042). Patient-based analysis showed a 25.6% of peri-implant mucositis and 32.6% of peri-implantitis for implants placed with the shoulder in crestal position, while for implants inserted in sub-crestal position the percentage of peri-implant-mucositis and peri-implantitis were 19%; no statistically significant difference was found between groups after 5 years (P < 0.05). CONCLUSIONS: Within the limitation of the present study, the clinical and radiographic outcomes showed that the percentage of peri-implant mucositis and peri-implantitis was not statistically significant for both groups after 5 years follow-up. CLINICAL RELEVANCE: The outcomes of present study clinically demonstrated that a deep position of implant shoulder did not provide any benefits. On the contrary, it may be considered a possible risk indicator for implant diseases.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Mucosite , Peri-Implantite , Humanos , Peri-Implantite/diagnóstico por imagem , Estudos Retrospectivos , Perda do Osso Alveolar/diagnóstico por imagem
2.
Eur J Dent ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698614

RESUMO

OBJECTIVES: This in vitro study aimed to investigate the impact of bicarbonate air-abrasive powders and ultrasonic scaling with stainless steel tips on the micro- and nanotopography and roughness of three different implant-abutment junction titanium surfaces. MATERIALS AND METHODS: Three types of sterile and decontaminated titanium surfaces (RS, UTM, XA) were used for analysis. Nine disks per surface type were subjected to micro- and nanotopography analysis, scanning electron microscopy (SEM), roughness analysis, and fibroblast cultivation. Ultrasonic debridement and air polishing were performed on the surfaces. Human dermal fibroblasts were cultured on the surfaces for 5 days. STATISTICAL ANALYSIS: Data analysis adhered to ISO 25178 standards for surface texture assessment. SEM micrographs were used to reconstruct areas for extracting roughness parameters. Excel and Mex 6.0 software were utilized for quantitative and stereoscopic analysis. RESULTS: The study found varying effects on surface roughness posttreatment. RS Disco samples exhibited higher surface roughness compared with UTM and XA samples, both in average and nanoscale roughness. Decontamination led to increased surface roughness for all samples, particularly RS Disco. Fibroblast growth tests revealed enhanced cell network formation on decontaminated discs, possibly due to increased nanoscale roughness or the presence of bicarbonate salts. CONCLUSION: The study underscores the complex interplay between surface topography, microbial biofilm, and treatment efficacy in peri-implant disease management. While smoother surfaces may resist biofilm accumulation, increased nanoscale roughness postdecontamination can enhance fibroblast attachment and soft tissue integration. This dichotomy highlights the need for tailored treatment protocols that consider material-specific factors, emphasizing that successful implant therapy should balance microbial control with conducive surface characteristics for long-term osseointegration and soft tissue stability.

3.
J Clin Med ; 11(13)2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35806937

RESUMO

Background: An adequate blood supply plays a leading role in the healing process of the post-extractive socket; its coagulation leads to fibrin clot formation, which acts as a physical barrier able to prevent postoperative bleeding and microbial infection. The purpose of this study was to evaluate the effectiveness of antiaggregant drugs in healing post-extraction sockets compared to natural wound healing. Methods: This was a single-center prospective clinical trial. Extraction sockets allocated in healthy patients and in patients assuming antiplatelet drugs were considered. Thirty consecutive patients under (treated with/in treatment with) oral antiplatelet treatment were enrolled in the test group. In order to provide a control group, 30 consecutive patients meeting all the exclusion and inclusion criteria were enrolled. The extraction of the mono-radicular tooth was atraumatically performed without gingivoplasty or osteotomy procedures that could influence the healing process. Photographs were obtained before and immediately after surgery and at 3-, 7-, 14- and 28-days follow-up. Results: All patients assumed the prescribed therapy and their post-operative recovery was uneventful without any kind of post-extractive complications. The results of inter-group comparison show that on the third and seventh days of follow-up, the antiplatelet group expressed a statistically significant higher level of healing compared to the control group (p < 0.05), while no statistically significant differences were recorded at 14- and 28-days follow-up. Conclusions: Patients treated with antiplatelet agents seemed to show that this therapy can positively affect the healing process after tooth extractions.

4.
Materials (Basel) ; 14(22)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34832201

RESUMO

BACKGROUND: Considerations about implant surface wear and metal particles released during implant placement have been reported. However, little is known about implant surface macro- and microstructural components, which can influence these events. The aim of this research was to investigate accurately the surface morphology and chemical composition of commercially available dental implants, by means of multivariate and multidimensional statistical analysis, in order to predict their effect on wear onset and particle release during implant placement. METHODS: The implant surface characterization (roughness, texture) was carried out through Confocal Microscopy and SEM-EDS analysis; the quantitative surface quality variables (amplitude and hybrid roughness parameters) were statistically analyzed through post hoc Bonferroni's test for pair comparisons. RESULTS: The parameters used by discriminant analysis evidenced several differences in terms of implant surface roughness between the examined fixtures. In relation to the observed surface quality, some of the investigated implants showed the presence of residuals due to the industrial surface treatments. CONCLUSIONS: Many structural components of the dental implant surface can influence the wear onset and particles released during the implant placement.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa