1.
J Appl Clin Med Phys ; 23(8): e13713, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35775691

RESUMO

The most recent statement published by the International Commission on Radiological Protection describes a reduction in the maximum allowable occupational eye lens dose from 150 to 20 mSv/year (averaged over 5-year periods). Exposing the eye lens to radiation is a concern for nuclear medicine staff who handle radionuclide tracers with various levels of photon energy. This study aimed to define the optimal dosimeter and means of measuring the amount of exposure to which the eye lens is exposed during a routine nuclear medicine practice. A RANDO human phantom attached to Glass Badge and Luminess Badge for body or neck, DOSIRIS and VISION for eyes, and nanoDot for body, neck, and eyes was exposed to 99m Tc, 123 I, and 18 F radionuclides. Sealed syringe sources of each radionuclide were positioned 30 cm from the abdomen of the phantom. Estimated exposure based on measurement conditions (i.e., air kerma rate constants, conversion coefficient, distance, activity, and exposure time) was compared measured dose equivalent of each dosimeter. Differences in body, neck, and eye lens dosimeters were statistically analyzed. The 10-mm dose equivalent significantly differed between the Glass Badge and Luminess Badge for the neck, but these were almost equivalent at the body. The 0.07-mm dose equivalent for the nanoDot dosimeters was greatly overestimated compared to the estimated exposure of 99m Tc and 123 I radionuclides. Measured dose equivalents of exposure significantly differed between the body and eye lens dosimeters with respect to 18 F. Although accurately measuring radiation exposure to the eye lenses of nuclear medicine staff is conventionally monitored using dosimeters worn on the chest or abdomen, eye lens dosimeters that provide a 3-mm dose equivalent near the eye would be a more reliable means of assessing radiation doses in the mixed radiation environment of nuclear medicine.


Assuntos
Cristalino , Medicina Nuclear , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Radioisótopos
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 76(12): 1237-1247, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33342942

RESUMO

Targeted radioisotope therapy (TRT) is a radiotherapy using radioisotope or drug incorporating it and has been used as a treatment for selectively irradiating cancer cells. In recent years, interest in TRT has increased due to improvements in radionuclide production technology, development of new drugs and imaging modalities, and improvements in radiation technology. In order to enhance the effect of TRT, measurement of individual radiation doses to tumor tissue and organs at risk is important using highly quantitative nuclear medicine images. In this paper, we present a review of literature on optimization of TRT, which is a new research area from the perspective of radiation technology.


Assuntos
Medicina Nuclear , Tecnologia Radiológica , Radioisótopos , Cintilografia
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 74(12): 1443-1448, 2018 12.
Artigo em Japonês | MEDLINE | ID: mdl-30568095

RESUMO

Radionuclide therapy has been used to help manage a range of diseases and has a role of growing importance, with an increasing impact on clinical practice globally. A survey in the field of Radionuclide therapy was conducted by reviewing 4199 science abstracts of main conference (Japanese Society of Radiological Technology, Japanese Society of Nuclear Medicine, Japanese Society of Nuclear Medicine Technology, Society of Nuclear Medicine and Molecular Imaging, European Association of Nuclear Medicine) held in 2016. This survey consisted of research content, modality for evaluation, dosimetry, radionuclide, and researcher's country. There tend to be a lot of studies related to targeted radionuclide therapy more than Japan (4%) in the United States (11%) or Europe (13%). Radiopharmaceuticals still un-approving in Japan were used in some of these studies. And many studies on dosimetry using PET or SPECT imaging were confirmed in the United States (37%) or in Europe (25%) compared with in Japan (14%). This survey has clarified the current status of Japan and global trend in the field of radionuclide therapy.


Assuntos
Medicina Nuclear , Radioisótopos , Europa (Continente) , Japão , Radioisótopos/uso terapêutico , Cintilografia , Inquéritos e Questionários , Estados Unidos
4.
Artigo em Japonês | MEDLINE | ID: mdl-29925748

RESUMO

PURPOSE: The AI-300 automated infusion device (Sumitomo Heavy Industries, Ltd., Tokyo, Japan) is subject to administration error as a function of smaller volumes of 18F-FDG dispensed via a three-way cock supplied with a disposable kit. The present study aimed to validate the administration accuracy of the AI-300 using an improved disposable kit for quantitative positron emission tomography (PET) assessment. METHODS: We determined administration accuracy between the improved and previous disposable kits by measuring variations in dispensed volumes and radioactive concentrations of 18F-FDG according to the criteria of the Japanese Society of Nuclear Medicine. A reference value was generated by measuring radioactivity using a standard dose calibrator. RESULTS: The values obtained using the previous kit deviated from the reference values by a maximum of -10.6%, and the deviation depended on dispensed volumes of 18F-FDG<0.25 mL. In contrast, the values were relatively stable when using the improved kit with dispensed 18F-FDG volumes < 0.25 mL. Variations in radioactive concentrations were relatively stable using the improved kit, whereas that of the previous kit was slightly unstable at high radioactive concentrations. CONCLUSION: The administration accuracy of the AI-300 using the previous kit varied considerably according to smaller dispensed volumes, but the improved kit might alleviate this problem. The present results indicated that the improved disposal kit should be immediately implemented to eliminate uncertainty surrounding quantitative PET findings.


Assuntos
Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Fluordesoxiglucose F18 , Japão , Tóquio
5.
Artigo em Japonês | MEDLINE | ID: mdl-28637958

RESUMO

PURPOSE: Several cross-calibration schemes have been proposed to produce quantitative values in bone SPECT imaging. Differences in the radionuclide sources and geometric conditions can decrease the accuracy of cross-calibration factor (CCF). The present study aimed to validate the effects of calibration schemes using different sources under various geometric conditions. METHODS: Temporal variations as well as variations in acquisition counts and the shapes of 57Co standard and 99mTc point sources and a 99mTc disk source were determined. The effects of the geometric conditions of the source-to-camera distance (SCD) and lateral distance on the CCF were investigated by moving the camera or source away from the origin. The system planar sensitivity of NEMA incorporated into a Symbia Intevo SPECT/CT device (Siemens®) was defined as reference values. RESULTS: The temporal variation in CCF using the 57Co source was relatively stable within the range of 0.7% to 2.3%, whereas the 99mTc source ranged from 2.7% to 7.3%. In terms of source shape, the 57Co standard point source was the most stable. Both SCD and lateral distance decreased as a function of distance from the origin. Errors in the geometric condition were higher for the 57Co standard point source than the 99mTc disk source. CONCLUSIONS: Different calibration schemes influenced the reliability of quantitative values. The 57Co standard point source was stable over a long period, and this helped to maintain the quality of quantitative SPECT/CT imaging data. The CCF accuracy of the 99mTc source decreased depending on the preparative method. The method of calibration for quantitative SPECT should be immediately standardized to eliminate uncertainty.


Assuntos
Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Calibragem , Genoma , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 73(11): 1132-1139, 2017.
Artigo em Japonês | MEDLINE | ID: mdl-29151546

RESUMO

OBJECTIVE: The present study aimed to reveal the influence of combination of different collimators and energy windows on the planar sensitivity and the spatial resolution during experimental 223Ra imaging, and to determine optimal imaging parameters. METHODS: A vial type source containing 223Ra solution (4.55 MBq / 5.6 ml) was placed in the air at 100 mm away from the collimator surface. Planar images were acquired with LEHR, LMEGP, ELEGP and MEGP collimators on two dual-head gamma cameras (Symbia intevo (Siemens) and Infinia 3 (GE)). We compared three energy window combinations: 1) single window at 82 keV, 2) double window at 82+154 keV, 3) triple window at 82+154+270 keV. The energy spectrum, the sensitivity and the spatial resolution, such as full-width at half-maximum (FWHM) and full-width at tenth-maximum (FWTM), of each collimator were assessed. RESULTS: Five energy spectra (at around 82, 154, 270, 351 and 405 keV) were essentially observed among four collimators. The sensitivity was high for LEHR collimator, then ELEGP and LMEGP collimator was 3-4 fold, which is greater than MEGP collimator. The 82 keV energy window of four collimators has best spatial resolution. Moreover, the spatial resolution of the 82 keV energy window with LMEGP and ELEGP collimator was almost equal to that of the triple window with MEGP collimator. CONCLUSIONS: Optimal imaging parameters were single energy window using LMEGP or ELEGP, and then triple energy window using MEGP collimator.


Assuntos
Imagens de Fantasmas , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Humanos , Masculino , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/patologia , Rádio (Elemento)
7.
Artigo em Japonês | MEDLINE | ID: mdl-28824085

RESUMO

OBJECTIVE: The present study aimed to clarify gross tumor volume (GTV) contouring accuracy at the diaphragm boundary using respiratory-gated PET/CT. METHODS: The lung/diaphragm boundary was simulated using a phantom containing 18F solution (10.6 kBq/mL). Tumors were simulated using spheres (diameter, 11-38 mm) containing 18F and located at the positions of the lungs and liver. The tumor background ratios (TBR) were 2, 4, and 8. The phantom was moved from the superior to inferior direction with a 20-mm motion displacement at 3.6 s intervals. The recovery coefficient (RC), volume RC (VRC), and standardized uptake value (SUV) threshold were calculated using stationary, non-gated (3D), and gated (4D) PET/CT. RESULTS: In lung cancer simulation, RC and VRC in 3D PET images were, respectively, underestimated and overestimated in smaller tumors, whereas both improved in 4D PET images regardless of tumor size and TBR. The optimal SUV threshold was about 30% in 4D PET images. In liver cancer simulation, RC and VRC were, respectively, underestimated and overestimated in smaller tumors, and when the TBR was lower, but both improved in 4D PET images when tumors were >17 mm and the TBR was >4. The optimal SUV threshold tended to depend on the TBR. CONCLUSIONS: The contouring accuracy of GTV was improved by considering TBR and using an optimal SUV threshold acquired from 4D PET images.


Assuntos
Diafragma , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Respiração , Humanos , Imagens de Fantasmas , Carga Tumoral
9.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(4): 339-45, 2014 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-24759214

RESUMO

OBJECTIVE: PET images are affected by scanner model, reconstruction conditions, injected dose, scan duration, patient health status and FDG radiopharmaceutical supply systems. The present study compares images of 40 patients using commercial and in-house FDG systems with one PET scanner (Aquiduo). METHODS: The PET images were evaluated using the physical indexes of NECpatient, NECdensity and SNRliver proposed by the Japanese guidelines for oncological FDG-PET/CT, and by visual assessment. RESULTS: There were no significant differences in the physical indexes between PET images generated using commercial and in-house FDG. The physical indexes were also acceptable according to the recommended Japanese guidelines. NECdensity was higher when a higher dose/body weight of commercial FDG was injected (correlation coefficient: r=0.576, p<0.001) and lower when BMI was lower and in-house FDG was injected (r=-0.786, p<0.0001). These results suggest that scan duration should be increased if the injected dose of commercial FDG/body weight is <5.5 MBq/kg, and if individuals with BMI >21.4 kg/m(2) are injected with in-house FDG. CONCLUSIONS: Scan duration should be varied depending on FDG supply systems to ensure more accurate image quality and quantitative values during evaluations of response to therapy and prognostic prediction.


Assuntos
Fluordesoxiglucose F18/normas , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/normas , Tomografia Computadorizada por Raios X , Humanos
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(2): 148-53, 2014 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-24573229

RESUMO

Quality control (QC) detects changes in the performance of gamma cameras that could adversely affect interpretations of clinical studies. We used plate and sheet (57)Co flood sources to measure extrinsic uniformity during daily QC. Each source, when placed on the top of a collimated detector, allowed the acquisition of uniform images from both detectors, thus reducing the amount of time needed to perform daily QC. No serious problems with the gamma camera system were revealed by visual checks, and changes in detector sensitivity were rapidly determined by observing daily variations in the measured values of extrinsic uniformity. Furthermore, (57)Co flood sources confer advantages in that they shorten the time required for preparation of flood sources and reduce the consequent exposure of medical staff to radiation.


Assuntos
Radioisótopos de Cobalto , Câmaras gama/normas , Radioisótopos de Cobalto/análise , Humanos , Controle de Qualidade
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(11): 1235-42, 2014 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-25410329

RESUMO

OBJECTIVE: The present study aimed at determining the quantitative accuracy of phase-based respiratory-gated PET/CT imaging using phantom and clinical studies. METHODS: The effects of target size, target-to-background ratio (TBR), and respiratory motion on PET images were estimated using a NEMA body phantom comprising six spheres (diameter 10-37mm) in a solution of F-18 of three different TBRs (4, 6, 8). The phantom was moved in a superior-inferior direction at motion displacements of 0, 10, 20 and 30 mm. Stationary images of the phantom as well as non-gated (3D) and gated (4D) images of the phantom while moving were reconstructed and the recovery coefficient (RC) of individual spheres was calculated from each image. We then determined the RC improvement rate to evaluate improvements conferred by 4D-PET/CT. We retrospectively analyzed data from 14 patients with lung cancer who were examined by 3D- and 4D-PET/CT. Each lesion on the 3D-PET/CT and each of the five phases of the 4D-PET/CT were analyzed. RESULTS: Larger motion displacement and TBR resulted in increased RC degradation for small spheres. The RC improvement rate showed that 4D acquisition improved the RC of spheres with larger motion displacement exceeding 13 mm in diameter. 4D-PET/CT alone can reduce the effects of motion blurring, but partial volume effects may still be the dominant source of quantitative inaccuracy for small lesions. The trends of phantom and clinical studies for evaluating the improvement rate were similar. CONCLUSIONS: 4D-PET/CT significantly improved the quantitative accuracy of PET images particularly when larger motion displacement exceeded 17mm in diameter such as in lung cancer.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Imageamento Tridimensional/métodos , Masculino , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
12.
Ann Nucl Med ; 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39207631

RESUMO

OBJECTIVE: Amino acid positron emission tomography (PET) examinations using anti-1-amino-3-[18F]-fluorocyclobutane-1-carboxylic acid ([18F]FACBC) were allowed for routine clinical use in July 2024. However, phantom test procedures for [18F]FACBC reconstruction parameters have not yet been established. The present study aimed to establish new phantom test procedures for [18F]FACBC brain PET imaging to determine optimal reconstruction parameters. METHODS: Background (BG) activity as well as hot sphere and target-to-background ratios (TBRs) of [18F]FACBC were estimated based on brain activity and tumor-to-normal tissue ratios (TNR) in a Japanese clinical trial of [18F]FACBC. Phantom experiments proceeded under [18F]FACBC or L-[methyl-11C]-methionine ([11C]MET) conditions. The number of iterations and the Gaussian filter parameters were determined from the reconstruction parameters %contrastmean and coefficients of variation (CVs) in ordered subset expectation maximization (OSEM) and time-of-flight (TOF) with or without point-spread-function (PSF) correction. RESULTS: The amounts of activity in the hot spheres and BG were 1.1 and 5.5 kBq/mL, respectively, and the TBR was 5.0 at the start of acquisition. The %contrastmean of all hot spheres was higher with [18F]FACBC than [11C]MET, and %contrastmean converged between 4 and 6 iterations in hot spheres with diameters < 10 mm. We used four iterations for OSEM + TOF and five for OSEM + TOF + PSF correction for [18F]FACBC and [11C]MET images. The CV was higher for [18F]FACBC than [11C]MET. The optimal sizes of Gaussian filters for OSEM + TOF and OSEM + TOF + PSF correction of image reconstruction were 5 mm for [18F]FACBC, and 4 and 3 mm, respectively, for [11C]MET images. CONCLUSIONS: We estimated phantom activity and TBR based on brain activity in a Japanese clinical trial and established new phantom test procedures for [18F]FACBC. We recommend that the optimal reconstruction parameters for [18F]FACBC should be set to the same number of iterations as [11C]MET and that the FWHM of Gaussian filter should have a few mm higher than [11C]MET to reduce image noise from brain normal tissue.

13.
Phys Eng Sci Med ; 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39133373

RESUMO

Point-spread-function (PSF) correction is not recommended for amyloid PET images due to Gibbs artifacts. Q.Clear™, a Bayesian Penalized Likelihood (BPL) reconstruction method without incorporating PSF correction reduces these artifacts but degrades image contrast by our previous findings. The present study aimed to recover lost contrast by optimizing reconstruction parameters in time-of-flight (TOF) BPL reconstruction of amyloid PET images without PSF correction. We selected candidate conditions based on a phantom study and then determined which were optimal in a clinical study. Phantom images were reconstructed under conditions of 1‒9 iterations, ß 300-1000 and γ factors from 2 to 10 in TOF-BPL without PSF correction. We evaluated the %contrast and the coefficients of variation (CV, %). Standardized uptake value ratios (SUVr) and Centiloid scales (CL) were calculated from PET images acquired from 71 participants after an [18F]flutemetamol injection. Both %contrast and CV were independent of iterations, whereas a trade-off was found between γ factors and ß. We selected a γ factors of 5 without PSF correction (iterations, 1; ß, 500) and of 10 without PSF correction (iterations, 1; ß, 800) as candidates for clinical investigation. The SUVr and CL remained stable across various conditions, and CL scales effectively discriminated amyloid PET using measured values. The optimal reconstruction parameters of TOF-BPL for [18F]flutemetamol PET images were γ factor 10, iterations 1 and ß 800, without PSF correction.

14.
Phys Med ; 123: 103399, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38852366

RESUMO

PURPOSE: The cortical uptake of tau positron emission tomography (PET) tracers corresponds to the Braak stage and reflects the distribution and progression of tau neurofibrillary tangles. The present study aimed to develop and validate the basic performance of a novel tau PET phantom, as well as to establish standard test procedures and analytical methods. METHODS: The tau PET phantom consisted of a brain simulation section simulated medial temporal lobe region and resolution and uniformity sections. The brain simulation section and hot rods and uniformity section contained 4 and 2 kBq/mL of 18F, respectively and images were acquired three times for 20 min with a PET/CT scanner. The resolution section was visually assessed with two sets of hot and cold rods. Recovery coefficients (RCs) as a quantitative value and coefficient of variation (CV) as image noise were determined based on the brain simulation and the uniformity section, respectively. RESULTS: Preparation of activity in the phantom was repeatable among three measurements. The quality of images in the brain simulation and uniformity section with the rods was good. The 5- or 6-mm rods were detected separately. The mean RCs calculated based on the VOI template were between 0.75 and 0.83. The CV at the center slice of uniformity section was 5.54%. CONCLUSIONS: We developed a novel tau PET phantom to assess quantitative value, image noise, and detectability and resolution from brain simulation section, uniformity section, and rods, respectively. This phantom will contribute to the standardization and harmonization of tau PET imaging.


Assuntos
Encéfalo , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Proteínas tau , Proteínas tau/metabolismo , Tomografia por Emissão de Pósitrons/instrumentação , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Humanos
15.
Brain Sci ; 14(4)2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38672055

RESUMO

BACKGROUND: Standard methods for deriving Centiloid scales from amyloid PET images are time-consuming and require considerable expert knowledge. We aimed to develop a deep learning method of automating Centiloid scale calculations from amyloid PET images with 11C-Pittsburgh Compound-B (PiB) tracer and assess its applicability to 18F-labeled tracers without retraining. METHODS: We trained models on 231 11C-PiB amyloid PET images using a 50-layer 3D ResNet architecture. The models predicted the Centiloid scale, and accuracy was assessed using mean absolute error (MAE), linear regression analysis, and Bland-Altman plots. RESULTS: The MAEs for Alzheimer's disease (AD) and young controls (YC) were 8.54 and 2.61, respectively, using 11C-PiB, and 8.66 and 3.56, respectively, using 18F-NAV4694. The MAEs for AD and YC were higher with 18F-florbetaben (39.8 and 7.13, respectively) and 18F-florbetapir (40.5 and 12.4, respectively), and the error rate was moderate for 18F-flutemetamol (21.3 and 4.03, respectively). Linear regression yielded a slope of 1.00, intercept of 1.26, and R2 of 0.956, with a mean bias of -1.31 in the Centiloid scale prediction. CONCLUSIONS: We propose a deep learning means of directly predicting the Centiloid scale from amyloid PET images in a native space. Transferring the model trained on 11C-PiB directly to 18F-NAV4694 without retraining was feasible.

16.
EJNMMI Phys ; 11(1): 37, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647924

RESUMO

PURPOSE: Bayesian penalised likelihood (BPL) reconstruction, which incorporates point-spread-function (PSF) correction, provides higher signal-to-noise ratios and more accurate quantitation than conventional ordered subset expectation maximization (OSEM) reconstruction. However, applying PSF correction to brain PET imaging is controversial due to Gibbs artefacts that manifest as unpredicted cortical uptake enhancement. The present study aimed to validate whether BPL without PSF would be useful for amyloid PET imaging. METHODS: Images were acquired from Hoffman 3D brain and cylindrical phantoms for phantom study and 71 patients administered with [18F]flutemetamol in clinical study using a Discovery MI. All images were reconstructed using OSEM, BPL with PSF correction, and BPL without PSF correction. Count profile, %contrast, recovery coefficients (RCs), and image noise were calculated from the images acquired from the phantoms. Amyloid ß deposition in patients was visually assessed by two physicians and quantified based on the standardised uptake value ratio (SUVR). RESULTS: The overestimated radioactivity in profile curves was eliminated using BPL without PSF correction. The %contrast and image noise decreased with increasing ß values in phantom images. Image quality and RCs were better using BPL with, than without PSF correction or OSEM. An optimal ß value of 600 was determined for BPL without PSF correction. Visual evaluation almost agreed perfectly (κ = 0.91-0.97), without depending on reconstruction methods. Composite SUVRs did not significantly differ between reconstruction methods. CONCLUSION: Gibbs artefacts disappeared from phantom images using the BPL without PSF correction. Visual and quantitative evaluation of [18F]flutemetamol imaging was independent of the reconstruction method. The BPL without PSF correction could be the standard reconstruction method for amyloid PET imaging, despite being qualitatively inferior to BPL with PSF correction for [18F]flutemetamol amyloid PET imaging.

17.
Ann Nucl Med ; 38(5): 400-407, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38466549

RESUMO

OBJECTIVE: The uptake of [11C]methionine in positron emission tomography (PET) imaging overlapped in earlier images of tumors. Bayesian penalized likelihood (BPL) reconstruction increases the quantitative values of tumors compared with conventional ordered subset-expectation maximization (OSEM). The present study aimed to grade glioma malignancy based on the new WHO 2021 classification using [11C]methionine PET images reconstructed using BPL. METHODS: We categorized 32 gliomas in 28 patients as grades 2/3 (n = 15) and 4 (n = 17) based on the WHO 2021 classification. All [11C]methionine images were reconstructed using OSEM + time-of-flight (TOF) and BPL + TOF (ß = 200). Maximum standardized uptake value (SUVmax) and tumor-to-normal tissue ratio (T/Nmax) were measured at each lesion. RESULTS: The mean SUVmax was 4.65 and 4.93 in grade 2/3 and 6.38 and 7.11 in grade 4, and the mean T/Nmax was 7.08 and 7.22 in grade 2/3 and 9.30 and 10.19 in grade 4 for OSEM and BPL, respectively. The BPL significantly increased these values in grade 4 gliomas. The area under the receiver operator characteristic (ROC) curve (AUC) for SUVmax was the highest (0.792) using BPL. CONCLUSIONS: The BPL increased mean SUVmax and mean T/Nmax in lesions with higher contrast such as grade 4 glioma. The discrimination power between grades 2/3 and 4 in SUVmax was also increased using [11C]methionine PET images reconstructed with BPL.


Assuntos
Glioma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Metionina , Teorema de Bayes , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Racemetionina , Glioma/diagnóstico por imagem , Algoritmos , Organização Mundial da Saúde
18.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(12): 1379-86, 2013 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-24366558

RESUMO

OBJECTIVES: Accurate calibration of dose calibrators (DC) is required for quantitative positron emission tomography (PET) studies to generate meaningful information. Values measured by DC depend not only on the radioactive nuclide but also the environment where measurements are taken. Therefore, DC must be calibrated at each location. The present study aimed to determine appropriate calibration values, and evaluate the performance of DC using a traceable (68)Ge/(68)Ga calibration source that is available as a surrogate (18)F source. METHODS: We used a (68)Ge/(68)Ga calibration source to determine the optimal DC value for measuring (18)F activity in the operating environment. Variations in sensitivity and geometry as well as measurement uncertainty were evaluated using the (68)Ge/(68)Ga source. We adopted the criteria of the Guide for the expression of uncertainty in measurement (GUM) to evaluate DC performance. RESULTS: Although the manufacturer's recommended (18)F calibration number for the CRC-25PET is 480, we found that the optimal number was 482. Over a period of one year, the sensitivity of the DC varied <0.1%, and the expanded uncertainty of DC measurements was 2.2%. CONCLUSION: Measurements of the certified activity of a traceable national standard were corrected, and the uncertainty of measurements as well as the accuracy of a DC were determined. Calibration numbers for DC should be regularly determined using (68)Ge/(68)Ga calibration sources at each location to ensure the most accurate results.


Assuntos
Calibragem/normas , Radioisótopos de Gálio , Germânio , Tomografia por Emissão de Pósitrons , Radioisótopos , Controle de Qualidade , Sensibilidade e Especificidade
19.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(3): 262-270, 2023 Mar 20.
Artigo em Japonês | MEDLINE | ID: mdl-36696976

RESUMO

PURPOSE: Recently, the targeted radionuclide therapy (TRT) was urgently required to adapt the practice and environment because of the implementation of novel therapeutic radiopharmaceuticals such as alpha- and beta- radionuclides therapy. The present study aimed to clarify the questionnaire survey with the current situation (safety controls for workers and patients) at Japanese TRT facilities. METHODS: The massive questionnaire survey, 2 months from October to November 2021, was conducted among nationwide 251 facilities that have performed TRT in the past two years. The alpha- and beta- therapeutic radiopharmaceuticals were categorized and answered by one representative of the facility under anonymity. We analyzed the actual situation of each facility related to occupational exposure, radiation protection, contamination inspection, patient release criteria, and dosimetry for TRT. RESULTS: The survey response rate was 69.1% (174 facilities). About 75% of these facilities reported that they either follow the guidelines or take their own measures to reduce occupational exposure. The confirmed means of patient release criteria were 68.0% with the administered radioactivity and 87.2% with the ambient dose rate. The cold run was not performed for the first time at 15.0% and 10.0% of the facilities for ß- and α-emitting radionuclides, respectively. The facilities without attachment syringe shields were 39.2% for alpha-radionuclides therapy and 20.3% for beta-radionuclides therapy. CONCLUSION: We clarified the Japanese problem for TRT practice and environment by the questionnaire survey. Our findings indicated that the Japanese guidelines and manuals for TRT were not partly followed in the nationwide facilities.


Assuntos
População do Leste Asiático , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos/uso terapêutico , Inquéritos e Questionários , Radiometria
20.
J Nucl Med ; 64(12): 1990-1997, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37857503

RESUMO

The Omni Legend 32 PET/CT system features silicon photomultiplier (SiPM)-based detectors with bismuth germanium oxide crystals and a 32-cm axial field of view (FOV). The present study aimed to determine the performance characteristics of the Omni Legend 32 PET/CT system according to National Electrical Manufacturers Association (NEMA) NU 2-2018 standards. Methods: The PET component of this system comprises 22 detector modules; each module contains 24 detector blocks with 72 bismuth germanium oxide crystals with a volume of 4.1 × 4.1 × 30 mm coupled to 18 SiPM devices with a 6 × 6 mm area, resulting in an axial FOV of 32 cm. The spatial resolution, sensitivity, count rate performance, and image quality delivered by PET were evaluated using the NEMA NU 2-2018 standard. PET images of 2 patients were evaluated to get a visual first impression of the Omni Legend 32 PET/CT system together with Precision DL. Results: The average spatial resolution at 1, 10, and 20 cm from the central axis was 4.3, 5.3, and 6.2 mm, respectively, for filtered backprojection and 3.7, 4.3, and 5.1 mm, respectively, for ordered-subset expectation maximization. The NEMA sensitivity was 47.30 and 47.05 cps/kBq at the axial center of the FOV and at a 10-cm radial offset, respectively. The scatter fraction, count rate accuracy, and peak noise-equivalent count rates were 35.4%, 1.7%, and 501.7 kcps, respectively, at 15.7 kBq/mL. Contrast recovery for the NEMA body phantom from the smallest to the largest sphere ranged from 61.3% to 93.0%, with a background variability of 5.4%-11.7% and a lung error of 5.1% for Q.Clear (ß-value, 50). Good patient image quality was obtained with the Omni Legend 32. Conclusion: The Omni Legend 32 has class-leading sensitivity and count rates within the category of whole-body PET systems while maintaining spatial resolution broadly comparable to that of other current SiPM-based PET/CT systems. This combination of properties results in a very good image quality.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Humanos , Padrões de Referência , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos