RESUMO
PURPOSE: Patients with age-related hearing loss complain often about reduced speech perception in adverse listening environment. Studies on animals have suggested that cochlear synaptopathy may be one of the primary mechanisms responsible for this phenomenon. A decreased wave I amplitude in supra-threshold auditory brainstem response (ABR) can diagnose this pathology non-invasively. However, the interpretation of the wave I amplitude in humans remains controversial. Recent studies in mice have established a robust and reliable mathematic algorithm, i.e., curve curvature quantification, for detecting cochlear synaptopathy. This study aimed to determine whether the curve curvature has sufficient test-retest reliability to detect cochlear synaptopathy in aging humans. METHODS: Healthy participants were recruited into this prospective study. All subjects underwent an audiogram examination with standard and extended high frequencies ranging from 0.125 to 16 kHz and an ABR with a stimulus of 80 dB nHL click. The peak amplitude, peak latency, curvature at the peak, and the area under the curve of wave I were calculated and analyzed. RESULTS: A total of 80 individuals with normal hearing, aged 18 to 61 years, participated in this study, with a mean age of 26.4 years. Pearson correlation analysis showed a significant negative correlation between curvature and age, as well as between curvature and extended high frequency (EHF) threshold (10-16 kHz). Additionally, the same correlation was observed between age and area as well as age and EHF threshold. The model comparison demonstrated that the curvature at the peak of wave I is the best metric to correlate with EHF threshold. CONCLUSION: The curvature at the peak of wave I is the most sensitive metric for detecting cochlear synaptopathy in humans and may be applied in routine diagnostics to detect early degenerations of the auditory nerve.
Assuntos
Cóclea , Potenciais Evocados Auditivos do Tronco Encefálico , Humanos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Masculino , Feminino , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Cóclea/fisiopatologia , Cóclea/patologia , Reprodutibilidade dos Testes , Adulto Jovem , Idoso , Sinapses/fisiologia , Sinapses/patologia , Limiar Auditivo/fisiologia , Algoritmos , Perda Auditiva OcultaRESUMO
PURPOSE: After the lifting of nonpharmaceutical interventions (NPIs) during the COVID-19 pandemic, clinical observation showed an increase in complications of acute otitis, followed by a rise in the number of mastoidectomies performed. The aim of this study was to record the number of mastoidectomies performed before, during and after the COVID-19 pandemic as an indicator for complications of acute otitis media. METHODS: Data were collected from a tertiary hospital in a university setting, as well as from four major public health insurance companies in Germany. The data of 24,824,763 German citizens during a period from 2014 until 2023 were analyzed. RESULTS: According to the data, during the COVID-19 pandemic, the number of mastoidectomies performed dropped by 54% for children aged 0-6 and by 62% for children aged 7-18. For adults, there were 30% fewer mastoidectomies performed between 2020 and 2022. After the lifting of most NPI's in the season from July 2022 to June 2023, there was a sharp increase in the number of mastoidectomies performed on patients of all ages. CONCLUSIONS: During the COVID-19 pandemic, a decrease in the number of mastoidectomies performed was seen, suggesting a lower incidence of complicated acute otitis, most likely linked to the general decrease of upper airway infections due to NPI's. In contrast, a sharp increase in the incidence of complicated otitis occurred after the hygiene measures were lifted. The current development causes a more frequent performance of mastoidectomies, thus entailing a change in the challenges for everyday clinical practice.
Assuntos
COVID-19 , Mastoidectomia , Otite Média , Humanos , COVID-19/epidemiologia , Otite Média/epidemiologia , Otite Média/cirurgia , Criança , Pré-Escolar , Lactente , Adolescente , Alemanha/epidemiologia , Adulto , Doença Aguda , Masculino , Feminino , Adulto Jovem , Pessoa de Meia-Idade , SARS-CoV-2 , Recém-Nascido , IdosoRESUMO
PURPOSE: In cochlear implantation with flexible lateral wall electrode arrays, a cochlear coverage (CC) range between 70% and 80% is considered ideal for optimal speech perception. To achieve this CC, the cochlear implant (CI) electrode array has to be chosen according to the individual cochlear duct length (CDL). Here, we mathematically analyzed the suitability of different flexible lateral wall electrode array lengths covering between 70% and 80% of the CDL. METHODS: In a retrospective cross-sectional study preoperative high-resolution computed tomography (HRCT) from patients undergoing cochlear implantation was investigated. The CDL was estimated using an otosurgical planning software and the CI electrode array lengths covering 70-80% of the CDL was calculated using (i) linear and (ii) non-linear models. RESULTS: The analysis of 120 HRCT data sets showed significantly different model-dependent CDL. Significant differences between the CC of 70% assessed from linear and non-linear models (mean difference: 2.5 mm, p < 0.001) and the CC of 80% assessed from linear and non-linear models (mean difference: 1.5 mm, p < 0.001) were found. In up to 25% of the patients none of the existing flexible lateral wall electrode arrays fit into this range. In 59 cases (49,2%) the models did not agree on the suitable electrode arrays. CONCLUSIONS: The CC varies depending on the underlying CDL approximation, which critically influences electrode array choice. Based on the literature, we hypothesize that the non-linear method systematically overestimates the CC and may lead to rather too short electrode array choices. Future studies need to assess the accuracy of the individual mathematical models.
Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Estudos Transversais , Dinâmica não Linear , Cóclea/diagnóstico por imagem , Cóclea/cirurgiaRESUMO
BACKGROUND: In the context of contact restrictions, conventional teaching is currently in need of optimization and expansion. The range of digital teaching formats in student training is very heterogeneous and their effectiveness uncertain. This study aims to investigate the extent to which an electronic ward round can be used as an alternative to the conventional ENT attendance practical course, and whether the use of electronic teaching formats has an influence on the quality of teaching. MATERIALS AND METHODS: Instead of regular attendance practicals, bedside teaching took place once a week in real time as a video stream via tablet. A total of 43 students in the seventh semester (winter semester 2020/2021) were included in the prospective study. Evaluation forms were used to examine the subjective didactic value of different visualization formats for the students. Examination results from previous years were used for comparison. RESULTS: The majority of students reported knowledge gain from the electronic rounds (93.02%) and that they were a good alternative to the traditional attendance clerkship (69.77%). The quality of the video and audio transmission as well as the comprehensibility of the case studies presented were consistently rated as good to very good. The students' examination results tended to be slightly worse in the test group compared to the control students of previous years. CONCLUSION: Integration of innovative interactive visualization options into teaching shows promising prospects as a supplement to conventional face-to-face teaching. The results of this study can contribute to the further expansion of digital teaching. Scaling up this model could be considered especially in countries with limited availability of face-to-face teaching.
Assuntos
Instrução por Computador , Estudantes de Medicina , Alemanha , Humanos , Instrução por Computador/métodos , Feminino , Masculino , Otolaringologia/educação , Interface Usuário-Computador , Currículo , Adulto , Adulto Jovem , Gravação em Vídeo , Ensino , Avaliação EducacionalRESUMO
BACKGROUND: Technological change in healthcare and the digital transformation of teaching require innovations in student teaching in medicine. New technologies are needed to enable the delivery and use of diverse teaching and learning formats by educational institutions independent of time and place. The aim of this study is to analyze the effectiveness of different multidimensional formats in student teaching in surgical ENT medical anatomy. MATERIALS AND METHODS: During the summer semester 2022 and winter semester 2022/2023, the digital teaching and learning program was expanded by testing different visualization formats (3D glasses, cardboards, or VR glasses) with students in the context of a highly standardized surgical procedure, namely cochlear implantation. A pre- and post-intervention knowledge assessment was carried out in all groups, followed by an evaluation. RESULTS: Of 183 students, 91 students fully participated in the study. The post-intervention knowledge assessment showed a significant increase in correct answers regardless of visualization format. In a direct comparison, the operating room (OR) group answered correctly significantly more often than the cardboard group (pâ¯= 0.0424). The majority of students would like to see 3D teaching as an integral part of the teaching program (87.9%) and more streaming of live surgeries (93.4%). They see the use of the various technologies as a very good addition to conventional surgical teaching (72.5%), as good visualization (89%) increases retention (74.7%) and motivation (81.3%). CONCLUSION: Application and use of new visualization technologies in everyday clinical practice is a promising approach to expanding student training. Mobile, interactive, and personalized technical formats can be adapted to the learning behavior of students. Last but not least, the use of new media influences learning motivation. An expansion of digital teaching and learning formats can be expressly recommended on the basis of this study.
Assuntos
Instrução por Computador , Currículo , Otolaringologia , Otolaringologia/educação , Alemanha , Instrução por Computador/métodos , Humanos , Masculino , Feminino , Estudantes de Medicina , Avaliação Educacional , Anatomia/educação , Adulto Jovem , Ensino , AdultoRESUMO
BACKGROUND: Tympanic membrane perforations (TMPs) are a common complication of trauma and infection. Persisting perforations result from the unique location of the tympanic membrane. The wound is surrounded by air of the middle ear and the external auditory canal. The inadequate wound bed, growth factor, and blood supply lead to circular epithelialization of the perforation's edge and premature interruption of defect closure. Orthotopic animal models use mechanical or chemical tympanic membrane laceration to identify bioactive wound dressings and overcome premature epithelialization. However, all orthotopic models essentially lack repetitive visualization of the biomaterial-wound interface. Therefore, recent progress in 3D printing of customized wound dressings has not yet been transferred to the unique wound setup of the TMP. Here, we present a novel application for the mice dorsal skinfold chamber (DSC) with an epithelialized full-thickness defect as TMP model. METHODS: A circular 2-mm defect was cut into the extended dorsal skinfold using a biopsy punch. The skinfold was either perforated through both skin layers without prior preparation or perforated on 1 side, following resection of the opposing skin layer. In both groups, the wound was sealed with a coverslip or left unclosed (n = 4). All animals were examined for epithelialization of the edge (histology), size of the perforation (planimetry), neovascularization (repetitive intravital fluorescence microscopy), and inflammation (immunohistology). RESULTS: The edge of the perforation was overgrown by the cornified squamous epithelium in all pre-parations. Reduction in the perforation's size was enhanced by application of a coverslip. Microsurgical preparation before biopsy punch perforation and sealing with a coverslip enabled repetitive high-quality intravital fluorescence microscopy. However, spontaneous reduction of the perforation occurred frequently. Therefore, the direct biopsy punch perforation without microsurgical preparation was favorable: spontaneous reduction did not occur throughout 21 days. Moreover, the visualization of the neovascularization was sufficient in intravital microscopy. CONCLUSIONS: The DSC full-thickness defect is a valuable supplement to orthotopic TMP models. Repetitive intravital microscopy of the epithelialized edge enables investigation of the underlying pathophysiology during the transition from the inflammation to the proliferation phase of wound healing. Using established analysis procedures, the present model provides an effective platform for the screening of bioactive materials and transferring progress in tissue engineering to the special conditions of tympanic membrane wound healing.
Assuntos
Perfuração da Membrana Timpânica , Membrana Timpânica , Camundongos , Animais , Membrana Timpânica/metabolismo , Membrana Timpânica/patologia , Membrana Timpânica/cirurgia , Cicatrização/fisiologia , Perfuração da Membrana Timpânica/metabolismo , Perfuração da Membrana Timpânica/patologia , Pele , Inflamação/metabolismo , Inflamação/patologiaRESUMO
PURPOSE: A narrow bony internal auditory canal (IAC) may be associated with a hypoplastic cochlear nerve and poorer hearing performances after cochlear implantation. However, definitions for a narrow IAC vary widely and commonly, qualitative grading or two-dimensional measures are used to characterize a narrow IAC. We aimed to refine the definition of a narrow IAC by determining IAC volume in both control patients and patients with inner ear malformations (IEMs). METHODS: In this multicentric study, we included high-resolution CT (HRCT) scans of 128 temporal bones (85 with IEMs: cochlear aplasia, n = 11; common cavity, n = 2; cochlear hypoplasia type, n = 19; incomplete partition type I/III, n = 8/8; Mondini malformation, n = 16; enlarged vestibular aqueduct syndrome, n = 19; 45 controls). The IAC diameter was measured in the axial plane and the IAC volume was measured by semi-automatic segmentation and three-dimensional reconstruction. RESULTS: In controls, the mean IAC diameter was 5.5 mm (SD 1.1 mm) and the mean IAC volume was 175.3 mm3 (SD 52.6 mm3). Statistically significant differences in IAC volumes were found in cochlear aplasia (68.3 mm3, p < 0.0001), IPI (107.4 mm3, p = 0.04), and IPIII (277.5 mm3, p = 0.0004 mm3). Inter-rater reliability was higher in IAC volume than in IAC diameter (intraclass correlation coefficient 0.92 vs. 0.77). CONCLUSIONS: Volumetric measurement of IAC in cases of IEMs reduces measurement variability and may add to classifying IEMs. Since a hypoplastic IAC can be associated with a hypoplastic cochlear nerve and sensorineural hearing loss, radiologic assessment of the IAC is crucial in patients with severe sensorineural hearing loss undergoing cochlear implantation.
Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Cóclea/diagnóstico por imagem , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgiaRESUMO
OBJECTIVES: Enlarged vestibular aqueduct (EVA) is a common finding associated with inner ear malformations (IEM). However, uniform radiologic definitions for EVA are missing and various 2D-measurement methods to define EVA have been reported. This study evaluates VA volume in different types of IEM and compares 3D-reconstructed VA volume to 2D-measurements. METHODS: A total of 98 high-resolution CT (HRCT) data sets from temporal bones were analyzed (56 with IEM; [cochlear hypoplasia (CH; n = 18), incomplete partition type I (IPI; n = 12) and type II (IPII; n = 11) and EVA (n = 15)]; 42 controls). VA diameter was measured in axial images. VA volume was analyzed by software-based, semi-automatic segmentation and 3D-reconstruction. Differences in VA volume between the groups and associations between VA volume and VA diameter were assessed. Inter-rater-reliability (IRR) was assessed using the intra-class-correlation-coefficient (ICC). RESULTS: Larger VA volumes were found in IEM compared to controls. Significant differences in VA volume between patients with EVA and controls (p < 0.001) as well as between IPII and controls (p < 0.001) were found. VA diameter at the midpoint (VA midpoint) and at the operculum (VA operculum) correlated to VA volume in IPI (VA midpoint: r = 0.78, VA operculum: r = 0.91), in CH (VA midpoint: r = 0.59, VA operculum: r = 0.61), in EVA (VA midpoint: r = 0.55, VA operculum: r = 0.66) and in controls (VA midpoint: r = 0.36, VA operculum: r = 0.42). The highest IRR was found for VA volume (ICC = 0.90). CONCLUSIONS: The VA diameter may be an insufficient estimate of VA volume, since (1) measurement of VA diameter does not reliably correlate with VA volume and (2) VA diameter shows a lower IRR than VA volume. 3D-reconstruction and VA volumetry may add information in diagnosing EVA in cases with or without additional IEM.
Assuntos
Perda Auditiva Neurossensorial , Aqueduto Vestibular , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Aqueduto Vestibular/diagnóstico por imagem , Aqueduto Vestibular/anormalidades , CócleaRESUMO
BACKGROUND: Chronic otitis media (COM) can lead to significant impairment of health-related quality of life (HRQoL) due to symptoms such as otorrhea, pain, hearing loss, tinnitus, or dizziness. A systematic assessment of HRQoL in COM is becoming increasingly important as it complements (semi-)objective outcome parameters in clinical practice and research. HRQoL is measured by means of patient-reported outcome measures (PROMs). There are two disease-specific validated PROMs available for COM in German-the Chronic Otitis Media Outcome Test (COMOT-15) and the Zurich Chronic Middle Ear Inventory (ZCMEI-21)-which have become increasingly popular in recent years. OBJECTIVE: The purpose of this narrative review is to present the current state of research on measuring HRQoL in COM before and after surgical procedures. RESULTS AND CONCLUSION: Hearing is the most important factor influencing HRQoL in COM. Surgical procedures usually result in a clinically relevant improvement in HRQoL in COM with or without cholesteatoma. However, if cholesteatoma is present, its extent does not correlate with HRQoL. While HRQoL plays a secondary role in establishment of the indication for surgical therapy in COM with cholesteatoma, it plays an important role in terms of relative surgical indications, e.g., a symptomatic open mastoid cavity after resection of the posterior canal wall. We encourage the regular use of disease-specific PROMs preoperatively as well as during follow-up to assess HRQoL in COM in individual patients, in research, and in the context of quality monitoring.
Assuntos
Colesteatoma da Orelha Média , Otite Média , Humanos , Qualidade de Vida , Inquéritos e Questionários , Otite Média/diagnóstico , Otite Média/cirurgia , Otite Média/complicações , Orelha Média , Doença Crônica , Resultado do TratamentoRESUMO
OBJECTIVES: Knowledge about cochlear duct length (CDL) may assist electrode choice in cochlear implantation (CI). However, no gold standard for clinical applicable estimation of CDL exists. The aim of this study is (1) to determine the most reliable radiological imaging method and imaging processing software for measuring CDL from clinical routine imaging and (2) to accurately predict the insertion depth of the CI electrode. METHODS: Twenty human temporal bones were examined using different sectional imaging techniques (high-resolution computed tomography [HRCT] and cone beam computed tomography [CBCT]). CDL was measured using three methods: length estimation using (1) a dedicated preclinical 3D reconstruction software, (2) the established A-value method, and (3) a clinically approved otosurgical planning software. Temporal bones were implanted with a 31.5-mm CI electrode and measurements were compared to a reference based on the CI electrode insertion angle measured by radiographs in Stenvers projection (CDLreference). RESULTS: A mean cochlear coverage of 74% (SD 7.4%) was found. The CDLreference showed significant differences to each other method (p < 0.001). The strongest correlation to the CDLreference was found for the otosurgical planning software-based method obtained from HRCT (CDLSW-HRCT; r = 0.87, p < 0.001) and from CBCT (CDLSW-CBCT; r = 0.76, p < 0.001). Overall, CDL was underestimated by each applied method. The inter-rater reliability was fair for the CDL estimation based on 3D reconstruction from CBCT (CDL3D-CBCT; intra-class correlation coefficient [ICC] = 0.43), good for CDL estimation based on 3D reconstruction from HRCT (CDL3D-HRCT; ICC = 0.71), poor for CDL estimation based on the A-value method from HRCT (CDLA-HRCT; ICC = 0.29), and excellent for CDL estimation based on the A-value method from CBCT (CDLA-CBCT; ICC = 0.87) as well as for the CDLSW-HRCT (ICC = 0.94), CDLSW-CBCT (ICC = 0.94) and CDLreference (ICC = 0.87). CONCLUSIONS: All approaches would have led to an electrode choice of rather too short electrodes. Concerning treatment decisions based on CDL measurements, the otosurgical planning software-based method has to be recommended. The best inter-rater reliability was found for CDLA-CBCT, for CDLSW-HRCT, for CDLSW-CBCT, and for CDLreference. KEY POINTS: ⢠Clinically applicable calculations using high-resolution CT and cone beam CT underestimate the cochlear size. ⢠Ten percent of cochlear duct length need to be added to current calculations in order to predict the postoperative CI electrode position. ⢠The clinically approved otosurgical planning software-based method software is the most suitable to estimate the cochlear duct length and shows an excellent inter-rater reliability.
Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Ducto Coclear/cirurgia , Tomografia Computadorizada de Feixe Cônico , Eletrodos Implantados , Humanos , Reprodutibilidade dos Testes , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios XRESUMO
PURPOSE: Evaluating the current health state in chronic otitis media (COM), audiologic results are complemented by subjective outcomes, such as health-related quality of life (HRQoL). Two disease-specific instruments assessing HRQoL in COM in German-speaking patients exist, i.e., the chronic otitis media outcome test (COMOT-15) and the Zurich chronic middle ear inventory (ZCMEI-21). Since the psychometric properties of these questionnaires in a concurrent application are unknown, the aim of this study was to compare the COMOT-15 and the ZCMEI-21. METHODS: HRQoL was assessed in adult COM patients using the COMOT-15 and the ZCMEI-21. Psychometric properties were determined, including response distribution, concurrent validity, internal consistency, correlation to hearing and gender differences. RESULTS: In 173 patients (mean age 51.5 years), both questionnaires showed normally distributed scores without strong floor and ceiling effects. The total scores and subscores of both questionnaires exhibited satisfactory internal consistency (Cronbach's α 0.7-0.9) with the exception of the COMOT-15 hearing subscore (α = 0.94) and the ZCMEI-21 medical resource subscore (α = 0.66). Fair correlations between the air conduction pure-tone average and the total scores were found (COMOT-15: r = 0.36, p < 0.0001; ZCMEI-21: r = 0.34, p < 0.0001). CONCLUSION: In the first study comparing the COMOT-15 and the ZCMEI-21, both questionnaires exhibited satisfactory psychometric properties with several subtle differences. The COMOT-15 has a strong focus on hearing with a probably redundant content of the hearing subscore and may be suited for hearing-focused research questions. The ZCMEI-21 provides a comprehensive assessment of the COM symptom complex and may therefore also be used in research settings, where ear discharge, vertigo or pain should be covered.
Assuntos
Otite Média , Qualidade de Vida , Adulto , Doença Crônica , Humanos , Pessoa de Meia-Idade , Psicometria , Reprodutibilidade dos Testes , Inquéritos e QuestionáriosRESUMO
BACKGROUND: In medicine, the symptom of dizziness is one of the most common multidisciplinary causes of emergency medical presentation. Attending physicians are often faced with difficult decisions when evaluating patients with dizziness. A rapid differential diagnostic decision must be made during the initial examination. The goal of this study, was to develop a smartphone-based app that can diagnose and qualify nystagmus. The app should enable differentiation between acute emergencies such as strokes ("central vertigo") and vestibular disorders ("peripheral vertigo") using and recognizing or analyzing the accompanying symptom "nystagmus". MATERIALS AND METHODS: This prospective study was conducted at the Department of Otolaryngology, Head and Neck Surgery "Otto Körner", Rostock (Germany). The experimental study design consisted of two test runs and two control runs. In the two test runs, nystagmus was tracked and evaluated by caloric and optokinetic stimulation, respectively, through a custom-developed app. Sensitivity and correlation were calculated for the app's application performance and compared under different experimental conditions. RESULTS: The patient sample included twenty healthy participants with a mean age of 25.6 years (± 2.2 SD) who participated in the study. The overall sensitivity of detection of nystagmus averaged 82.14% in the optokinetic stimulation test trials. There is no correlation regarding specific subject data and sensitivity. CONCLUSIONS: The results of our experimental validation study show that a smartphone-based nystagmus app is a useful tool for vertigo diagnosis. The results of our analyses show that it is possible to diagnose nystagmus and determine shape or direction with the app.
Assuntos
Aplicativos Móveis , Nistagmo Patológico , Humanos , Adulto , Tontura/etiologia , Tontura/complicações , Smartphone , Estudos Prospectivos , Vertigem/etiologia , Nistagmo Patológico/diagnósticoRESUMO
BACKGROUND: Attendance teaching is the predominant teaching method at universities but needs to be questioned in the context of digital transformation. This study establishes and evaluates a method to accomplish electronic learning to supplement traditional attendance courses. MATERIALS AND METHODS: Surgery was transmitted in real-time conditions via an online live stream from the surgical theater. Visualization was transferred from a fully digital surgical microscope, an endoscope or an environmental camera in high definition quality. Students were able to participate at home from their personal computer. After following the surgery, they participated in an online-evaluation. RESULTS: A total of 65 students participated in the live stream. The majority of students (61.54%) indicated a significant subjective increase in knowledge after participation. The majority of students (53.85%) indicated that live surgeries should be offered as a permanent component in addition to classroom teaching. Likewise, a broader offer was desired by many students (63.08%). CONCLUSIONS: Live streaming of surgery is a promising approach as an alternative or supplement to traditional attendance teaching. An expansion of digital teaching can be explicitly supported on the basis of this study.
Assuntos
Aprendizagem , Estudantes , Humanos , EnsinoRESUMO
PURPOSE: Surgery is a standard therapy for tympanojugular paragangliomas (TJP). Maintaining the quality of life (QoL) requires functional preservation. The flexible CO2 laser allows contact-free tumor removal. This retrospective study compares the postoperative functional outcomes of TJP surgery with and without the flexible CO2 laser. METHODS: Between 2005 and 2019, 51 patients with TJP were surgically treated at a tertiary hospital. Until 2012, 17 patients received conventional surgery. Thereafter, the flexible laser was used in 34 patients. Tumor extend, pre- and postoperative cranial nerve function, and complications were compared between the groups. RESULTS: The cohort consisted of 33 class A and B tumors and 18 class C and D tumors. Preoperative embolization was performed in 17 cases. Class C/D TJP were usually removed via an infratemporal fossa type A approach. Gross total tumor removal was achieved in 14/18 class C/D tumors. 3/51 patients suffered from long-term partial or complete facial palsy. No differences in post-therapeutic cranial nerve function or complications were noted between the conventional and laser group. One recurrence was observed after complete tumor resection. CONCLUSION: The flexible CO2 laser was shown to be a safe and effective alternative to conventional bipolar cauterization, which is appreciated by the surgeon in these highly vascularized tumors. Both techniques allowed a high tumor control rate and good long-term results also from a functional point of view.
Assuntos
Paraganglioma , Qualidade de Vida , Humanos , Estudos Retrospectivos , Dióxido de Carbono , Paraganglioma/patologia , Paraganglioma/cirurgia , Nervos Cranianos/patologia , Resultado do TratamentoRESUMO
OBJECTIVE: In patients with cleft palate, a high incidence of chronic obstructive Eustachian tube dysfunction (ETD) is assumed after surgery. Consequently, an increased rate of retracted eardrum or cholesteatoma is expected. Even though no common standard for investigating ETD is available, the development of objective tests has increased during the past 10 years. This study aimed to investigate the incidence of persisting chronic obstructive ETD in adult patients with cleft palate surgically treated in early childhood by using a combination of diagnostic tools. METHODS: Adult participants with cleft palate repair in early childhood were invited for a follow-up examination and compared to a control group. Examination included tympanometry, tubomanometry, the Eustachian Tube Dysfunction Questionnaire (ETDQ-7), and the Eustachian Tube Score 7 (ETS-7). RESULTS: A total of 16 adult patients were re-examined after cleft palate surgery and compared to a control group of 40 healthy individuals. Significant differences were found in the median ETS7 (p < 0.0001) score but not in the median ETDQ7 (p = 0.09) score. Only 2 of the 32 investigated ears (6%) had pathologic scores in ETS7 and ETDQ7 (p = 0.09), whereas 5 (31%) cleft palate patients showed symptoms of chronic obstructive ETD according to ETS7. No patient had examination findings indicating a requirement for further treatment. CONCLUSION: By combining diagnostic tools for ETD, a lower rate of persisting obstructive ETD in adults after cleft palate surgery was found than previously reported. Successful surgical treatment of cleft palate seems to lead to physiological Eustachian tube function in long-term follow up.
Assuntos
Fissura Palatina , Otopatias , Tuba Auditiva , Testes de Impedância Acústica , Adulto , Pré-Escolar , Fissura Palatina/diagnóstico , Fissura Palatina/cirurgia , Otopatias/diagnóstico , Humanos , Inquéritos e QuestionáriosRESUMO
BACKGROUND: The development of technological innovations has not only changed social life and the healthcare system, but also affects medical education. The aim of this pilot study was to evaluate whether students, when observing a microsurgical procedure of the temporal bone, gain an additional understanding of the anatomical structures and surgical site when visualization is used that provides identical views for the surgeon and viewer in 3D. MATERIALS AND METHODS: During regular attendance tutorials, students were randomly assigned to three different groups: control group, 2D group, or 3D group. Evaluation questionnaires and intraoperative student annotation of the surgical view were used to assess the subjective didactic value of different visualization formats and resultant learning experiences for the students. RESULTS: A total of 47 students were included in the investigations during conventional attendance tutorials. The majority indicated a high added value of the 3D visualization in terms of method (70%) and vividness (80%) compared to the 2D group and self-study; 69% of the students fully agreed with the statement that 2D and 3D visualization increases learning motivation and is a very good way to improve recognition of anatomical topography and structures. CONCLUSION: New interactive visualization options in teaching promote learning efficiency and motivation among students. Especially 3D visualization and intraoperative annotation of the surgical view by the student is a useful didactic tool and increases the quality of clinical teaching. It supports the perception of anatomical topography and enables more focused surgical training.
Assuntos
Educação Médica , Estudantes de Medicina , Humanos , Aprendizagem , Motivação , Projetos Piloto , EstudantesRESUMO
INTRODUCTION: Surgical obliteration is the treatment of choice for symptomatic mastoid cavities. Various methods and materials are available. Allogeneic material is easily available but can lead to wound infections due to rejection, granulation and inflammatory reactions. Consequently, autologous material is often preferred due to its good biocompatibility. The aim of this study was to compare the long-term outcomes of patients after mastoid cavity obliteration with allogeneic and autologous material with regard to the occurrence of recurrent cholesteatoma, the number of revision surgeries and the impact of surgery on the health-related quality of life. METHODS: Patients who underwent mastoid cavity obliteration with an allogeneic material (hydroxyapatite matrix [HMM]) were retrospectively included in the study. In a prospective part, patients who underwent mastoid cavity obliteration with autologous reconstruction material (AutoM) were included. In addition to a detailed chart review, all patients underwent pure tone audiometry and completed the Zurich Chronic Middle Ear Inventory (ZCMEI-21) at the postoperative examination to assess health-related disease-specific quality of life. RESULTS: A total of 22 patients with a mean age of 56.9 (SD 18.7 years) receiving HMM (mean follow-up interval: 88.3 months [SD 21.9 months]) and 25 patients with a mean age of 52.4 years (SD 13.7 years) receiving AutoM (mean follow-up interval: 13.5 months [SD 9.5 months]) were included in the study. The revision-free rate for audiological indication after one year was 100% for HMM and 85% for AutoM. The recurrence-free rate at one year was 95% for HMM and 100% for AutoM. 55% of the patients with alloplastic material and 8% of the patients with autologous material required revision surgery due to ear discharge or recurrent cholesteatoma. The groups did not differ in terms of postoperative hearing outcome or postoperative quality of life. DISCUSSION: Obliteration of mastoid cavities is a surgical challenge. There was no relevant difference between the materials used in terms of recurrence rate, hearing and health-related quality of life within the 13.5-month observation period of both groups. The lack of subjective symptoms together with the high rate of recurrent cholesteatoma and revision indications emphasises the need for regular clinical follow-up including ear microscopy in chronic middle ear disease and strongly suggests regular follow-up examinations.
Assuntos
Colesteatoma da Orelha Média , Transplante de Células-Tronco Hematopoéticas , Colesteatoma da Orelha Média/cirurgia , Humanos , Processo Mastoide/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: German health policy has propagated an expansion of outpatient surgeries and procedures and initiated the discussion about this. Otorhinolaryngology, head and neck surgery offers opportunities to provide currently inpatient procedures on an outpatient basis. METHODS: The German Society of Otorhinolaryngology, Head and Neck Surgery, and the German Professional Association of Otorhinolaryngologists established working groups to assess and evaluate the ENT-specific aspects of shifting services to the outpatient setting. The working groups were given the task of developing and considering organizational, structural and personnel definitions of quality assurance. RECOMMENDATION: Facts were determined in detail, which exclude an ambulatory operation in the ENT-specialty. This was based on both surgery-related and patient-related facts. Finally, operations were named which can be performed as outpatient operations. DISCUSSION: An evaluation was performed from the ENT specialist's perspective. A prerequisite for outpatient treatment is a reorganization of remuneration. The current DRG and EBM system do not provide a satisfactory framework for this, and the EBM does not allow for the economic provision of surgical interventions in otorhinolaryngology, head and neck surgery. The development of an appropriate financing model is as imperative for a successful implementation as the integration and financing of further training of ENT physicians.
Assuntos
Procedimentos Cirúrgicos Ambulatórios , Otolaringologia , Humanos , Procedimentos Cirúrgicos Otorrinolaringológicos , Assistência Ambulatorial , AlemanhaRESUMO
PURPOSE: Different types of chronic middle ear disease (CMED) present with differing severity of single symptoms, such as discharge, vertigo or hearing loss, which impair health-related quality of life (HRQoL). Here, we aimed to (i) investigate characteristics of HRQoL and (ii) evaluate the association between HRQoL and hearing among different types of CMED. METHODS: In this prospective longitudinal cohort study, we included adult patients undergoing surgical treatment for CMED. Primary outcomes included HRQoL assessed by the Zurich Chronic Middle Ear Inventory (ZCMEI-21) and hearing assessed by pure-tone audiometry. RESULTS: In the included 108 patients (51% females), CMED were chronic otitis media (COM) with (n = 46) or without (n = 22) cholesteatoma, persistent mastoid cavity (with [n = 15] or without [n = 10] recurrent cholesteatoma), revision ossiculoplasty for hearing restoration (n = 14), and postinflammatory meatal fibrosis (n = 1). Preoperatively, the mean ZCMEI-21 score showed statistically significant differences among different types of CMED (p = 0.007) with persistent mastoid cavity without cholesteatoma exhibiting the highest score (34.1, SD 7.7) indicating poor HRQoL. At a mean follow-up period of 183 days, no statistically significant differences in the ZCMEI-21 scores among different types of CMED were observed (p = 0.67). CONCLUSION: This study objectifies differences in HRQoL among different types of CMED. In patients with indication for functional surgery only, e.g., persistent mastoid cavity without cholesteatoma, the worst HRQoL was observed. Yet, in these types of CMED, HRQoL guides decision for treatment. Moreover, differences in HRQoL among different types of CMED were not closely associated with hearing, but largely depended on other symptoms, such as discharge or vertigo.
Assuntos
Colesteatoma da Orelha Média , Otite Média , Adulto , Colesteatoma da Orelha Média/cirurgia , Doença Crônica , Orelha Média , Feminino , Humanos , Estudos Longitudinais , Masculino , Processo Mastoide , Otite Média/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento , TimpanoplastiaRESUMO
PURPOSE: To establish a standardized reporting system of cholesteatoma, the ChOLE classification has recently been introduced. We here aimed to systematically investigate the association between the ChOLE classification and (i) hearing, (ii) recidivism rate, and (iii) postoperative complications. These data may increase the utility of the ChOLE classification in clinical practice and research by stratifying patients according to expected outcomes or risks for complications. METHODS: In this prospective multicentric study, we included adult patients undergoing tympanomastoid surgery due to cholesteatoma. Main outcome measures included the association of the ChOLE classification system with (i) audiometric data including air conduction (AC) and bone conduction (BC) pure-tone average (PTA), and the air-bone gap (ABG), (ii) recidivism and complication. RESULTS: A total of 160 patients suffering from cholesteatoma were included. ChOLE stage distribution was stage I in 23 (14%), stage II in 128 (80%), and stage III in 9 (6%) patients. The ChOLE stage was associated with the postoperative AC PTA (p = 0.05) and the postoperative BC PTA (p = 0.02). Further, the status of the ossicular chain after surgery (ChOLE subdivision "O") was associated with both the postoperative ABG (p = 0.0001) and the postoperative AC PTA (p = 0.003). Moreover, we found an association between complications (ChOLE subdivision "L) and both the postoperative BC PTA (p = 0.04) and the postoperative ABG (p = 0.04). No association between the ChOLE stage was found to both cholesteatoma recidivism and surgical complications. CONCLUSION: The ChOLE classification is a new system to classify cholesteatomas. We provide evidence that hearing outcomes vary among different ChOLE stages. In particular, hearing outcomes are associated with the ChOLE subdivision "O" and "L". Thus, the ChOLE classification system has a predictive value regarding hearing outcomes.