Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur J Radiol ; 82(6): e255-61, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23414715

RESUMO

PURPOSE: Evaluate the diagnostic performance of contrast enhanced CT/PET (ceCT/PET) in the response assessment of patients with colorectal cancer liver metastases. METHODS: 33 ce CT/PET studies of 19 patients with colorectal liver metastases were prospectively evaluated. All of them, 13 (68.4%) were males and 6 (31.6%) females. Mean age and range were 63 [42-78]. All patients were treated with neoadjuvant chemotherapy. In all cases post-therapy diagnostic confirmation of liver lesions was obtained. A ce CT PET/was obtained 1h after the injection of 370 MBq of 18F-FDG. Metabolic and morphologic studies were evaluated by two blinded nuclear physicians and radiologists respectively to assess the location, size and suspected diagnosis of lesions (benign or malignant). A combined assessment of both techniques was performed. The final diagnosis was established by histopathology or clinical/radiological follow-up greater than 6 months. RESULTS: A total of 120 liver lesions were identified, 115 were malignant and 5 benign. From the malignant lesions, 105 were identified with the ceCT, 44 with the PET and 109 with ceCT/PET. All of the benign lesions were correctly classified with any of the three imaging techniques. The sensitivity of PET, ceCT and ceCT/PET were of 38%, 91% and 95% respectively and the specificity was 100% in all three of the diagnostic studies. CONCLUSION: Administration of intravenous contrast in the PET/CT is mandatory to evaluate treatment response rate of liver metastases due to the limitations of isolated metabolic images in these cases.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/terapia , Fluordesoxiglucose F18 , Iopamidol/análogos & derivados , Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha , Resultado do Tratamento
2.
Ann Nucl Med ; 25(3): 197-203, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21188659

RESUMO

AIM: To evaluate the impact of radioguided occult lesion localization (ROLL) in the correct location and excision of malignant breast lesions, and analyze if these results are affected by the histology and tumor size. MATERIALS AND METHODS: A total of 105 patients with occult breast lesions were studied. The mean age was 55 years. An intralesional dose of 18.5 MBq of 99mTc-labeled macroaggregated human albumin (AMA) was administered using stereotaxic mammography or ultrasound. Surgical resection was carried out with the help of a gammadetector probe. In the histological study, disease-free margin was defined by a distance between the tumor lesion and the surgical margin of more than 1 mm. The possible influence of tumor histology and lesion diameter with respect to free/affected margins was analyzed. RESULTS: Correct radiotracer placement was achieved in 100/105 of the cases (95.2%). In the remaining 5 cases (4.8%), radiotracer placement was incorrect, with 2 of them being malignant lesions that were found by macroscopic inspection, and the other 3 having benign pathology. Among the malignant lesions (44 cases), correct placement of the radiotracer was achieved in 42 cases (95.5%). Of these 42 malignant lesions, in which the ROLL was correctly performed, free surgical margins were obtained in 24 cases (57.1%), while the other 18 (42.9%) had infiltrated surgical margins. The most common histological type among the malignant lesions was invasive ductal carcinoma (71.4%). The histological types with an increased frequency of infiltration of surgical margins were invasive and microinvasive cancer (94.4%). All the affected margins were in lesions greater than 10 mm, and the highest incidence was in those between 20 and 30 mm (55.5%). CONCLUSION: In our experience, the advantages of the ROLL technique are a precise localization of malignant breast lesions (95.5%) and an increased probability of a complete excision with free margins in more than one half of them. Nevertheless, special consideration should be taken when dealing with invasive and microinvasive cancers and in those exceeding 10 mm because of their higher incidence of infiltrated margins.


Assuntos
Biópsia/métodos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carga Tumoral , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Humanos , Mamografia , Pessoa de Meia-Idade , Cintilografia , Estudos Retrospectivos , Técnicas Estereotáxicas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa