Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 88(3): E67-73, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26526783

RESUMO

OBJECTIVES: In this study we sought to evaluate coverage and apposition of Synergy™ stent at 3 and 6 months after implantation. BACKGROUND: The Pt-Cr everolimus-eluting stent with abluminal bioabsorbable polymer (Synergy™) is a new generation drug-eluting stent with features potentially favoring an early healing process which could make safe a shorter period of dual antiplatelet-therapy treatment. METHODS: Prospective, two-centers study enrolling patients with similar lesions treated with Synergy™ stents undergoing examination with OCT at 3 and 6 months in the respective centers. Blinded analysis was done at a core lab. Co-primary endpoints were proportion of struts with coverage and with apposition at 3 and 6 months. RESULTS: Finally, 22 patients (30 stents) in the 3 months group and 20 patients (30 stents) in the 6 months group were included. There were no significant differences between groups regarding clinical, angiographic measurements, and procedural data. The rate of strut coverage was 94.5% at 3 months and 96.6% at 6 months (P < 0.001), the rates of apposition were 93.8% and 96.2%, respectively, (P < 0.001), the proportion of uncovered but apposed struts was 2.5% and 1.9% (P = 0.03) and the proportion of uncovered and malapposed struts was 3% and 1.8%, respectively (P < 0.001). The maximal area of malapposition related with uncovered struts was 0.43 ± 0.4 mm(2) at 3 months and 0.14 ± 0.2 mm(2) at 6 months (P = 0.001). CONCLUSIONS: The everolimus-eluting stent with absorbable polymer, Synergy™, is associated to a high degree of intimal coverage and apposition at 3 months after implantation with additional increase at 6 months. © 2015 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Tomografia de Coerência Óptica , Cicatrização/efeitos dos fármacos , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Espanha , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa