Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Opt Express ; 18(18): 18625-32, 2010 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-20940754

RESUMO

A clinical ultrasound scanner and 14 MHz linear array collected real-time photoacoustic images (PAI) during an injection of gold nanorods (GNRs) near the region of a mature PC-3 prostate tumor in mice implanted with a skin flap window chamber. Three dimensional spectroscopic PAI (690-900 nm) was also performed to investigate absorption changes near the tumor and enhance specific detection of GNRs. Whereas GNRs improved PAI contrast (+18 dB), the photoacoustic spectrum was consistent with the elevated near infrared absorption of GNRs. The versatile imaging platform potentially accelerates development of photoacoustic contrast agents and drug delivery for cancer imaging and therapy.


Assuntos
Diagnóstico por Imagem/métodos , Nanopartículas Metálicas/química , Microscopia/métodos , Neoplasias/patologia , Acústica , Animais , Meios de Contraste/farmacologia , Dermatologia/instrumentação , Dermatologia/métodos , Progressão da Doença , Sistemas de Liberação de Medicamentos , Ouro/química , Luz , Camundongos , Nanotecnologia/métodos , Ultrassonografia/métodos
2.
Phys Med Biol ; 58(1): N1-12, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23221479

RESUMO

Recent clinical studies have demonstrated that photoacoustic imaging (PAI) provides important diagnostic information during a routine breast exam for cancer. PAI enhances contrast between blood vessels and background tissue, which can help characterize suspicious lesions. However, most PAI systems are either not compatible with commercial ultrasound systems or inefficiently deliver light to the region of interest, effectively reducing the sensitivity of the technique. To address and potentially overcome these limitations, we developed an accessory for a standard linear ultrasound array that optimizes light delivery for PAI. The photoacoustic enabling device (PED) exploits an optically transparent acoustic reflector to help direct laser illumination to the region of interest. This study compares the PED with standard fiber bundle illumination in scattering and non-scattering media. In scattering media with the same incident fluence, the PED enhanced the photoacoustic signal by 18 dB at a depth of 5 mm and 6 dB at a depth of 20 mm. To demonstrate in vivo feasibility, we also used the device to image a mouse with a pancreatic tumor. The PED identified blood vessels at the periphery of the tumor, suggesting that PAI provides complementary contrast to standard pulse echo ultrasound. The PED is a simple and inexpensive solution that facilitates the translation of PAI technology to the clinic for routine screening of breast cancer.


Assuntos
Técnicas Fotoacústicas/instrumentação , Ultrassom/instrumentação , Animais , Linhagem Celular Tumoral , Humanos , Camundongos , Fenômenos Ópticos , Neoplasias Cutâneas/diagnóstico por imagem , Fatores de Tempo , Ultrassonografia
3.
Ann Biomed Eng ; 41(7): 1579-91, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23132151

RESUMO

To identify the orthotropic biomechanical behavior of arteries, researchers typically perform stretch-pressure-inflation tests on tube-form arteries or planar biaxial testing of splayed sections. We examined variations in finite element simulations (FESs) driven from planar or tubular testing of the same coronary arteries to determine what differences exist when picking one testing technique vs. another. Arteries were tested in tube-form first, then tested in planar-form, and fit to a Fung-type strain energy density function. Afterwards, arteries were modeled via finite element analysis looking at stress and displacement behavior in different scenarios (e.g., tube FESs with tube- or planar-driven constitutive models). When performing FESs of tube inflation from a planar-driven constitutive model, pressure-diameter results had an error of 12.3% compared to pressure-inflation data. Circumferential stresses were different between tube- and planar-driven pressure-inflation models by 50.4% with the planar-driven model having higher stresses. This reduced to 3.9% when rolling the sample to a tube first with planar-driven properties, then inflating with tubular-driven properties. Microstructure showed primarily axial orientation in the tubular and opening-angle configurations. There was a shift towards the circumferential direction upon flattening of 8.0°. There was also noticeable collagen uncrimping in the flattened tissue.


Assuntos
Vasos Coronários/fisiologia , Análise de Elementos Finitos , Resistência à Tração , Animais , Fenômenos Biomecânicos , Colágeno/fisiologia , Simulação por Computador , Elastina/fisiologia , Técnicas In Vitro , Reprodutibilidade dos Testes , Suínos
4.
Ophthalmic Surg Lasers Imaging ; 43(2): 143-51, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22230169

RESUMO

BACKGROUND AND OBJECTIVE: Traditional ultrasound imaging systems for ophthalmology employ slow, mechanical scanning of a single-element ultrasound transducer. The goal was to demonstrate rapid examination of the anterior and posterior segment with a three-dimensional (3D) commercial ultrasound system incorporating high-resolution linear probe arrays. MATERIALS AND METHODS: The 3D images of the porcine eye were generated in approximately 10 seconds by scanning one of two commercial linear arrays (25- and 50-MHz). Healthy enucleated pig eyes were compared with those with induced injury or placement of a foreign material (eg, metal). Rapid, volumetric imaging was also demonstrated in one human eye in vivo. RESULTS: The 50-MHz probe provided exquisite volumetric images of the anterior segment at a depth up to 15 mm and axial resolution of 30 µm. The 25-MHz probe provided a larger field of view (lateral X depth: 20 × 30 mm), sufficient for capturing the entire anterior and posterior segments of the pig eye, at a resolution of 60 µm. A 50-MHz scan through the human eyelid illustrated detailed structures of the Meibomian glands, cilia, cornea, and anterior segment back to the posterior capsule. CONCLUSION: The 3D system with its high-frequency ultrasound arrays, fast data acquisition, and volume rendering capability shows promise for investigating anterior and posterior structures of the eye.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico/instrumentação , Segmento Posterior do Olho/diagnóstico por imagem , Animais , Traumatismos Oculares/diagnóstico por imagem , Suínos , Transdutores , Ultrassonografia
5.
J Biomed Opt ; 16(2): 026012, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21361696

RESUMO

Understanding the tumor microenvironment is critical to characterizing how cancers operate and predicting their response to treatment. We describe a novel, high-resolution coregistered photoacoustic (PA) and pulse echo (PE) ultrasound system used to image the tumor microenvironment. Compared to traditional optical systems, the platform provides complementary contrast and important depth information. Three mice are implanted with a dorsal skin flap window chamber and injected with PC-3 prostate tumor cells transfected with green fluorescent protein. The ensuing tumor invasion is mapped during three weeks or more using simultaneous PA and PE imaging at 25 MHz, combined with optical and fluorescent techniques. Pulse echo imaging provides details of tumor structure and the surrounding environment with 100-µm(3) resolution. Tumor size increases dramatically with an average volumetric growth rate of 5.35 mm(3)/day, correlating well with 2-D fluorescent imaging (R = 0.97, p < 0.01). Photoacoustic imaging is able to track the underlying vascular network and identify hemorrhaging, while PA spectroscopy helps classify blood vessels according to their optical absorption spectrum, suggesting variation in blood oxygen saturation. Photoacoustic and PE imaging are safe, translational modalities that provide enhanced depth resolution and complementary contrast to track the tumor microenvironment, evaluate new cancer therapies, and develop molecular contrast agents in vivo.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Imageamento Tridimensional/instrumentação , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia Doppler/instrumentação , Animais , Linhagem Celular Tumoral , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Camundongos , Camundongos SCID , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa