Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Stroke Cerebrovasc Dis ; 32(2): 106876, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36470175

RESUMO

A persistent primitive trigeminal artery (PPTA) is a vessel remnant of carotid-vertebrobasilar anastomosis. The aneurysm at the bifurcation of the internal carotid artery (ICA) and PPTA tends to have a broad neck with the branch incorporated into the sac. Because PPTA supplies to the posterior circulation and branches off direct pontine perforators, PPTA preservation should always be considered when treating PPTA aneurysms to avoid ischemic complications.We report a case of the wide-neck ICA-PPTA aneurysm successfully treated with the PulseRider-assisted coil embolization, resulting in complete occlusion with PPTA patency. Relevant anatomy and endovascular strategy of the PPTA aneurysms are discussed.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/complicações , Embolização Terapêutica/efeitos adversos , Artéria Carótida Interna/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/terapia , Doenças das Artérias Carótidas/complicações , Artéria Basilar
2.
Neurosurg Rev ; 45(3): 2221-2230, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35066661

RESUMO

In the treatment of an intracranial aneurysm with the flow diverter, the combined use of coil embolization can help promote subsequent progressive thrombosis within the aneurysm sac and reduce the risk of delayed aneurysm rupture. This study retrospectively reviewed outcomes of patients who had undergone the Pipeline Embolization Device (PED) with adjunctive coil embolization (PED/coil) at a single center to determine its safety and efficiency. Patients with internal carotid artery aneurysms following an intradural component were selected for PED/coil between 2015 and 2020. All patients were premedicated with dual antiplatelet therapy of aspirin plus clopidogrel or prasugrel. A minimal number of PEDs were deployed, with coils inserted using a stent-jail technique, avoiding dense packing. A total of 46 aneurysms (43 patients; median dome size, 11.6 mm; median neck width, 6.3 mm) were treated with PED/coil. The median volume embolization ratio was 14.8%. The degree of angiographic filling at the 6-month and latest angiography showed complete occlusion in 60.5% (26/43) and 70.5% (31/44), respectively. Small (< 10 mm) aneurysms achieved a higher complete occlusion rate in the early period; a lower cumulative incidence of aneurysm occlusion was observed in large and giant (≥ 10 mm) aneurysms (P = .024). The median clinical follow-up was 22 months, and no aneurysm ruptures occurred. Favorable clinical outcomes were achieved, with permanent neurological morbidity of 4.7% and no mortality. PED/coil demonstrated a high angiographic occlusion rate at an early stage. Loosely packed coils are sufficient to obliterate aneurysms effectively.


Assuntos
Aneurisma Roto , Doenças das Artérias Carótidas , Embolização Terapêutica , Aneurisma Intracraniano , Aneurisma Roto/etiologia , Doenças das Artérias Carótidas/etiologia , Artéria Carótida Interna/cirurgia , Angiografia Cerebral , Embolização Terapêutica/métodos , Seguimentos , Humanos , Aneurisma Intracraniano/etiologia , Aneurisma Intracraniano/cirurgia , Japão/epidemiologia , Estudos Retrospectivos , Stents , Resultado do Tratamento
3.
J Neuroendovasc Ther ; 18(4): 119-125, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38721617

RESUMO

Objective: Intraorbital dural arteriovenous fistula (IO-dAVF) is a rare condition, and treatment options vary from case to case. We report a case of transarterial embolization (TAE) for IO-dAVF. Case Presentation: A 62-year-old male complained of gradually worsening pain, hyperemia, and visual impairment in the right eye. He did not exhibit diplopia or exophthalmos. Cerebral angiography revealed an arteriovenous fistula in the right orbit. The feeding arteries were the ophthalmic artery (OphA) and the artery of the superior orbital fissure (ASOF), with the superior ophthalmic vein (SOV) as the main draining vein. The venous pathway from the SOV was not clearly visible, and considering the risk of blindness with TAE from the OphA, TAE from the ASOF was performed. Onyx 18 was selected as the liquid embolic material and injected through a microcatheter placed in the internal maxillary artery. Occlusion up to the SOV was achieved, and the shunt flow completely disappeared. Normal blood flow in the OphA was maintained, hyperemia improved, and no complications were observed. Conclusion: In cases of IO-dAVF, when transvenous embolization is difficult to perform, TAE using Onyx from the vessel of the external carotid artery system may be preferred over OphA.

4.
Clin Neurol Neurosurg ; 237: 108133, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38340428

RESUMO

OBJECTIVE: Although consensus has been reached regarding the use of mechanical thrombectomy for acute large anterior circulation occlusion, its effectiveness in patients with posterior circulation occlusion remains unclear. This study aimed to establish the determining factors for good clinical outcomes of mechanical thrombectomy for posterior circulation occlusion. METHODS: We extracted cases of acute large vessel occlusion (LVO) in the posterior circulation from a database comprising 536 patients who underwent mechanical thrombectomy at our hospital between April 2015 and March 2021. RESULTS: Fifty-two patients who underwent mechanical thrombectomy for LVO in the posterior circulation were identified. Five patients with simultaneous occlusion of the anterior and posterior circulation were excluded; finally, 47 patients were included in this study. The median patient age was 78 years, and 36% of the patients were women. The median National Institutes of Health Stroke Scale (NIHSS) score on admission was 31, the median posterior circulation-Alberta Stroke Program Early Computed Tomography Score (pc-ASPECTS) was 8, and the median Basilar Artery on Computed Tomography Angiography (BATMAN) score was 6. The rate of good recanalization (Thrombolysis in Cerebral Infarction scale grades 2b and 3) was 96%, and a good prognosis (modified Rankin Scale score of 0-2 at 90 days) was achieved in 19 patients (40%). The median pc-ASPECTS was significantly higher in the good prognosis group than in the poor prognosis group (10 vs. 7; p = 0.007). The median NIHSS score at presentation was significantly lower in the good prognosis group than in the poor prognosis group (17 vs. 34; p = 0.02). The median BATMAN score was significantly higher in the good prognosis group than in the poor prognosis group (8 vs. 3.5; p = 0.0002). Multivariate analysis showed that an NIHSS score ≦ 20 at presentation was the only independent factor for good prognoses. CONCLUSION: The prognosis of mechanical thrombectomy for posterior circulation LVO was better in patients with lower NIHSS scores at presentation.


Assuntos
Acidente Vascular Cerebral , Insuficiência Vertebrobasilar , Estados Unidos , Humanos , Feminino , Idoso , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/cirurgia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos
5.
J Neurosurg Case Lessons ; 7(16)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38621299

RESUMO

BACKGROUND: In mechanical thrombectomy for tandem occlusions in vertebrobasilar stroke, distal emboli from the vertebral artery lesion should be prevented. However, no suitable embolic protection devices are currently available in the posterior circulation. Here, the authors describe the case of a vertebral artery lesion effectively treated with a closed-tip stent retriever as an embolic protection device in the posterior circulation. OBSERVATIONS: A 65-year-old male underwent mechanical thrombectomy for basilar artery occlusion, with tandem occlusion of the proximal vertebral artery. After basilar artery recanalization via the nonoccluded vertebral artery, a subsequent mechanical thrombectomy was performed for the occluded proximal vertebral artery. To prevent distal embolization of the basilar artery, an EmboTrap III stent retriever was deployed as an embolic protection device within the basilar artery to successfully capture the thrombus. LESSONS: A stent retriever with a closed-tip structure can effectively capture thrombi, making it a suitable distal embolic protection device in the posterior circulation.

6.
Interv Neuroradiol ; : 15910199231176709, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37218151

RESUMO

BACKGROUND: An exchange maneuver is useful for the delivery of devices to target vessels. However, hemorrhagic complications can occur due to vessel perforation during an exchange maneuver. In addition, the exchange is often challenging due to unfavorable anatomy. Center Wire is an exchange-length wire with a nondetachable stent that was developed to improve navigation and stability during exchange maneuvers. The aim of this study is to investigate the safety and efficacy of Center Wire of the anchor wire technique during neuroendovascular treatment. METHODS: Ten patients with intracranial aneurysms were treated after signing a Certified Review Board-approved consent. Anchor wire technique was used in all patients to navigate catheters to the target vessel for aneurysm treatment. RESULTS: Anchor wire technique was successfully applied in all 10 cases using Center Wire. One device-related incident of vasospasm occurred which was asymptomatic. No device-related dissection, perforation, or thromboembolic events occurred. One patient had intraoperative aneurysm rupture during coil placement which was treated immediately without clinical consequences. Two patients had postoperative ischemic strokes due to thrombotic occlusion of branches originating from the aneurysm which were unrelated to the device. CONCLUSIONS: This first-in-human trial of Center Wire demonstrated the safety and efficacy of the anchor wire technique for neuroendovascular treatment in a strictly regulated prospective registry trial.

7.
Heliyon ; 9(3): e14360, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36950603

RESUMO

Objectives: Flow diverter or stent implantation to intracranial target lesion requires large inner diameter microcatheter navigation. The exchange method using stiff long wire is often necessary if it is difficult to navigate over the regular guidewire. However, this method has an intrinsic risk of vessel damage and may cause severe complications. We investigated the safety and efficacy of a new device, the Stabilizer device for navigation in a first-in-human clinical trial under the Certified Review Board agreement. Materials and methods: The Stabilizer is a 320 cm length exchange wire with a stent for anchoring and is compatible with a 0.0165" microcatheter. The trial design is a prospective single-arm open-label registry. Inclusion criteria are elective flow diverter treatment or stent-assisted coiling, expected to be difficult to navigate a microcatheter with a regular micro guidewire, and obtained documented consent. The primary endpoint of the study was a hemorrhagic complication. Results: Five patients were enrolled in this trial. The median age is 52 years, ranges from 41 to 70, and all patients were female. Three aneurysms were located on the internal carotid artery, one on the vertebral artery, and one on the basilar artery. Basilar artery aneurysm was treated by stent-assisted coiling and others were treated by flow diverter deployment. All cases successfully navigate microcatheter for the treatment by the trial method using Stabilizer device without any adverse event. Conclusions: The results from this first-in-human consecutive five cases show the safety of the Stabilizer device in neuro-endovascular therapy for navigation of devices to the intracranial target lesion.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa