Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circulation ; 140(8): e483-e503, 2019 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-30586773

RESUMO

BACKGROUND: It is unclear whether physiologic pacing by either cardiac biventricular pacing (BiVP) or His bundle pacing (HisBP) may prevent adverse structural and functional consequences known to occur among some patients who receive right ventricular pacing (RVP). AIM: Our analysis sought to review existing literature to determine if BiVP and/or HisBP might prevent adverse remodeling and be associated with structural, functional, and clinical advantages compared with RVP among patients without severe left ventricular dysfunction (>35%) who required permanent pacing because of heart block. METHODS: A literature search was conducted using MEDLINE (through PubMed) and Embase to identify randomized trials and observational studies comparing the effects of BiVP or HisBP versus RVP on measurements of left ventricular dimensions, left ventricular ejection fraction (LVEF), heart failure functional classification, quality of life, 6-minute walk, hospitalizations, and mortality. Data from studies that met the appropriate population, intervention, comparator, and outcomes of interest were abstracted for meta-analysis. Studies that reported pooled outcomes among patients with LVEF both above and below 35% could not be included in the meta-analysis because of strict relationships with industry procedures that preclude retrieval of industry-retained unpublished data on the subset of patients with preserved left ventricular function. RESULTS: Evidence from 8 studies, including a total of 679 patients meeting the prespecified criteria for inclusion, was identified. Results were compared for BiVP versus RVP, HisBP versus RVP, and BiVP+HisBP versus RVP. Among patients who received physiologic pacing with either BiVP or HisBP, the LV end-diastolic and end-systolic volumes were significantly lower (mean duration of follow-up: 1.64 years; -2.77 mL [95% CI -4.37 to -1.1 mL]; P=0.001; and -7.09 mL [95% CI -11.27 to -2.91; P=0.0009) and LVEF remained preserved or increased (mean duration of follow-up: 1.57 years; 5.328% [95% CI: 2.86%-7.8%; P<0.0001). Data on clinical impact such as functional status and quality of life were not definitive. Data on hospitalizations were unavailable. There was no effect on mortality. Several studies stratified results by LVEF and found that patients with LVEF >35% but ≤52% were more likely to receive benefit from physiologic pacing. Patients with chronic atrial fibrillation who underwent atrioventricular node ablation and pacemaker implant demonstrated clear improvement in LVEF with BiVP or HisBP versus RVP. CONCLUSION: Among patients with LVEF >35%, the LVEF remained preserved or increased with either BiVP or HisBP compared with RVP. However, patient-centered clinical outcome improvement appears to be limited primarily to patients who have chronic atrial fibrillation with rapid ventricular response rates and have undergone atrioventricular node ablation.


Assuntos
Bradicardia/patologia , Doença do Sistema de Condução Cardíaco/patologia , Estimulação Cardíaca Artificial/métodos , Função Ventricular Esquerda/fisiologia , Fibrilação Atrial/complicações , Bradicardia/complicações , Bradicardia/terapia , Doença do Sistema de Condução Cardíaco/complicações , Doença do Sistema de Condução Cardíaco/terapia , Humanos , Guias de Prática Clínica como Assunto , Qualidade de Vida , Volume Sistólico
2.
Circulation ; 138(13): e392-e414, 2018 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-29084732

RESUMO

BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; P=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; P<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; P<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; P<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; P<0.001).


Assuntos
Cardiologia/normas , Morte Súbita Cardíaca/prevenção & controle , Guias de Prática Clínica como Assunto/normas , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Complexos Ventriculares Prematuros/terapia , American Heart Association , Consenso , Medicina Baseada em Evidências/normas , Humanos , Fatores de Risco , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Resultado do Tratamento , Estados Unidos , Fibrilação Ventricular/complicações , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Complexos Ventriculares Prematuros/complicações , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/mortalidade
3.
J Am Coll Cardiol ; 74(7): 988-1008, 2019 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-30412708

RESUMO

BACKGROUND: It is unclear whether physiologic pacing by either cardiac biventricular pacing (BiVP) or His bundle pacing (HisBP) may prevent adverse structural and functional consequences known to occur among some patients who receive right ventricular pacing (RVP). AIM: Our analysis sought to review existing literature to determine if BiVP and/or HisBP might prevent adverse remodeling and be associated with structural, functional, and clinical advantages compared with RVP among patients without severe left ventricular dysfunction (>35%) who required permanent pacing because of heart block. METHODS: A literature search was conducted using MEDLINE (through PubMed) and Embase to identify randomized trials and observational studies comparing the effects of BiVP or HisBP versus RVP on measurements of left ventricular dimensions, left ventricular ejection fraction (LVEF), heart failure functional classification, quality of life, 6-minute walk, hospitalizations, and mortality. Data from studies that met the appropriate population, intervention, comparator, and outcomes of interest were abstracted for meta-analysis. Studies that reported pooled outcomes among patients with LVEF both above and below 35% could not be included in the meta-analysis because of strict relationships with industry procedures that preclude retrieval of industry-retained unpublished data on the subset of patients with preserved left ventricular function. RESULTS: Evidence from 8 studies, including a total of 679 patients meeting the prespecified criteria for inclusion, was identified. Results were compared for BiVP versus RVP, HisBP versus RVP, and BiVP+HisBP versus RVP. Among patients who received physiologic pacing with either BiVP or HisBP, the LV end-diastolic and end-systolic volumes were significantly lower (mean duration of follow-up: 1.64 years; -2.77 mL [95% CI -4.37 to -1.1 mL]; p=0.001; and -7.09 mL [95% CI -11.27 to -2.91; p=0.0009) and LVEF remained preserved or increased (mean duration of follow-up: 1.57 years; 5.328% [95% CI: 2.86%-7.8%; p<0.0001). Data on clinical impact such as functional status and quality of life were not definitive. Data on hospitalizations were unavailable. There was no effect on mortality. Several studies stratified results by LVEF and found that patients with LVEF >35% but ≤52% were more likely to receive benefit from physiologic pacing. Patients with chronic atrial fibrillation who underwent atrioventricular node ablation and pacemaker implant demonstrated clear improvement in LVEF with BiVP or HisBP versus RVP. CONCLUSION: Among patients with LVEF >35%, the LVEF remained preserved or increased with either BiVP or HisBP compared with RVP. However, patient-centered clinical outcome improvement appears to be limited primarily to patients who have chronic atrial fibrillation with rapid ventricular response rates and have undergone atrioventricular node ablation.


Assuntos
Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Humanos , Volume Sistólico , Remodelação Ventricular
4.
Heart Rhythm ; 16(9): e280-e298, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30412776

RESUMO

BACKGROUND: It is unclear whether physiologic pacing by either cardiac biventricular pacing (BiVP) or His bundle pacing (HisBP) may prevent adverse structural and functional consequences known to occur among some patients who receive right ventricular pacing (RVP). AIM: Our analysis sought to review existing literature to determine if BiVP and/or HisBP might prevent adverse remodeling and be associated with structural, functional, and clinical advantages compared with RVP among patients without severe left ventricular dysfunction (>35%) who required permanent pacing because of heart block. METHODS: A literature search was conducted using MEDLINE (through PubMed) and Embase to identify randomized trials and observational studies comparing the effects of BiVP or HisBP versus RVP on measurements of left ventricular dimensions, left ventricular ejection fraction (LVEF), heart failure functional classification, quality of life, 6-minute walk, hospitalizations, and mortality. Data from studies that met the appropriate population, intervention, comparator, and outcomes of interest were abstracted for meta-analysis. Studies that reported pooled outcomes among patients with LVEF both above and below 35% could not be included in the meta-analysis because of strict relationships with industry procedures that preclude retrieval of industry-retained unpublished data on the subset of patients with preserved left ventricular function. RESULTS: Evidence from 8 studies, including a total of 679 patients meeting the prespecified criteria for inclusion, was identified. Results were compared for BiVP versus RVP, HisBP versus RVP, and BiVP+HisBP versus RVP. Among patients who received physiologic pacing with either BiVP or HisBP, the LV end-diastolic and end-systolic volumes were significantly lower (mean duration of follow-up: 1.64 years; -2.77 mL [95% CI -4.37 to -1.1 mL]; p=0.001; and -7.09 mL [95% CI -11.27 to -2.91; p=0.0009) and LVEF remained preserved or increased (mean duration of follow-up: 1.57 years; 5.328% [95% CI: 2.86%-7.8%; p<0.0001). Data on clinical impact such as functional status and quality of life were not definitive. Data on hospitalizations were unavailable. There was no effect on mortality. Several studies stratified results by LVEF and found that patients with LVEF >35% but ≤52% were more likely to receive benefit from physiologic pacing. Patients with chronic atrial fibrillation who underwent atrioventricular node ablation and pacemaker implant demonstrated clear improvement in LVEF with BiVP or HisBP versus RVP. CONCLUSION: Among patients with LVEF >35%, the LVEF remained preserved or increased with either BiVP or HisBP compared with RVP. However, patient-centered clinical outcome improvement appears to be limited primarily to patients who have chronic atrial fibrillation with rapid ventricular response rates and have undergone atrioventricular node ablation.


Assuntos
Bradicardia , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca , Sistema de Condução Cardíaco/fisiopatologia , Volume Sistólico , American Heart Association , Bradicardia/fisiopatologia , Bradicardia/terapia , Doença do Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração/fisiopatologia , Humanos , Guias de Prática Clínica como Assunto , Resultado do Tratamento , Estados Unidos , Remodelação Ventricular
5.
J Am Coll Cardiol ; 72(14): 1653-1676, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-29097297

RESUMO

BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; p=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; p<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; p<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; p<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; p<0.001).


Assuntos
Arritmias Cardíacas/complicações , Morte Súbita Cardíaca/prevenção & controle , Guias de Prática Clínica como Assunto , American Heart Association , Arritmias Cardíacas/terapia , Doenças Assintomáticas , Síndrome de Brugada/diagnóstico , Comorbidade , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Eletrocardiografia , Humanos , Prevenção Primária , Estados Unidos
6.
Heart Rhythm ; 15(10): e253-e274, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29097318

RESUMO

BACKGROUND: Although large randomized clinical trials have found that primary prevention use of an implantable cardioverter-defibrillator (ICD) improves survival in patients with cardiomyopathy and heart failure symptoms, patients who receive ICDs in practice are often older and have more comorbidities than patients who were enrolled in the clinical trials. In addition, there is a debate among clinicians on the usefulness of electrophysiological study for risk stratification of asymptomatic patients with Brugada syndrome. AIM: Our analysis has 2 objectives. First, to evaluate whether ventricular arrhythmias (VAs) induced with programmed electrostimulation in asymptomatic patients with Brugada syndrome identify a higher risk group that may require additional testing or therapies. Second, to evaluate whether implantation of an ICD is associated with a clinical benefit in older patients and patients with comorbidities who would otherwise benefit on the basis of left ventricular ejection fraction and heart failure symptoms. METHODS: Traditional statistical approaches were used to address 1) whether programmed ventricular stimulation identifies a higher-risk group in asymptomatic patients with Brugada syndrome and 2) whether ICD implantation for primary prevention is associated with improved outcomes in older patients (>75 years of age) and patients with significant comorbidities who would otherwise meet criteria for ICD implantation on the basis of symptoms or left ventricular function. RESULTS: Evidence from 6 studies of 1138 asymptomatic patients were identified. Brugada syndrome with inducible VA on electrophysiological study was identified in 390 (34.3%) patients. To minimize patient overlap, the primary analysis used 5 of the 6 studies and found an odds ratio of 2.3 (95% CI: 0.63-8.66; p=0.2) for major arrhythmic events (sustained VAs, sudden cardiac death, or appropriate ICD therapy) in asymptomatic patients with Brugada syndrome and inducible VA on electrophysiological study versus those without inducible VA. Ten studies were reviewed that evaluated ICD use in older patients and 4 studies that evaluated unique patient populations were identified. In our analysis, ICD implantation was associated with improved survival (overall hazard ratio: 0.75; 95% confidence interval: 0.67-0.83; p<0.001). Ten studies were identified that evaluated ICD use in patients with various comorbidities including renal disease, chronic obstructive pulmonary disease, atrial fibrillation, heart disease, and others. A random effects model demonstrated that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.72; 95% confidence interval: 0.65-0.79; p<0.0001), and a second "minimal overlap" analysis also found that ICD use was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.61-0.82; p<0.0001). In 5 studies that included data on renal dysfunction, ICD implantation was associated with reduced all-cause mortality (overall hazard ratio: 0.71; 95% confidence interval: 0.60-0.85; p<0.001).


Assuntos
American Heart Association , Cardiologia/normas , Morte Súbita Cardíaca/prevenção & controle , Guias de Prática Clínica como Assunto , Prevenção Primária/normas , Sociedades Médicas , Taquicardia Ventricular/terapia , Comitês Consultivos , Morte Súbita Cardíaca/etiologia , Gerenciamento Clínico , Humanos , Taquicardia Ventricular/complicações , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa