Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Perfusion ; 38(4): 872-875, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35262440

RESUMO

INTRODUCTION: Heart surgery can be associated with adverse ischemic brain events. CASE REPORT: Here, we describe two patients who presented extensive infarction of the corpus callosum and of other brain watershed areas following coronary artery bypass grafting (CABG) on extracorporeal circulation (ECC). DISCUSSION: Infarction of the corpus callosum is an extremely rare condition due to its abundant blood supply. Our findings are noteworthy since they diverge from classical brain watershed infarcts and from other cases of corpus callosum involvement. This suggests that in some cases, CABG surgery on ECC may be associated to a profound impairment of intracerebral circulation. However, it is also possible that the corpus callosum is particularly vulnerable to yet unknown metabolic modifications connected to ECC. CONCLUSIONS: Further studies are needed in order to investigate the complex response of brain circulation and metabolism during heart surgery with ECC.


Assuntos
Ponte de Artéria Coronária , Corpo Caloso , Humanos , Ponte de Artéria Coronária/efeitos adversos , Circulação Extracorpórea/efeitos adversos , Isquemia/etiologia , Infarto/etiologia
2.
J Cardiothorac Vasc Anesth ; 36(7): 1919-1926, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34906382

RESUMO

OBJECTIVE: Previous studies reported a poor outcome in patients with coronavirus 2019 (COVID-19) undergoing cardiac surgery. Complications most frequently described were respiratory failure, renal failure, and thromboembolic events. In their recent experience, the authors observed a very high incidence of bleeding complications. The purpose of the study was to investigate a possible significant correlation between perioperative COVID-19 infection and hemorrhagic complications compared to non-COVID-19 patients. DESIGN: Single-center, observational, retrospective, matched case-control (1:2) study involving patients who underwent open-heart cardiac surgery from February 2020 and March 2021 with positive perioperative diagnosis of COVID-19 infection, matched with patients without COVID-19 infection. SETTING: Cardiac surgery unit and intensive care unit of a university tertiary center in a metropolitan area. PARTICIPANTS: In the study period, 773 patients underwent cardiac surgery on cardiopulmonary bypass (CPB). Among them, 23 consecutive patients had perioperative diagnosis of COVID-19 infection (study group). These patients were compared with 46 corresponding controls (control group) that matched for age, sex, body mass index, and Society of Thoracic Surgeons score. INTERVENTIONS: Open-heart cardiac surgery on CPB. MEASUREMENTS AND MAIN RESULTS: In the study group, 2 patients (9%) died in the intensive care unit from severe respiratory failure, shock, and multiple organ failure. In the study group, patients showed a significantly higher incidence of bleeding complications (48% v 2%, p = 0.0001) and cases of surgical reexploration for bleeding (35% v 2%, p = 0.0001), a higher incidence of severe postoperative thrombocytopenia (39% v 6%, p = 0.0007), and a higher need of blood components transfusions (74% v 30%, p = 0.0006). Chest tubes blood loss and surgical hemostasis time were markedly prolonged (p = 0.02 and p = 0.003, respectively). CONCLUSIONS: A worrisome increased risk of early and late bleeding complications in COVID-19 patients was observed, and it should be considered when assessing the operative risk. CPB-related inflammatory reaction could exacerbate the deleterious effect of COVID-19 on the coagulation system and likely deviate it toward a hemorrhagic pattern.


Assuntos
COVID-19 , Procedimentos Cirúrgicos Cardíacos , Insuficiência Respiratória , COVID-19/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Estudos de Casos e Controles , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Insuficiência Respiratória/etiologia , Estudos Retrospectivos
3.
Eur Heart J Suppl ; 23(Suppl E): E99-E102, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34650365

RESUMO

Heart failure is a complex clinical syndrome associated with a high mortality and morbidity rate. Despite the extensive pharmacological armamentarium, a non-negligible percentage of patients develop advanced heart failure and require further therapies. In these circumstances, heart transplantation remains the treatment of choice, but the limited number of donors and the reduction of potential candidates have made necessary to develop new technologies. Since the 1980s, left ventricular assist devices (LVADs) have been introduced and have completely revolutionized the landscape of advanced heart failure treatments. This article has identified the categories of patients who can benefit from the implantation of an LVAD and summarized the new classifications. In addition, the main LVADs are described, analysing the results of the main clinical studies, with particular reference to adverse events. Although there is no perfect LVAD, a multidisciplinary team approach, dedicated to the treatment of advanced heart failure, can guide the choices on the best device to implant, in order to minimize complications and improve the patient's quality of life.

4.
Perfusion ; 36(7): 679-687, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34080484

RESUMO

INTRODUCTION: Minimally invasive aortic valve replacement (MIAVR) requires changes in cannulation strategy and cardiopulmonary bypass (CPB) management when compared to the conventional approach (CAVR). We aimed at evaluating if these differences could influence perfusion-related quality parameters and impair postoperative outcomes. METHODS: Overall, 339 consecutive patients underwent MIAVR or CAVR between 2014 and 2020 and were analyzed retrospectively. To account for baseline differences, a propensity-matching analysis was performed, obtaining two groups of 97 patients each. RESULTS: MIAVR group had longer CPB time [107 (95-120) vs 95 (86-105) min, p = .003] than CAVR group. Of note, average pump flow rate index [2.4 (2.2-2.5) vs 2.7 (2.4-2.8) l/min/m2, p = .004] was lower in the MIAVR group. Mean arterial pressure was 73 = 9 mmHg vs 62 = 11 mmHg for the MIAVR and CAVR group, respectively (p < .001). Cell-salvaged blood was most commonly used in the MIAVR group (25.8% vs 11.3%, p = .02). Finally, CPB temperature was 32.8°C (32.1-34.8) for MIAVR group vs 34.9°C (33.2-36.1) for the CAVR group (p = .02). Postoperative complications were similar between groups. CONCLUSIONS: In conclusion, despite differences in CPB parameters in patients undergoing CAVR and MIAVR, the incidences of adverse outcomes were similar. However, compared to CAVR, MIAVR was associated with shorter durations of mechanical ventilation and hospital stay as well as less transfusion of blood products.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Ponte Cardiopulmonar , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos , Resultado do Tratamento
5.
Int J Mol Sci ; 22(11)2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34200325

RESUMO

The SARS-CoV-2 infection determines the COVID-19 syndrome characterized, in the worst cases, by severe respiratory distress, pulmonary and cardiac fibrosis, inflammatory cytokine release, and immunosuppression. This condition has led to the death of about 2.15% of the total infected world population so far. Among survivors, the presence of the so-called persistent post-COVID-19 syndrome (PPCS) is a common finding. In COVID-19 survivors, PPCS presents one or more symptoms: fatigue, dyspnea, memory loss, sleep disorders, and difficulty concentrating. In this study, a cohort of 117 COVID-19 survivors (post-COVID-19) and 144 non-infected volunteers (COVID-19-free) was analyzed using pyrosequencing of defined CpG islands previously identified as suitable for biological age determination. The results show a consistent biological age increase in the post-COVID-19 population, determining a DeltaAge acceleration of 10.45 ± 7.29 years (+5.25 years above the range of normality) compared with 3.68 ± 8.17 years for the COVID-19-free population (p < 0.0001). A significant telomere shortening parallels this finding in the post-COVID-19 cohort compared with COVID-19-free subjects (p < 0.0001). Additionally, ACE2 expression was decreased in post-COVID-19 patients, compared with the COVID-19-free population, while DPP-4 did not change. In light of these observations, we hypothesize that some epigenetic alterations are associated with the post-COVID-19 condition, particularly in younger patients (< 60 years).


Assuntos
Envelhecimento/genética , COVID-19/genética , COVID-19/fisiopatologia , Ilhas de CpG , Encurtamento do Telômero , Telômero/metabolismo , Adulto , Idoso , Enzima de Conversão de Angiotensina 2/sangue , Biomarcadores , COVID-19/complicações , COVID-19/etiologia , Metilação de DNA , Dipeptidil Peptidase 4/sangue , Epigenômica , Feminino , Sequenciamento de Nucleotídeos em Larga Escala , Interações entre Hospedeiro e Microrganismos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Sobreviventes , Síndrome de COVID-19 Pós-Aguda
6.
J Heart Valve Dis ; 26(4): 372-379, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-29302935

RESUMO

BACKGROUND AND AIM OF THE STUDY: Management of patients with aortic regurgitation (AR) and severe impairment of left ventricular (LV) function characterized by an ejection fraction (EF) ≤35% is challenging. Conflicting results regarding perioperative and long-term survival of these patients have been reported. The study aim was to compare in-hospital outcomes and long-term survival of patients with AR and severe LV dysfunction versus moderate dysfunction (35% 70 years and NYHA class III/IV symptoms were predictive of survival. CONCLUSIONS: In-hospital and long-term survival was similar in patients with severe LV dysfunction and with preserved or moderately reduced LV function. Positive reverse LV remodelling and improved LV function was evident at the two-year echocardiographic follow up in these patients, who should not be denied aortic valve surgery.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Cidade de Roma , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Remodelação Ventricular
7.
J Card Surg ; 31(3): 147-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26785697

RESUMO

We report a patient with situs inversus who developed a large posterior interventricular septum pseudoaneurysm with a septal defect following a myocardial infarction. The ventricular septum was approached through the left ventricle and the entrance of the pseudoaneurysm was repaired with a strip of equine pericardium.


Assuntos
Anormalidades Múltiplas , Procedimentos Cirúrgicos Cardíacos/métodos , Dextrocardia , Comunicação Interventricular/etiologia , Comunicação Interventricular/cirurgia , Infarto do Miocárdio/complicações , Situs Inversus , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Animais , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/cirurgia , Septos Cardíacos/cirurgia , Ventrículos do Coração/cirurgia , Cavalos , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/transplante
8.
Int J Cardiol ; 410: 132218, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38815673

RESUMO

BACKGROUND: The possibility to resheath some transcatheter heart valves (THV) facilitates the optimization of self-expandable devices implantation. However, resheating manoeuvres (expecially when repeated) increase the interaction between the transcatheter prosthesis and the patient's tissues potentially causing side-effects. AIMS: To assess the clinical outcomes of resheathing at midterm follow-up with a focus on the safety of multiple resheathing. METHODS: This retrospective observational study included all consecutive patients who underwent TAVI with a self-expandable supra-annular THV between December 2018 and December 2022. Primary endpoint was a composite of cardiovascular (CV) mortality, neurological events, non-fatal acute myocardial infarction and CV rehospitalizations. All clinical endpoints were assessed according to VARC-3 criteria. RESULTS: 469 TAVI procedures with self-expandable supra-annular THV were included in the study. The attempt to resheath and the resheath manoeuvres number was prospectively recorded into an electronic database. Resheating was attempted in 253 (53.9%) cases; 1, 2 and ≥ 3 resheathing were performed in respectively 122 (26.0%), 63 (13.4%) and 68 (14.5%) procedures. At a median follow-up of 640 days (interquartile range 340-1033 days), the incidence of the primary endpoint did not differ between 0 vs. ≥1 (22.7 vs. 26.1%, LogRank p = 0.584) and < 3 vs. ≥3 resheathing groups (24.2 vs. 26.5% LogRank p = 0.963). Furthermore, no significant differences in the primary endpoint were observed between 0, 1-2 and ≥ 3 resheathing (p = 0.84). CONCLUSIONS: Our study found that resheathing of self-expandable THVs during TAVI did not result in worse clinical outcomes compared with no resheathing at mid-term follow-up. These results are independent from the number of resheathing, underling the safety of multiple resheathing in terms of peri-procedural and mid-term outcome. CONDENSED ABSTRACT: In this retrospective observational study of 469 patients undergoing transcatheter aortic valve implantation (TAVI) for symptomatic severe aortic stenosis with self-expanding valves, we investigated the influence of resheathing on mid-term clinical outcomes. Specifically, we focused on the safety of multiple resheathing procedures. Our findings revealed no significant impact of resheathing on medium-term outcomes. The primary endpoint, a composite of cardiovascular mortality, neurological events, non-fatal acute myocardial infarction, and cardiovascular rehospitalizations, did not show statistically significant differences between no resheathing, single resheathing and multiple resheathing groups. Our study suggests that resheathing, even when performed multiple times, does not appear to significantly affect clinical outcomes at mid-term follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Seguimentos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
9.
Braz J Cardiovasc Surg ; 39(2): e20230159, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426432

RESUMO

INTRODUCTION: Obese patients are at risk of complications after cardiac surgery. The aim of this study is to investigate safety and efficacy of a minimally invasive approach via upper sternotomy in this setting. METHODS: We retrospectively reviewed 203 obese patients who underwent isolated, elective aortic valve replacement between January 2014 and January 2023 - 106 with minimally invasive aortic valve replacement (MIAVR) and 97 with conventional aortic valve replacement (CAVR). To account for baseline differences, a propensity-matching analysis was performed obtaining two balanced groups of 91 patients each. RESULTS: The 30-day mortality rate was comparable between groups (1.1% MIAVR vs. 0% CAVR, P=0.99). MIAVR patients had faster extubation than CAVR patients (6 ± 2 vs. 9 ± 2 hours, P<0.01). Continuous positive airway pressure therapy was less common in the MIAVR than in the CAVR group (3.3% vs. 13.2%, P=0.03). Other postoperative complications did not differ significantly. Intensive care unit stay (1.8 ± 1.2 vs. 3.2 ± 1.4 days, P<0.01), but not hospital stay (6.7 ± 2.1 vs. 7.2 ± 1.9 days, P=0.09), was shorter for MIAVR than for CAVR patients. Follow-up survival was comparable (logrank P-value = 0.58). CONCLUSION: MIAVR via upper sternotomy has been shown to be a safe and effective option for obese patients. Respiratory outcome was promising with shorter mechanical ventilation time and reduced need for post-extubation support. The length of stay in the intensive care unit was reduced. These advantages might be important for the obese patient to whom minimally invasive surgery should not be denied.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Esternotomia/efeitos adversos , Obesidade/complicações , Obesidade/cirurgia , Tempo de Internação
10.
Eur J Heart Fail ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014551

RESUMO

AIMS: Lung ultrasound (LUS) is a sensitive tool to assess pulmonary congestion (PC). Few data are available on LUS-PC evaluation in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). The aim of this study was to assess the prevalence and prognostic impact of LUS-PC in patients with severe AS before and after TAVI. METHODS AND RESULTS: We designed a single-centre prospective study in patients referred for TAVI for severe AS (ClinicalTrials.gov identification number: NCT05024942). All patients underwent echocardiography and LUS (according to a simplified 8-zone scanning protocol) the day before and within 72 h after the procedure. The primary endpoint was the composite of all-cause mortality, hospitalization for heart failure and urgent medical visits for worsening dyspnoea at 12-month follow-up. A total of 127 patients were enrolled (mean age 81.1 ± 5.8 years; 54.3% female). Pre-TAVI LUS-PC was documented in 65 patients (51%). After TAVI, the prevalence of LUS-PC significantly decreased as compared to pre-TAVI evaluation, being documented in only 28 patients (22% vs. 51%, p < 0.001) with a median B-lines score of 4 (interquartile range [IQR] 0-11) versus 11 (IQR 6-19) pre-TAVI (p < 0.001). During a median follow-up of 12 (12-17) months, 25 patients (19.6%) met the composite endpoint. On multivariable Cox regression analysis, pre-TAVI LUS-PC was independently associated with cardiovascular events (hazard ratio 2.764, 95% confidence interval 1.114-6.857; p = 0.028). CONCLUSIONS: Lung ultrasonography reveals a high prevalence of PC in patients with severe AS undergoing TAVI, which is significantly reduced by the procedure. Pre-TAVI PC, measured by LUS, is an independent predictor of 1-year clinical outcome.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38775458

RESUMO

OBJECTIVES: Ascending aorta (AA) dilatation in patients with bicuspid aortic valve (AV) is related both to genetic and haemodynamic factors. The aim of this study is to compare late progression of AA dilatation in bicuspid AV patients undergoing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve implantation (TAVI). METHODS: Data of 189 consecutive patients who underwent AV replacement for severe bicuspid AV stenosis were prospectively collected. Patients who underwent SAVR were compared to patients who underwent TAVI. Indication to the procedure was validated by the institutional Heart Team. Aortic diameters were evaluated by transthoracic echocardiogram. Differences between preoperative and long-term follow-up AA diameters were compared in the 2 groups. RESULTS: Between January 2015 and December 2021, 143 (76%) patients underwent SAVR and 46 (24%) patients underwent TAVI. At 4.6 (standard deviation 1.7) years follow-up, patients in the TAVI group showed significantly lower survival (P = 0.00013) and event-free survival (P < 0.0001). AA diameter progression was lower in surgical compared to transcatheter patients, 0.95 (0.60, 1.30) vs 1.65 (0.67, 2.63) mm, P = 0.02. AA diameter progression indexed for body surface area and height was lower in the surgical group: 0.72 (0.38, 1.05) vs 1.05 (0.39, 1.71) mm/m2, P = 0.02, and 0.59 (0.36, 0.81) vs 1.11 (0.44, 1.78) mm/m, P = 0.001, respectively. At multivariable linear regression analysis transcatheter procedure, baseline aortic diameter and paravalvular leak were significantly associated with increased postoperative AA dilatation. CONCLUSIONS: Bicuspid AV patients who underwent SAVR, showed significantly less long-term AA diameter progression than patients who underwent transcatheter procedure.

12.
Am J Cardiol ; 224: 26-35, 2024 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-38844197

RESUMO

New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm3 (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulusright coronary cusp calcium >48 mm3 (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Marca-Passo Artificial , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Tomografia Computadorizada Multidetectores/métodos , Estudos Prospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Sistema de Registros
13.
Artigo em Inglês | MEDLINE | ID: mdl-38880697

RESUMO

AIMS: The valve-in-valve transcatheter-aortic-valve-implantation (VIV-TAVI) represents an emerging procedure for the treatment of degenerated aortic bio-prostheses, and the occurrence of patient-prosthesis mismatch (PPM) after VIV-TAVI might affect its clinical efficacy. This study aimed to test a multimodal imaging approach to predict PPM risk during the TAVI planning phase and assess its clinical predictivity in VIV-TAVI procedures. METHODS: Consecutive patients undergoing VIV-TAVI procedures at our Institution over 6 years were screened and those treated by self-expandable supra-annular valves were selected. The effective orifice area (EOA) was calculated with a hybrid Gorlin equation combining echocardiographic data with invasive hemodynamic assessment. Severe PPM was defined according to such original multimodality assessment as EOAi≤0.65 cm2/m2 (if BMI < 30 kg/m2) or < 0.55 cm2/m2 (if BMI ≥ 30 kg/m2). The primary endpoint was a composite of all-cause mortality and valve-related re-hospitalization during the clinical follow-up. RESULTS: A total of 40 VIV-TAVI was included in the analysis. According to the pre-specified multimodal imaging modality assessment, 18 patients (45.0 %) had severe PPM. Among all baseline clinical and anatomical characteristics, estimated glomerular filtration rate before VIV-TAVI (OR 0.872, 95%CI[0.765-0.994],p = 0.040), the echocardiographic pre-procedural ≥moderate AR (OR 0.023, 95%CI[0.001-0.964],p = 0.048), the MSCT-derived effective internal area (OR 0.958, 95%CI[0.919-0.999],p = 0.046) and the implantation depth (OR 2.050, 95%CI[1.028-4.086],p = 0.041) resulted as independent predictors of severe PPM at multivariable logistic analysis. At a mean follow-up of 630 days, patients with severe PPM showed a higher incidence of the primary endpoint (9.1%vs.44.4 %;p = 0.023). CONCLUSION: In VIV-TAVI using self-expandable supra-annular valves, a multimodal imaging approach might improve clinical outcome predicting severe PPM occurrence.

14.
J Cardiovasc Surg (Torino) ; 64(4): 437-442, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37401819

RESUMO

BACKGROUND: In patients undergoing mitral valve surgery, restrictive suture annuloplasty (De Vega) for less-than-severe functional tricuspid regurgitation has been proven to be safe and effective. The aim of this study is to determine whether the adjunct of the plication of the posterior tricuspid leaflet with the same running suture (bicuspidized De Vega or "De Kay") is equally safe and effective. METHODS: Single center, retrospective study on patients submitted to suture repair of the tricuspid valve during mitral valve surgery, with either conventional or De Kay, between January 2014 and December 2020. Comparison was based on degree of residual tricuspid valve regurgitation and right ventricular assessment at discharge. RESULTS: Over the course of the study period, 255 patients undergoing mitral valve surgery had a dilated (>40 mm or >20 mm/m2) tricuspid valve annulus, with less-than-severe tricuspid regurgitation. Conventional De Vega was employed in 166 patients (65.1%) and De Kay in the remaining 89 (34.9%). At discharge the adjunct of postero-septal commissure plication has similar outcomes to the classic De Vega repair. It seems to preserve right ventricular function. CONCLUSIONS: De Kay repair guarantees the same tricuspidal regurgitation reduction as compared with conventional De Vega early after surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Retrospectivos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Suturas , Resultado do Tratamento
15.
J Cardiovasc Surg (Torino) ; 64(3): 338-347, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37078984

RESUMO

BACKGROUND: The increasing use of biological substitutes for surgical aortic valve replacement (AVR), has led to the development of new bioprostheses with improved hemodynamics and expected durability. METHODS: In this observational retrospective two-center cohort study, two innovative bioprostheses, INSPIRIS Resilia and AVALUS were analyzed. We analyzed early and 2.4-year follow-up results in terms of safety, clinical outcome and hemodynamic performance. RESULTS: From November 2017 to February 2021, 148 patients underwent AVR with INSPIRIS Resilia (N.=74) or AVALUS (N.=74) bioprosthesis. The 30-day and mid-term mortality was comparable (1% vs. 3%, P=0.1 and 7% vs. 4%, P=0.4, respectively). Valve-related mortality was observed in one AVALUS patient. Three (4%) patients of the AVALUS group developed prosthetic endocarditis and two of them died after reoperation. No other cases of prosthetic endocarditis were observed. No cases of structural valve degeneration or significant paravalvular leak were detected at follow-up. Median follow-up peak pressure gradient was 21 vs. 23 mmHg (P=0.4) and the mean pressure gradient was 12 vs. 13 mmHg (P=0.9) for Inspiris and AVALUS, respectively. The effective orifice area (EOA) and indexed EOA were 1.5 cm2 vs. 1.4 cm2 (P=0.4) and 0.8 vs. 0.7 cm2/m2 (P=0.5), respectively. Indexed left ventricular mass regression was -33 vs. -52 g/m2 for the Inspiris and AVALUS groups, respectively, (R2-adjusted =0.14; P<0.01). CONCLUSIONS: INSPIRIS Resilia and AVALUS bioprostheses were reliable with comparable results in safety, clinical outcome and hemodynamic performance. After statistical adjustment, AVALUS was associated with better left ventricular mass reduction. Long-term follow-up would provide definitive comparative results.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hemodinâmica , Desenho de Prótese , Resultado do Tratamento
16.
Minerva Cardiol Angiol ; 71(2): 189-198, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35687315

RESUMO

BACKGROUND: Valvular heart disease (VHD) requires optimized outpatient management that is generally considered to be best delivered by a dedicated, multidisciplinary team (Heart Valve Clinic [HVC]). Although HVC is promoted by clinical guidelines and organized in many centers, real world outcome assessments are limited. Thus, we evaluated the performance, clinical and management outcomes during a 6-year experience with an original HVC model. METHODS: By interrogating the local database, 1047 consecutive patients admitted to the HVC from January 2015 to October 2020 were found. Management and mortality were checked for all patients. After 3 years of HVC activity, in order to improve appropriateness and efficiency, access priority criteria were introduced. Thus, the study population was divided in two period subgroups (before and after access criteria introduction) that were compared. RESULTS: A total of 1047 consecutive patients admitted to the HVC constituted the study population; 346 patients (33%) were recommended for invasive treatment. After a mean follow-up of 25.7±3.1 months, 37 patients (3.5%) died. When comparing study periods, statistically significant increase inpatients' complexity and VHD severity was noticed in Period 2, also translating into higher rate of referral to intervention (39.0% vs. 29.4% in Period 1; P=0.001). Finally, despite higher rate of elderly and frail patients, operative mortality was not jeopardized. CONCLUSIONS: The present study reports a comprehensive assessment of the characteristics and outcomes achieved through an original HVC model. Standardization of access criteria supports the HVC improvement.


Assuntos
Doenças das Valvas Cardíacas , Humanos , Idoso , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/epidemiologia , Valvas Cardíacas , Instituições de Assistência Ambulatorial , Encaminhamento e Consulta
17.
World J Cardiol ; 14(5): 297-306, 2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35702322

RESUMO

BACKGROUND: The use of pre-closure suture-based devices represents a widely access-site hemostasis technique in percutaneous transfemoral transcatheter-aortic-valve-replacement (TF-TAVR); yet this technique is associated with the risk of a device failure that may result in clinically relevant residual bleeding. Thus, a bailout intervention is needed. So far, the best management of pre-closure device failure has not been recognized. AIM: To report the first clinical results obtained using a novel bailout hemostasis technique for patients with double suture-based vascular closure device failure in the setting of TF-TAVR. METHODS: We developed a "pledget-assisted hemostasis" technique to manage residual access-site bleeding. This consists of the insertion of a surgical, non-absorbable, polytetrafluoroethylene pledget over the sutures of the two ProGlide (Abbott Vascular, CA, United States). The ProGlide's knot-pushers are used to push down the pledget and the hand-made slipknot to seal the femoral artery leak. This technique was used as a bailout strategy in patients undergoing TF-TAVR with a systematic double pre-closure technique. Post-procedural access-site angiography was systematically performed. In-hospital complications were systematically detected and classified according to Valve Academic Research Consortium-2 criteria. RESULTS: Out of 136 consecutive patients who underwent TF-TAVR, 15 patients (mean age 80.0 ± 7.2 years, 66.7% female) with access-site bleeding after double pre-closure technique failure were treated by pledget-assisted hemostasis. In the majority of patients, 16F sheath was used (n = 12; 80%). In 2 cases (13%), a peripheral balloon was also inflated in the iliac artery to limit blood loss during pledget preparation. Angiography-confirmed hemostasis (primary efficacy endpoint) was achieved in all patients. After the procedure, 1 patient required blood transfusion (2 units), and no other bleeding or major ischemic complication was noticed. CONCLUSION: The "pledget assisted hemostasis" might be considered as a possible bailout technique to treat patients with residual access site bleeding. Further studies are needed to compare this approach with other bail-out techniques.

18.
ESC Heart Fail ; 9(3): 1721-1730, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35348288

RESUMO

AIMS: There are limited data about the intraprocedural haemodynamic study performed immediately before and after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis (AS). We aimed to evaluate the acute haemodynamic impact of TAVI in patients with severe AS and to investigate invasive and non-invasive parameters predicting all-cause mortality. METHODS AND RESULTS: A total of 245 consecutive AS patients (43% male, mean age 80.3 ± 7.3 years) undergoing TAVI were enrolled. Intraprocedural left heart catheterization (LHC) and echocardiogram before and after TAVI were performed. The clinical endpoint was the death for any cause. LHC after TAVI revealed significant changes in aortic and left ventricular (LV) pressures, including indexes of intrinsic myocardial contractility and diastolic function such as positive dP/dT (1128.9 ± 398.7 vs. 806.3 ± 247.2 mmHg/s, P Ë‚ 0.001) and negative dP/dT (1310.7 ± 431.1 vs. 1075.1 ± 440.8 mmHg/s, P Ë‚ 0.001). Post-TAVI echo showed a significant reduction in LV end-diastolic (P = 0.036) and end-systolic (P Ë‚ 0.001) diameters, improvement in LV ejection fraction (from 55 ± 12% to 57.2 ± 10.5%, P Ë‚ 0.001), and pulmonary artery systolic pressure (42.1 ± 14.2 vs. 33.1 ± 10.7 mmHg, P < 0.001). After a mean follow-up time interval of 24 months, 47 patients died. Post-TAVI significant aortic regurgitation at echocardiography was the only independent predictor of mortality (hazard ratio 5.592, confidence interval 1.932-16.184, P = 0.002). CONCLUSIONS: Left heart catheterization performed immediately before and after prosthesis release offers a unique insight in the assessment of LV adaptation to severe AS and the impact of TAVI on LV, catching changes in indexes of intrinsic contractility and myocardial relaxation. Aortic regurgitation assessed by echocardiography was the only independent predictor of mortality in patients undergoing TAVI.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Hemodinâmica , Humanos , Masculino , Resultado do Tratamento
19.
Front Cardiovasc Med ; 9: 895477, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35711347

RESUMO

Actually transcatheter aortic valve implantation within failed surgically bioprosthetic valves (VIV-TAVI) is an established procedure in patients at high risk for repeat surgical aortic valve intervention. Although less invasive than surgical reintervention, VIV-TAVI procedure offers potential challenges, such as higher rates of prosthesis-patient mismatch and coronary obstruction. Thus, optimal procedural planning plays an important role to minimize the risk of procedure complications. In this review, we describe the key points of a VIV-TAVI procedure to optimize outcomes and reduce the risk of procedure complications.

20.
J Am Heart Assoc ; 11(11): e024404, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35621200

RESUMO

Background A multidisciplinary approach might be pivotal for the management of patients with valvular heart disease (VHD), but clinical outcome data are lacking. Methods and Results At our institution, since 2014, internal guidelines recommended heart team consultations for patients with VHD. The clinical/echocardiographic characteristics, treatment recommendations, performed treatment, and early clinical outcomes of consecutive, hospitalized patients with VHD undergoing heart team evaluation were collected. Surgical risk was prospectively assessed by the EuroSCORE II and STS-PROM. The primary end point of the study was early mortality. A total of 1004 patients with VHD with high clinical complexity (mean age, 75 years; mean EuroSCORE II, 9.4%; mean STS-PROM, 5.6%; 48% ischemic heart disease; 29% chronic kidney disease, 9% oncologic/hematologic diseases) were enrolled. The heart team recommended an interventional treatment for 807 (80%) patients and conservative management for 197 (20%) patients. Management crossovers occurred in only 5% of patients. The recommended intervention was cardiac surgery for 230 (23%) patients, percutaneous treatment in 516 (51%) patients, and hybrid treatment in 61 (6%) patients. Early mortality occurred in 24 patients (2.4%) and was independently predicted by aortic stenosis, left ventricular ejection fraction, pulmonary artery systolic pressure, and conservative management recommendation. In patients referred to treatment, observed early mortality (1.7%) was significantly lower (P<0.001) than expected on the bases of both the STS-PROM (5.2%) and EuroSCORE II (9.7%). Conclusions Within the limitations of its single-center and observational design, the present study suggests that heart team-based management of patients with complex VHD is feasible and allows referral to a wide spectrum of interventions with promising early clinical results.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Idoso , Ecocardiografia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/terapia , Humanos , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa