Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38291925

RESUMO

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Médicos , Acidente Vascular Cerebral , Tromboembolia , Adulto , Humanos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Oclusão do Apêndice Atrial Esquerdo , Consenso , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Anticoagulantes/efeitos adversos , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Vitamina K , Apêndice Atrial/cirurgia , Resultado do Tratamento
2.
BMC Pulm Med ; 24(1): 233, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745282

RESUMO

BACKGROUND: Acute pulmonary embolism (PE) induces ventilation-perfusion mismatch and hypoxia and increases pulmonary pressure and right ventricular (RV) afterload, entailing potentially fatal RV failure within a short timeframe. Cardiopulmonary factors may respond differently to increased clot burden. We aimed to elucidate immediate cardiopulmonary responses during successive PE episodes in a porcine model. METHODS: This was a randomized, controlled, blinded study of repeated measurements. Twelve pigs were randomly assigned to receive sham procedures or consecutive PEs every 15 min until doubling of mean pulmonary pressure. Cardiopulmonary assessments were conducted at 1, 2, 5, and 13 min after each PE using pressure-volume loops, invasive pressures, and arterial and mixed venous blood gas analyses. ANOVA and mixed-model statistical analyses were applied. RESULTS: Pulmonary pressures increased after the initial PE administration (p < 0.0001), with a higher pulmonary pressure change compared to pressure change observed after the following PEs. Conversely, RV arterial elastance and pulmonary vascular resistance was not increased after the first PE, but after three PEs an increase was observed (p = 0.0103 and p = 0.0015, respectively). RV dilatation occurred following initial PEs, while RV ejection fraction declined after the third PE (p = 0.004). RV coupling exhibited a decreasing trend from the first PE (p = 0.095), despite increased mechanical work (p = 0.003). Ventilatory variables displayed more incremental changes with successive PEs. CONCLUSION: In an experimental model of consecutive PE, RV afterload elevation and dysfunction manifested after the third PE, in contrast to pulmonary pressure that increased after the first PE. Ventilatory variables exhibited a more direct association with clot burden.


Assuntos
Modelos Animais de Doenças , Embolia Pulmonar , Resistência Vascular , Animais , Embolia Pulmonar/fisiopatologia , Suínos , Resistência Vascular/fisiologia , Distribuição Aleatória , Gasometria , Função Ventricular Direita/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Feminino , Masculino
3.
Eur Heart J ; 44(36): 3469-3477, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37279491

RESUMO

AIMS: Transcatheter closure of patent foramen ovale (PFO) is the recommended stroke prevention treatment in patients ≤60 years with cryptogenic ischemic stroke and PFO. Atrial fibrillation or flutter (AF) is a known potential procedure-related complication, but long-term risk of developing AF remains unknown. This paper studied the long-term risk of developing AF following PFO closure. METHODS AND RESULTS: A Danish nationwide cohort study was conducted. During 2008-2020, this study identified a PFO closure cohort, a PFO diagnosis cohort without PFO closure, and a general population comparison cohort matched 10:1 to the PFO closure cohort on age and sex. The outcome was first-time AF diagnosis. Risk of AF and multivariable-adjusted hazard ratio (HR) of the association between PFO closure or PFO diagnosis and AF were calculated. A total of 817 patients with PFO closure, 1224 with PFO diagnosis, and 8170 matched individuals were identified. The 5 year risk of AF was 7.8% [95% confidence interval (CI): 5.5-10] in the PFO closure cohort, 3.1% (95% CI: 2.0-4.2) in the PFO diagnosis cohort, and 1.2% (95% CI: 0.8-1.6) in the matched cohort. The HR of AF comparing PFO closure with PFO diagnosis was 2.3 (95% CI: 1.3-4.0) within the first 3 months and 0.7 (95% CI: 0.3-1.7) thereafter. The HR of AF comparing PFO closure with the matched cohort was 51 (95% CI: 21-125) within the first 3 months and 2.5 (95% CI: 1.2-5.0) thereafter. CONCLUSION: Patent foramen ovale closure was not associated with any substantial increased long-term risk of developing AF beyond the well-known procedure-related short-term risk.


Assuntos
Fibrilação Atrial , Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/etiologia , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Forame Oval Patente/complicações , Forame Oval Patente/epidemiologia , Forame Oval Patente/diagnóstico , Estudos de Coortes , Prevenção Secundária/métodos , Cateterismo Cardíaco/efeitos adversos , Dinamarca/epidemiologia , Resultado do Tratamento , Recidiva , Dispositivo para Oclusão Septal/efeitos adversos
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37584233

RESUMO

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Dispositivo para Oclusão Septal/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Acidente Vascular Cerebral/etiologia
5.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37440757

RESUMO

AIMS: Patients with atrial fibrillation who despite taking oral anti-coagulant therapy (OAT) suffer a stroke or systemic embolism (SSE) without vascular cause or who develop left atrial appendage (LAA) thrombus (LAAT) should be considered as having malignant LAA. The optimal treatment strategy to reduce SSE risk in such patients is unknown. The aim of the study is to investigate the diagnostic and therapeutic pathways for malignant LAA practiced in European cardiac centres. METHODS AND RESULTS: An 18-item online questionnaire on malignant LAA was disseminated by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee. A total of 196 physicians participated in the survey. There seems to be high confidence in transoesophageal echocardiography (TEE) imaging, considering LAAT diagnosis. Switching to another direct oral anti-coagulant (DOAC) is the preferred initial step for the treatment of malignant LAA followed by a switch to vitamin K antagonist (VKA), low-molecular-weight heparin, or continued/optimized DOAC dosage, whereas LAA closure is the last option. Left atrial appendage closure is a viable option in patients with embolic stroke despite OAT and no evidence of thrombus at TEE (empty LAA) after comprehensive diagnostic measures to exclude other sources of embolism. CONCLUSION: This EHRA survey provides a snapshot of the contemporary management of patients diagnosed with malignant LAA. Currently, the majority of patients are treated on an outpatient basis with either shifting from VKA to DOAC or from one DOAC to another. Left atrial appendage closure in this population seems to be reserved for patients with higher bleeding risk or complications of malignant LAA, such as stroke.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Embolia , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Anticoagulantes/uso terapêutico , Ecocardiografia Transesofagiana , Trombose/epidemiologia , Fibrinolíticos/uso terapêutico , Inquéritos e Questionários , Resultado do Tratamento
6.
Europace ; 25(3): 914-921, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734247

RESUMO

AIMS: The FLXibility Post-Approval Study collected data on unselected patients implanted with a WATCHMAN FLX in a commercial clinical setting. METHODS AND RESULTS: Patients were implanted with a WATCHMAN FLX per local standard of care, with a subsequent first follow-up visit from 45 to 120 days post-implant and a final follow-up at 1-year post-procedure. A Clinical Event Committee adjudicated all major adverse events and TEE/CT imaging results were adjudicated by a core laboratory. Among 300 patients enrolled at 17 centres in Europe, the mean age was 74.6 ± 8.0 years, mean CHA2DS2-VASc score was 4.3 ± 1.6, and 62.1% were male. The device was successfully implanted in 99.0% (297/300) of patients. The post-implant medication regimen was DAPT for 87.3% (262/300). At first follow-up, core-lab adjudicated complete seal was 88.2% (149/169), 9.5% (16/169) had leak <3 mm, 2.4 (4/169) had leak ≥3 mm to ≤5 mm, and 0% had >5 mm leak. At 1 year, 93.3% (280/300) had final follow-up; 60.5% of patients were on a single antiplatelet medication, 21.4% were on DAPT, 5.6% were on direct oral anticoagulation, and 12.1% were not taking any antiplatelet/anticoagulation medication. Adverse event rates through 1 year were: all-cause death 10.8% (32/295); CV/unexplained death 5.1% (15/295); disabling and non-disabling stroke each 1.0% (3/295, all non-fatal); pericardial effusion requiring surgery or pericardiocentesis 1.0% (3/295); and device-related thrombus 2.4% (7/295). CONCLUSION: The WATCHMAN FLX device had excellent procedural success rates, high LAA seal rates, and low rates of thromboembolic events in everyday clinical practice.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Inibidores da Agregação Plaquetária/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana
7.
Echocardiography ; 40(9): 925-931, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37477341

RESUMO

OBJECTIVES: In acute pulmonary embolism (PE), the right ventricle (RV) may dilate compromising left ventricular (LV) size, thereby increasing RV/LV ratio. End-diastolic RV/LV ratio is often used in PE risk stratification, though the cause of death is RV systolic failure. We aimed to confirm our pre-clinical observations of higher RV/LV ratio in systole compared to diastole in human patients with PE. METHODS: We blinded and independently analyzed echocardiograms from 606 patients with PE, evaluated by a Pulmonary Embolism Response Team. We measured RV/LV ratios in end-systole and end-diastole and fractional area change (FAC). Our primary outcome was a composite of 7-day clinical deterioration, treatment escalation or death. Secondary outcomes were 7-day and 30-day all-cause mortality. RESULTS: RV/LV ratio was higher in systole compared to diastole (median 1.010 [.812-1.256] vs. .975 [.843-1.149], p < .0001). RV/LV in systole and diastole were correlated (slope = 1.30 [95% CI 1.25-1.35], p < .0001 vs. slope = 1). RV/LV ratios in both systole and diastole were associated with the primary composite outcome but not with all-cause mortality. CONCLUSION: The RV/LV ratio is higher when measured in systole versus in diastole in patients with acute PE. The two approaches had similar associations with clinical outcomes, that is, it appears reasonable to measure RV/LV ratio in diastole.


Assuntos
Insuficiência Cardíaca , Embolia Pulmonar , Humanos , Ventrículos do Coração/diagnóstico por imagem , Diástole , Sístole , Embolia Pulmonar/diagnóstico por imagem , Ecocardiografia , Doença Aguda
8.
Cardiol Young ; 33(10): 1981-1991, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36468329

RESUMO

OBJECTIVES: Small, unrepaired atrial septal defects are considered a benign lesion with good prognosis. Recently, clinical and register-based studies discovered increased long-term mortality and morbidity. The nature of these findings is not fully understood. Therefore, MRI was performed to evaluate cardiac function at rest and during exercise. METHODS: Adults with open or spontaneously closed atrial septal defects and healthy, matched controls underwent MRI for evaluation of cardiac chamber volume. Quantitative flow scans measured blood flow in the ascending aorta and the proximal pulmonary artery at rest and during increasing supine exercise. RESULTS: In total, 15 open defects (39 ± 11 years) and 15 matched controls (38 ± 12 years) were included, along with 20 spontaneously closed (36 ± 13 years) and 20 controls (36 ± 11 years). Cardiac chamber volumes and flow measurements at rest were comparable between groups, as were heart rates and workloads during exercise. At maximal exercise, open defects reached 31% lower cardiac index and had 38% higher retrograde flow in the pulmonary artery than their controls, p < 0.01. Shunt ratio remained unchanged during exercise, 1.2 ± 0.2. Closed defects reached 18% lower cardiac index, p = 0.02, with comparable pulmonary retrograde flow. Maximal cardiac index was inversely correlated with increasing age for patients only. CONCLUSION: Adults with a small, open or spontaneously closed atrial septal defects exhibit markedly lower exercise capacity compared with healthy peers. Moreover, open defects exhibit higher retrograde flows with increasing exercise. Finally, increasing age is related to poorer results in patients but not healthy controls. Longitudinal studies are necessary in order to determine potential accelerated worsening of physical capacity along with age-related changes in patients.


Assuntos
Teste de Esforço , Comunicação Interatrial , Humanos , Adulto , Teste de Esforço/métodos , Débito Cardíaco/fisiologia , Imageamento por Ressonância Magnética , Nível de Saúde , Comunicação Interatrial/diagnóstico por imagem
9.
Am Heart J ; 243: 28-38, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34537184

RESUMO

BACKGROUND: The prevalence of atrial fibrillation (AF) is increasing globally, which is a major clinical and public health concern due to the 5-fold increased risk of stroke. Oral anticoagulation with novel oral anticoagulants (NOACs) is the current primary option for stroke prevention in patients with AF, although it increases the risk of major bleeding. Patients with prior ischemic cerebrovascular events are at particularly high risk of both recurrent ischemic events and major bleeding. Left atrial appendage occlusion (LAAO) provides an alternative option for stroke prevention in high-risk patients, however, with currently limited evidence. Thus, randomized trials comparing LAAO to NOACs are needed. OBJECTIVE: The Occlusion-AF trial is designed to assess whether LAAO is non-inferior to NOAC therapy for reduction of the combined endpoint of stroke, systemic embolism, major bleeding (Bleeding Academic Research Consortium ≥ 3) and all-cause mortality in patients with AF and a recent ischemic stroke or transient ischemic attack (TIA). METHODS AND ANALYSIS: Investigator-initiated multicenter, multinational, randomized open-label non-inferiority trial with blinded outcome evaluation (PROBE design). Patients with documented AF, and an ischemic stroke or TIA within 6 months will be eligible for enrollment. Major exclusion criteria are modified Rankin Scale > 3 at enrollment, glomerular filtration rate < 15 ml/min, and life-expectancy less than 2 years. A total of 750 patients will be randomized 1:1 to receive either a NOAC or LAAO using the Amplatzer Amulet (Abbott, MN, USA) or Watchman FLX (Boston Scientific, MN, USA) with subsequent life-long aspirin 75 mg daily. Follow-up will be based on in-office and telephone follow-up in combination with long-term follow-up (10 years) through national hospital discharge registries in the individual Nordic countries. The primary outcome will be a composite endpoint of stroke, systemic embolism, major bleeding (BARC ≥ 3) and all-cause mortality at 2-year follow-up. CONCLUSIONS: The Occlusion-AF trial is designed to compare LAAO to NOAC therapy for secondary stroke prevention in AF patients with a high risk of recurrent thromboembolic events, i.e. with previous ischemic stroke or TIA, and otherwise eligible for anticoagulation. The results are expected to contribute significantly to the understanding of the effects of LAAO compared to the standard contemporary pharmacological treatment in these patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/uso terapêutico , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Humanos , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 100(5): 801-809, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36153649

RESUMO

PURPOSE: The present article aims to compare a novel sizing chart based on both maximum and minimum diameters (novel MATRIX) with the current sizing recommendation instructions for use (IFU) based on the maximum diameter. BACKGROUND: Current IFU with the Amulet device are still based on the maximum left atrial appendage (LAA) diameter, which might lead to inappropriate oversizing, especially in elliptic appendages. METHODS: This was a retrospective analysis of patients undergoing LAA occlusion in two high-volume centers. Two hundred patients were included (100 patients with baseline cardiac computed tomography angiography [CCTA] and 100 with baseline 2D and 3D-transesophageal echocardiography [TEE]). The degree of concordance between the predicted device size recommendation and the actual device selection was the primary outcome. RESULTS: The novel MATRIX showed a higher level of concordance between the predicted and implanted device size, regardless of imaging modalities. CCTA showed the strongest, and 2D-TEE the weakest concordance between the predicted and implanted device for both MATRIX and IFU charts. The percentage of patients in whom the disagreement among the predicted and implanted device represented >1 size was higher when using the IFU chart. In elliptical LAA anatomies, the differences favoring the use of MATRIX compared to the IFU in terms of predicted/implanted agreement were higher. Finally, no significant differences in clinical or imaging endpoints were observed between the two different sizing charts. CONCLUSIONS: Incorporating both the LAA maximum and minimum diameters, as opposed to just maximum diameter, appears to improve sizing accuracy. The proposed MATRIX sizing chart offered a higher level of concordance between predicted and implanted device compared to the current IFU.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Ecocardiografia Transesofagiana
11.
Catheter Cardiovasc Interv ; 99(5): 1551-1557, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34773685

RESUMO

OBJECTIVES: To describe the occurrence of postprocedural atrial fibrillation (AF) among patients with cryptogenic stroke undergoing patent foramen ovale (PFO) closure in the REDUCE clinical study and analyze for potential risk factors for the development of postprocedural AF. BACKGROUND: AF is an adverse event that might potentially counterbalance the stroke prevention benefit from PFO closure. Data on AF after transcatheter PFO closure are sparse. METHODS: We evaluated data from patients having PFO closure (Gore HELEX or Gore Cardioform Septal Occluder) in the REDUCE clinical trial (n = 408) in at post hoc explorative analysis. Median follow-up was 5.0 years. RESULTS: AF occurred in 30 patients (7.4%) after PFO closure with a total of 34 AF events. Most were reported as non-serious (68%), detected within 45 days post-procedure (79%), and resolved within 2 weeks of onset (63%). One subject with AF had recurrent stroke. Postprocedural AF occurred more frequently among subjects with higher age and large device sizes. Male sex was the only independent predictor of postprocedural AF. We found no association between the type of occluder (HELEX or Gore Cardioform Septal Occluder) or PFO anatomical characteristics and post-procedural AF. CONCLUSION: In the REDUCE clinical study, postprocedural atrial fibrillation was mostly early onset, transient and with no later recurrence. Postprocedural AF occurred more frequently among patients with higher age and larger devices. Male sex was the only independent predictor of postprocedural AF.


Assuntos
Fibrilação Atrial , Cateterismo Cardíaco , Forame Oval Patente , Fibrilação Atrial/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Forame Oval Patente/terapia , Humanos , Masculino , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
12.
J Thromb Thrombolysis ; 53(2): 506-513, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34370168

RESUMO

Pulmonary embolism response teams (PERT) aim to improve treatment of acute pulmonary embolism (PE). PERT focus on intermediate- and high-risk PE patients, but recent multicenter studies show that low-risk PE patients compose one in five of all PERT cases. Conversely, not all intermediate- and high-risk PE patients elicit a PERT activation. The factors leading to PERT activations remain unknown. This study aims to describe the patient characteristics associated with PERT activation for low-risk PE patients and characteristics precluding PERT activation for intermediate/high-risk PE patients. We analysed data from all patients with confirmed PE diagnosed in the Massachusetts General Hospital Emergency Department from August 2013 to February 2017 and cross-referred these data with patients who received a PERT activation and patients who did not. Patients were stratified into low-risk or intermediate/high-risk PE. Univariate analyses were performed within each risk group comparing patients with a PERT activation and patients without. Fifteen percent (56/374) of low-risk PE patients triggered a PERT activation. Patient characteristics associated with PERT activation were: (1) vascular disease, (2) pulmonary diseases, (3) thrombophilia, (4) current use of anticoagulants, (5) central PE and (6) concurrent DVT. Thirty-five percent (110/283) of intermediate/high-risk PE patients did not elicit a PERT activation. Patient characteristics precluding a PERT activation were: (1) vascular disease, (2) malignancies and (3) asymptomatic presentation. Low-risk PE patients with PERT activations had more extensive clot burden, complex comorbidities, or had failed anticoagulation treatment. Intermediate/high-risk PE patients without PERT activations tended to have malignancies or vascular disease.


Assuntos
Equipe de Assistência ao Paciente , Embolia Pulmonar , Anticoagulantes , Humanos , Massachusetts/epidemiologia , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Fatores de Risco
13.
Crit Care Med ; 49(9): e891-e901, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33870917

RESUMO

OBJECTIVES: To investigate if oxygen could unload the right ventricle and improve right ventricle function in a porcine model mimicking intermediate-high risk acute pulmonary embolism. DESIGN: Controlled, blinded, animal study. SETTING: Tertiary university hospital, animal research laboratory. SUBJECTS: Female, Danish pigs (n = 16, approximately 60 kg). INTERVENTIONS: Acute autologous pulmonary embolism was induced until doubling of baseline mean pulmonary arterial pressure. Group 1 animals (n = 8) received increasing Fio2 (40%, 60%, and 100%) for time intervals of 15 minutes returning to atmospheric air between each level of Fio2. In group 2 (n = 8), the effects of Fio2 40% maintained over 75 minutes were studied. In both groups, pulmonary vasodilatation from inhaled nitric oxide (40 parts per million) was used as a positive control. MEASUREMENTS AND MAIN RESULTS: Effects were evaluated by biventricular pressure-volume loop recordings, right heart catheterization, and arterial and mixed venous blood gasses. Pulmonary embolism increased mean pulmonary arterial pressure from 15 ± 4 to 33 ± 6 mm Hg (p = 0.0002) and caused right ventricle dysfunction (p < 0.05) with troponin release (p < 0.0001). In group 1, increasing Fio2 lowered mean pulmonary arterial pressure (p < 0.0001) and pulmonary vascular resistance (p = 0.0056) and decreased right ventricle volumes (p = 0.0018) and right ventricle mechanical work (p = 0.034). Oxygenation was improved and pulmonary shunt was lowered (p < 0.0001). Maximal hemodynamic effects were seen at Fio2 40% with no additional benefit from higher fractions of oxygen. In group 2, the effects of Fio2 40% were persistent over 75 minutes. Supplemental oxygen showed the same pulmonary vasodilator efficacy as inhaled nitric oxide (40 parts per million). No adverse effects were observed. CONCLUSIONS: In a porcine model mimicking intermediate-high risk pulmonary embolism, oxygen therapy reduced right ventricle afterload and lowered right ventricle mechanical work. The effects were immediately present and persistent and were similar to inhaled nitric oxide. The intervention is easy and safe. The study motivates extended clinical evaluation of supplemental oxygen in acute pulmonary embolism.


Assuntos
Oxigenoterapia/normas , Embolia Pulmonar/fisiopatologia , Função Ventricular Direita/efeitos dos fármacos , Animais , Dinamarca , Oxigenoterapia/métodos , Oxigenoterapia/estatística & dados numéricos , Embolia Pulmonar/tratamento farmacológico , Suínos
14.
Catheter Cardiovasc Interv ; 97(7): E1025-E1032, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33580751

RESUMO

OBJECTIVES: To describe imaging assessment, procedural and follow-up outcome of patients undergoing left atrial appendage (LAA) occlusion (LAAO) using a "sandwich" technique. BACKGROUND: The presence of a LAA with chicken wing morphology constitutes a challenge that sometimes requires specific occlusion strategies like the "sandwich" technique. However, procedural and follow-up data focusing on this implanting strategy is scarce. METHODS: This multicenter study collected individual data from eight centers between 2012 and 2019. Consecutive patients with chicken-wing LAAs defined as an early (<20 mm from the ostium) and severe bend (>90°) who underwent LAAO with Amplatzer devices and using the "sandwich" technique were included in the analysis. RESULTS: Overall, 190 subjects were enrolled in the study. Procedures were done with the Amulet device (85%) and the Amplatzer Cardiac Plug (15%). Successful implantation was achieved in 99.5% with ≤1 partial recapture in 80% of cases. Single (46.2%) and dual antiplatelet therapy (39.4%) were the most used antithrombotic therapies after LAAO. In-hospital major adverse events rate was 1.5% with no deaths. One patient (0.5%) had cardiac tamponade requiring percutaneous drainage. With a mean follow-up of 19.6 ± 14.8 months, the mortality and stroke rates were 7.7%/year and 2.5%/year, respectively. Follow-up transesophageal echocardiography (TEE) at 2-3 months showed device-related thrombosis in 2.8% and peri-device leak ≥3 mm in 1.2% of patients. CONCLUSIONS: In a large series of patients with chicken wing LAA anatomies undergoing LAAO, the use of the "sandwich" technique was feasible and safe. Preprocedural imaging was a key-factor to determine specific measurements.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento
15.
Europace ; 23(2): 238-246, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33279979

RESUMO

AIMS: Left atrial appendage occlusion (LAAO) may be considered for patients with non-valvular atrial fibrillation (NVAF) and a relative/formal contraindication to anticoagulation. This study aimed to summarize the impact of aging on LAAO outcomes at short and long-term follow-up. METHODS AND RESULTS: We compared subjects aged <70, ≥70 and <80, and ≥80 years old in the prospective, multicentre Amplatzer™ Amulet™ Occluder Observational Study (Abbott, Plymouth, MN, USA). Serious adverse events (SAEs) were reported from implant through a 2-year post-LAAO visit and adjudicated by an independent clinical events committee. Overall, 1088 subjects were prospectively enrolled. There were 265 subjects (24.4%) <70 years old, 491 subjects (45.1%) ≥70 and <80 years old, and 332 subjects (30.5%) ≥80 years old, with the majority (≥80%) being contraindicated to anticoagulation. As expected, CHA2DS2-VASc and HAS-BLED Scores increased with age. Implant success was high (≥98.5%) across all groups, and the proportion of subjects with a procedure- or device-related SAE was similar between groups. At follow-up, the observed ischaemic stroke rate was not significantly different between groups, and corresponding risk reductions were 62, 56, and 85% when compared with predicted rates for subjects <70, ≥70 and <80, and ≥80 years old, respectively. Major bleeding and mortality rates increased with age, while the incidence of device-related thrombus tended to increase with age. CONCLUSIONS: Despite the increased risk for ischaemic stroke with increasing age in AF patients, LAAO reduced the risk for ischaemic stroke compared with the predicted rate across all age groups without differences in procedural SAEs.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Isquemia Encefálica , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Humanos , Estudos Prospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
16.
BMC Pulm Med ; 21(1): 72, 2021 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33639897

RESUMO

BACKGROUND: To investigate if acute pulmonary vasodilation by sildenafil improves right ventricular function in patients with acute intermediate-high risk pulmonary embolism (PE). METHODS: Single center, explorative trial. Patients with PE were randomized to a single oral dose of sildenafil 50 mg (n = 10) or placebo (n = 10) as add-on to conventional therapy. The time from hospital admission to study inclusion was 2.3 ± 0.7 days. Right ventricular function was evaluated immediately before and shortly after (0.5-1.5 h) randomization by right heart catheterization (RHC), trans-thoracic echocardiography (TTE), and cardiac magnetic resonance (CMR). The primary efficacy endpoint was cardiac index measured by CMR. RESULTS: Patients had acute intermediate-high risk PE verified by computed tomography pulmonary angiography, systolic blood pressure of 135 ± 18 (mean ± SD) mmHg, increased right ventricular/left ventricular ratio 1.1 ± 0.09 and increased troponin T 167 ± 144 ng/L. Sildenafil treatment did not improve cardiac index compared to baseline (0.02 ± 0.36 l/min/m2, p = 0.89) and neither did placebo (0.00 ± 0.34 l/min/m2, p = 0.97). Sildenafil lowered mean arterial blood pressure (- 19 ± 10 mmHg, p < 0.001) which was not observed in the placebo group (0 ± 9 mmHg, p = 0.97). CONCLUSION: A single oral dose of sildenafil 50 mg did not improve cardiac index but lowered systemic blood pressure in patients with acute intermediate-high risk PE. The time from PE to intervention, a small patient sample size and low pulmonary vascular resistance are limitations of this study that should be considered when interpreting the results. TRIAL REGISTRATION: The trial was retrospectively registered at www.clinicaltrials.gov (NCT04283240) February 2nd 2020, https://clinicaltrials.gov/ct2/show/NCT04283240?term=NCT04283240&draw=2&rank=1 .


Assuntos
Pressão Arterial/efeitos dos fármacos , Ventrículos do Coração/efeitos dos fármacos , Embolia Pulmonar/tratamento farmacológico , Citrato de Sildenafila/uso terapêutico , Vasodilatação/efeitos dos fármacos , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Citrato de Sildenafila/farmacologia , Resultado do Tratamento , Resistência Vascular/efeitos dos fármacos
17.
Eur Heart J ; 41(30): 2894-2901, 2020 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-32243499

RESUMO

AIMS: To evaluate the safety and efficacy of left atrial appendage occlusion (LAAO) with the Amplatzer™ Amulet™ occluder. METHODS AND RESULTS: Patients with atrial fibrillation eligible for LAAO were recruited to a prospective global study. Implant procedures were undertaken with echocardiographic guidance. Transoesophageal echocardiography (TOE) was undertaken 1-3 months post-LAAO. Implant and follow-up TOEs were evaluated by a CoreLab. The primary endpoint was a composite of ischaemic stroke and cardiovascular death at 2 years. Serious adverse events were adjudicated by an independent clinical events committee. A total of 1088 patients were enrolled, aged 75.2 ± 8.5 years; 64.5% were male. CHA2DS2-VASc and HAS-BLED scores were 4.2 ± 1.6 and 3.3 ± 1.1, respectively. A total of 71.7% had prior major bleeding, and 82.8% had contraindications to oral anticoagulants. Implant success was 99.1%. Major adverse events (≤7 days post-procedure) occurred in 4.0%, including death (0.3%), stroke (0.4%), major vascular (1.3%), and device embolization (0.2%). A total of 80.2% of patients were discharged on antiplatelet therapy alone. Peridevice flow was <3 mm in 98.4% at follow-up TOE. Device-related thrombus (DRT) was seen in 1.6% of cases. Cardiovascular death or ischaemic stroke occurred in 8.7% of patients at 2 years. The ischaemic stroke rate was 2.2%/year-a 67% reduction compared to the CHA2DS2-VASc predicted rate. Major bleeding (Bleeding Academic Research Consortium type ≥ 3) occurred at rates of 10.1%/year (year 1) and 4.0%/year (year 2). CONCLUSION: Following LAAO with the Amplatzer Amulet device, the ischaemic stroke rate was reduced by 67% compared to the predicted risk. Closure was complete in 98.4% of cases and DRT seen in only 1.6%.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Isquemia Encefálica , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
18.
Circulation ; 139(2): 269-285, 2019 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-30615500

RESUMO

The role of right ventricular (RV) fibrosis in pulmonary hypertension (PH) remains a subject of ongoing discussion. Alterations of the collagen network of the extracellular matrix may help prevent ventricular dilatation in the pressure-overloaded RV. At the same time, fibrosis impairs cardiac function, and a growing body of experimental data suggests that fibrosis plays a crucial role in the development of RV failure. In idiopathic pulmonary arterial hypertension and chronic thromboembolic PH, the RV is exposed to a ≈5 times increased afterload, which makes these conditions excellent models for studying the impact of pressure overload on RV structure. With this review, we present clinical evidence of RV fibrosis in idiopathic pulmonary arterial hypertension and chronic thromboembolic PH, explore the correlation between fibrosis and RV function, and discuss the clinical relevance of RV fibrosis in patients with PH. We postulate that RV fibrosis has a dual role in patients with pressure-overloaded RVs of idiopathic pulmonary arterial hypertension and chronic thromboembolic PH: as part of an adaptive response to prevent cardiomyocyte overstretch and to maintain RV shape for optimal function, and as part of a maladaptive response that increases diastolic stiffness, perturbs cardiomyocyte excitation-contraction coupling, and disrupts the coordination of myocardial contraction. Finally, we discuss potential novel therapeutic strategies and describe more sensitive techniques to quantify RV fibrosis, which may be used to clarify the causal relation between RV fibrosis and RV function in future research.


Assuntos
Insuficiência Cardíaca/etiologia , Ventrículos do Coração/fisiopatologia , Hipertensão Pulmonar/complicações , Hipertrofia Ventricular Direita/etiologia , Artéria Pulmonar/fisiopatologia , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita , Remodelação Ventricular , Adaptação Fisiológica , Animais , Pressão Arterial , Matriz Extracelular/patologia , Fibrose , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/patologia , Humanos , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Hipertrofia Ventricular Direita/patologia , Hipertrofia Ventricular Direita/fisiopatologia , Hipertrofia Ventricular Direita/terapia , Miocárdio/patologia , Prognóstico , Disfunção Ventricular Direita/patologia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
19.
Crit Care Med ; 48(12): e1306-e1312, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33060507

RESUMO

OBJECTIVES: To compare the hemodynamic effects of increased versus decreased preload in a porcine model of acute intermediate-risk pulmonary embolism. DESIGN: Randomized, controlled animal study. SETTING: Tertiary medical center, animal research laboratory. SUBJECTS: Female, Danish slaughter pigs (n = 22, ~ 60 kg). INTERVENTIONS: Acute pulmonary embolism was induced by large emboli made from clotting of autologous blood. Sixteen animals were randomized to either fluid loading (n = 8, isotonic saline, 1 L/hr for 2 hr) or diuretic treatment (n = 8, furosemide, 40 mg every 30 min, total 160 mg) and compared with a vehicle group (n = 6, no treatment). MEASUREMENTS AND MAIN RESULTS: Hemodynamics were evaluated at baseline, after pulmonary embolism and after each dose by biventricular pressure-volume loops, invasive pressures, diuretic output, respiratory variables, and blood analysis. Pulmonary embolism increased mean pulmonary arterial pressure (p < 0.0001), pulmonary vascular resistance (p = 0.008), right ventricular arterial elastance (p = 0.003), and right ventricular end-systolic volume (p = 0.020) while right ventricular stroke volume and right ventricular ejection fraction were decreased (p = 0.047 and p = 0.0003, respectively) compared with baseline. Fluid loading increased right ventricular end-diastolic volume (+31 ± 13 mL; p = 0.004), right ventricular stroke volume (+23 ± 10 mL; p = 0.009), cardiac output (+2,021 ± 956 mL; p = 0.002), and right ventricular ejection fraction (+7.6% ± 1.5%; p = 0.032), whereas pulmonary vascular resistance decreased (-202 ± 65 dynes; p = 0.020) compared with vehicle. Diuretic treatment decreased right ventricular end-diastolic volume (-84 ± 11 mL; p < 0.001), right ventricular stroke volume (-40 ± 6 mL; p = 0.001), cardiac output (-3,327 ± 451 mL; p = 0.005), and mean pulmonary arterial pressure (-7 ± 1 mm Hg; p < 0.001) and increased right ventricular end-systolic elastance (+0.72 ± 0.2 mm Hg/mL; p < 0.001) and systemic vascular resistance (+1,812 ± 767 dynes; p < 0.001) with no effects on mean arterial pressure. CONCLUSIONS: In a porcine model of acute intermediate-risk pulmonary embolism, fluid loading increased right ventricular preload and right ventricular stroke volume, whereas diuretics decreased right ventricular preload and right ventricular stroke volume without affecting mean arterial pressure.


Assuntos
Hemodinâmica , Embolia Pulmonar/fisiopatologia , Função Ventricular Direita , Animais , Pressão Sanguínea/fisiologia , Feminino , Hemodinâmica/fisiologia , Suínos , Resistência Vascular/fisiologia , Função Ventricular Direita/fisiologia
20.
Crit Care Med ; 48(4): e308-e315, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32205621

RESUMO

OBJECTIVES: We investigated whether the vasopressin-analog, terlipressin induces systemic vasoconstriction and pulmonary vasodilation in a porcine model of acute pulmonary embolism. DESIGN: Controlled, animal study. SETTING: Tertiary medical center research laboratory. SUBJECTS: Female pigs (n = 12, Cross of Land Race, Duroc, and Yorkshire ~ 60 kg). INTERVENTIONS: Acute pulmonary embolism was induced by administration of three large autologous emboli. Animals then received four increasing doses of either terlipressin (n = 6) or vehicle (n = 6). MEASUREMENTS AND MAIN RESULTS: Effects were evaluated in vivo at baseline, after pulmonary embolism and after each dose by invasive hemodynamic measures, transesophageal echocardiography, and blood analysis. Isolated pulmonary arteries were evaluated ex vivo in a myograph. Pulmonary embolism caused a four-fold increase in pulmonary vascular resistance (p < 0.0001) and a two-fold increase in mean pulmonary arterial pressure (p < 0.0001) compared with baseline. Terlipressin increased mean systemic blood pressure (28 ± 5 mm Hg; p < 0.0001) and systemic vascular resistance (1,320 ± 143 dynes; p < 0.0001) compared with vehicle. In the pulmonary circulation, terlipressin decreased mean pulmonary arterial pressure (-6.5 ± 1.8 mm Hg; p = 0.005) and tended to decrease pulmonary vascular resistance (-83 ± 33 dynes; p = 0.07). Terlipressin decreased cardiac output (-2.5 ± 0.5 L/min; p < 0.0001) and increased plasma lactate (2.7 ± 0.2 mmol/L; p < 0.0001), possibly indicating systemic hypoperfusion. A biomarker of cerebral ischemia, S100b, remained unchanged, suggesting preserved cerebral perfusion (0.17 ± 0.11 µg/L; p = 0.51). Ex vivo, terlipressin relaxed pulmonary and constricted mesenteric arteries. CONCLUSIONS: Terlipressin caused systemic vasoconstriction and pulmonary vasodilation in a porcine in vivo model of acute pulmonary embolism and vasorelaxation in isolated pulmonary arteries. Despite positive vascular effects, cardiac output declined and plasma lactate increased probably due to a predominantly systemic vasoconstrictor effect of terlipressin. These findings should warrant careful translation to the clinical setting and does not suggest routine use in acute pulmonary embolism.


Assuntos
Pressão Arterial/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Embolia Pulmonar/tratamento farmacológico , Resistência Vascular/efeitos dos fármacos , Vasoconstritores/efeitos adversos , Animais , Pressão Sanguínea/efeitos dos fármacos , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Feminino , Masculino , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/embriologia , Embolia Pulmonar/fisiopatologia , Suínos , Vasoconstritores/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa