Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Langenbecks Arch Surg ; 396(3): 337-43, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21170757

RESUMO

BACKGROUND: Intraoperative parathyroid hormone (ioPTH) is used during minimally invasive parathyroidectomy (MIP) to predict the success of surgery and should be accurate with a short turnaround time. MATERIAL AND METHOD: We developed an ioPTH point-of-care (POC) assay on Philips handheld magnotech system. Magnotech technology is based on magnetically controlled movement of superparamagnetic nanoparticles in stationary sample fluid. During first phase, intact-PTH is captured by magnetic particles coated with anti-N-terminal-PTH antibodies. Subsequently, magnetic particles are collected by magnetic forces at sensor surface coated with anti-C-terminal-PTH antibodies. Unbound/nonspecifically bound particles are pulled away from detection surface, using a second magnetic force. Amount of specifically bound particles is measured using a surface-sensitive optical imaging technique. RESULTS: ioPTH test could be performed with a turnaround time of less than 10 min and could detect low intact-PTH concentrations (picomolar). Integrated cartridge contains a blood separation filter and dry reagents for the assay. CONCLUSION: The next magnotech ioPTH assay will be the only POC test able to give accurate results in less than 10 min, using 25 µL of whole blood. Thanks to the ease-of-use, magnotech ioPTH could be performed in the operating theater by any member of surgical staff.


Assuntos
Monitorização Intraoperatória/instrumentação , Hormônio Paratireóideo/sangue , Paratireoidectomia/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Monitorização Intraoperatória/métodos , Hormônio Paratireóideo/análise , Sensibilidade e Especificidade , Fatores de Tempo
2.
Artigo em Inglês | MEDLINE | ID: mdl-16422424

RESUMO

We report here the use of finite element simulation and experiments to further explore the operation of the wafer transducer. We have separately modeled the emission and detection processes. In particular, we have calculated the wave velocities and the received voltage signals due to A0 and S0 modes at an output transducer as a function of pulse center frequency. These calculations include the effects of finite pulse width, pulse dispersion, and the detailed interaction between the piezoelectric element and the transmitting medium. We show that the received signals for A0 and S0 modes have maxima near the frequencies predicted from the previously published point-force model.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Modelos Teóricos , Transdutores , Ultrassonografia/instrumentação , Cerâmica/efeitos da radiação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
3.
Clin Chim Acta ; 411(11-12): 868-73, 2010 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-20211616

RESUMO

BACKGROUND: We present a prototype handheld device based on a newly developed optomagnetic technology for the sensitive detection of cardiac troponin I (cTnI) in a finger-prick blood sample with a turnaround time of 5 min. METHODS: The test was completed in a compact plastic disposable with on-board dry reagents and superparamagnetic nanoparticles. In our one-step assay, all reaction processes were precisely controlled using electromagnets positioned above and below the disposable. Nanoparticle labels (500 nm) bound to the sensor surface via a sandwich immunoassay were detected using the optical technique of frustrated total internal reflection. RESULTS: A calibration function measured in plasma demonstrates a limit of detection (mean of blank plus 3-fold the standard deviation) of 0.03 ng/mL cTnI. A linear regression analysis of the region 0.03-6.5 ng/mL yields a slope of 37+/-4, and a linear correlation coefficient of R2=0.98. The measuring range could be extended substantially to 100 ng/mL by simultaneously imaging a second spot with a lower antibody concentration. CONCLUSIONS: The combination of magnetic particles and their fine actuation with electromagnets permits the rapid and sensitive detection of cTnI. Because of the potential high analytical performance and ease-of-use of the test, it is well suited for demanding point-of-care diagnostic applications.


Assuntos
Técnicas Biossensoriais/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Troponina I/sangue , Técnicas Biossensoriais/métodos , Humanos , Magnetismo , Sensibilidade e Especificidade , Fatores de Tempo , Troponina I/análise
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa