Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 39: 102010, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39074602

RESUMO

BACKGROUND: This study aimed to assess the impact of dedicated cardiac protocol (DCP) on diagnostic accuracy of state-of-the-art digital [18F]-FDG-PET/CT in infective endocarditis (IE) and the intra-individual comparison of the performance with that of conventional whole-body approach (WBA) and to analyze the effects of the expertise level of the investigators. METHODS: 44 patients suspected for IE underwent digital-FDG-PET/CT after overnight fasting. Each three consultants and trainees reread PET images blinded to the examination approach and clinical information. Visual and semiquantitative analyses were performed. RESULTS: Digital-FDG-PET/CT with DCP revealed sensitivity, specificity, and accuracy of 89%, 93%, and 91% for native valve endocarditis (NVE) and 93%, 86%, and 91% for prosthetic valve endocarditis. Compared to WBA, substantial improvement of the diagnostic performance for NVE in DCP was evident, especially in trainees, but not as high compared to consultants. Digital-FDG-PET/CT enabled 79.5% reclassification of modified-Duke-Clinical-Criteria (mDC) with 34.1% upgrading and 45.4% downgrading. CONCLUSIONS: This study provides new data using state-of-the-art digital-FDG-PET/CT with DCP improving the diagnostic accuracy in challenging cases of possible IE, particularly in NVE, provided that the investigators involved have the necessary expertise. These findings may have a significant impact on IE-related morbidity, mortality, and patient's management and might be meaningful for updates on the prevailing opinion regarding the value of FDG PET/CT in NVE.


Assuntos
Endocardite , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Endocardite/diagnóstico por imagem , Idoso , Adulto , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Competência Clínica
2.
J Nucl Cardiol ; 29(5): 2254-2261, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33860458

RESUMO

Our previous study has demonstrated the feasibility of noninvasive imaging of fibroblast activation protein (FAP)-expression after myocardial infarction (MI) in MI-territory in a rat model with 68Ga-FAPI-04-PET. In the current extended clinical case, we sought to delineate cardiac uptake of 68Ga-FAPI-04 in a patient after MI with clinical indication for the evidence of fibroblast activation. Carcinoma patients without cardiac disease underwent 68Ga-FAPI-04-PET/CT as control. The patient with one-vessel disease underwent dynamic 68Ga-FAPI-04-cardiac-PET/CMR for 60 minutes. Correlation of cardiac 68Ga-FAPI-04 uptake with clinical findings, ECG, echocardiography, coronary-arteriography and enhanced cardiac-MRI with T1 MOLLI and ECV mapping were performed. No uptake was found in normal myocardium and in mature scar. A focal intense 68Ga-FAPI-04 uptake with continuous wash-out in the infarct territory of coronary occlusion correlating with T1 and ECV mapping was observed. The uptake of 68Ga-FAPI-04 extends beyond the actual infarcted area and overestimates the infarct size as confirmed by follow-up CMR.


Assuntos
Radioisótopos de Gálio , Infarto do Miocárdio , Animais , Fibroblastos/metabolismo , Fibroblastos/patologia , Proteínas de Membrana/metabolismo , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Quinolinas , Ratos
3.
Arthroscopy ; 36(7): 1928-1938, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32200064

RESUMO

PURPOSE: To evaluate the long-term clinical and radiologic outcomes of third-generation autologous chondrocyte implantation (ACI) for the treatment of focal cartilage defects of the knee. METHODS: Data capture was carried out between 2004 and 2018. Included were patients with cartilage defects of the knee joint with an International Cartilage Repair Society grade of III or higher treated with third-generation ACI who had a minimum follow-up period of 10 years. International Knee Documentation Committee scores and assessment of pain at rest and on movement using visual analog scale scores were captured preoperatively and at 6 months postoperatively, as well as annually thereafter. In addition, we performed magnetic resonance imaging examinations in 13 cases after 10 years. The MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) score was used to evaluate the ACI cartilage. RESULTS: A total of 54 patients met the inclusion criteria. Of these, 30 reached the 10-year follow-up point and were included in this assessment. At 10 years postoperatively, all clinical outcome parameters showed a statistically significant improvement compared with the preoperative situation, with a responder rate of 70%. The average MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) score after 10 years was 59.2 points (range, 20-100 points), and over 60% of the evaluated patients showed good integration of the implant at 10 years postoperatively. CONCLUSIONS: The clinical and radiologic findings of this study show that third-generation ACI is a suitable and effective option in the treatment of full-thickness cartilage defects of the knee. At 10 years after surgery, third-generation ACI shows stable results and leads to significant improvement in all clinical outcome parameters. Despite these results, revision surgery after third-generation ACI is common and was needed in 23% of patients in this study. LEVEL OF EVIDENCE: Level IV, therapeutic case series.


Assuntos
Doenças das Cartilagens/cirurgia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/cirurgia , Condrócitos/transplante , Articulação do Joelho/cirurgia , Procedimentos Ortopédicos , Adolescente , Adulto , Condrócitos/patologia , Características da Família , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Dor/cirurgia , Medidas de Resultados Relatados pelo Paciente , Período Pós-Operatório , Transplante Autólogo , Escala Visual Analógica , Adulto Jovem
4.
Eur Radiol ; 27(9): 3947-3955, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28168366

RESUMO

OBJECTIVE: To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. METHODS: Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. RESULTS: Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P < 0.001) and the TLR_12M rates (IW: 8 (13.3%); OC: 19 (27.5%); CC: 27 (54.0%); P < 0.001) differed significantly, as did the subgroup analyses (DBM: P = 0.05; RR: P = 0.003; HLP: P = 0.005; CAD: P = 0.02; localization: P < 0.001; calcification: P < 0.001), with the best patency for the IW stent and the highest TLR_12M for the CC stent. CONCLUSION: The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. KEY POINTS: • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.


Assuntos
Angioplastia/instrumentação , Arteriopatias Oclusivas/cirurgia , Artéria Femoral/cirurgia , Artéria Poplítea/cirurgia , Stents , Idoso , Ligas/uso terapêutico , Angioplastia/métodos , Angioplastia com Balão/métodos , Arteriopatias Oclusivas/patologia , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Doença Arterial Periférica/patologia , Doença Arterial Periférica/cirurgia , Desenho de Prótese , Reperfusão/métodos , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia
5.
J Comput Assist Tomogr ; 41(2): 254-262, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27636247

RESUMO

OBJECTIVE: The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. METHODS: Thirty-six patients receiving chest CT according to 3 protocols (120 kVp/noise index [NI], 60; 100 kVp/NI, 65; 80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity; the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. RESULTS: Diagnostic images (lesion conspicuity, 95%-100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. CONCLUSIONS: Model-based algorithm allows for submillisievert chest CT in average patients; the use of 100 kVp is recommended.


Assuntos
Peso Corporal , Modelos Teóricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sobrepeso , Estudos Prospectivos , Radiografia Torácica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
6.
Wound Repair Regen ; 22(1): 70-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24393154

RESUMO

The balance between matrix metalloproteinases and their endogenous tissue inhibitors (TIMPs) is an important component in effective wound healing. The biologic action of these proteins is linked in part to the stoichiometry of TIMP/matrix metalloproteinases/surface protein interactions. We recently described the effect of a glycosylphosphatidylinositol (GPI) anchored version of TIMP-1 on dermal fibroblast biology. Here, cell proliferation assays, in vitro wound healing, electrical wound, and impedance measurements were used to characterize effects of TIMP-1-GPI treatment on primary human epidermal keratinocytes. TIMP-1-GPI stimulated keratinocyte proliferation, as well as mobilization and migration. In parallel, it suppressed the migration and matrix secretion of dermal myofibroblasts, and reduced their secretion of active TGF-ß1. Topical application of TIMP-1-GPI in an in vivo excisional wound model increased the rate of wound healing. The agent positively influenced different aspects of wound healing depending on the cell type studied. TIMP-1-GPI counters potential negative effects of overactive myofibroblasts and enhances the mobilization and proliferation of keratinocytes essential for effective wound healing. The application of TIMP-1-GPI represents a novel and practical clinical solution for facilitating healing of difficult wounds.


Assuntos
Queimaduras por Corrente Elétrica/patologia , Glicosilfosfatidilinositóis/metabolismo , Queratinócitos/metabolismo , Engenharia Tecidual , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Cicatrização , Western Blotting , Queimaduras por Corrente Elétrica/metabolismo , Movimento Celular , Proliferação de Células , Células Cultivadas , Ensaio de Imunoadsorção Enzimática , Feminino , Fibroblastos/metabolismo , Regulação da Expressão Gênica , Humanos , Masculino , Receptores de Superfície Celular/metabolismo , Fator de Crescimento Transformador beta1/metabolismo
7.
Cancers (Basel) ; 16(15)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39123352

RESUMO

INTRODUCTION: Currently, the diagnosis of salivary gland tumors using imaging techniques is unreliable. METHODS: In this monocentric retrospective study, we examined patients who received a 68Ga-DOTATOC PET/CT and subsequently underwent a salivary gland tumor resection between 1 January 2010 and 31 December 2021. PET/CT image assessment was compared with somatostatin receptor (SSTR) expression and histology. RESULTS: Thirteen patients (five pleomorphic adenoma (PA) and eight other parotid lesions (OPL)) received a 68Ga-DOTATOC PET/CT. Imaging displayed strong focal tracer uptake in all PA except for one with strong tumor to background discrimination. PA revealed higher SUVmax, SUVmean, liver and blood pool quotients than those of Warthin tumors (WT) and of OPL. In comparison to the contralateral parotid, SUVmax (p = 0.02), SUVmean (p = 0.02), liver quotient (p = 0.03) and blood pool quotient (p = 0.03) were all significantly higher. In contrast, WT and OPL showed in relation to the contralateral parotid no significant differences of SUVmax (WT p = 0.79; OPL p = 0.11), SUVmean (WT p = 1.0; OPL p = 0.08), liver quotient (WT p = 0.5; OPL p = 0.08) and blood pool quotient (WT p = 0.8; OPL p = 0.19). Two PA and one granuloma were not available for examination. In the immunohistochemal analysis, all PA demonstrated the highest intensity of SSTR2 expression (grade 3). Furthermore, PA had a high percentage of cells expressing SSTR2 (20%, 80% and 55%). CONCLUSIONS: A strong tracer uptake in PA was shown in 68Ga-DOTATOC PET/CT. This may allow physicians to utilize radioligated somatostatin analogue PET CT/MR imaging to accurately diagnose PA. Additionally, it may be possible in the future to treat the PA with a noninvasive peptide receptor radionuclide therapy or with somatostatin analogues.

8.
J Clin Med ; 13(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38202276

RESUMO

Vascular graft/endograft infection (VGEI) is a serious complication after aortic surgery. This study investigates VGEI and patient characteristics, PET/CT quantification before surgical or conservative management of VGEI and post-intervention outcomes in order to identify patients who might benefit from such a procedure. PET standard uptake values (SUV) were quantitatively assessed and compared to a non-VGEI cohort. The primary endpoints were in-hospital mortality and aortic reintervention-free survival at six months. Ninety-three patients (75% male, 65 ± 10 years, 82% operated) were included. The initial operation was mainly for aneurysm (67.7%: 31% EVAR, 12% TEVAR, 57% open aortic repair). Thirty-two patients presented with fistulae. PET SUVTLR (target-to-liver ratio) showed 94% sensitivity and 89% specificity. Replacement included silver-coated Dacron (21.3%), pericardium (61.3%) and femoral vein (17.3%), yet the material did not influence the overall survival (p = 0.745). In-hospital mortality did not differ between operative and conservative treatment (19.7% vs. 17.6%, p = 0.84). At six months, 50% of the operated cohort survived without aortic reintervention. Short- and midterm morbidity and mortality remained high after aortic graft removal. Neither preoperative characteristics nor the material used for reconstruction influenced the overall survival, and, with limitations, both the in-hospital and midterm survival were similar between the surgically and conservatively managed patients.

9.
Cancers (Basel) ; 15(15)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37568733

RESUMO

Reliable preoperative diagnosis between salivary gland tumor entities is difficult. In this monocentric retrospective study, we examined the somatostatin receptor 2 (SSTR2) status of salivary gland tumors after salivary gland tumor resection via immunohistochemistry (IHC), and stains were compared in analogy to the HER2 mamma scale. A total of 42.3% of all pleomorphic adenoma (PA) tumors (42 of 99, 95% confidence interval 32.5-52.8%) demonstrated ≥20% of cells displaying the SSTR2 as compared to just 1% of all other tumors (1/160, 95% CI 0.02-3.4%). The other tumor was a neuroendocrine carcinoma. PA had a higher intensity of SSTR2 staining, with 90.9% staining ≥ an intensity of 2 (moderate). Tumors with an intensity of SSTR2 expression equal to or greater than 2 had an 89.9% likelihood of being a PA (95% CI: 82.2-95.0%, AUC: 0.928). Only one Warthin tumor demonstrated a 'strong' SSTR2 staining intensity. No Warthin tumor showed a percentage of cells staining for SSTR2 above ≥20%. This result demonstrates consistent and strong expression of SSTR2 in PAs as compared to Warthin tumors, which may allow physicians to utilize radioligand-somatostatin analog PET CT/MR imaging to diagnose the PA. SSTR2 positivity, if shown to be clinically relevant, may allow peptide receptor radionuclide therapy in the future.

10.
PLoS One ; 18(4): e0279323, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37058505

RESUMO

BACKGROUND: The differentiation of minimal-fat-or low-fat-angiomyolipomas from other renal lesions is clinically challenging in conventional computed tomography. In this work, we have assessed the potential of grating-based x-ray phase-contrast computed tomography (GBPC-CT) for visualization and quantitative differentiation of minimal-fat angiomyolipomas (mfAMLs) and oncocytomas from renal cell carcinomas (RCCs) on ex vivo renal samples. MATERIALS AND METHODS: Laboratory GBPC-CT was performed at 40 kVp on 28 ex vivo kidney specimens including five angiomyolipomas with three minimal-fat (mfAMLs) and two high-fat (hfAMLs) subtypes as well as three oncocytomas and 20 RCCs with eight clear cell (ccRCCs), seven papillary (pRCCs) and five chromophobe RCC (chrRCC) subtypes. Quantitative values of conventional Hounsfield units (HU) and phase-contrast Hounsfield units (HUp) were determined and histogram analysis was performed on GBPC-CT and grating-based attenuation-contrast computed tomography (GBAC-CT) slices for each specimen. For comparison, the same specimens were imaged at a 3T magnetic resonance imaging (MRI) scanner. RESULTS: We have successfully matched GBPC-CT images with clinical MRI and histology, as GBPC-CT presented with increased soft tissue contrast compared to absorption-based images. GBPC-CT images revealed a qualitative and quantitative difference between mfAML samples (58±4 HUp) and oncocytomas (44±10 HUp, p = 0.057) and RCCs (ccRCCs: 40±12 HUp, p = 0.012; pRCCs: 43±9 HUp, p = 0.017; chrRCCs: 40±7 HUp, p = 0.057) in contrast to corresponding laboratory attenuation-contrast CT and clinical MRI, although not all differences were statistically significant. Due to the heterogeneity and lower signal of oncocytomas, quantitative differentiation of the samples based on HUp or in combination with HUs was not possible. CONCLUSIONS: GBPC-CT allows quantitative differentiation of minimal-fat angiomyolipomas from pRCCs and ccRCCs in contrast to absorption-based imaging and clinical MRI.


Assuntos
Adenoma Oxífilo , Angiomiolipoma , Carcinoma de Células Renais , Neoplasias Renais , Humanos , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Angiomiolipoma/diagnóstico por imagem , Angiomiolipoma/patologia , Raios X , Tomografia Computadorizada por Raios X/métodos , Adenoma Oxífilo/diagnóstico por imagem , Diagnóstico Diferencial , Estudos Retrospectivos
11.
Biol Chem ; 393(12): 1463-70, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23667903

RESUMO

Tissue inhibitor of metalloproteinase 1 (TIMP-1) controls matrix metalloproteinase activity through 1:1stoichiometric binding. Human TIMP-1 fused to a glycosylphosphatidylinositol(GPI) anchor (TIMP-1 - GPI) shifts the activity of TIMP-1 from the extracellular matrix to the cell surface. TIMP-1 - GPI treated renal cell carcinoma cells show increased apoptosis and reduced proliferation.Transcriptomic profiling and regulatory pathway mapping were used to identify the potential mechanisms driving these effects. Significant changes in the DNA binding inhibitors, TGF- ß 1/SMAD and BMP pathways resulted from TIMP-1 - GPI treatment. These events were linked to reduced TGF- ß 1 signaling mediated by inhibition of proteolytic processing of latent TGF- ß 1 by TIMP-1 - GPI.


Assuntos
Carcinoma de Células Renais/terapia , Glicosilfosfatidilinositóis/uso terapêutico , Neoplasias Renais/terapia , Proteínas Recombinantes de Fusão/uso terapêutico , Inibidor Tecidual de Metaloproteinase-1/uso terapêutico , Fator de Crescimento Transformador beta1/metabolismo , Apoptose , Carcinoma de Células Renais/genética , Carcinoma de Células Renais/metabolismo , Carcinoma de Células Renais/patologia , Linhagem Celular Tumoral , Proliferação de Células , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Glicosilfosfatidilinositóis/genética , Humanos , Rim/citologia , Rim/metabolismo , Rim/patologia , Neoplasias Renais/genética , Neoplasias Renais/metabolismo , Neoplasias Renais/patologia , Metaloproteinases da Matriz/metabolismo , Análise de Sequência com Séries de Oligonucleotídeos , Proteínas Recombinantes de Fusão/genética , Transdução de Sinais , Inibidor Tecidual de Metaloproteinase-1/genética , Inibidor Tecidual de Metaloproteinase-1/metabolismo
12.
J Nucl Med ; 63(11): 1673-1676, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35241484

RESUMO

Vaccine-associated lymphadenopathy (VAL) is a common finding on 18F-FDG PET/CT examinations after coronavirus disease 2019 (COVID-19) vaccination. However, data regarding VAL on 18F-rhPSMA-7.3-ligand PET are currently lacking. This study assesses the prevalence, temporal response to vaccination, and characteristics of VAL. Methods: Two hundred thirty-three consecutive vaccinated and 41 unvaccinated patients with confirmed prostate cancer who underwent 18F-rhPSMA-7.3 PET/CT were retrospectively analyzed. Size and uptake of the axillary lymph nodes were measured. Ratios of SUVmax of ipsilateral to contralateral axillary lymph node (SUVratio) were determined. The characteristics of SUVratio in respect to the duration of PSMA avidity in the axillary lymph node after COVID-19 vaccination was analyzed. Results: The prevalence of VAL on 18F-rhPSMA-7.3 PET was 45%. Up to a period of 8 wk after the last COVID-19 vaccination, SUVratio was positive (2.05 ± 0.17). Thereafter, SUVratio dropped significantly (1.35 ± 0.09) and approached the value of unvaccinated group (1.1 ± 0.2). SUVratio of metastatic axillary lymph nodes was very high (>11) and can be easily detected visually or semiquantitatively. In 3 patients, we observed suspected development and consecutively confirmed involving metastasis of axillary lymph node with SUVratio between 4.0 to 6.6. Correlation between SUVratio and lymph node size (r = 0.93, P < 0.0001) and lymph node size and duration after vaccine (r = -0.88, P < 0.0008) was found. Conclusion: Increased uptake of the PSMA ligand 18F-rhPSMA-7.3 by axillary lymph nodes is common after COVID-19 vaccination and can persist for 8 wk. This finding should be considered in the interpretation of 18F-rhPSMA-7.3 PET/CT examinations.


Assuntos
COVID-19 , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Vacinas contra COVID-19 , Estudos Retrospectivos , Ligantes , Fluordesoxiglucose F18 , Linfonodos/patologia , Neoplasias da Próstata/patologia , Vacinação
13.
Sci Rep ; 12(1): 4726, 2022 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-35304544

RESUMO

Multi-frequency processing (MFP) leads to enhanced image quality (IQ) of radiographs. This study is to determine the effect of third generation MFP (M3) on IQ in comparison to standard second-generation MFP (M2). 20 cadavers were examined and post-processing of radiographs was performed with both M2 and M3. Three readers blinded to the MFP used for each image independently compared corresponding image pairs according to overall IQ and depiction of bony structures and soft tissue (+ 2: notably better > 0: equal > - 2: notably worse). A significant deviation of the median grade from grade 0 (equal) (p < 0.01) for each evaluator A, B and C speaks against an equal image quality of M2- and M3-images. M3-images were categorized with better grades (+ 1, + 2) in 87.7% for overall image quality, in 90.4% for soft tissue and 81.8% for bony structures. M3 images showed significant higher averaged SNR and CNR for all investigated lower extremities than that of M2 images (0.031 < p < 0.049). The newest generation of MFP leads to significantly better depiction of anatomical structures and overall image quality than in images processed with the preceding generation of MFP. This provides increased diagnostic accuracy and further decreased radiation exposure.


Assuntos
Osso e Ossos , Processamento de Imagem Assistida por Computador , Osso e Ossos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Radiografia
14.
Sci Rep ; 10(1): 9405, 2020 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-32523085

RESUMO

This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60 kV for all media in ATI and DFI, at 80 kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined.


Assuntos
Meios de Contraste/química , Radiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Microbolhas , Doses de Radiação , Raios X
15.
Insights Imaging ; 10(1): 20, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771029

RESUMO

Muscle injuries of the hip and thigh are a highly relevant issue in competitive sports imaging. The gold standard in diagnostic imaging of muscle injuries is magnetic resonance imaging (MRI). Radiologists need to be familiar with typical MRI findings in order to accurately detect and classify muscle injuries. Proper interpretation of the findings is crucial, especially in elite athletes. In soccer players, muscle injuries of the hip and thigh are the most common reason for missing a game.The present pictorial review deals with the diagnostic assessment, especially MRI, of muscle injuries of the hip and thigh. Typical MR findings in muscle injuries include edema, hematoma, and tendinous avulsion as well as partial or complete muscle tear. To estimate the time to return to play, a grading into three groups-muscle strain, partial tear, complete tear-has traditionally been used. Taking into account the most recent literature, there are other prognostic factors such as the longitudinal length of a tear, the tendon's intramuscular component, or persisting edema.

17.
Invest Radiol ; 53(1): 26-34, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28846552

RESUMO

OBJECTIVES: Grating-based phase-contrast computed tomography (gb-PCCT) relies on x-ray refraction instead of absorption to generate high-contrast images in biological soft tissue. The aim of this study was to evaluate the potential of gb-PCCT for the depiction of structural changes in heart disease. MATERIALS AND METHODS: Four human heart specimens from patients with hypertensive disease, ischemic disease, dilated heart disease, and cardiac lipomatosis were examined. The gb-PCCT setup consisted of an x-ray tube (40 kV, 70 mA), grating-interferometer, and detector, and allowed simultaneous acquisition of phase- and absorption-contrast data. With histopathology as the standard of reference, myocardium (MC), fibrotic scar (FS), interstitial fibrosis (IF), and fatty tissue (FT) were visually and quantitatively evaluated. Systematic differences in absorption- and phase-contrast Hounsfield units (HUabs and HUp) were assessed. RESULTS: Thirteen corresponding cross-sections were included, and MC, FS, IF, and FT were found in 13 (100%), 4 (30.8%), 7 (53.8%), and 13 (100%) cross-sections, respectively. Mean HUp/HUabs were 52.5/54.1, 86.6/69.7, 62.4/62.3, and -38.6/-258.9 for MC, FS, IF, and FT, respectively. An overlap in HUabs was observed for MC and IF (P = 0.84) but not for HUp (P < 0.01). Contrast-to-noise ratios were significantly higher in phase- than in absorption-contrast for MC/FT (35.4 vs 7.8; P < 0.01) and for MC/FS (12.3 vs 0.2; P < 0.01). CONCLUSIONS: Given its superior soft tissue contrast, gb-PCCT is able to depict structural changes in different cardiomyopathies, which can currently not be obtained by x-ray absorption-based imaging methods. If current technical limitations can be overcome, gb-PCCT may evolve as a powerful tool for the anatomical assessment of cardiomyopathy.


Assuntos
Meios de Contraste , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Avaliação como Assunto , Humanos , Reprodutibilidade dos Testes
18.
Sci Rep ; 7: 45400, 2017 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-28361951

RESUMO

Current clinical imaging methods face limitations in the detection and correct characterization of different subtypes of renal cell carcinoma (RCC), while these are important for therapy and prognosis. The present study evaluates the potential of grating-based X-ray phase-contrast computed tomography (gbPC-CT) for visualization and characterization of human RCC subtypes. The imaging results for 23 ex vivo formalin-fixed human kidney specimens obtained with phase-contrast CT were compared to the results of the absorption-based CT (gbCT), clinical CT and a 3T MRI and validated using histology. Regions of interest were placed on each specimen for quantitative evaluation. Qualitative and quantitative gbPC-CT imaging could significantly discriminate between normal kidney cortex (54 ± 4 HUp) and clear cell (42 ± 10), papillary (43 ± 6) and chromophobe RCCs (39 ± 7), p < 0.05 respectively. The sensitivity for detection of tumor areas was 100%, 50% and 40% for gbPC-CT, gbCT and clinical CT, respectively. RCC architecture like fibrous strands, pseudocapsules, necrosis or hyalinization was depicted clearly in gbPC-CT and was not equally well visualized in gbCT, clinical CT and MRI. The results show that gbPC-CT enables improved discrimination of normal kidney parenchyma and tumorous tissues as well as different soft-tissue components of RCCs without the use of contrast media.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X/métodos , Antígenos de Neoplasias , Humanos , Proteínas Quinases Ativadas por Mitógeno , Sensibilidade e Especificidade
19.
Eur J Radiol ; 94: 38-45, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28941758

RESUMO

OBJECTIVES: Dark-field imaging based on small angle X-ray scattering has been shown to be highly sensitive for microcalcifications, e.g. in breast tissue. We hypothesized (i) that high signal areas in dark-field imaging of atherosclerotic plaque are associated with microcalcifications and (ii) that dark-field imaging is more sensitive for microcalcifications than attenuation-based imaging. METHODS: Fifteen coronary artery specimens were examined at an experimental set-up consisting of X-ray tube (40kV), grating-interferometer and detector. Tomographic dark-field-, attenuation-, and phase-contrast data were simultaneously acquired. Histopathology served as standard of reference. To explore the potential of dark field imaging in a full-body CT system, simulations were carried out with spherical calcifications of different sizes to simulate small and intermediate microcalcifications. RESULTS: Microcalcifications were present in 10/10 (100%) cross-sections with high dark-field signal and without evidence of calcifications in attenuation- or phase contrast. In positive controls with high signal areas in all three modalities, 10/10 (100%) cross-sections showed macrocalcifications. In negative controls without high signal areas, no calcifications were detected. Simulations showed that the microcalcifications generate substantially higher dark-field than attenuation signal. CONCLUSIONS: Dark-field imaging is highly sensitive for microcalcifications in coronary atherosclerotic plaque and might provide complementary information in the assessment of plaque instability.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Autopsia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Doença da Artéria Coronariana/patologia , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
J Invest Dermatol ; 133(3): 803-811, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23096710

RESUMO

Tissue inhibitors of metalloproteinases exhibit diverse physiological/biological functions including moderation of the proteolytic processing of growth factors and turnover of extracellular matrix. These various biological activities are linked in part to the stoichiometry of tissue inhibitor of metalloprotein/matrix metalloprotein (TIMP/MMP)/surface protein interactions. TIMP-1, a secreted protein, can be detected on the cell surface only through its interaction with surface-bound proteins. Proteins anchored by glycosylphosphatidylinositol (GPI), when purified and added to cells or tissues, are efficiently incorporated into their surface membranes. A GPI anchor was fused to TIMP-1 to focus defined concentrations of the inhibitory protein independently on the surface of primary dermal fibroblast cells. Exogenously added recombinant TIMP-1-GPI effectively inserted into the cell membrane of fibroblasts blocked the secretion of MMPs and markedly altered the stoichiometry of MMP association with the cell surface. TIMP-1-GPI treatment resulted in inhibition of fibroblast-reduced proliferation, and transiently reduced expression of fibrosis-associated genes. These effects were dose dependent. Treated cells also showed a more proapoptotic phenotype based on apoptotic assays and western blot analysis for apoptosis-associated protein expression. GPI-anchored TIMP-1 may represent a more effective version of the protein for use in therapeutic approaches to help control fibrosis and scar formation.


Assuntos
Cicatriz/fisiopatologia , Derme/patologia , Fibroblastos/efeitos dos fármacos , Proteínas Ligadas por GPI/farmacologia , Inibidor Tecidual de Metaloproteinase-1/farmacologia , Apoptose , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Relação Dose-Resposta a Droga , Fibroblastos/metabolismo , Fibroblastos/patologia , Fibrose , Humanos , Técnicas In Vitro , Metaloproteinases da Matriz/metabolismo , Fator de Necrose Tumoral alfa/farmacologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa