Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Oncol Pharm Pract ; 30(2): 251-256, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37203170

RESUMO

INTRODUCTION: Compounding robots are increasingly being implemented in hospital pharmacies. In our hospital, the recent acquisition of a robot (RIVATM, ARxIUM) for intravenous cancer drug compounding obliged us to replace the previously used infusion devices. The objective of the present study was to assess and qualify the new intravenous sets prior to their use in our hospital and prior to the implementation of the compounding robot. MATERIALS AND METHODS: The ChemoLockTM (ICU Medical) was compared with the devices used previously for compounding (BD PhaSealTM, Becton-Dickinson) and infusion (Connect-ZTM, Codan Medical). The connection/disconnection of infusion devices to/from 50 mL infusion bags was tested with a dynamometer (Multitest-i, Mecmesin). Leakage contamination was visualized by a methylene blue assay and was quantified in simulated pump infusions with 20 mg/mL quinine sulfate (N = 36/group); after the analytical assay had been validated, quinine was detected by UV-spectrophotometry at 280 and 330 nm. Groups were compared using chi-squared or Mann-Whitney U tests. RESULTS: The connection/disconnection test showed that although all the devices complied with the current standard, there was a statistically significant difference in the mean ± standard deviation compression force (51.5 ± 11.6 for the Connect-ZTM vs. 60.3 ± 11.7 for the ChemoLockTM; p = 0.0005). Leaks were detected in 32 (29.1%) of the 110 tests of the ChemoLockTM. The contamination rates were also significantly different: 13.9% for the BD PhaSealTM versus 75.0% for the ChemoLockTM; p < 0.0001). DISCUSSION/CONCLUSION: Our results showed that the new infusion device complied with current standards. However, the presence of contamination emphasizes the need for operators to use the recommended personal protective equipment. Further studies of contamination with cancer drugs are required.


Assuntos
Antineoplásicos , Neoplasias , Exposição Ocupacional , Robótica , Humanos , Robótica/métodos , Composição de Medicamentos/métodos , Exposição Ocupacional/análise , Neoplasias/tratamento farmacológico
2.
J Oncol Pharm Pract ; : 10781552241276530, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39183571

RESUMO

INTRODUCTION: Many hospitals are now investing in robotic compounding system for the preparation of cytotoxic agents. The objective of the present study was to describe contamination by cytotoxics inside and outside the RIVATM robot (ARxIUM, Winnipeg, Canada). MATERIAL & METHODS: We applied a risk analysis to determine which locations inside and outside the compounding robot should be monitored. Samples were collected by swabbing with a wet swab (using 0.1 mL of sterile water) before the robots was cleaned. Ten cytotoxics compounded with the robot were screened for using LC-MS/MS. We determined the percentage contamination rates inside (CRin) and outside (CRout) the robot and the amounts of each contaminant (in ng/cm²). If a sample was found to be positive, a corrective action was implemented. RESULTS: Our risk analysis highlighted 10 locations inside the robot and 7 outside. Ten sampling campaigns (10 samples per campaign) were performed. The mean CRin (40%) was significantly higher than the mean CRout (2%; p < 10-4). Gemcitabine and cyclophosphamide were the main contaminants. After the implementation of corrective measures (such as daily cleaning with SDS/isopropyl alcohol), the CRin fell from 60% to 10%. DISCUSSION/CONCLUSION: The frequency of contamination was lower for robotic compounding than for manual compounding in an isolator. However, robotic compounding tended to generated larger mean amounts of contaminant; this was related to incidents such as splashing when syringes were disposed of after the compounding. The implementation of corrective actions effectively reduced the CRs. Further longer-term studies are required to confirm these results.

3.
Ann Pharm Fr ; 2024 Oct 24.
Artigo em Francês | MEDLINE | ID: mdl-39461657

RESUMO

OBJECTIVES: Chronic total occlusion (CTO) of coronary arteries is defined as complete absence of antegrade coronary flow without iodine passage, since more than 3 months. Coronary revascularization is a highly resource-intensive angioplasty procedure involving numerous medical devices (MDs). Its consumption and associated costs are not covered by either the medical act classification (CCAM) or the hospitalization fees and additional MD funding. The primary aim of this study is to analyze the financial sustainability of this activity for a public healthcare institution and to assess the budgetary impact of CTO treatment on the most expensive items of expenditure. The secondary aim is to describe the patient's intra-hospital pathway. METHODS: CTO revascularization stays are categorized under the code 05K06 "Vascular Stents without Myocardial Infarction". Major cost items were identified using national coded expenditure data and compared with those from our cost study. Every CTO intervention from January to November 2021 were retrospectively retrieved. Establishment purchase prices in 2021 were used to determine MD costs. Clinical data were extracted from electronic patient records. Operative data (procedure duration, professionals involved, and MD used) were extracted. Human Resources (HR) costs were integrated into the calculations. A Sankey diagram was created. Data are expressed as mean ± standard deviation. RESULTS: In our study, 41 patients underwent 45 interventions. The median was 65 years. 78% of interventions were successful with a median duration of 113 minutes. 222 different MD references were used, with 27% reimbursed additionally and 73% funded within the homogeneous group of stays (HGS). The total cost of MD described in the coded expenditure data is 2142euro, of which 721euro is funded within the HGS. In our cohort, it represented averages of 2736euro ± 1393euro and 1710euro ± 926euro, respectively. Regarding HR, the total cost described in the coded expenditure data was 442euro compared to 410euro ± 169euro in our cohort. Finally, patient pathway analysis showed an average length of stay (LOS) of 1.8 days. Two pathways were identified depending on admission context: weekday hospitalization or cardiac intensive care. CONCLUSIONS: CTO revascularization is a planned intervention with a short LOS and a highly standardized patient pathway. Our study highlights a proliferation of MD references used during CTO revascularization due to innovative industrial developments. The cost differential with coded expenditure data confirms the need for a revision of the procedure and its categorization within an HGS, which is currently non-specific.

4.
J Pharm Technol ; 40(6): 296-299, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39507876

RESUMO

Background: Closed system transfer devices (CSTD) help to reduce the exposure of healthcare professionals to hazardous drugs. They may be used in stability studies conducted on anticancer drugs. During a stability study about polyolefin bags of gemcitabine, Tevadaptor® device was suspected of causing a bias in the evaluation of the concentrations of the first aliquots extracted from the bags. Objective: The objectives are to determine whether the use of a CSTD to prepare a drug solution and to withdraw it from a bag can interfere on the measured concentration compared to the expected one and to suggest hypothesis to explain the phenomenon. Method: In the first experiment, three polyolefin bags of gemcitabine (5.4 mg/mL) were prepared under aseptic conditions using the Tevadaptor Luer Lock Adaptor®. The day of preparation, five aliquots of 3.8 ml each were sequentially withdrawn from each polyolefin bag using the same device. After one day, a new aliquot was withdrawn from each bag. In the second experiment, three polyolefin bags of gemcitabine (5.4 mg/ml) were prepared under aseptic conditions using a needle. One aliquot was extracted using a needle after the preparation from each bag, and another aliquot was extracted after one day. The concentrations of all aliquots were measured by liquid chromatography coupled to a photodiode array detector during the same run. Results and discussion: The concentrations of the first aliquots extracted on day zero from the polyolefin bags using the Tevadaptor Luer Lock Adaptor® exhibit an overestimation of 26% ([95%CI: 23%-29%] P<0.001) compared to the others. Overestimation is not found for subsequent aliquots, or while using a needle to bypass the Tevadaptor® device. Conclusion: This case highlights the bias that may arise when using CSTDs in stability studies. They should be used with comprehensive understanding of their technical specifications.

5.
Occup Environ Med ; 80(3): 146-153, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36717254

RESUMO

OBJECTIVES: This study aimed to monitor the contamination by antineoplastic drugs on work surfaces in a compounding unit 4 years after its implementation. METHODS: This descriptive study was done in a unit performing on average 45 000 preparations per year. Surface sampling points (N=23) were monitored monthly in the frame of routine activity from the opening of an anticancer drug compounding unit. Contamination with nine antineoplastic drugs (cyclophosphamide, ifosfamide, dacarbazine, 5-fluorouracil, methotrexate, gemcitabine, cytarabine, irinotecan and doxorubicin) was assessed on wipes with a local liquid chromatography coupled with a tandem mass spectrometer analysis. The contamination rate (CR, %) was prospectively monitored every month during the entire study period. The occurrence of critical incidents was also registered. The effect of each safety measure implemented during this period was also analysed. RESULTS: Based on the 1104 samples collected between March 2016 and March 2020, the CR was 18.5%. If three different critical incidents among a vial breakage that occurred were individually considered, this CR was slightly lower than that in the literature. Eight months after opening and taking different corrective actions, the overall CR dropped from 42.39% to 11.52% (p<0.001). Contamination was limited to the area that includes the compounding room and, more precisely, the welder and the QC-Prep+ sampling points. CONCLUSIONS: From the beginning of the study and from month to month, surface contamination was limited to the nearest sampling points to the compounding unit. This 4-year monitoring study allowed us to determine the intravenous conventional antineoplastic drugs and sampling points to be focused on.


Assuntos
Antineoplásicos , Exposição Ocupacional , Humanos , Seguimentos , Antineoplásicos/análise , Antineoplásicos/química , Ciclofosfamida/efeitos adversos , Ciclofosfamida/análise , Ifosfamida/análise , Fluoruracila/análise , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Monitoramento Ambiental/métodos
6.
J Oncol Pharm Pract ; 29(8): 1893-1906, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36785934

RESUMO

INTRODUCTION: Healthcare workers are exposed to hazardous drugs such as antineoplastic drugs, which have potential carcinogenic, mutagenic and teratogenic effects. Protective measures must be taken after appropriate staff training to handle antineoplastic drugs in a safe way. The objective was to assess perception, knowledge, practices and training regarding the risk of exposure of healthcare workers in three French compounding units. METHODS: This descriptive study was based on a questionnaire made of 33 questions divided into five sections related to the handling of antineoplastic drugs: perception of the risks, knowledge of the risks, protection practices, specific training and general questions. RESULTS: Among the 39 participants, over half considered their overall risk of exposure to antineoplastic drugs not being very low. Inhalation was known to 69.2% of them as possible route of contamination. The breakroom was identified by 28.9% of them as a place of contamination. The procedure in case of accidental exposure to antineoplastic drugs was known by 69.2%, but only half could explain it. Only 38.5% said they changed their gloves every 30 min as recommended. Barely half said that they had been trained specifically for the handling of antineoplastic drugs during an initial training. Over half wished to be informed, trained and aware of the proper handling of antineoplastic drugs. CONCLUSION: Although some of these results are encouraging, specifically when compared to the other settings where antineoplastic drugs are handled, there is still room for improvement. Efforts to build an adapted and impactful training program must pursue. CLINICAL TRIAL REGISTRATION: Study CONTACT, ref. 19-504.


Assuntos
Antineoplásicos , Exposição Ocupacional , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Antineoplásicos/efeitos adversos , Pessoal de Saúde , Inquéritos e Questionários , Percepção
7.
J Oncol Pharm Pract ; 29(7): 1628-1636, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36514878

RESUMO

INTRODUCTION: Ever since the late 1970s, occupational exposure associated with the handling of antineoplastic drugs (ADs) in the healthcare environment has been highlighted and demonstrated. Contamination was detected in both operating rooms (OR) and compounding units (CU), where healthcare workers handle and are exposed to ADs in different ways. In the OR, the risk of exposure is higher and the staff receives less training in handling ADs than in the CU. This study aimed to assess and compare knowledge and practices about the safe handling of ADs by caregivers working in these two locations, namely the CU and OR. METHODS: Two questionnaires (one each for the OR and CU) were created by two investigator pharmacists and were completed during a personal interview of 20 min. The questions were related to the following topics: training, knowledge about occupational exposure and questions related to protective practices. A scoring system was implemented to assess the knowledge and practices of each participant. RESULTS: In total, 38 caregivers working in the OR and 39 in the CU were included in our study. Significantly more CU staff had specific initial training (p < 0.001) and ongoing training (p < 0.001) in handling ADs. Concerning the knowledge score, OR caregivers had a significantly lower median score for contamination routes (p < 0.001), contamination surfaces (p < 0.001), existing procedures (p < 0.001) and total knowledge (p < 0.001) than CU caregivers. Concerning protective handling practices of ADs, the two locations had nonsignificantly different median scores (p = 0.892). CONCLUSION: This study suggests that there is still room for improvement in terms of knowledge and protection practices when handling ADs. An appropriate and tailored training program should be developed and provided to all caregivers who handle or come in contact with ADs.Clinical trial registrationStudy CONTACT, ref. 19-504.


Assuntos
Antineoplásicos , Exposição Ocupacional , Humanos , Quimioterapia Intraperitoneal Hipertérmica , Cuidadores , Salas Cirúrgicas , Antineoplásicos/efeitos adversos , Pessoal de Saúde , Exposição Ocupacional/prevenção & controle
8.
J Oncol Pharm Pract ; 29(8): 1878-1883, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36718964

RESUMO

BACKGROUND: Chemotherapy doses are usually prescribed on the basis of body surface area but dose banding is emerging as an efficient alternative. Dose banding presents the possibility of in-advance preparation in a Centralized Intravenous Admixture Service. AIM OF THE STUDY: To evaluate the long-term stability of 5-fluorouracil at banded doses (700 mg and 800 mg) in polyolefin bags. MATERIALS AND METHODS: Ten polyolefin bags were prepared under aseptic conditions and stored at 23 ± 2°C for 24 days. Five of them were composed of 14 mL 5-fluorocuracil (700 g) in 100 mL 0.9% sodium chloride solution and the five other of 16 mL 5-fluorouracil (800 mg) in 100 mL 0.9% sodium chloride solution. At defined times, physical stability parameters were assessed: optical densities, pH measurements, visual and microscopical inspections. Solutions concentrations were measured using high-performance liquid chromatography coupled with a photodiode array detector. RESULTS: No change was observed on pH and optical density measurements during the study period. Visual and microscopical inspections remained free of colour change, precipitate, microagregate or crystal. The concentrations of 5-Fluorouracil in 800 mg bags remained stable for 24 days while the concentration in 700 mg bags showed a stability of at least 17 days. CONCLUSION: Five-fluorouracil at banded doses of 700 and 800 mg in polyolefin bags is physicochemically stable for at least 17 days at 23 ± 2°C. These results support the possibility of in advance centralised preparation.


Assuntos
Fluoruracila , Cloreto de Sódio , Humanos , Cloreto de Sódio/química , Embalagem de Medicamentos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Cromatografia Líquida de Alta Pressão
9.
Ann Pharmacother ; 56(9): 1007-1015, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35016532

RESUMO

BACKGROUND: Defibrotide is indicated for patients who develop severe sinusoidal obstructive syndrome following allogeneic hematopoietic cell transplantation (allo-HCT). Preclinical data suggested that defibrotide carries a prophylactic effect against acute graft-versus-host disease (aGVHD). OBJECTIVE: The purpose of this study was to investigate the effect of defibrotide on the incidence and severity of aGVHD. METHODS: This single-center retrospective study included all consecutive transplanted patients between January 2014 and December 2018. A propensity score based on 10 predefined confounders was used to estimate the effect of defibrotide on aGVHD via inverse probability of treatment weighting (IPTW). RESULTS: Of the 482 included patients, 64 received defibrotide (defibrotide group) and 418 did not (control group). Regarding main patient characteristics and transplantation modalities, the two groups were comparable, except for a predominance of men in the defibrotide group. The median age was 55 years (interquartile range [IQR]: 40-62). Patients received allo-HCT from HLA-matched related donor (28.6%), HLA-matched unrelated donor (50.8%), haplo-identical donor (13.4%), or mismatched unrelated donor (7.0%). Stem cell source was either bone marrow (49.6%) or peripheral blood (50.4%). After using IPTW, exposure to defibrotide was not significantly associated with occurrence of aGVHD (HR = 0.97; 95% CI 0.62-1.52; P = .9) or occurrence of severe aGVHD (HR = 1.89, 95% CI: 0.98-3.66; P = .058). CONCLUSION AND RELEVANCE: Defibrotide does not seem to have a protective effect on aGVHD in patients undergoing allo-HCT. Based on what has been reported to date and on these results, defibrotide should not be considered for the prevention of aGVHD outside clinical trials.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Doença Aguda , Feminino , Doença Enxerto-Hospedeiro/epidemiologia , Doença Enxerto-Hospedeiro/etiologia , Doença Enxerto-Hospedeiro/prevenção & controle , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doadores de Tecidos , Transplante Homólogo/efeitos adversos
10.
Br J Anaesth ; 129(6): 937-945, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36243576

RESUMO

BACKGROUND: The optimal dose of tranexamic acid to inhibit hyperfibrinolysis in postpartum haemorrhage is unclear. Tranexamic Acid to Reduce Blood Loss in Hemorrhagic Cesarean Delivery (TRACES) was a double-blind, placebo-controlled, randomised, multicentre dose-ranging study to determine the dose-effect relationship for two regimens of intravenous tranexamic acid vs placebo. METHODS: Women experiencing postpartum haemorrhage during Caesarean delivery were randomised to receive placebo (n=60), tranexamic acid 0.5 g (n=57), or tranexamic acid 1 g i.v. (n=58). Biomarkers of fibrinolytic activation were assayed at five time points, with inhibition of hyperfibrinolysis defined as reductions in the increase over baseline in D-dimer and plasmin-antiplasmin levels and in the plasmin peak time. RESULTS: In the placebo group, hyperfibrinolysis was evidenced by a mean increase over baseline [95% confidence interval] of 93% [68-118] for D-dimer level at 120 min and 56% [25-87] for the plasmin-antiplasmin level at 30 min. A dose of tranexamic acid 1 g was associated with smaller increases over baseline (D-dimers: 38% [13-63] [P=0.003 vs placebo]; plasmin-antiplasmin: -2% [-32 to 28] [P=0.009 vs placebo]). A dose of tranexamic acid 0.5 g was less potent, with non-significant reductions (D-dimers: 58% [32-84] [P=0.06 vs placebo]; plasmin-antiplasmin: 13% [18-43] [P=0.051]). Although both tranexamic acid doses reduced the plasmin peak, reduction in plasmin peak time was significant only for the 1 g dose of tranexamic acid. CONCLUSIONS: Fibrinolytic activation was significantly inhibited by a dose of intravenous tranexamic acid 1 g but not 0.5 g. Pharmacokinetic-pharmacodynamic modelling of these data might identify the best pharmacodynamic monitoring criteria and the optimal tranexamic acid dosing regimen for treatment of postpartum haemorrhage. CLINICAL TRIAL REGISTRATION: NCT02797119.


Assuntos
Antifibrinolíticos , Transtornos da Coagulação Sanguínea , Hemorragia Pós-Parto , Ácido Tranexâmico , Humanos , Gravidez , Feminino , Ácido Tranexâmico/uso terapêutico , Hemorragia Pós-Parto/tratamento farmacológico , Fibrinolisina , Método Duplo-Cego , Cesárea , Biomarcadores
11.
J Oncol Pharm Pract ; : 10781552221103803, 2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35635230

RESUMO

BACKGROUND: Antineoplastic drug exposure is a major problem in regard to caregivers' health. The aim of the present study was to assess the perception, knowledge, and handling practices of all occupation level categories of two oncology day hospitalization units and two compounding units regarding the risk of exposure to antineoplastic drugs. METHODS: This descriptive study, performed through face-to-face interviews, concurrently assessed the perception, knowledge, and handling practices of antineoplastic drugs in five different job categories in four different settings. This work was part of a larger comprehensive project examining surface and blood contamination. Different scores were assigned to evaluate responses to a questionnaire about the perception, knowledge, and handling practices of healthcare workers, a risk global score including a risk perception score, and education/knowledge and handling practices scores. RESULTS: In the survey, continuous training was associated with the global risk score (p = 0.03), particularly with the handling practices risk score (p = 0.01). Job category was also significantly associated with the global risk score (p < 0.001), particularly with the handling practices risk score (p < 0.001) and the education/knowledge score (p < 0.001). Pharmacy technicians had the highest score regarding risk perception (71.4%), indicating a higher perception of risk, and had a lower score regarding handling practices (25.0%) as well as a lower score (15.7%) regarding risk knowledge. Nurses and physicians had a high score (50%) regarding the risk of handling practices and a score of 57.1% regarding risk perception, indicating an increased perception of safety. Auxiliary caregivers had the highest global score (43.5%) and a score of 30.0% regarding handling practices. CONCLUSIONS: This study identified significant differences among healthcare workers depending on job categories in the antineoplastic drug handling practices and in the knowledge of the risks associated with occupational exposure to antineoplastic drugs. These differences were particularly important between trained and untrained participants, revealing the importance of implementing a continuous training program.

12.
Int J Mol Sci ; 23(19)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36233193

RESUMO

Multiple Sclerosis (MS) is an autoimmune demyelinating and neurodegenerative disease of the central nervous system (CNS). Current management strategies suppress or modulate immune function, all with consequences and known side effects. They demonstrate a high level of success in limiting new relapses. However, the neurodegenerative process still affects both grey and white matter in the central nervous system. The sigma1 (S1R) ligand-regulated chaperone is implicated in many biological processes in various CNS-targeted diseases, acting on neural plasticity, myelination and neuroinflammation. Among the proteins involved in MS, S1R has therefore emerged as a promising new target. Standard and robust methods have been adopted to analyze the adsorption, distribution, metabolism, excretion (ADME) properties, safety pharmacology and toxicology of a previously synthetized simple benzamide-derived compound with nanomolar affinity for S1R, high selectivity, no cytotoxicity and good metabolic stability. The compound was also characterized as an agonist based on well-validated assays prior to in vivo investigations. Interestingly, we found that the oral administration of this compound resulted in an overall significant reduction in clinical progression in an MS experimental model. This effect is mediated through S1R action. Our results further suggest the potential use of this compound in the treatment of MS.


Assuntos
Doenças do Sistema Nervoso Central , Esclerose Múltipla , Doenças Neurodegenerativas , Receptores sigma , Benzamidas/uso terapêutico , Humanos , Ligantes , Esclerose Múltipla/tratamento farmacológico , Receptores sigma/metabolismo
13.
Eur J Clin Pharmacol ; 77(9): 1309-1321, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33768303

RESUMO

PURPOSE: Drug protocols in intensive care units may require the concomitant administration of many drugs as patients' venous accesses are often limited. A major challenge for clinicians is to limit the risk of simultaneously infusing incompatible drugs. Incompatibilities can lead to the formation of particles and inactivation of drugs, whose consequences on the body have already been indicated. Our objective was to assess current strategies to counter the risk of incompatible infusions and control the resulting clinical consequences. METHODS: This review was independently conducted by three investigators in respect of the PRISMA statement. Three online databases were consulted. Full-text articles, notes, or letters written in English or French, published or in press between the 1990s and the end of February 2020, with clinical study design, were eligible. Parameters of interest were mainly number and size of particles, and a number of observed/avoided incompatibilities. RESULTS: All in all, 382 articles were screened, 17 meeting all the acceptance criteria. The strategies outlined and assessed were filtration, the use of multi-lumen devices, the purging of infusion lines, incompatibility tables and databases, and the use of standard operating procedures. CONCLUSION: Although many strategies have been developed in recent years to address drug incompatibility risks, clinical data is still lacking. All studies with in vitro design were excluded although some current innovative strategies, like niosomes, should be considered and studied by means of clinical data in the future.


Assuntos
Incompatibilidade de Medicamentos , Infusões Intravenosas/métodos , Unidades de Terapia Intensiva , Protocolos Clínicos , Filtração , Humanos , Infusões Intravenosas/instrumentação
14.
Eur J Pediatr ; 180(9): 2985-2992, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33866404

RESUMO

Neonatal hyperglycaemia is frequent and requires insulin therapy. To resolve the difficulties encountered by paediatricians in stabilising glycaemia, the preparation and administration of insulin aspart were assessed and optimised. After high-performance liquid chromatography (HPLC-UV) assessment of insulin aspart preparations made according to the old protocol, a new protocol was drawn up. Dosage reliability of solutions prepared by paediatric nurses was evaluated by HPLC-UV. This new protocol was also tested in a Y-infusion situation and the need to saturate infusion tubes assessed. Wide deviations in insulin aspart concentrations were found between theoretical concentrations and preparations made according to the old protocol. Glycated insulin aspart was found in the majority of these preparations. The new protocol significantly reduced the variability of data and relative deviations around the target value. It also eliminated the formation of glycated insulin even in the case of co-infusion of parenteral nutrition and confirmed the need to saturate infusion tubes.Conclusion: The revision of the insulin therapy protocol reduced the variability of insulin concentration in preparations and avoided the administration of glycated derivatives potentially toxic for neonates. What is Known: • Insulin preparation in NICUs is a risky task because it is a two-step preparation • Diluted in dextrose, insulin aspart is unstable, with formation of potentially toxic glycated derivatives What is New: • This work proposes a new insulin therapy protocol validated by HPLC-UV for NICU allowing suppression of the formation of glycated insulin, to significantly reduce deviations from theoretical concentrations and to limit adsorption phenomena • This protocol is validated in case of co-infusion of parenteral nutrition.


Assuntos
Hiperglicemia , Insulina Aspart , Glicemia , Humanos , Hipoglicemiantes , Recém-Nascido , Insulina , Unidades de Terapia Intensiva Neonatal , Reprodutibilidade dos Testes
15.
BMC Pediatr ; 21(1): 343, 2021 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-34388991

RESUMO

BACKGROUND: Vancomycin is commonly used as part of empiric antibiotic therapy in the preterm infants who develop signs and symptoms of infection. Although skin necrosis has been noted to occur following injection of vancomycin into a peripheral vein in an adult patient, this complication has not been previously described in a preterm infant. CASE PRESENTATION: We report the case of a very low birthweight male infant born at 30 weeks gestational age who developed skin necrosis, most likely as a complication of vancomycin administration via a peripheral venous catheter. The immature skin and endothelial cells of this preterm infant may have increased the risk of drugs related venous and skin toxicity. In this case, assumption of a cumulative toxicity with other drugs administered concomitantly via the same catheter can't be excluded. CONCLUSIONS: To prevent the risk of skin damage, we advocate that in newborn infants, the administration of vancomycin should be limited to a concentration of < 2.5 mg/mL via a peripheral intravenous catheter if a central venous catheter is not available.


Assuntos
Estado Terminal , Vancomicina , Adulto , Células Endoteliais , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Masculino , Necrose/induzido quimicamente , Vancomicina/efeitos adversos
16.
J Oncol Pharm Pract ; 27(6): 1328-1332, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32903143

RESUMO

BACKGROUND: Patients undergoing chemotherapeutic treatment are currently treated by a concomittent infusion of alizapride and ondansetron. To optimise the procedure and to ensure patients' safety, the admixture could be prepared in advance by the Centralized Intravenous Additive Service (CIVAS) provided that the stability of the mixture has been proven beforhand to reduce nausea and vomiting.Aim of the study: to evaluate the long-term stability of an admixture of alizapride 0.926 mg/l and ondansetron 0.074 mg/ml in 0.9% sodium chloride polyolefin bags stored at 5 ± 3°C. MATERIAL AND METHODS: Five polyolefin bags containing 100 ml sodium chloride 0.9% added with 4 ml alizapride (100 mg) and 4 ml ondansetron (8 mg) were prepared in aseptic conditions and stored at 5 ± 3°C for 56 days. Periodically, physical stability tests were performed including: pH measurements, optical density measurements at 350, 410 and 550 nm to track turbidity appearance, visual and microscopical inspections to detect colour changes, precipitation, microaggregates or crystals. The concentrations of the solutions were measured by High Performance Liquid Chromatography coupled with an UV detector. RESULTS: There was no change in pH and optical densities during the study period. Visual and microscopical inspections didn't show any change of colour neither precipitation, microaggregate or crystal. The alizapride and ondansetron concentrations remained stable over the study. CONCLUSION: The admixture of alizapride and ondansetron in 0.9% sodium chloride solution polyolefin bags is physicochemically stable up to 56 days at 5 ± 3°C. These results support the possibility of preparing the solutions in advance by a CIVAS.


Assuntos
Ondansetron , Cloreto de Sódio , Cromatografia Líquida de Alta Pressão , Embalagem de Medicamentos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Humanos , Polienos , Pirrolidinas
17.
Neurobiol Dis ; 139: 104846, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32205254

RESUMO

BACKGROUND: Continuous compensation of dopamine represents an ideal symptomatic treatment for Parkinson's disease (PD). The feasibility in intracerebroventricular administration (i.c.v.) of dopamine previously failed because of unresolved dopamine oxidation. OBJECTIVES: We aim to test the feasibility, safety margins and efficacy of continuous i.c.v. of anaerobic-dopamine (A-dopamine) with a pilot translational study in a non-human primate model of PD. METHODS: Continuous and circadian i.c.v. of A-dopamine was administered through a micro-pump connected to a subcutaneous catheter implanted into the right frontal horn of 8 non-human primates treated with 1-methyl-4- phenyl-1,2,3,6-tetrahydropyridine (MPTP). A-dopamine was assessed at acute doses previously reported for dopamine as well as evaluating the long term therapeutic index of A-dopamine in comparison to anaerobically prepared L-dopa or methyl ester L-dopa. RESULTS: Over 60 days of a continuous circadian i.c.v. of A-dopamine improved motor symptoms (therapeutic index from 30 to 70 mg/day) without tachyphylaxia. No dyskinesia was observed even with very high doses. Death after 1 to 10 days (without neuronal alteration) was only observed with doses in excess of 160 mg whereas L-dopa i.c.v. was not effective at any dose. The technical feasibility of the administration regimen was confirmed for an anaerobic preparation of dopamine and for administration of a minimal infusion volume by micro-pump at a constant flow that prevented obstruction. CONCLUSION: Continuous circadian i.c.v. of A-dopamine appears to be feasible and shows efficacy without dyskinesia with a safe therapeutic index.


Assuntos
Dopamina/administração & dosagem , Infusões Intraventriculares , Atividade Motora/efeitos dos fármacos , Doença de Parkinson/tratamento farmacológico , 1-Metil-4-Fenil-1,2,3,6-Tetra-Hidropiridina/farmacologia , Animais , Antiparkinsonianos/farmacologia , Modelos Animais de Doenças , Agonistas de Dopamina/farmacologia , Discinesia Induzida por Medicamentos/tratamento farmacológico , Levodopa/análogos & derivados , Levodopa/farmacologia , Macaca , Masculino , Transtornos Parkinsonianos/tratamento farmacológico , Projetos Piloto
18.
J Oncol Pharm Pract ; 26(8): 2038-2041, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32281518

RESUMO

An important amount of cytotoxic drug may accumulate in the workplace following the breakage of a vial containing an anticancer drug. Thanks to the monthly monitoring of the surface contamination in our compounding unit, a strong increase of cyclophosphamide contamination was highlighted in the storage area following the breakage of the vial, despite application of the emergency procedure. This study presents an analysis of chemical decontamination in the context of massive contamination. Samples were taken on the floor and on the caster of a storage shelf where the vial broke. The residual contamination was measured with a liquid chromatography-mass spectrometry/mass spectrometry method. An admixture of 10-2 M sodium dodecyl sulfate and 70% isopropanol (SDS/IPA 8:2) was selected as the decontamination solution. High amounts of cyclophosphamide were retrieved. The initial contamination on the floor was over 20 ng/cm2. Three decontaminations with SDS/IPA were carried out at Day 61, Day 68, and Day 71. The amount of cyclophosphamide decreased to 0.45 ng/cm2 at D134. However, high values were still measured on the caster despite successive decontaminations, with a maximal value of 19.78 ng/cm2 observed at Day 106. Continuous monitoring in our unit led us to highlight the inefficiency of our emergency procedure to eliminate high cyclophosphamide contamination. The procedure involving the SDS/IPA admixture was more efficient on the floor compared to the caster, which is a different surface type and porosity. This work highlights the importance of improving the procedures of incident management using contamination monitoring and repeated decontamination procedures adapted to different contaminants and surfaces.


Assuntos
Antineoplásicos Alquilantes/análise , Ciclofosfamida/análise , Descontaminação/métodos , Monitoramento Ambiental/métodos , Humanos , Local de Trabalho
19.
J Oncol Pharm Pract ; 25(4): 929-946, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30786823

RESUMO

Although considerable efforts have been made over the last 40 years, occupational exposure to antineoplastic drugs is still a daily concern, since eradicating such contamination from workplaces seems unattainable. Considerable data are currently available on the risks associated with their use at work. Hospital facilities are often cleaned with marketed antimicrobials whose chemical decontamination efficacy certainly differs but remains unknown. To keep compounding facilities sterile, alcohol-based solutions are frequently used but with very limited efficiency. It would be particularly useful if a decontamination method could be added to the means already available so that all conventional antineoplastic drug contamination could be removed. Several degradation methods or desorption methods have previously been experimented, with varying success. They have never been compared or discussed in terms either of efficiency or usability. This review aims to analyse and discuss the results of each degradation or decontamination procedure and to compare them. This should facilitate selection of the method to be implemented in daily practice.


Assuntos
Antineoplásicos/análise , Descontaminação/métodos , Exposição Ocupacional/prevenção & controle , Antineoplásicos/química , Humanos , Local de Trabalho
20.
Paediatr Anaesth ; 29(2): 193-199, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30549392

RESUMO

BACKGROUND: Transforming a drug from its commercial form into a ready-to-use drug is common practice, especially in pediatrics. However, the risk of compounding error is real and data on drug stability in practice are not always available. AIMS: The aim of this study was to assess, in real conditions, both the error rate and stability of three drugs: ketamine, remifentanil, and sufentanil. METHODS: A new rapid and easy-to-use high-performance liquid chromatography method with a diode array detector has been developed and validated to quantify these drugs and detect their degradation products. Over a 1-month period, 151 syringes were collected in the postanesthesia care unit. Seventy-three were stock solution syringes containing a 10-fold dilution of commercial drugs and 78 were serial dilution syringes made from successive dilutions of stock solutions. A comparison between real and expected concentrations as well as the detection of possible degradation products was carried out on these samples. RESULTS: All stock solution syringes had good chemical stability throughout the working day. A 4-µg/mL remifentanil serial dilution syringe, however, had to be discarded as a degradation peak was detected. Overall, 15.3% (95% CI, 9.5-21.1%) of syringes had a drug concentration outside the ±10% acceptability range, that is, 11.0% (95% CI, 3.7-18.2%) and 19.5% (95% CI, 10.6%-28.4%) of stock and diluted syringes respectively, with drug amounts ranging from -25.3% to 22.0%. The highest error rates were observed with sufentanil syringes: 20% and 28% for stock solution and serial dilution, respectively. CONCLUSION: The study shows that stock solution syringes prepared in advance are chemically stable throughout the day, unlike certain serial dilution syringes, indicating that the latter should be prepared just before administration to ensure chemical stability. Our results show that the error rate for serial dilution syringes is twice that of stock solution. Different safety measures are under discussion and have to be further studied.


Assuntos
Ketamina/química , Remifentanil/química , Sufentanil/química , Seringas , Anestésicos Intravenosos/análise , Cromatografia Líquida de Alta Pressão , Estabilidade de Medicamentos , Ketamina/análise , Pediatria/métodos , Controle de Qualidade , Remifentanil/análise , Sufentanil/análise
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa