Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 264: 119706, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36349597

RESUMO

Neuromelanin (NM)-sensitive MRI using a magnetization transfer (MT)-prepared T1-weighted sequence has been suggested as a tool to visualize NM contents in the brain. In this study, a new NM-sensitive imaging method, sandwichNM, is proposed by utilizing the incidental MT effects of spatial saturation RF pulses in order to generate consistent high-quality NM images using product sequences. The spatial saturation pulses are located both superior and inferior to the imaging volume, increasing MT weighting while avoiding asymmetric MT effects. When the parameters of the spatial saturation were optimized, sandwichNM reported a higher NM contrast ratio than those of conventional NM-sensitive imaging methods with matched parameters for comparability with sandwichNM (SandwichNM: 23.6 ± 5.4%; MT-prepared TSE: 20.6 ± 7.4%; MT-prepared GRE: 17.4 ± 6.0%). In a multi-vendor experiment, the sandwichNM images displayed higher means and lower standard deviations of the NM contrast ratio across subjects in all three vendors (SandwichNM vs. MT-prepared GRE; Vendor A: 28.4 ± 1.5% vs. 24.4 ± 2.8%; Vendor B: 27.2 ± 1.0% vs. 13.3 ± 1.3%; Vendor C: 27.3 ± 0.7% vs. 20.1 ± 0.9%). For each subject, the standard deviations of the NM contrast ratio across the vendors were substantially lower in SandwichNM (SandwichNM vs. MT-prepared GRE; subject 1: 1.5% vs. 8.1%, subject 2: 1.1 % vs. 5.1%, subject 3: 0.9% vs. 4.0%, subject 4: 1.1% vs. 5.3%), demonstrating consistent contrasts across the vendors. The proposed method utilizes product sequences, requiring no alteration of a sequence and, therefore, may have a wide practical utility in exploring the NM imaging.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Alimentos
2.
Sensors (Basel) ; 22(10)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35632351

RESUMO

MRI is an imaging technology that non-invasively obtains high-quality medical images for diagnosis. However, MRI has the major disadvantage of long scan times which cause patient discomfort and image artifacts. As one of the methods for reducing the long scan time of MRI, the parallel MRI method for reconstructing a high-fidelity MR image from under-sampled multi-coil k-space data is widely used. In this study, we propose a method to reconstruct a high-fidelity MR image from under-sampled multi-coil k-space data using deep-learning. The proposed multi-domain Neumann network with sensitivity maps (MDNNSM) is based on the Neumann network and uses a forward model including coil sensitivity maps for parallel MRI reconstruction. The MDNNSM consists of three main structures: the CNN-based sensitivity reconstruction block estimates coil sensitivity maps from multi-coil under-sampled k-space data; the recursive MR image reconstruction block reconstructs the MR image; and the skip connection accumulates each output and produces the final result. Experiments using the fastMRI T1-weighted brain image dataset were conducted at acceleration factors of 2, 4, and 8. Qualitative and quantitative experimental results show that the proposed MDNNSM method reconstructs MR images more accurately than other methods, including the generalized autocalibrating partially parallel acquisitions (GRAPPA) method and the original Neumann network.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Registros
3.
Sensors (Basel) ; 22(6)2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35336577

RESUMO

Despite the unprecedented success of deep learning in various fields, it has been recognized that clinical diagnosis requires extra caution when applying recent deep learning techniques because false prediction can result in severe consequences. In this study, we proposed a reliable deep learning framework that could minimize incorrect segmentation by quantifying and exploiting uncertainty measures. The proposed framework demonstrated the effectiveness of a public dataset: Multimodal Brain Tumor Segmentation Challenge 2018. By using this framework, segmentation performances, particularly for small lesions, were improved. Since the segmentation of small lesions is difficult but also clinically significant, this framework could be effectively applied to the medical imaging field.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Radiografia , Incerteza
4.
Neuroimage ; 240: 118371, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34242783

RESUMO

Obtaining a histological fingerprint from the in-vivo brain has been a long-standing target of magnetic resonance imaging (MRI). In particular, non-invasive imaging of iron and myelin, which are involved in normal brain functions and are histopathological hallmarks in neurodegenerative diseases, has practical utilities in neuroscience and medicine. Here, we propose a biophysical model that describes the individual contribution of paramagnetic (e.g., iron) and diamagnetic (e.g., myelin) susceptibility sources to the frequency shift and transverse relaxation of MRI signals. Using this model, we develop a method, χ-separation, that generates the voxel-wise distributions of the two sources. The method is validated using computer simulation and phantom experiments, and applied to ex-vivo and in-vivo brains. The results delineate the well-known histological features of iron and myelin in the specimen, healthy volunteers, and multiple sclerosis patients. This new technology may serve as a practical tool for exploring the microstructural information of the brain.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/metabolismo , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/metabolismo , Bainha de Mielina/metabolismo , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Neurológicos , Esclerose Múltipla/diagnóstico por imagem , Adulto Jovem
5.
Radiology ; 300(3): 661-668, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34156299

RESUMO

Background Evaluation of the glymphatic system with intrathecal contrast material injection has limited clinical use. Purpose To investigate the feasibility of using serial intravenous contrast-enhanced T1 mapping in the quantitative evaluation of putative dynamic glymphatic activity in various brain regions and to demonstrate the effect of sleep on glymphatic activity in humans. Materials and Methods In this prospective study from May 2019 to February 2020, 25 healthy participants (mean age, 25 years ± 2 [standard deviation]; 15 men) underwent two cycles of MRI (day and night cycles). For each cycle, T1 maps were acquired at baseline and 0.5, 1, 1.5, 2, and 12 hours after intravenous contrast material injection. For the night cycle, participants had a normal night of sleep between 2 and 12 hours. The time (tmin) to reach the minimum T1 value (T1min), the absolute difference between baseline T1 and T1min (peak ΔT1), and the slope between two measurements at 2 and 12 hours (slope[2h-12h]) were determined from T1 value-time curves in cerebral gray matter (GM), cerebral white matter (WM), cerebellar GM, cerebellar WM, and putamen. Mixed-model analysis of variance (ANOVA), Friedman test, and repeated-measures ANOVA were used to assess the effect of sleep on slope(2h-12h) and to compare tmin and peak ΔT1 among different regions. Results The slope(2h-12h) increased from the day to night cycles in cerebral GM, cerebellar GM, and putamen (geometric mean ratio [night/day] = 1.4 [95% CI: 1.2, 1.7], 1.3 [95% CI: 1.1, 1.4], and 2.4 [95% CI: 1.6, 3.6], respectively; P = .001, P < .001, and P < .001, respectively). Median tmin values were 0.5 hour in cerebral and cerebellar GM and putamen for both cycles. Cerebellar GM had the highest mean peak ΔT1, followed by cerebral GM and putamen in both day (159 msec ± 6, 99 msec ± 4, and 62 msec ± 5, respectively) and night (152 msec ± 6, 104 msec ± 6, and 58 msec ± 4, respectively) cycles. Conclusion Clearance of a gadolinium-based contrast agent was greater after sleep compared with daytime wakefulness. These results suggest that sleep was associated with greater glymphatic clearance compared with wakefulness. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Anzai and Minoshima in this issue.


Assuntos
Encéfalo/diagnóstico por imagem , Sistema Glinfático/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sono/fisiologia , Vigília/fisiologia , Adulto , Meios de Contraste , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Masculino , Estudos Prospectivos
6.
J Magn Reson Imaging ; 53(2): 360-373, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32009271

RESUMO

Myelin water imaging (MWI) is an MRI imaging biomarker for myelin. This method can generate an in vivo whole-brain myelin water fraction map in approximately 10 minutes. It has been applied in various applications including neurodegenerative disease, neurodevelopmental, and neuroplasticity studies. In this review we start with a brief introduction of myelin biology and discuss the contributions of myelin in conventional MRI contrasts. Then the MRI properties of myelin water and four different MWI methods, which are categorized as T2 -, T2 *-, T1 -, and steady-state-based MWI, are summarized. After that, we cover more practical issues such as availability, interpretation, and validation of these methods. To illustrate the utility of MWI as a clinical research tool, MWI studies for two diseases, multiple sclerosis and neuromyelitis optica, are introduced. Additional topics about imaging myelin in gray matter and non-MWI methods for myelin imaging are also included. Although technical and physiological limitations exist, MWI is a potent surrogate biomarker of myelin that carries valuable and useful information of myelin. Evidence Level: 5 Technical Efficacy: 1 J. MAGN. RESON. IMAGING 2021;53:360-373.


Assuntos
Esclerose Múltipla , Doenças Neurodegenerativas , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Bainha de Mielina , Água
7.
Sensors (Basel) ; 21(18)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34577210

RESUMO

For human head magnetic resonance imaging at 10.5 tesla (T), we built an 8-channel transceiver dipole antenna array and evaluated the influence of coaxial feed cables. The influence of coaxial feed cables was evaluated in simulation and compared against a physically constructed array in terms of transmit magnetic field (B1+) and specific absorption rate (SAR) efficiency. A substantial drop (23.1% in simulation and 20.7% in experiment) in B1+ efficiency was observed with a tight coaxial feed cable setup. For the investigation of the feed location, the center-fed dipole antenna array was compared to two 8-channel end-fed arrays: monopole and sleeve antenna arrays. The simulation results with a phantom indicate that these arrays achieved ~24% higher SAR efficiency compared to the dipole antenna array. For a human head model, we observed 30.8% lower SAR efficiency with the 8-channel monopole antenna array compared to the phantom. Importantly, our simulation with the human model indicates that the sleeve antenna arrays can achieve 23.8% and 21% higher SAR efficiency compared to the dipole and monopole antenna arrays, respectively. Finally, we obtained high-resolution human cadaver images at 10.5 T with the 8-channel sleeve antenna array.


Assuntos
Cabeça , Imageamento por Ressonância Magnética , Simulação por Computador , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Imagens de Fantasmas
8.
Neuroimage ; 188: 835-844, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30476624

RESUMO

Gradient echo myelin water imaging (GRE-MWI) is an MRI technique to measure myelin concentration and involves the analysis of signal decay characteristics of the multi-echo gradient echo data. The method provides a myelin water fraction as a quantitative biomarker for myelin. In this work, a new sequence and post-processing methods were proposed to generate high quality GRE-MWI images at 3T and 7T. In order to capture the rapidly decaying myelin water signals, a bipolar readout GRE sequence was designed with "gradient pairing," compensating for the eddy current effects. The flip angle dependency from the multi-compartmental T1 effects was explored and avoided using a 2D multi-slice acquisition with a long TR. Additionally, the sequence was tested for the effects of inflow and magnetization transfer and demonstrated robustness to these error sources. Lastly, the temporal and spatial B0 inhomogeneity effects were mitigated by using the B0 navigator and field inhomogeneity corrections. Using the method, high-quality myelin water images were successfully generated for the in-vivo human brain at both field strengths. When the myelin water fraction at 3T and 7T were compared, they showed a good correlation (R2≥ 0.88; p < 0.001) with a larger myelin water fraction at 7T. The proposed method also opens the possibility of high resolution (isotropic 1.5 mm resolution) myelin water mapping at 7T.


Assuntos
Água Corporal , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina , Neuroimagem/métodos , Adulto , Humanos , Imageamento por Ressonância Magnética/normas , Neuroimagem/normas , Adulto Jovem
9.
Magn Reson Med ; 82(1): 237-250, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30883886

RESUMO

PURPOSE: To propose a novel 3D ultrafast gradient echo-based MRI method, dubbed RASE, using quadratic-phase encoding. THEORY AND METHODS: Several characteristics of RASE, including spin behaviors, spatial resolution, SNR, and reduction of susceptibility-induced signal loss, were analytically described. A way of compensating for TE variation was suggested in the quadratic phase-encoding direction. Lemon, in vivo rat and mouse images were demonstrated at 9.4T, including a feasibility study for DCE-MRI as one of promising applications. RESULTS: RASE was successfully demonstrated by lemon and in vivo rat brain imaging, showing a good robustness to field inhomogeneity. Contribution of the quadratic phase to signal enhancement in a range of magnetic susceptibilities was also evaluated by simulation. Taking a geometric mean of 2 phantom data acquired with opposite gradient polarities effectively compensated for the effect of TE variation. Preliminary DCE-MRI results were also presented, showing that RASE could more accurately estimate Gd concentration than FLASH. CONCLUSION: RASE offers a shorter effective TE, having less sensitivity to field inhomogeneity and T2* effects, much less Nyquist ghosting or chemical-shift artifacts than gradient echo EPI (GE-EPI). We highly anticipate that RASE can be an alternative to GE-EPI in many applications, particularly those requiring high spatial and temporal resolutions in a broad volume coverage.


Assuntos
Imagem Ecoplanar/métodos , Imageamento Tridimensional/métodos , Animais , Encéfalo/diagnóstico por imagem , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Imagens de Fantasmas , Ratos
10.
J Magn Reson Imaging ; 49(6): 1769-1776, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31062456

RESUMO

BACKGROUND: Numerous studies have suggested that quantitative susceptibility mapping (QSM) and transverse relaxation rates ( R2* ) are useful to monitor neurological diseases. For clinical use of QSM and R2* , reproducibility is an important feature. However, respiration-induced local magnetic field variation makes artifacts in gradient echo-based images and reduces the reproducibility of QSM and R2* . PURPOSE: To investigate the improvement of reproducibility of QSM and R2* after the correction of respiration-induced field variation, and to assess the effect of varying types of the region of interest (ROI) analysis on reproducibility. STUDY TYPE: Reproducibility study. POPULATION: Ten controls. FIELD STRENGTH/SEQUENCE: 3T/multiecho gradient echo sequence. ASSESSMENT: Intrascan reproducibility of QSM and R2* was investigated in ROIs before and after the respiration correction. STATISTICAL TESTS: Reproducibility was obtained by the square of voxel-wise correlation coefficients between scans. A paired t-test was performed for comparison between before and after the respiration correction and between QSM and R2* . RESULTS: Based on the ROI analysis, reproducibility increased after the respiration correction. Reproducibility in the white matter (11.89% increased in QSM and 23.38% in R2* , P = 0.009 and 0.024, respectively) and deep gray matter (5.50% increased in QSM and 13.96% in R2* , P = 0.024 and 0.019, respectively) increased significantly after the respiration correction. Reproducibility of R2* was higher than that of QSM in the whole brain and cortical gray matter, while QSM maps showed higher reproducibility than R2* in the white matter and deep gray matter. DATA CONCLUSION: Respiration-induced error correction significantly improved reproducibility in QSM and R2* mapping. QSM and R2* mapping showed a different level of reproducibility depending on the types of ROI analysis. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem Ecoplanar , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética , Doenças do Sistema Nervoso/diagnóstico por imagem , Adulto , Algoritmos , Voluntários Saudáveis , Humanos , Reprodutibilidade dos Testes , Respiração , Adulto Jovem
11.
J Magn Reson Imaging ; 49(4): 1091-1098, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30240519

RESUMO

BACKGROUND: In multiple sclerosis (MS), not only lesions but also normal MRI-appearing white matter (NAWM) may undergo demyelination. PURPOSE: To demonstrate the detection of NAWM demyelination using direct visualization of short transverse relaxation time component myelin water imaging (ViSTa-MWI) and to compare the results with those of conventional gradient echo and spin echo (GRASE)-MWI. STUDY TYPE: Control/cohort. POPULATION: Twenty-five MS patients and 18 healthy controls (HC). FIELD STRENGTH/SEQUENCE: 3T/ViSTa and GRASE-MWI. ASSESSMENT: Using ViSTa and GRASE-MWI, myelin water fraction (MWF) of NAWM or normal WM was compared between MS (all patients or early-stage MS patients) and HC. The comparison was performed for a global WM mask and five regional WM masks. STATISTICAL TESTS: A general linear model was applied for the comparison. A statistical power and a minimum sample size for the significant difference were obtained. Spearman's correlation coefficient was calculated between MWF and clinical measures and between ViSTa-MWF and GRASE-MWF for the global WM mask. RESULTS: MWFs of ViSTa were significantly lower in the MS patients than those in the HC in all masks (P < 0.001). GRASE-MWI results revealed reduced MWFs only in global WM, genu, and optic radiation. ViSTa-MWI had higher statistical powers than that of GRASE-MWI (power: ViSTa = 99.2 ± 1.6% and GRASE = 75.5 ± 31.0%; sample size: ViSTa = 18 ± 9 and GRASE = 78 ± 75). In early-stage MS, MWFs of ViSTa were significantly lower than those of the HC in all masks except for centrum semiovale; however, MWFs of GRASE MWI were significantly lower only in optic radiation. Disease duration was correlated with both MWIs (ViSTa; r = -0.437 and GRASE; r = -0.445). ViSTa and GRASE MWFs were significantly correlated in the HC (r = 0.664) and MS (r = 0.768). DATA CONCLUSION: ViSTa-MWI may detect a reduction of MWF in NAWM of MS. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1091-1098.


Assuntos
Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Bainha de Mielina/química , Água/química , Adulto , Algoritmos , Estudos de Casos e Controles , Corpo Caloso/diagnóstico por imagem , Doenças Desmielinizantes/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Substância Branca/diagnóstico por imagem , Adulto Jovem
12.
Neuroimage ; 168: 242-249, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-27633800

RESUMO

As the use of ultra-high field (UHF; ≥7T) magnetic resonance (MR) imaging expands, there is an increasing need to establish high-resolution MR imaging protocols for patients with neurological disease. Magnetization transfer (MT) imaging has been used to provide information about changes in the magnitude of the restricted protons that are caused by tissue damages. Several studies have found that MTR has a good sensitivity to measure changes in myelin concentration within the brain. Because of the much higher specific absorption rate (SAR) of tissue and longer acquisition time required for UHF, however, in-vivo studies using conventional pulsed MT sequences at UHF have not been well utilized. In this study, we introduce a new MT data acquisition approach using a 7T MR system, variable density magnetization transfer (vdMT) imaging, which can be reasonably included in a routine patient scan protocol with a much shorter scan time and reduced discomfort to the patient. To reduce SAR and scan time while maintaining at least similar MTR image quality to that obtained with the conventional method, a higher density of MT RF pulses was applied in the center of k-space, and sparsely applied MT RF pulses were used in the outer part of k-space. The fraction of k-space receiving 100% MT RF density and TR were optimized based on in-vivo ROI analysis, and results were confirmed with high-resolution MTR map using a vdMT approach from healthy controls and patients with multiple sclerosis (MS). The experimental results confirmed that vdMT imaging can cover a whole brain volume in an acceptable scan time for routine patient scans while providing MTR image quality at least similar to that obtained with conventional MT imaging (correlation coefficient=0.95 in an agar-gel phantom [MT offset frequency=1kH], 0.90 in a postmortem MS brain, and 0.85 in the 4 healthy volunteers). MS lesions were associated with signal reductions in the postmortem MS brains and in the patients with MS. In this study, we have described a new approach for acquiring high-resolution MTR map of the whole brain volume using 7T MR imaging. This vdMT method provides similar image quality to that obtained with the conventional method, and shortens the scan time by reducing SAR. These results suggest that vdMT approach is a method that could be used for UHF scans of patients with neurological disease.


Assuntos
Encéfalo/diagnóstico por imagem , Fenômenos Magnéticos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Humanos , Imagens de Fantasmas
13.
Neuroimage ; 182: 379-388, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28962901

RESUMO

MR g-ratio, which measures the ratio of the aggregate volume of axons to that of fibers in a voxel, is a potential biomarker for white matter microstructures. In this study, a new approach for acquiring an in-vivo whole human brain g-ratio map is proposed. To estimate the g-ratio, myelin volume fraction and axonal volume fraction are acquired using multi-echo gradient echo myelin water imaging (GRE-MWI) and neurite orientation dispersion and density imaging (NODDI), respectively. In order to translate myelin water fraction measured in GRE-MWI into myelin volume fraction, a new scaling procedure is proposed and validated. This scaling approach utilizes geometric measures of myelin structure and, therefore, provides robustness over previous methods. The resulting g-ratio map reveals an expected range of g-ratios (0.71-0.85 in major fiber bundles) with a small inter-subject coefficient of variance (less than 2%). Additionally, a few fiber bundles (e.g. cortico-spinal tract and optic radiation) show different constituents of myelin volume fraction and axonal volume fraction, indicating potentials to utilize the measures for deciphering fiber tracking.


Assuntos
Água Corporal/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Bainha de Mielina , Neuritos , Neuroimagem/métodos , Substância Branca/diagnóstico por imagem , Adulto , Humanos
14.
Neuroimage ; 168: 459-476, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-27915116

RESUMO

PURPOSE: There have been an increasing number of studies involving ultra-high-field 7T of intracranial pathology, however, comprehensive clinical studies of neuropathology at 7T still remain limited. 7T has the advantage of a higher signal-to-noise ratio and a higher contrast-to-noise ratio, compared to current low field clinical MR scanners. We hypothesized 7T applied clinically, may improve detection and characterization of intracranial pathology. MATERIALS AND METHODS: We performed an IRB-approved 7T prospective study of patients with neurological disease who previously had lower field 3T and 1.5T. All patients underwent 7T scans, using comparable clinical imaging protocols, with the aim of qualitatively comparing neurological lesions at 7T with 3T or 1.5T. To qualitatively assess lesion conspicuity at 7T compared with low field, 80-paired images were viewed by 10 experienced neuroradiologists and scored on a 5-point scale. Inter-rater agreement was characterized using a raw percent agreement and mean weighted kappa. RESULTS: One-hundred and four patients with known neurological disease have been scanned to date. Fifty-five patients with epilepsy, 18 patients with mild traumatic brain injury, 11 patients with known or suspected multiple sclerosis, 9 patients with amyotrophic lateral sclerosis, 4 patients with intracranial neoplasm, 2 patients with orbital melanoma, 2 patients with cortical infarcts, 2 patients with cavernous malformations, and 1 patient with cerebral amyloid angiopathy. From qualitative observations, we found better resolution and improved detection of lesions at 7T compared to 3T. There was a 55% raw inter-rater agreement that lesions were more conspicuous on 7T than 3T/1.5T, compared with a 6% agreement that lesions were more conspicuous on 3T/1.5T than 7T. CONCLUSION: Our findings show that the primary clinical advantages of 7T magnets, which include higher signal-to-noise ratio, higher contrast-to-noise ratio, smaller voxels and stronger susceptibility contrast, may increase lesion conspicuity, detection and characterization compared to low field 1.5T and 3T. However, low field which detects a plethora of intracranial pathology remains the mainstay for diagnostic imaging until limitations at 7T are addressed and further evidence of utility provided.


Assuntos
Encefalopatias/diagnóstico por imagem , Encefalopatias/patologia , Imageamento por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Estudos Prospectivos
15.
Neuroimage ; 162: 269-275, 2017 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28823825

RESUMO

Myelin, which consists of lipid bilayers, is one of the major constituents of white matter in the brain and has been suggested as a primary source of magnetic susceptibility contrasts. In this study, a new R2* model that simultaneously explains the effects of fiber orientation and myelin concentration is proposed and tested. In addition, a new approach that produces R2* maps without the effects of myelin is suggested. Experimental results demonstrate that the model reveals a high goodness of fit for the R2* distribution of white matter compared to a model that explains either fiber orientation or myelin concentration. The proposed R2* map shows a relatively uniform spatial distribution of R2* compared to the uncorrected R2* map and the fiber orientation or myelin concentration corrected R2* map.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/citologia , Processamento de Imagem Assistida por Computador/métodos , Fibras Nervosas Mielinizadas , Substância Branca/diagnóstico por imagem , Adulto , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Masculino , Adulto Jovem
16.
NMR Biomed ; 30(4)2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27060968

RESUMO

In MRI, structurally aligned molecular or micro-organization (e.g. axonal fibers) can be a source of substantial signal variations that depend on the structural orientation and the applied magnetic field. This signal anisotropy gives us a unique opportunity to explore information that exists at a resolution several orders of magnitude smaller than that of typical MRI. In this review, one of the signal anisotropies, T2 * anisotropy in white matter, and a related imaging method, gradient echo myelin water imaging (GRE-MWI), are explored. The T2 * anisotropy has been attributed to isotropic and anisotropic magnetic susceptibility of myelin and compartmentalized microstructure of white matter fibers (i.e. axonal, myelin, and extracellular space). The susceptibility and microstructure create magnetic frequency shifts that change with the relative orientation of the fiber and the main magnetic field, generating the T2 * anisotropy. The resulting multi-component magnitude decay and nonlinear phase evolution have been utilized for GRE-MWI, assisting in resolving the signal fraction of the multiple compartments in white matter. The GRE-MWI method has been further improved by signal compensation techniques including physiological noise compensation schemes. The T2 * anisotropy and GRE-MWI provide microstructural information on a voxel (e.g. fiber orientation and tissue composition), and may serve as sensitive biomarkers for microstructural changes in the brain. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Água Corporal/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Imagem Molecular/métodos , Bainha de Mielina/ultraestrutura , Substância Branca/diagnóstico por imagem , Anisotropia , Água Corporal/química , Água Corporal/citologia , Química Encefálica , Humanos , Bainha de Mielina/química , Substância Branca/química
17.
Magn Reson Med ; 74(2): 499-505, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25154599

RESUMO

PURPOSE: To demonstrate the phase evolutions of direct visualization of short transverse relaxation time component (ViSTa) matches with those of myelin water. METHOD: Myelin water imaging (MWI) measures short transverse signals and has been suggested as a biomarker for myelin. Recently, a new approach, ViSTa, has been proposed to acquire short T2* signals by suppressing long T1 signals. This method does not require any ill-conditioned data processing and therefore provides high-quality images. In this study, the phase of the ViSTa signal was compared with the phase of myelin water simulated by the magnetic susceptibility model of hollow cylinder. RESULTS: The phase evolutions of the ViSTa signal were similar to the simulated myelin water phase evolutions. When fiber orientation was perpendicular relative to the main magnetic field, both the ViSTa and the simulated myelin water phase showed large positive frequency shifts, whereas the gradient echo phase showed a slightly negative frequency shift. Additionally, the myelin water phase map generated using diffusion tensor imaging (DTI) information revealed a good match with the ViSTa phase image. CONCLUSION: The results of this study support the origin of ViSTa signal as myelin water. ViSTa phase may potentially provide sensitivity to demyelination.


Assuntos
Imagem de Tensor de Difusão/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Bainha de Mielina/metabolismo , Fibras Nervosas Mielinizadas/metabolismo , Fibras Nervosas Mielinizadas/ultraestrutura , Algoritmos , Biomarcadores/metabolismo , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Magn Reson Med ; 72(2): 452-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24105838

RESUMO

PURPOSE: To introduce novel acquisition and postprocessing approaches for susceptibility weighted imaging (SWI) to remove background field inhomogeneity artifacts in both magnitude and phase data. METHODS: The proposed method acquires three echoes in a three-dimensional gradient echo (GRE) sequence, with a field compensation gradient (z-shim gradient) applied to the third echo. The artifacts in the magnitude data are compensated by signal estimation from all three echoes. The artifacts in phase signals are removed by modeling the background phase distortions using Gaussians. The method was applied in vivo and compared with conventional SWI. RESULTS: The method successfully compensates for background field inhomogeneity artifacts in magnitude and phase images, and demonstrated improved SWI images. In particular, vessels in frontal lobe, which were not observed in conventional SWI, were identified in the proposed method. CONCLUSION: The new method improves image quality in SWI by restoring signal in the frontal and temporal regions.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Magn Reson Med Sci ; 23(3): 291-306, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38644201

RESUMO

In MRI, researchers have long endeavored to effectively visualize myelin distribution in the brain, a pursuit with significant implications for both scientific research and clinical applications. Over time, various methods such as myelin water imaging, magnetization transfer imaging, and relaxometric imaging have been developed, each carrying distinct advantages and limitations. Recently, an innovative technique named as magnetic susceptibility source separation has emerged, introducing a novel surrogate biomarker for myelin in the form of a diamagnetic susceptibility map. This paper comprehensively reviews this cutting-edge method, providing the fundamental concepts of magnetic susceptibility, susceptibility imaging, and the validation of the diamagnetic susceptibility map as a myelin biomarker that indirectly measures myelin content. Additionally, the paper explores essential aspects of data acquisition and processing, offering practical insights for readers. A comparison with established myelin imaging methods is also presented, and both current and prospective clinical and scientific applications are discussed to provide a holistic understanding of the technique. This work aims to serve as a foundational resource for newcomers entering this dynamic and rapidly expanding field.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Bainha de Mielina , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
20.
Mult Scler J Exp Transl Clin ; 10(2): 20552173241240937, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38715892

RESUMO

Background: Cognitive dysfunction is a known symptom of multiple sclerosis (MS), with memory recognized as a frequently impacted domain. Here, we used high-resolution MRI at 7 tesla to build on cross-sectional work by evaluating the longitudinal relationship of diffusion tensor imaging (DTI) measures of the fornix to episodic memory performance. Methods: A sample of 80 people with multiple sclerosis (mean age 51.9 ± 8.1 years; 24% male) underwent baseline clinical evaluation, neuropsychological assessment, and MRI. Sixty-four participants had follow-up neuropsychological testing after 1-2 years. Linear regression was used to assess the relationship of baseline imaging measures to follow-up episodic memory performance, measured using the Selective Reminding Test and Brief Visuospatial Memory Test. A reduced prediction model included cognitive function at baseline, age, sex, and disease course. Results: Radial (ß = -0.222, p < 0.026; likelihood ratio test (LRT) p < 0.018), axial (ß = -0.270, p < 0.005; LRT p < 0.003), and mean (ß = -0.242, p < 0.0139; LRT p < 0.009) diffusivity of the fornix significantly added to the model, with follow-up analysis indicating that a longer prediction interval may increase accuracy. Conclusion: These results suggest that fornix DTI has predictive value specific to memory function in MS and warrants additional investigation in the drive to develop predictors of disease progression.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa