Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Appl Opt ; 57(36): 10541-10547, 2018 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-30645402

RESUMO

To measure the 3D microdisplacement of a self-oscillating polymer gel driven by the Belousov-Zhabotinsky reaction, we propose, to the best of our knowledge, a new particle detection and tracking method based on a phase image/volume template matching using digital holographic microscopy. We demonstrate the precision of the proposed method and compare it with conventional approaches. The method is applied to 3D measurement of the motions of particles attached to the surface of an oscillating gel. Measurement results show that the local area of the gel oscillates periodically, and the motion propagates throughout the gel. Our method can measure rapid and complex 3D microdisplacement change.

2.
PLoS One ; 17(4): e0267677, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35482658

RESUMO

Morphological changes in the upper airway and the resulting alteration in the nasal respiratory function after jawbone repositioning during orthognathic surgery have garnered attention recently. In particular, nasopharyngeal stenosis, because of the complex influence of both jaws, the effects of which have not yet been clarified owing to postero-superior repositioning of the maxilla, may significantly impact sleep and respiratory function, necessitating further functional evaluation. This study aimed to perform a functional evaluation of the effects of surgery involving maxillary repositioning, which may result in a larger airway resistance if the stenosis worsens the respiratory function, using CFD for treatment planning. A model was developed from CT images obtained preoperatively (PRE) and postoperatively (POST) in females (n = 3) who underwent maxillary postero-superior repositioning using Mimics and ICEM CFD. Simultaneously, a model of stenosis (STENOSIS) was developed by adjusting the severity of stenosis around the PNS to simulate greater repositioning than that in the POST. Inhalation at rest and atmospheric pressure were simulated in each model using Fluent, whereas pressure drop (ΔP) was evaluated using CFD Post. In this study, ΔP was proportional to airway resistance because the flow rate was constant. Therefore, the magnitude of ΔP was evaluated as the level of airway resistance. The ΔP in the airway was lower in the POST compared to the PRE, indicating that the analysis of the effects of repositioning on nasal ventilation showed that current surgery is appropriate with respect to functionality, as it does not compromise respiratory function. The rate of change in the cross-sectional area of the mass extending pharynx (α) was calculated as the ratio of each neighboring section. The closer the α-value is to 1, the smaller the ΔP, so ideally the airway should be constant. This study identified airway shapes that are favorable from the perspective of fluid dynamics.


Assuntos
Biologia Computacional , Hidrodinâmica , Maxila , Constrição Patológica , Feminino , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Faringe
3.
Micromachines (Basel) ; 12(5)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33922099

RESUMO

Oscillatory flow has many applications in micro-scaled devices. The methods of realizing microfluidic oscillators reported so far are typically based on the impinging-jet and Coanda effect, which usually require the flow Reynolds number to be at least at the order of unity. Another approach is to introduce elastomeric membrane into the microfluidic units; however, the manufacturing process is relatively complex, and the membrane will become soft after long-time operation, which leads to deviation from the design condition. From the perspective of the core requirement of a microfluidic circuit, i.e., nonlinearity, the oscillatory microfluidic flow can be realized via the nonlinear characteristics of viscoelastic fluid flow. In this paper, the flow characteristics of viscoelastic fluid (Boger-type) in a T-shaped channel and its modified structures are studied by two-dimensional direct numerical simulation (DNS). The main results obtained from the DNS study are as follows: (1) Both Weissenberg (Wi) number and viscosity ratio need to be within a certain range to achieve a periodic oscillating performance; (2) With the presence of the dynamic evolution of the pair of vortices in the upstream near the intersection, the oscillation intensity increases as the elasticity-dominated area in the junction enlarges; (3) Considering the simplicity of the T-type channel as a potential oscillator, the improved structure should have a groove carved toward the entrance near the upper wall. The maximum oscillation intensity measured by the standard deviation of flow rate at outlet is increased by 129% compared with that of the original standard T-shaped channel under the same condition. To sum up, with Wi number and viscosity ratio within a certain range, the regular periodic oscillation characteristics of Oldroyd-B type viscoelastic fluid flow in standard T-shaped and its modified channels can be obtained. This structure can serve as a passive microfluidic oscillator with great potential value at an extremely low Reynolds number, which has the advantages of simplicity, no moving parts and fan-out of two.

4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 63(1): 75-84, 2007 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-17344636

RESUMO

It has been noted that the downtime of medical informatics systems is often long. Many systems encounter downtimes of hours or even days, which can have a critical effect on daily operations. Such systems remain especially weak in the areas of database and medical imaging data. The scheme design shows the three-layer architecture of the system: application, database, and storage layers. The application layer uses the DICOM protocol (Digital Imaging and Communication in Medicine) and HTTP (Hyper Text Transport Protocol) with AJAX (Asynchronous JavaScript+XML). The database is designed to decentralize in parallel using cluster technology. Consequently, restoration of the database can be done not only with ease but also with improved retrieval speed. In the storage layer, a network RAID (Redundant Array of Independent Disks) system, it is possible to construct exabyte-scale parallel file systems that exploit storage spread. Development and evaluation of the test-bed has been successful in medical information data backup and recovery in a network environment. This paper presents a schematic design of the new medical informatics system that can be accommodated from a recovery and the dynamic Web application for medical imaging distribution using AJAX.


Assuntos
Armazenamento e Recuperação da Informação/métodos , Internet , Sistemas de Informação em Radiologia , Software , Bases de Dados como Assunto , Humanos , Design de Software , Telerradiologia
5.
Biomicrofluidics ; 3(1): 14105, 2009 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-19693398

RESUMO

Understanding the biological feeding strategy and characteristics of a microorganism as an actuator requires the detailed and quantitative measurement of flow velocity and flow rate induced by the microorganism. Although some velocimetry methods have been applied to examine the flow, the measured dimensions were limited to at most two-dimensional two-component measurements. Here we have developed a method to measure three-dimensional two-component flow velocity fields generated by the microorganism Vorticella picta using a piezoscanner and a confocal microscope. We obtained the two-component velocities of the flow field in a two-dimensional plane denoted as the XY plane, with an observation area of 455x341 mum(2) and the resolution of 9.09 mum per each velocity vector by a confocal microparticle image velocimetry technique. The measurement of the flow field at each height took 37.5 ms, and it was repeated in 16 planes with a 2.50 mum separation in the Z direction. We reconstructed the three-dimensional two-component flow velocity field. From the reconstructed data, the flow velocity field [u((x,y,z)),v((x,y,z))] in an arbitrary plane can be visualized. The flow rates through YZ and ZX planes were also calculated. During feeding, we examined a suction flow to the mouth of the Vorticella picta and measured it to be to 300 pls.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa