Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Oncologist ; 26(7): e1250-e1255, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33928712

RESUMO

The Japanese Ministry of Health, Labour and Welfare approved a drug called borofalan (10 B), a treatment system, and a dose calculation program for boron neutron capture therapy (BNCT) in March 2020. The application pertaining to the products submitted to the Pharmaceuticals and Medical Devices Agency was supported by a Japanese, open-label, uncontrolled trial (Study 002) in patients with unresectable, locally recurrent head and neck squamous cell carcinoma after chemoradiotherapy or radiotherapy, or in those with unresectable locally advanced or locally recurrent (LA/LR) head and neck nonsquamous cell carcinoma. The drug was administered as a single intravenous dose using infusion rates of 200 mg/kg per hour for the first 2 hours after the start of administration and 100 mg/kg per hour during irradiation. Neutron irradiation was performed using the devices at a single dose of 12 Gy-equivalent for oral, pharyngeal, or laryngeal mucosa for up to 60 minutes from 2 hours after the start of drug administration. The primary endpoint was the overall response rate (ORR). The results of Study 002 showed that the ORR based on an assessment of the Independent Central Review Committee per RECIST version 1.1 was 71.4% (90% confidence interval [CI], 51.3%-86.8%). The lower limit of the 90% CI exceeded the prespecified threshold for ORR. When BNCT is applied to patients with unresectable LA/LR head and neck cancer, precautions should be taken, and patients should be monitored for possible onset of dysphagia, brain abscess, skin disorder, crystal urine, cataract, and/or carotid hemorrhage. IMPLICATIONS FOR PRACTICE: Borofalan (10 B), a treatment system and a dose calculation program for boron neutron capture therapy (BNCT), demonstrated significant efficacy in an open-label, uncontrolled trial in which overall response rate was the primary endpoint for patients with unresectable locally advanced or locally recurrent head and neck cancer. Although no information about survival benefits was obtained, BNCT will become an effective treatment option that is expected to manage local lesions that are intractable with any standard therapy. In addition, BNCT is expected to maintain quality of life of the intended patient population, on account of its high tumor selectivity and low invasiveness.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Recidiva Local de Neoplasia/radioterapia , Qualidade de Vida , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia
2.
Ther Innov Regul Sci ; 57(1): 104-108, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994203

RESUMO

With the rapid technological innovations of the Internet of Things (IoT), the situation surrounding medical devices and medical systems has been changing. Interoperable medical devices-medical devices capable of interoperating in a clinically significant way with other medical devices-have been developed, and interoperable medical systems consisting of two or more interconnected interoperable medical devices are being used in clinical settings. However, general points that need to be considered to ensure safe and effective interoperability have yet to be fully established in Japan. A research project (FY2019-FY2021) to discuss issues associated with ensuring safe and effective interoperability was commissioned by the Japan Agency for Medical Research and Development. A pivotal aspect identified in that project is how to manage the sharing of data and information among interoperable medical devices from different manufacturers. Characteristics and timestamps of data and information need to be exchanged between interoperable medical devices. Risks associated with interoperable devices should be managed in a manner appropriate to the characteristics and the intended use of the interoperable medical devices. In this review, we summarize the aspects of data and information that this study group judged were important to consider for ensuring safety and effective interoperability.


Assuntos
População do Leste Asiático , Humanos , Japão
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa