Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 380
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Retina ; 44(4): 652-658, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064668

RESUMO

PURPOSE: To investigate the 5-year treatment outcomes of retinopathy of prematurity in infants <500 g birth weight and compare laser and anti-vascular endothelial growth factor therapies. METHODS: A multicenter retrospective study comprised 24 eyes of 13 patients treated for Type 1 retinopathy of prematurity, followed for 5 years. Initial treatment was laser and anti-vascular endothelial growth factor in 13 and 11 eyes, respectively. Data collected included sex, birth characteristics, retinopathy of prematurity characteristics at the time of treatment, best-corrected visual acuity (BCVA), spherical equivalent, and astigmatism at 5 years posttreatment. RESULTS: Median BCVA was 0.15 logarithm of the minimum angle of resolution (interquartile range, 0.0-0.5). Snellen BCVA was ≥20/40 in 73% and ≥20/20 in 27% of eyes. Median spherical equivalent was -2.37 (interquartile range, -6.1 to -0.1); 75% had myopia (≤-0.5 D), and 25% had high myopia (≤-6.0 D). Median astigmatism was 1.25 (interquartile range, 0.9-3.0); 46% had ≥1.5 D. Anti-vascular endothelial growth factor-treated eyes showed less myopia ( P < 0.009), with no BCVA or astigmatism difference ( P = 0.997, P = 0.271) compared with laser-treated eyes. CONCLUSION: One-quarter of the eyes exhibited good visual acuity (Snellen BCVA of ≥20/20) 5 years after retinopathy of prematurity treatment. Refractive errors were common. Anti-vascular endothelial growth factor therapy may be superior to laser therapy in myopic refractive error.


Assuntos
Astigmatismo , Miopia , Erros de Refração , Retinopatia da Prematuridade , Recém-Nascido , Lactente , Humanos , Astigmatismo/terapia , Retinopatia da Prematuridade/cirurgia , Estudos Retrospectivos , Fatores de Crescimento Endotelial , Resultado do Tratamento , Fotocoagulação a Laser
2.
Ophthalmologica ; 247(2): 107-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38408439

RESUMO

INTRODUCTION: We compared postoperative metamorphopsia and optical coherence tomography (OCT) findings between eyes that underwent internal limiting membrane (ILM) peeling and the inverted flap (IF) technique for macular hole (MH). METHODS: This retrospective analysis included 64 eyes of 64 patients with idiopathic MH whose MH was closed after initial surgery. Thirty-nine patients were treated with pars plana vitrectomy (PPV) with ILM peeling, and 25 patients were treated with PPV with the IF technique. Best corrected visual acuity (BCVA), severity of metamorphopsia, and OCT images were collected before and 3, 6, and 12 months postoperatively. Based on the OCT images, the status of the external limiting membrane (ELM) and ellipsoid zone and the presence of hyperreflective plugs were assessed. RESULTS: At baseline and 3, 6, and 12 months postoperatively, BCVA and severity of metamorphopsia were not significantly different between groups. The status of the ELM was significantly worse in the IF group than in the ILM peeling group at 3 and 6 months postoperatively. Significantly more hyperreflective plugs were observed in the IF group than in the ILM peeling group at 3 and 6 months postoperatively. Stepwise multiregression analysis revealed that hyperreflective plugs were significantly associated with the severity of metamorphopsia at 12 months postoperatively. DISCUSSION/CONCLUSION: The alterations on the OCT were fewer in the ILM peeling group than in the IF group, while no significant differences were observed in postoperative severity of metamorphopsia between groups. Metamorphopsia was worse in eyes with hyperreflective plugs.


Assuntos
Membrana Basal , Perfurações Retinianas , Retalhos Cirúrgicos , Tomografia de Coerência Óptica , Transtornos da Visão , Acuidade Visual , Vitrectomia , Humanos , Tomografia de Coerência Óptica/métodos , Perfurações Retinianas/cirurgia , Perfurações Retinianas/diagnóstico , Estudos Retrospectivos , Feminino , Masculino , Vitrectomia/métodos , Membrana Basal/cirurgia , Idoso , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Transtornos da Visão/etiologia , Seguimentos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Membrana Epirretiniana/cirurgia , Membrana Epirretiniana/diagnóstico
3.
Proc Natl Acad Sci U S A ; 118(6)2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33526699

RESUMO

Alu retroelements propagate via retrotransposition by hijacking long interspersed nuclear element-1 (L1) reverse transcriptase (RT) and endonuclease activities. Reverse transcription of Alu RNA into complementary DNA (cDNA) is presumed to occur exclusively in the nucleus at the genomic integration site. Whether Alu cDNA is synthesized independently of genomic integration is unknown. Alu RNA promotes retinal pigmented epithelium (RPE) death in geographic atrophy, an untreatable type of age-related macular degeneration. We report that Alu RNA-induced RPE degeneration is mediated via cytoplasmic L1-reverse-transcribed Alu cDNA independently of retrotransposition. Alu RNA did not induce cDNA production or RPE degeneration in L1-inhibited animals or human cells. Alu reverse transcription can be initiated in the cytoplasm via self-priming of Alu RNA. In four health insurance databases, use of nucleoside RT inhibitors was associated with reduced risk of developing atrophic macular degeneration (pooled adjusted hazard ratio, 0.616; 95% confidence interval, 0.493-0.770), thus identifying inhibitors of this Alu replication cycle shunt as potential therapies for a major cause of blindness.


Assuntos
Elementos Alu/genética , Elementos Nucleotídeos Longos e Dispersos/genética , Degeneração Macular/genética , Pigmentos da Retina/metabolismo , Animais , Citoplasma/genética , DNA Complementar/genética , Epitélio/metabolismo , Epitélio/patologia , Humanos , Degeneração Macular/patologia , Pigmentos da Retina/biossíntese , Retroelementos/genética , Transcrição Reversa/genética
4.
Eye Contact Lens ; 49(4): 172-177, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36848188

RESUMO

OBJECTIVES: Previous studies have shown that combined use of orthokeratology and 0.01% atropine (AT) eye drops can strongly prevent axial elongation in myopic children. However, the efficacy of combined use with multifocal contact lens (MFCL) and 0.01% AT remains unclear. The aim of this trial is to clarify the efficacy of MFCL+0.01% AT combination therapy for myopia control and safety. METHODS: This prospective study is a randomized, double-masked, placebo-controlled trial with four arms. A total of 240 children aged 6 to 12 years with myopia is recruited and randomly assigned to one of the four groups in a ratio of 1:1:1:1 as follows: group 1: MFCL+AT combination therapy, group 2: MFCL monotherapy, group 3: AT monotherapy, and group 4: placebo. The participants will continue the assigned treatment for 1 year. The primary and secondary outcomes are the comparisons of axial elongation and myopia progression in the four groups during the 1-year study period. DISCUSSION: The present trial would determine whether the MFCL+AT combination therapy is more effective in slowing axial elongation and myopia progression in schoolchildren as compared with each monotherapy or placebo, and it also confirm acceptable safety of the combination therapy.


Assuntos
Lentes de Contato , Miopia , Criança , Humanos , Atropina/uso terapêutico , Soluções Oftálmicas/uso terapêutico , Estudos Prospectivos , Refração Ocular , Miopia/tratamento farmacológico , Miopia/prevenção & controle , Comprimento Axial do Olho , Progressão da Doença , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Exp Eye Res ; 223: 109206, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35921961

RESUMO

Multiple intravitreal injections, which are painful and costly, are often required in the treatment of retinal disorders. Therefore, a novel drug delivery system using hydrogels is currently being evaluated as an alternative. This study aimed to evaluate the ability of tetra-armed polyethylene glycol (tetra-PEG) gel for sustained release in vitro. Bevacizumab-loaded tetra-PEG gel and 5-Carboxyfluorescein N-succinimidyl ester (FAM-NHS)-labeled IgG-loaded tetra-PEG gel were prepared by mixing tetra-PEG with thiol termini (tetra-PEG-SH) solution, maleimide termini (tetra-PEG-MA) solution, and bevacizumab or FAM-NHS labeled IgG. The gels were prepared with three different polymer concentrations of 1.5%, 5%, and 10%, then an in vitro release study performed to assess the sustained release ability of the drug-loaded tetra-PEG gels. High performance liquid chromatography (HPLC) was used to test the structural stability of the bevacizumab released from the tetra-PEG gel. The binding of bevacizumab to tetra-PEG-SH or MA was assessed using SDS-polyacrylamide gel electrophoresis (PAGE). The bioactivity of released bevacizumab was tested using KDR/NFAT-RE HEK293 cells. In addition, in vitro degradation and swelling studies were also performed. The in vitro release analysis showed that the release of bevacizumab was slower in the 5% and 10% tetra-PEG gels than that of 1.5% tetra-PEG gels. Similarly, the release of FAM-NHS-labeled IgG was slowest in the 1.5%, 5%, and 10% tetra-PEG gels, in that order. The 5% and 10% tetra-PEG gels released bevacizumab and FAM-NHS-labeled IgG over a period of 1-2 weeks. Both bevacizumab and FAM-NHS-labeled IgG were not fully released in 2 weeks. HPLC analysis showed that the retention time of the samples released from the bevacizumab-loaded tetra-PEG gel was similar to that of the bevacizumab standard. The SDS-PAGE analysis showed that bevacizumab binds to tetra-PEG-MA. The bioactivity assay test revealed no decrease in the bioactivity of the released bevacizumab. In vitro degradation and swelling studies revealed that 1.5%, 5%, and 10% tetra-PEG gels expanded by approximately 1.4-, 2-, and 3-fold, respectively. Based on the results of the release and swelling tests, 5% tetra-PEG gels are considered good candidates for controlled release systems for therapeutic antibodies such as bevacizumab. The binding of PEG to the therapeutic antibodies may reduce the availability of therapeutic antibodies that can be released.


Assuntos
Hidrogéis , Polietilenoglicóis , Bevacizumab , Preparações de Ação Retardada , Ésteres , Células HEK293 , Humanos , Imunoglobulina G , Maleimidas/química , Polietilenoglicóis/química , Polímeros/química , Compostos de Sulfidrila
6.
BMC Ophthalmol ; 22(1): 81, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35177028

RESUMO

BACKGROUND: A simple technique to facilitate removal of subincisional cortex in cataract surgery is presented. METHODS: A disposable 27-gauge blunt needle attached to a 5.0-ml syringe containing balanced salt solution (BSS) is introduced through the side port incision into the anterior chamber. The tip of the needle is directed toward the capsule fornix beneath the incision site, and BSS is flushed to disperse the remaining cortex. Thereafter, the coaxial irrigation/aspiration device is used to remove the loosened cortex. RESULTS: This technique was used in 60 eyes of 60 patients with difficulty of removing cortical remnant in the subincisional space. Subincisional cortical material was successfully removed in 93.3% (56/60 eyes). There were no intraoperative and postoperative complications related to this procedure. CONCLUSIONS: The hydro-dispersion technique is a simple and safe approach to remove the subincisional cortical material that is difficult to manage with the standard coaxial irrigation/aspiration device.


Assuntos
Extração de Catarata , Cristalino , Facoemulsificação , Câmara Anterior/cirurgia , Extração de Catarata/métodos , Humanos , Facoemulsificação/métodos , Complicações Pós-Operatórias/cirurgia , Irrigação Terapêutica/métodos
7.
Graefes Arch Clin Exp Ophthalmol ; 259(9): 2849-2855, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33744981

RESUMO

PURPOSE: To compare laser photocoagulation and intravitreal injection of bevacizumab (IVB) treatment for retinopathy of prematurity (ROP). METHODS: The study included 52 eyes of 26 patients after ROP treatment who were observed up to 5 years of age. Twenty-eight eyes received laser photocoagulation as the initial treatment (laser group), and twenty-four eyes underwent IVB (IVB group). We collected data on gestational age, birth weight, 1- and 5-min Apgar scores, zone and stage at the time of treatment, recurrence of ROP and best-corrected visual acuity (BCVA) (logMAR), equivalent spherical value (SE), ocular complications, and developmental delay at the age of 5. RESULTS: More zone I low-stage eyes were treated with IVB than laser. There was no difference in BCVA (p = 0.836). Although the mean SE was not different between the groups (p = 0.280), the prevalence of myopia was significantly higher in the laser group (p = 0.020). Developmental delay was observed in 3 of 14 and 3 of 12 cases in the laser and IVB groups, respectively (p = 0.596). Retinal holes were observed in 2 eyes in the IVB group, with 1 developing localized retinal detachment. There were no significant differences between the groups in the other factors. CONCLUSIONS: Compared to laser for ROP, IVB was not inferior in neurodevelopment or visual outcome and was superior in refractive error. As cases in the IVB group showed retinal holes, long-term follow-up with fundus examination is recommended after IVB.


Assuntos
Retinopatia da Prematuridade , Inibidores da Angiogênese/uso terapêutico , Bevacizumab/uso terapêutico , Idade Gestacional , Humanos , Recém-Nascido , Injeções Intravítreas , Fotocoagulação a Laser , Lasers , Retinopatia da Prematuridade/diagnóstico , Retinopatia da Prematuridade/tratamento farmacológico , Retinopatia da Prematuridade/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular
8.
Graefes Arch Clin Exp Ophthalmol ; 258(4): 743-749, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32080768

RESUMO

PURPOSE: To investigate stereopsis and other visual functions in patients with unilateral epiretinal membrane (ERM) and to identify vision-related parameters affecting stereopsis. METHODS: This prospective study included 63 consecutive patients who were scheduled to undergo vitrectomy for unilateral idiopathic ERM. We examined stereopsis (Titmus Stereo Test, TST; TNO stereotest, TNO), best-corrected visual acuity (BCVA), letter contrast sensitivity, severity of metamorphopsia, and degree of aniseikonia preoperatively and 6 months postoperatively. RESULTS: Preoperatively, we observed significant correlation between TST scores and other vision-related parameters except severity of metamorphopsia and between TNO score and all the vision-related parameters. Multiple regression analysis showed that preoperative TST and TNO scores were significantly associated with the degree of aniseikonia (both P < 0.01). ERM surgery significantly improved stereopsis, BCVA, contrast sensitivity, and metamorphopsia, but not aniseikonia. Postoperatively, TST was significantly associated with BCVA, and TNO showed association with BCVA and aniseikonia. Postoperative TST and TNO scores showed significant correlation with preoperative aniseikonia (P < 0.005 and P < 0.001, respectively). CONCLUSIONS: Impairment of stereopsis in patients with unilateral ERM was considered to be due to retinally induced aniseikonia. Aniseikonia did not improve by surgery, and preoperative aniseikonia can be a prognostic factor for postoperative stereopsis.


Assuntos
Aniseiconia/diagnóstico , Percepção de Profundidade/fisiologia , Membrana Epirretiniana/cirurgia , Retina/patologia , Acuidade Visual , Vitrectomia/métodos , Idoso , Membrana Epirretiniana/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Período Pós-Operatório , Período Pré-Operatório , Prognóstico , Estudos Prospectivos , Tomografia de Coerência Óptica
9.
Graefes Arch Clin Exp Ophthalmol ; 258(1): 137-146, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31631237

RESUMO

PURPOSE: This study was performed to compare anterior ocular biometric measurements of deep-range swept-source anterior segment optical coherence tomography (AS-OCT) (CASIA2) versus short-range swept-source AS-OCT (CASIA SS-1000), ultrasonography (AL-4000), and Scheimpflug camera analysis (Pentacam and EAS-1000) in patients with cataract. METHODS: One hundred eighty-five eyes of 128 participants with mild refractive error or cataract were examined. The central corneal thickness (CCT), aqueous depth (AQD), and lens thickness were obtained. The repeatability of CASIA2 measurements was assessed. RESULTS: In patients with cataract, the CCT, AQD, lens thickness, and lens anterior curvature by CASIA2 showed high intraclass correlation coefficients (ICCs) of > 0.99. Conversely, measurements of the posterior part of the lens such as lens posterior curvature showed lower ICCs. The ICCs were higher in healthy young participants than in patients with cataract. The ICCs tended to be lower in patients with mild than dense cataract. There was no statistically significant difference in the CCT and AQD between the CASIA2 and CASIA SS-1000 or in the lens thickness measurements between the CASIA2 and AL-4000 and between the CASIA2 and EAS-1000. There was a significant linear correlation in the biometric measurements between the CASIA2 and the other instruments. CONCLUSION: We evaluated the biometric measurements of the anterior eye segment by the CASIA2. The CASIA2 yielded results comparable with those of the CASIA SS-1000, ultrasonography, and Scheimpflug camera. However, mild cataract decreased the repeatability of measurements of the posterior part of the lens.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Biometria/métodos , Catarata/diagnóstico , Cristalino/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
BMC Ophthalmol ; 20(1): 454, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33208137

RESUMO

BACKGROUND: To prospectively evaluate surgical results following implantation of rotationally asymmetric, plate-haptic, refractive segmented multifocal toric intraocular lenses (IOLs) with near addition of + 1.5 diopters (D) (Lentis Comfort LS-313 MF15T, Oculentis GmbH). METHODS: In 59 eyes of 41 patients, ocular examinations were conducted before and 1 day, 1 week, 1, 3, and 6 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were tested. A defocus curve was drawn, and the degree of disturbing photic phenomena were questioned. RESULTS: The IOL showed excellent rotational stability; the average absolute rotation was 1.66 ± 1.17 degrees from 1 day 1 to 6 months postoperatively, and 98.1 and 100% of eyes yielded rotation of less than 5 and 10 degrees, respectively. Postoperative distance and intermediate visual acuity were highly satisfactory; UDVA, CDVA, UIVA, and DCIVA were about 20/20, 20/16, 20/25, 20/25, respectively. Near visual acuity was suboptimal; UNVA and DCNVA were at approximately 20/60. The defocus curve analysis showed that 20/25 and 20/40 uncorrected visual acuity was attained at as close as 60 and 40 cm, respectively. Contrast sensitivity was within a normal range, and subjective photic phenomena were minimum. CONCLUSIONS: The refractive segmented, rotationally asymmetric multifocal toric IOLs with + 1.5 D near addition showed superb rotational stability and highly satisfactory distance and intermediate vision. Contrast sensitivity was high and incidence of photic symptoms was very low. TRIAL REGISTRATION: This study was registered at JAPIC Clinical Trials Information, ID: JapicCTI-183,877, https://www.clinicaltrials.jp/cti-user/trial/Search.jsp (February 5, 2018).


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Desenho de Prótese , Pseudofacia , Refração Ocular
11.
Retina ; 39(4): 779-785, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29252975

RESUMO

PURPOSE: To evaluate the clinical characteristics and visual outcomes of patients with traffic accident-related open globe injuries, and to examine preoperative factors influencing the visual prognosis after pars plana vitrectomy, as compared with common open globe injuries. METHODS: Patients with open globe injuries, who underwent pars plana vitrectomy, were identified. Patients' demographic and clinical data were entered into a computerized database for review and analysis; data included age, sex, initial visual acuity, duration between onset of injury and surgery, information about the type and cause of injury, wound location and length, presence of ocular complications, and final visual acuity. RESULTS: Of the 355 open globe injuries, 14 were sustained during a traffic-related accident; the average age was 50.4 years (range: 20-85) and most (78.6%) were men. Of these 14 patients, 9 (64.3%) presented with rupture and 5 (35.7%) with laceration. Injuries were caused while driving (6 eyes; 42.9%), riding a bicycle (5 eyes; 35.7%), involved in car accident while walking (2 eyes; 14.3%), and riding a motorbike (1 eye; 7.1%). Initial visual acuity was significantly related to final visual acuity (P = 0.003, R = 0.80). The final visual acuity in patients with traffic accident-related open globe injuries was significantly better than that of the total group (P = 0.01). CONCLUSION: Traffic accident-related open globe injuries had better visual outcomes than common open globe injuries. Visual outcomes in patients with traffic accident-related open globe injuries were related to the initial visual acuity. No eyes developed endophthalmitis in patients with traffic accident-related open globe injuries.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Ferimentos Oculares Penetrantes/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Condução de Veículo , Ciclismo/lesões , Ferimentos Oculares Penetrantes/fisiopatologia , Ferimentos Oculares Penetrantes/cirurgia , Feminino , Humanos , Japão/epidemiologia , Lacerações/epidemiologia , Lacerações/fisiopatologia , Lacerações/cirurgia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Ruptura/epidemiologia , Ruptura/fisiopatologia , Ruptura/cirurgia , Acuidade Visual/fisiologia , Vitrectomia , Adulto Jovem
12.
Ophthalmology ; 125(1): 31-35, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28827044

RESUMO

PURPOSE: To analyze the incidence and appropriate timing of repositioning surgery to correct misalignment of acrylic foldable toric intraocular lenses (IOLs). DESIGN: Retrospective, multicenter case series. PARTICIPANTS: Patients who had undergone phacoemulsification and implantation of toric IOL at 8 surgical sites. METHODS: Patient charts were reviewed to collect data on repositioning surgery of toric IOLs. MAIN OUTCOME MEASURES: Incidence, timing, and outcomes of repositioning surgery. RESULTS: Among 6431 eyes implanted with toric IOLs, 42 eyes (0.653%) of 42 patients underwent repositioning surgery at an average of 9.9±7.5 days (range, 0-30 days) after IOL implantation. The repositioning surgery significantly reduced misalignment from 32.9°±15.7° to 8.8°±9.7° (P < 0.001), which was measured at 7.6±5.0 weeks postoperatively. Refractive cylinder was significantly reduced from 2.4±1.1 diopters (D) to 1.1±0.8 D (P < 0.001). There was a significant negative correlation between the interval from cataract surgery to repositioning procedure and the degree of residual misalignment (r = -0.439, P < 0.001). The residual misalignment was 13.1°±13.5° when the repositioning surgery was performed within 6 days after cataract surgery, whereas the residual misalignment was 6.3°±5.9° when the IOL was repositioned 7 days or later (P < 0.001). In 2 eyes that were treated within 24 hours after cataract surgery, the IOL re-rotated significantly, and additional surgical intervention was required. CONCLUSIONS: Toric IOLs were repositioned in 0.653% of cases. A relationship was found between the timing of repositioning surgery and surgical outcome. These data suggest that repositioning surgery should be performed 1 week after IOL implantation.


Assuntos
Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos
13.
Exp Eye Res ; 177: 117-121, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30096324

RESUMO

The purpose of this study was to evaluate absorbable polyethylene glycol (PEG)-based synthetic hydrogel as a sealant for retinal breaks in rhegmatogenous retinal detachment (RD). A three-port, 25-gauge vitrectomy was performed on nine Dutch pigmented rabbit eyes. Subsequently, RD was induced by creating a retinal break. The retina was then reattached by fluid-air exchange. In six of nine eyes (RD-PEG group), PEG sealant was applied to completely cover the retinal breaks, and then photopolymerized with light; thereafter, intravitreous air was replaced with balanced salt solution (BSS). In the remaining three eyes (RD group), PEG sealant was not applied, but the intravitreous air was replaced with BSS. Ophthalmological examinations and intraocular pressure measurements were conducted preoperatively, and at 1 and 7 days, and 1, 3, and 6 months postoperatively. Histological examinations of the eyes were performed after 6 postoperative months. At surgery, retinal reattachment with PEG sealant was achieved in all eyes in the RD-PEG group. Fundoscopic and optical coherence tomographic examinations revealed that the retina remained attached in all the eyes of the RD-PEG group throughout the 6-month observation period. Histological examination revealed no signs of damage in the retinal layers at the edges of the retinal breaks that were in contact with the sealant. In the RD group, the retinas detached in all eyes within 7 days postoperatively. The PEG sealant closed the retinal breaks and maintained retinal reattachment. Intraocular tamponade was not necessary.


Assuntos
Hidrogéis/uso terapêutico , Polietilenoglicóis/uso terapêutico , Descolamento Retiniano/cirurgia , Perfurações Retinianas/cirurgia , Vitrectomia/métodos , Animais , Materiais Biocompatíveis/uso terapêutico , Modelos Animais de Doenças , Imuno-Histoquímica , Coelhos , Tomografia de Coerência Óptica
14.
Graefes Arch Clin Exp Ophthalmol ; 256(7): 1347-1352, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29546473

RESUMO

PURPOSE: To investigate the clinical characteristics and visual outcomes in patients with fall-related open globe injuries and to evaluate differences between fall-related and non-fall-related open globe injuries in Japan. METHODS: A retrospective review of patients with open globe injury who presented to Japan-Clinical Research of Study (J-CREST) hospitals between 2005 and 2015 was enrolled. Clinical information including age, sex, initial visual acuity, final visual acuity, type of injury, status of the crystalline lens, zone of injury, wound length, presence of retinal detachment, proliferative vitreoretinopathy, expulsive hemorrhage, and endophthalmitis was recorded. RESULTS: A total of 374 eyes were enrolled, of which 120 (32.1%) suffered from fall-related injury with average age of 73.7 ± 15.9 years (range, 11-101 years). A majority of patients were female (55.8%). Of 120 patients with fall-related injury, 109 (90.8%) presented with rupture and 11 (9.2%) with laceration. A multiple regression analysis revealed that final visual acuity was significantly associated with initial visual acuity (r = 0.99, P < 0.001). Compared to non-fall-related open globe injuries, fall-related open globe injuries were associated with elderly age, female sex, poorer initial and final visual acuity, rupture, absence of the lens, larger wound size, retinal detachment, expulsive hemorrhage, and absence of endophthalmitis (P < 0.01). CONCLUSIONS: Fall-related open globe injuries were more frequent in elderly female and accompanied by larger wound lengths and severer ocular complications. Visual outcomes in patients with fall-related open globe injuries were related to initial visual acuity.


Assuntos
Acidentes por Quedas/estatística & dados numéricos , Ferimentos Oculares Penetrantes/etiologia , Medição de Risco/métodos , Acuidade Visual , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Ruptura , Distribuição por Sexo , Índices de Gravidade do Trauma , Adulto Jovem
15.
Retina ; 38(4): 684-691, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28333885

RESUMO

PURPOSE: To investigate changes in metamorphopsia after rhegmatogenous retinal detachment surgery and to evaluate the relationship between metamorphopsia and retinal microstructures assessed with optical coherence tomography. METHODS: The study included 47 eyes of 47 patients undergoing retinal detachment surgery. We examined the severity of metamorphopsia using M-CHARTS, best-corrected visual acuity, and optical coherence tomography images. All data were recorded before and 3, 6, and 12 months after surgery, except for M-CHARTS which were recorded only postoperatively. RESULTS: Metamorphopsia scores at 3, 6, and 12 months postoperatively were 0.46 ± 0.51, 0.41 ± 0.44, and 0.28 ± 0.37, respectively, with significant improvement from 3 months to 12 months after surgery. Significant metamorphopsia (score ≥0.2) was present in 49% of patients at 12 months postoperatively. Multiple regression analysis revealed that metamorphopsia score at 12 months was significantly related to the status of macula and interdigitation zone. In patients with macula-off retinal detachment, improvement of metamorphopsia scores was associated with an increase in thickness of external limiting membrane-retinal pigment epithelium. CONCLUSION: After successful retinal detachment surgery, metamorphopsia gradually improved, but nearly half of the patients still exhibited metamorphopsia at 12 months postoperatively. Disruption of interdigitation zone and external limiting membrane-retinal pigment epithelium thickness was related to metamorphopsia.


Assuntos
Descolamento Retiniano/cirurgia , Transtornos da Visão/patologia , Vitrectomia , Adulto , Idoso , Membrana Basal/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Descolamento Retiniano/patologia , Epitélio Pigmentado da Retina/patologia , Tomografia de Coerência Óptica , Resultado do Tratamento , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia
16.
Retina ; 38(8): 1581-1587, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-28614133

RESUMO

PURPOSE: To evaluate the effects of intravitreal ranibizumab injection (IVR) on metamorphopsia in patients with branch retinal vein occlusion (BRVO) and to assess the relationship between retinal microstructure and metamorphopsia. METHODS: Subjects were 39 eyes of 39 patients with branch retinal vein occlusion. The severity of metamorphopsia was quantified using the M-CHARTS before and 1, 2, 3, 4, 5, and 6 months after treatment. Based on optical coherence tomography (OCT) images, we assessed central retinal thickness (CRT) and status of the external limiting membrane (ELM) and ellipsoid zone (EZ). The association between retinal microstructure and metamorphopsia was analyzed in 24 eyes with treatment-naïve branch retinal vein occlusion. RESULTS: Intravitreal ranibizumab injection treatment significantly improved best-corrected visual acuity (BCVA) and central retinal thickness (P < 0.0001, P < 0.0001, respectively), but metamorphopsia did not improve by treatment. Posttreatment metamorphopsia scores showed a significant correlation with duration of symptoms (P < 0.05) and pretreatment metamorphopsia scores (P < 0.01). Posttreatment metamorphopsia score was significantly worse in patients with disruption of external limiting membrane (P < 0.05). CONCLUSIONS: In patients with branch retinal vein occlusion, intravitreal ranibizumab injection treatment significantly improved best-corrected visual acuity and central retinal thickness, but not metamorphopsia. The severity of posttreatment metamorphopsia was significantly associated with duration of symptoms, degree of pretreatment metamorphopsia, and posttreatment integrity of external limiting membrane.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Ranibizumab/uso terapêutico , Oclusão da Veia Retiniana/tratamento farmacológico , Transtornos da Visão/tratamento farmacológico , Adulto , Idoso , Feminino , Humanos , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Retina/patologia , Oclusão da Veia Retiniana/patologia , Tomografia de Coerência Óptica , Transtornos da Visão/patologia
17.
BMC Ophthalmol ; 18(1): 166, 2018 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-29986671

RESUMO

BACKGROUND: The prospective observation study aimed to evaluate changes in corneal higher-order aberrations induced by advancement of pterygium using an anterior-segment optical coherence tomography (AS-OCT) and Zernike aberration analysis. METHODS: The corneal topography of 284 eyes with primary pterygia originating from the nasal region was measured using an AS-OCT (SS-1000, Tomey). With anterior corneal elevation data, Zernike polynomial coefficients were calculated in diameters of 1.0, 3.0, and 5.0 mm, and the coma, spherical, coma-like, spherical-like, and total higher-order aberrations were obtained. Pterygium size was also measured as a ratio of positions of the pterygium end with respect to the corneal diameter and categorized in eight classes: less than 15%, 15-20%, 20-25%, 25-30%, 30-35%, 35-40%, 40-45, and 45% or larger. Increases in the aberrations were analyzed with reference to those in eyes with pterygium size < 15%. RESULTS: The mean age of the participants was 69.3 years, and the pterygium size ranged from 2 to 57% (mean: 28.8%). The coma aberration significantly increased when the pterygium size was 45% or larger in 1.0 and 3.0 mm diameters and over 25-30% in 5.0 mm diameter. Similar increases were found in the pterygium sizes exceeding 45, 40, and 25%, respectively, in the coma-like, spherical-like, and total higher-order aberrations. On contrast, there was no increase in the spherical aberration. CONCLUSION: Increases in higher-order aberrations reflected the pterygium size, and significant aberrations were induced in 5.0 mm diameter when the end exceeded 25% of corneal diameter. The use of AS-OCT and Zernike analysis could enable objective grading of pterygium advancement based on changes in corneal optics.


Assuntos
Segmento Anterior do Olho/patologia , Pterígio/diagnóstico , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Córnea/patologia , Topografia da Córnea/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Acuidade Visual
18.
Ophthalmic Physiol Opt ; 38(3): 281-289, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29691927

RESUMO

PURPOSE: To compare rates of myopia progression and adverse events between orthokeratology (OK) and soft contact lens (SCL) wearers over a 10-year period in schoolchildren. METHODS: Medical records of consecutive patients (≤16 years of age at baseline) who started OK for myopia correction and continued the treatment for 10 years were retrospectively reviewed. For the control group, patients who started using soft contact lenses (SCLs) for myopia correction and continued to use them for 10 years were also reviewed. Clinical data, including sex, age, manifest refraction, visual acuity, prescription lens power, and adverse events during the 10-year period, were recorded. Estimated myopia progression was calculated as the sum of 'changes in prescription lens power during 10 years' and 'residual refractive errors at the 10-year visit,' and was compared between groups. We also compared the incidence of adverse events between groups over the 10-year study period. RESULTS: A total of 104 eyes of 53 patients who underwent OK treatment and 78 eyes of 39 patients who wore SCLs fulfilled the criteria. The estimated myopia progression over the 10-year period found in the OK and SCL groups were -1.26 ± 0.98 and -1.79 ± 1.24 days, respectively; this difference was statistically significant (p = 0.001). Additionally, lower myopia progression was found in the OK in comparison to the SCL group at all baseline ages (p = 0.003 to p = 0.049) except at 16 years old (p = 0.41). No significant difference was found in the number of adverse events found between the OK (119) and SCL (103) groups (p = 0.72). CONCLUSIONS: The results of this study supports the long-term efficacy and safety of OK lens wear in reducing myopia progression in schoolchildren.


Assuntos
Córnea/patologia , Previsões , Miopia/terapia , Procedimentos Ortoceratológicos/métodos , Refração Ocular/fisiologia , Acuidade Visual , Adolescente , Criança , Topografia da Córnea , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Miopia/diagnóstico , Miopia/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
19.
Ophthalmology ; 124(4): 519-523, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28110952

RESUMO

PURPOSE: To report the results of a clinical investigation after an outbreak of subacute-onset toxic anterior segment syndrome (TASS) after implantation of single-piece acrylic intraocular lenses (IOLs), which then were recalled voluntarily from the market. DESIGN: Retrospective, multicenter, observational case series. PARTICIPANTS: Cases reported to the manufacturer from January 2015 through March 2016 of unusual ocular inflammation after cataract surgery using AcrySof ReSTOR, ReSTOR toric, or AcrySof IQ toric SN6AT6-9 IOLs (Alcon Laboratories, Inc., Fort Worth, TX). METHODS: The independent investigation committee, not Alcon, directly requested the surgeons for data on 304 eyes from 184 facilities. RESULTS: Consent for data collection was obtained for 201 eyes from 130 facilities. By excluding cases with infectious endophthalmitis and inconclusive cases, the investigation committee identified 147 cases of subacute-onset TASS. AcrySof ReSTOR or ReSTOR toric IOLs and AcrySof IQ toric SN6AT6-9 IOLs were implanted in 94 eyes (63.9%) and 53 eyes (36.1%), respectively. The mean onset time was 13.1±16.4 days after surgery (range, 1-88 days), with 84 eyes (57.1%) demonstrating symptoms within 7 days after surgery. Typical clinical symptoms were mild to moderate exacerbation of inflammation in the anterior chamber after an uneventful clinical course for a few days after surgery. One hundred four eyes (70.7%) were treated with medication alone, and 43 eyes (29.3%) underwent surgery, including irrigation of the anterior chamber, vitrectomy, and removal of the IOL. The mean best-corrected visual acuity (BCVA) at the final visit (-0.012±0.175 logarithm of the minimum angle of resolution [logMAR]) was significantly better than the BCVA at the onset of TASS (0.158±0.351 logMAR) and did not differ from that before inflammation developed (-0.004±0.162 logMAR). Overall treatment outcomes were favorable. CONCLUSIONS: A large-scale outbreak of subacute-onset TASS developed after implantation of a specific model of IOL.


Assuntos
Resinas Acrílicas/efeitos adversos , Segmento Anterior do Olho/patologia , Surtos de Doenças , Endoftalmite/epidemiologia , Lentes Intraoculares/efeitos adversos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Endoftalmite/diagnóstico , Endoftalmite/tratamento farmacológico , Contaminação de Equipamentos , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Recall de Dispositivo Médico , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos , Facoemulsificação , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Acuidade Visual/fisiologia
20.
Graefes Arch Clin Exp Ophthalmol ; 255(12): 2437-2442, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28971252

RESUMO

PURPOSE: To quantitatively assess the biometry of the ciliary body in normal human eyes using ultrasound biomicroscopy. METHODS: We evaluated 85 eyes of 85 normal subjects (35 men and 50 women), whose age ranged from 11 to 86 years (mean ± SD, 56.8 ± 20.4 years). The eyes were assessed along the 3-, 6-, 9-, and 12-o'clock meridians relative to the center of the cornea. Clinical data were collected, including age, axial length, ciliary body length (CBL), ciliary body thickness (CBT), anterior chamber depth, iris root thickness, trabecular-iris angle, and scleral-ciliary process angle. Axial length was measured using A-scan ultrasonography. RESULTS: CBL and CBT tended to be larger in the superior than in the inferior quadrant, but the differences among the four quadrants were not statistically significant. The average CBL showed a significant positive correlation with the average CBT (r = 0.40, P < 0.001). Average CBL and CBT were significantly correlated with axial length (r = 0.33, P = 0.031; r = 0.46, P < 0.01 respectively). In addition, the average CBL was significantly correlated with anterior chamber depth (r = 0.23, P < 0.05), trabecular-iris angle (r = 0.29, P = 0.01), and scleral-ciliary process angle (r = 0.40, P < 0.001). CONCLUSIONS: Ultrasound biomicroscopic imaging demonstrated that the ciliary body is similar in size in all circumferences, and eyes with longer axial length have an elongated and thicker ciliary body. The values obtained in the present study may serve as standard clinical references.


Assuntos
Corpo Ciliar/diagnóstico por imagem , Glaucoma/diagnóstico , Microscopia Acústica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa