Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 92(1): 15-27, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38501903

RESUMO

Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real-time, motion-robust, and volumetric MR thermometry. However, current technologies have inherent trade-offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting-edge MRI techniques for motion-robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion-robust MR thermometry strategies and inspire the development of motion-robust volumetric MR thermometry for practical use in clinics.


Assuntos
Imageamento por Ressonância Magnética , Movimento (Física) , Humanos , Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Termografia/métodos , Algoritmos , Hipertermia Induzida , Artefatos
2.
Eur Radiol ; 34(2): 1137-1145, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37615768

RESUMO

OBJECTIVE: To assess the safety and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for the treatment extra-abdominal desmoids. METHODS: A total of 105 patients with desmoid fibromatosis (79 females, 26 males; 35 ± 14 years) were treated with MRgFUS between 2011 and 2021 in three centers. Total and viable tumors were evaluated per patient at last follow-up after treatment. Response and progression-free survival (PFS) were assessed with (modified) response evaluation criteria in solid tumors (RECIST v.1.1 and mRECIST). Change in Numerical Rating Scale (NRS) pain and 36-item Short Form Health Survey (SF-36) scores were compared. Treatment-related adverse events were recorded. RESULTS: The median initial tumor volume was 114 mL (IQR 314 mL). After MRgFUS, median total and viable tumor volume decreased to 51 mL (95% CI: 30-71 mL, n = 101, p < 0.0001) and 29 mL (95% CI: 17-57 mL, n = 88, p < 0.0001), respectively, at last follow-up (median: 15 months, 95% CI: 11-20 months). Based on total tumor measurements (RECIST), 86% (95% CI: 75-93%) had at least stable disease or better at last follow-up, but 50% (95% CI: 38-62%) of remaining viable nodules (mRECIST) progressed within the tumor. Median PFS was reached at 17 and 13 months for total and viable tumors, respectively. NRS decreased from 6 (IQR 3) to 3 (IQR 4) (p < 0.001). SF-36 scores improved (physical health (41 (IQR 15) to 46 (IQR 12); p = 0.05, and mental health (49 (IQR 17) to 53 (IQR 9); p = 0.02)). Complications occurred in 36%, most commonly 1st/2nd degree skin burns. CONCLUSION: MRgFUS reduced tumor volume, reduced pain, and improved quality of life in this series of 105 patients with extra-abdominal desmoid fibromatosis. CLINICAL RELEVANCE STATEMENT: Imaging-guided ablation is being increasingly used as an alternative to surgery, radiation, and medical therapy for the treatment of desmoid fibromatosis. MR-guided high-intensity focused ultrasound is an incisionless ablation technique that can be used to reduce tumor burden effectively and safely. KEY POINTS: • Desmoid fibromatosis was treated with MR-guided high-intensity focused ultrasound in 105 patients. • MR-guided focused ultrasound ablation reduced tumor volume and pain and improved quality of life. • MR-guided focused ultrasound is a treatment option for patients with extra-abdominal desmoid tumors.


Assuntos
Fibromatose Agressiva , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Masculino , Feminino , Fibromatose Agressiva/diagnóstico por imagem , Fibromatose Agressiva/terapia , Fibromatose Agressiva/patologia , Estudos Retrospectivos , Qualidade de Vida , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Dor , Resultado do Tratamento
3.
Int J Hyperthermia ; 41(1): 2349080, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38705588

RESUMO

OBJECTIVES: To investigate image-guided volumetric hyperthermia strategies using the ExAblate Body MR-guided focused ultrasound ablation system, involving mechanical transducer movement and sector-vortex beamforming. MATERIALS AND METHODS: Acoustic and thermal simulations were performed to investigate volumetric hyperthermia using mechanical transducer movement combined with sector-vortex beamforming, specifically for the ExAblate Body transducer. The system control in the ExAblate Body system was modified to achieve fast transducer movement and MR thermometry-based hyperthermia control, mechanical transducer movements and electronic sector-vortex beamforming were combined to optimize hyperthermia delivery. The experimental validation was performed using a tissue-mimicking phantom. RESULTS: The developed simulation framework allowed for a parametric study with varying numbers of heating spots, sonication durations, and transducer movement times to evaluate the hyperthermia characteristics for mechanical transducer movement and sector-vortex beamforming. Hyperthermic patterns involving 2-4 sequential focal spots were analyzed. To demonstrate the feasibility of volumetric hyperthermia in the system, a tissue-mimicking phantom was sonicated with two distinct spots through mechanical transducer movement and sector-vortex beamforming. During hyperthermia, the average values of Tmax, T10, Tavg, T90, and Tmin over 200 s were measured within a circular ROI with a diameter of 10 pixels. These values were found to be 8.6, 7.9, 6.6, 5.2, and 4.5 °C, respectively, compared to the baseline temperature. CONCLUSIONS: This study demonstrated the volumetric hyperthermia capabilities of the ExAblate Body system. The simulation framework developed in this study allowed for the evaluation of hyperthermia characteristics that could be implemented with the ExAblate MRgFUS system.


Assuntos
Hipertermia Induzida , Imageamento por Ressonância Magnética , Humanos , Hipertermia Induzida/métodos , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imagens de Fantasmas
4.
Int J Hyperthermia ; 40(1): 2151649, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36535967

RESUMO

PURPOSE: To develop an effective and practical reconstruction pipeline to achieve motion-robust, multi-slice, real-time MR thermometry for monitoring thermal therapy in abdominal organs. METHODS: The application includes a fast spiral magnetic resonance imaging (MRI) pulse sequence and a real-time reconstruction pipeline based on multi-baseline proton resonance frequency shift (PRFS) method with visualization of temperature imaging. The pipeline supports multi-slice acquisition with minimal reconstruction lag. Simulations with a virtual motion phantom were performed to investigate the influence of the number of baselines and respiratory rate on the accuracy of temperature measurement. Phantom experiments with ultrasound heating were performed using a custom-made motion phantom to evaluate the performance of the pipeline. Lastly, experiments in healthy volunteers (N = 2) without heating were performed to evaluate the accuracy and stability of MR thermometry in abdominal organs (liver and kidney). RESULTS: The multi-baseline approach with greater than 25 baselines resulted in minimal temperature errors in the simulation. Phantom experiments demonstrated a 713 ms update time for 3-slice acquisitions. Temperature maps with 30 baselines showed clear temperature distributions caused by ultrasound heating in the respiratory phantom. Finally, the pipeline was evaluated with physiologic motions in healthy volunteers without heating, which demonstrated the accuracy (root mean square error [RMSE]) of 1.23 ± 0.18 °C (liver) and 1.21 ± 0.17 °C (kidney) and precision of 1.13 ± 0.11 °C (liver) and 1.16 ± 0.15 °C (kidney) using 32 baselines. CONCLUSIONS: The proposed real-time acquisition and reconstruction pipeline allows motion-robust, multi-slice, real-time temperature monitoring within the abdomen during free breathing.


Assuntos
Termometria , Humanos , Termometria/métodos , Temperatura , Imageamento por Ressonância Magnética/métodos , Temperatura Corporal , Fígado/cirurgia , Imagens de Fantasmas
5.
Pain Med ; 24(Suppl 1): S81-S94, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-36069660

RESUMO

Management of patients suffering from low back pain (LBP) is challenging and requires development of diagnostic techniques to identify specific patient subgroups and phenotypes in order to customize treatment and predict clinical outcome. The Back Pain Consortium (BACPAC) Research Program Spine Imaging Working Group has developed standard operating procedures (SOPs) for spinal imaging protocols to be used in all BACPAC studies. These SOPs include procedures to conduct spinal imaging assessments with guidelines for standardizing the collection, reading/grading (using structured reporting with semi-quantitative evaluation using ordinal rating scales), and storage of images. This article presents the approach to image acquisition and evaluation recommended by the BACPAC Spine Imaging Working Group. While the approach is specific to BACPAC studies, it is general enough to be applied at other centers performing magnetic resonance imaging (MRI) acquisitions in patients with LBP. The herein presented SOPs are meant to improve understanding of pain mechanisms and facilitate patient phenotyping by codifying MRI-based methods that provide standardized, non-invasive assessments of spinal pathologies. Finally, these recommended procedures may facilitate the integration of better harmonized MRI data of the lumbar spine across studies and sites within and outside of BACPAC studies.


Assuntos
Degeneração do Disco Intervertebral , Dor Lombar , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Região Lombossacral , Dor Lombar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
6.
Int J Hyperthermia ; 38(1): 1590-1600, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34749579

RESUMO

PURPOSE: The ExAblate body MRgFUS system requires advanced beamforming strategies for volumetric hyperthermia. This study aims to develop and evaluate electronic beam steering, multi-focal patterns, and sector vortex beamforming approaches in conjunction with partial array activation using an acoustic and biothermal simulation framework along with phantom experiments. METHODS: The simulation framework was developed to calculate the 3D acoustic intensity and temperature distribution resulting from various beamforming and scanning strategies. A treatment cell electronically sweeping a single focus was implemented and evaluated in phantom experiments. The acoustic and thermal focal size of vortex beam propagation was quantified according to the vortex modes, number of active array elements, and focal depth. RESULTS: Turning off a percentage of the outer array to increase the f-number increased the focal size with a decrease in focal gain. 60% active elements allowed generating a sonication cell with an off-axis of 10 mm. The vortex mode number 4 with 60% active elements resulted in a larger heating volume than using the full array. Volumetric hyperthermia in the phantom was evaluated with the vortex mode 4 and respectively performed with 100% and 80% active elements. MR thermometry demonstrated that the volumes were found to be 18.8 and 29.7 cm3, respectively, with 80% array activation producing 1.58 times larger volume than the full array. CONCLUSIONS: This study demonstrated that both electronic beam steering and sector vortex beamforming approaches in conjunction with partial array activation could generate large volume heating for HT delivery using the ExAblate body array.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Sonicação
7.
Int J Hyperthermia ; 38(1): 130-135, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33541151

RESUMO

OBJECTIVE: To develop a thermochromic tissue-mimicking phantom (TTMP) with an embedded 3D-printed bone mimic of the lumbar spine to evaluate MRgFUS ablation of the facet joint and medial branch nerve. MATERIALS AND METHODS: Multiple 3D-printed materials were selected and characterized by measurements of speed of sound and linear acoustic attenuation coefficient using a through-transmission technique. A 3D model of the lumbar spine was segmented from a de-identified CT scan, and 3D printed. The 3D-printed spine was embedded within a TTMP with thermochromic ink color change setpoint at 60 °C. Multiple high energy sonications were targeted to the facet joints and medial branch nerve anatomical location using an ExAblate MRgFUS system connected to a 3T MR scanner. The phantom was dissected to assess sonication targets and the surrounding structures for color change as compared to the expected region of ablation on MR-thermometry. RESULTS: The measured sound attenuation coefficient and speed of sound of gypsum was 240 Np/m-MHz and 2471 m/s, which is the closest to published values for cortical bone. Following sonication, dissection of the TTMP revealed good concordance between the regions of color change within the phantom and expected areas of ablation on MR-thermometry. No heat deposition was observed in critical areas, including the spinal canal and nerve roots from either color change or MRI. CONCLUSION: Ablated regions in the TTMP correlated well with expected ablations based on MR-thermometry. These findings demonstrate the utility of an anatomic spine phantom in evaluating MRgFUS sonication for facet joint and medial branch nerve ablations.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Articulação Zigapofisária , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ultrassonografia
8.
Radiology ; 295(1): 136-145, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32013791

RESUMO

Background A multitask deep learning model might be useful in large epidemiologic studies wherein detailed structural assessment of osteoarthritis still relies on expert radiologists' readings. The potential of such a model in clinical routine should be investigated. Purpose To develop a multitask deep learning model for grading radiographic hip osteoarthritis features on radiographs and compare its performance to that of attending-level radiologists. Materials and Methods This retrospective study analyzed hip joints seen on weight-bearing anterior-posterior pelvic radiographs from participants in the Osteoarthritis Initiative (OAI). Participants were recruited from February 2004 to May 2006 for baseline measurements, and follow-up was performed 48 months later. Femoral osteophytes (FOs), acetabular osteophytes (AOs), and joint-space narrowing (JSN) were graded as absent, mild, moderate, or severe according to the Osteoarthritis Research Society International atlas. Subchondral sclerosis and subchondral cysts were graded as present or absent. The participants were split at 80% (n = 3494), 10% (n = 437), and 10% (n = 437) by using split-sample validation into training, validation, and testing sets, respectively. The multitask neural network was based on DenseNet-161, a shared convolutional features extractor trained with multitask loss function. Model performance was evaluated in the internal test set from the OAI and in an external test set by using temporal and geographic validation consisting of routine clinical radiographs. Results A total of 4368 participants (mean age, 61.0 years ± 9.2 [standard deviation]; 2538 women) were evaluated (15 364 hip joints on 7738 weight-bearing anterior-posterior pelvic radiographs). The accuracy of the model for assessing these five features was 86.7% (1333 of 1538) for FOs, 69.9% (1075 of 1538) for AOs, 81.7% (1257 of 1538) for JSN, 95.8% (1473 of 1538) for subchondral sclerosis, and 97.6% (1501 of 1538) for subchondral cysts in the internal test set, and 82.7% (86 of 104) for FOS, 65.4% (68 of 104) for AOs, 80.8% (84 of 104) for JSN, 88.5% (92 of 104) for subchondral sclerosis, and 91.3% (95 of 104) for subchondral cysts in the external test set. Conclusion A multitask deep learning model is a feasible approach to reliably assess radiographic features of hip osteoarthritis. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Aprendizado Profundo , Modelos Teóricos , Osteoartrite do Quadril/diagnóstico por imagem , Radiografia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença
9.
J Magn Reson Imaging ; 52(4): 1163-1172, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32293775

RESUMO

BACKGROUND: Accurate interpretation of hip MRI is time-intensive and difficult, prone to inter- and intrareviewer variability, and lacks a universally accepted grading scale to evaluate morphological abnormalities. PURPOSE: To 1) develop and evaluate a deep-learning-based model for binary classification of hip osteoarthritis (OA) morphological abnormalities on MR images, and 2) develop an artificial intelligence (AI)-based assist tool to find if using the model predictions improves interreader agreement in hip grading. STUDY TYPE: Retrospective study aimed to evaluate a technical development. POPULATION: A total of 764 MRI volumes (364 patients) obtained from two studies (242 patients from LASEM [FORCe] and 122 patients from UCSF), split into a 65-25-10% train, validation, test set for network training. FIELD STRENGTH/SEQUENCE: 3T MRI, 2D T2 FSE, PD SPAIR. ASSESSMENT: Automatic binary classification of cartilage lesions, bone marrow edema-like lesions, and subchondral cyst-like lesions using the MRNet, interreader agreement before and after using network predictions. STATISTICAL TESTS: Receiver operating characteristic (ROC) curve, area under curve (AUC), specificity and sensitivity, and balanced accuracy. RESULTS: For cartilage lesions, bone marrow edema-like lesions and subchondral cyst-like lesions the AUCs were: 0.80 (95% confidence interval [CI] 0.65, 0.95), 0.84 (95% CI 0.67, 1.00), and 0.77 (95% CI 0.66, 0.85), respectively. The sensitivity and specificity of the radiologist for binary classification were: 0.79 (95% CI 0.65, 0.93) and 0.80 (95% CI 0.59, 1.02), 0.40 (95% CI -0.02, 0.83) and 0.72 (95% CI 0.59, 0.86), 0.75 (95% CI 0.45, 1.05) and 0.88 (95% CI 0.77, 0.98). The interreader balanced accuracy increased from 53%, 71% and 56% to 60%, 73% and 68% after using the network predictions and saliency maps. DATA CONCLUSION: We have shown that a deep-learning approach achieved high performance in clinical classification tasks on hip MR images, and that using the predictions from the deep-learning model improved the interreader agreement in all pathologies. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 1 J. Magn. Reson. Imaging 2020;52:1163-1172.


Assuntos
Inteligência Artificial , Interpretação de Imagem Assistida por Computador , Computadores , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Int J Hyperthermia ; 36(1): 473-476, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30922118

RESUMO

PURPOSE: Desmoid tumors are benign, locally aggressive soft tissue tumors derived from fibroblasts. Magnetic resonance-guided focused ultrasound (MRgFUS) is a safe and effective treatment for desmoid tumors. The purpose of this study was to retrospectively review the MRgFUS treatments of desmoid tumors at our institution to determine which technical treatment parameters contributed most significantly to the accumulation of thermal dose. MATERIALS AND METHODS: The study protocol was approved by the local IRB. We retrospectively reviewed data from MRgFUS treatments performed in histologically-confirmed desmoid tumors, over a period of 18 months. Sonication parameter means were compared with ANOVA. Mixed effects and linear regression models were used to evaluate the relative contribution of different parameters to thermal dose volume. RESULTS: Nine-hundred thirty-six sonications were reviewed in 13 treatments. Accumulated dose per sonication was greatest for elongated sonications (0.96 cc ± 0.90) compared to short (0.88 ± 0.93 cc) and nominal (0.55 ± 0.70 cc) sonications, p < .001. 65.2% of short sonications resulted in high percentage ablations, compared to 46.0% of nominal and 35.1% of elongated sonications. Standardized beta coefficients (anticipated increased volume in cc per unit) for power, duration, energy and average temperature were 0.006, 0.057, 0.00035 and 0.03, p < .001. Regarding dose efficacy, dose area contributed the greatest to this variability - 50.7% (45.5-54.8%), followed by distance - 16.6% (12.9-20.0%). CONCLUSIONS: A variety of sonication parameters significantly contributed to thermal ablation volume following MRgFUS of desmoid tumors, in reproducible patterns. This work can serve as the basis for future models working toward improved planning for MRgFUS treatments.


Assuntos
Fibromatose Agressiva/diagnóstico por imagem , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias de Tecidos Moles/diagnóstico por imagem , Humanos , Estudos Retrospectivos
11.
Int J Hyperthermia ; 36(1): 1272-1277, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31822140

RESUMO

Objective: The objective of this study was to develop an alternative method of non-contrast monitoring of tissue ablation during focused ultrasound treatment. Desmoid tumors are benign but locally aggressive soft tissue tumors that arise from fibroblast cells. Magnetic resonance-guided focused ultrasound (MRgFUS) has emerged as an alternative to conventional therapies, showing promising results in reduction of tumor volume without significant side effects. The gold-standard assessment of the reduction of viable tumor volume post-treatment is non-perfused volume (NPV) and evaluation of NPV is typically performed with post-treatment gadolinium enhanced MR imaging. However, as gadolinium cannot be repeatedly administered during treatments, there is a need for alternative non-contrast monitoring of the tissue to prevent over and under treatment. Methods: Double-echo and multi-echo images were acquired before, during and after the MRgFUS treatment. T2 maps were generated with an exponential fit and T2 maps were compared to post-treatment post-contrast images.Results: In all five MRgFUS treatment sessions, T2 mapping showed excellent qualitative agreement with the post-contrast NPV.Conclusions: T2 mapping may be used to visualize the extent of ablation with focused ultrasound and can be used as a predictor of NPV prior to the administration of contrast during the post-treatment assessment.


Assuntos
Mapeamento Encefálico/métodos , Fibromatose Agressiva/diagnóstico por imagem , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Fibromatose Agressiva/patologia , Humanos , Resultado do Tratamento
12.
J Magn Reson Imaging ; 46(5): 1418-1422, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28225581

RESUMO

PURPOSE: To evaluate the effect of differences in sonication duration and power on the size of postcontrast ablation zone following magnetic resonance-guided focused ultrasound (MRgFUS) of bone in a swine femoral bone model. MATERIALS AND METHODS: Experimental procedures received approval from the Institutional Committee on Animal Research. MRgFUS was used to create two thermal lesions in the left femur of six pigs. Each target was subjected to six sonications. 400J of energy was used for each sonication. However, the distal target received the standard sonication duration of 20 seconds (20W), while the proximal target received a longer sonication duration of 40 seconds (10W). MRgFUS lesions were imaged with fat-saturated spoiled gradient echo sequence at 3.0T MRI 10 minutes following the administration of contrast. Maximum three-plane dimensions of the hypoenhanced ablation area were measured. RESULTS: Postcontrast MR images demonstrated ovoid regions of hypoenhancement at each target. The average depth of ablation was significantly greater for the shorter high-power sonications (7.3 mm), compared to the longer lower-power sonications (4.5 mm), P = 0.026. The craniocaudal dimension was also greater for the shorter ablations 26.7 mm compared to the longer sonications 21.0 mm, P = 0.006. CONCLUSION: Contrary to anecdotal clinical experience, this preclinical model suggests that during MRgFUS of bone, standard duration, higher-power sonications resulted in deeper ablation volumes compared to long duration, lower-power sonications. These results suggest that to achieve deeper ablations, if longer sonications are used, then the power should be relatively maintained, for a net energy increase. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:1418-1422.


Assuntos
Osso e Ossos/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Ablação por Ultrassom Focalizado de Alta Intensidade , Imageamento por Ressonância Magnética , Sonicação , Acústica , Animais , Meios de Contraste , Feminino , Cirurgia Assistida por Computador , Suínos , Temperatura , Ultrassonografia
13.
Magn Reson Med ; 74(6): 1548-55, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26390357

RESUMO

PURPOSE: To demonstrate the feasibility of using ultrashort echo-time MRI to quantify T1 changes in cortical bone due to heating. METHODS: Variable flip-angle T1 mapping combined with 3D ultrashort echo-time imaging was used to measure T1 in cortical bone. A calibration experiment was performed to detect T1 changes with temperature in ex vivo cortical bone samples from a bovine femur. Ultrasound heating experiments were performed using an interstitial applicator in ex vivo bovine femur specimens, and heat-induced T1 changes were quantified. RESULTS: The calibration experiment demonstrated that T1 increases with temperature in cortical bone. We observed a linear relationship between temperature and T1 with a linear coefficient between 0.67 and 0.84 ms/°C over a range of 25-70°C. The ultrasound heating experiments showed increased T1 changes in the heated regions, and the relationship between the temperature changes and T1 changes was similar to that of the calibration. CONCLUSION: We demonstrated a temperature dependence of T1 in ex vivo cortical bone using a variable flip-angle ultrashort echo-time T1 mapping method.


Assuntos
Temperatura Corporal/fisiologia , Fêmur/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Animais , Temperatura Corporal/efeitos da radiação , Bovinos , Estudos de Viabilidade , Fêmur/efeitos da radiação , Calefação/métodos , Ondas de Choque de Alta Energia , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Magn Reson Imaging ; 41(5): 1332-41, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24935758

RESUMO

BACKGROUND: The purpose of this study was to evaluate the feasibility of using a short echo time, three-dimensional H-1 magnetic resonance spectroscopic imaging (MRSI) sequence at 7 Tesla (T) to assess the metabolic signature of lesions for patients with glioma. METHODS: Twenty-nine patients with glioma were studied. MRSI data were obtained using CHESS water suppression, spectrally selective adiabatic inversion-recovery pulses and automatically prescribed outer-volume-suppression for lipid suppression, and spin echo slice selection (echo time = 30 ms). An interleaved flyback echo-planar trajectory was applied to shorten the total acquisition time (∼10 min). Relative metabolite ratios were estimated in tumor and in normal-appearing white and gray matter (NAWM, GM). RESULTS: Levels of glutamine, myo-inositol, glycine, and glutathione relative to total creatine (tCr) were significantly increased in the T2 lesions for all tumor grades compared with those in the NAWM (P < 0.05), while N-acetyl aspartate to tCr were significantly decreased (P < 0.05). In grade 2 gliomas, level of total choline-containing-compounds to tCr was significantly increased (P = 0.0137), while glutamate to tCr was significantly reduced (P = 0.0012). CONCLUSION: The improved sensitivity of MRSI and the increased number of metabolites that can be evaluated using 7T MR scanners is of interest for evaluating patients with glioma. This study has successfully demonstrated the application of a short-echo spin-echo MRSI sequence to detect characteristic differences in regions of tumor versus normal appearing brain.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/metabolismo , Glioma/metabolismo , Imageamento Tridimensional/métodos , Imagem Molecular/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adulto , Idoso , Imagem Ecoplanar/métodos , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
15.
Magn Reson Imaging ; 110: 29-34, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38574982

RESUMO

PURPOSE: High quality scan prescription that optimally covers the area of interest with scan planes aligned to relevant anatomical structures is crucial for error-free radiologic interpretation. The goal of this project was to develop a machine learning pipeline for oblique scan prescription that could be trained on localizer images and metadata from previously acquired MR exams. METHODS: A novel Multislice Rotational Region-based Convolutional Neural Network (MS-R2CNN) architecture was developed. Based on this architecture, models for automated prescription sagittal lumbar spine acquisitions from axial, sagittal, and coronal localizer slices were trained. The automated prescription pipeline was integrated with the scanner console software and evaluated in experiments with healthy volunteers (N = 3) and patients with lower-back pain (N = 20). RESULTS: Experiments in healthy volunteers demonstrated high accuracy of automated prescription in all subjects. There was good agreement between alignment and coverage of manual and automated prescriptions, as well as consistent views of the lumbar spine at different positions of the subjects within the scanner bore. In patients with lower-back pain, the generated prescription was applied in 18 cases (90% of the total number). None of the cases required major adjustment, while in 11 cases (55%) there were minor manual adjustments to the generated prescription. CONCLUSIONS: This study demonstrates the ability of oriented object detection-based models to be trained to prescribe oblique lumbar spine MRI acquisitions without the need of manual annotation or feature engineering and the feasibility of using machine learning-based pipelines on the scanner for automated prescription of MRI acquisitions.


Assuntos
Processamento de Imagem Assistida por Computador , Dor Lombar , Vértebras Lombares , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Vértebras Lombares/diagnóstico por imagem , Dor Lombar/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Masculino , Feminino , Adulto , Voluntários Saudáveis , Redes Neurais de Computação , Software , Pessoa de Meia-Idade
16.
J Vis Exp ; (211)2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39345114

RESUMO

The brain has a highly selective semipermeable blood barrier, termed the blood-brain barrier (BBB), which prevents the delivery of therapeutic macromolecular agents to the brain. The integration of MR-guided low-intensity pulsed focused ultrasound (FUS) with microbubble pre-injection is a promising technique for non-invasive and non-toxic BBB modulation. MRI can offer superior soft-tissue contrast and various quantitative assessments, such as vascular permeability, perfusion, and the spatial-temporal distribution of MRI contrast agents. Notably, contrast-enhanced MRI techniques with gadolinium-based MR contrast agents have been shown to be the gold standard for detecting BBB openings. This study outlines a comprehensive methodology involving MRI protocols and animal procedures for monitoring BBB opening in a rat model. The rat model provides the added benefit of jugular vein catheter utilization, which facilitates rapid medication administration. A stereotactic-guided preclinical FUS transducer facilitates the refinement and streamlining of animal procedures and MRI protocols. The resulting methods are characterized by reproducibility and simplicity, eliminating the need for specialized surgical expertise. This research endeavors to contribute to the optimization of preclinical procedures with rat models and encourage further investigation into the modulation of the BBB to enhance therapeutic interventions in neurological disorders.


Assuntos
Barreira Hematoencefálica , Imageamento por Ressonância Magnética , Animais , Barreira Hematoencefálica/diagnóstico por imagem , Ratos , Imageamento por Ressonância Magnética/métodos , Microbolhas , Meios de Contraste/química , Ratos Sprague-Dawley , Ultrassonografia/métodos , Masculino
17.
Nat Commun ; 15(1): 1123, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321028

RESUMO

Shape-memory materials hold great potential to impart medical devices with functionalities useful during implantation, locomotion, drug delivery, and removal. However, their clinical translation is limited by a lack of non-invasive and precise methods to trigger and control the shape recovery, especially for devices implanted in deep tissues. In this study, the application of image-guided high-intensity focused ultrasound (HIFU) heating is tested. Magnetic resonance-guided HIFU triggered shape-recovery of a device made of polyurethane urea while monitoring its temperature by magnetic resonance thermometry. Deformation of the polyurethane urea in a live canine bladder (5 cm deep) is achieved with 8 seconds of ultrasound-guided HIFU with millimeter resolution energy focus. Tissue sections show no hyperthermic tissue injury. A conceptual application in ureteral stent shape-recovery reduces removal resistance. In conclusion, image-guided HIFU demonstrates deep energy penetration, safety and speed.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Poliuretanos , Animais , Cães , Calefação , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ureia
18.
Magn Reson Med ; 69(4): 920-30, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22692829

RESUMO

Two major difficulties encountered in implementing Magnetic Resonance Spectroscopic Imaging (MRSI) in a clinical setting are limited coverage and difficulty in prescription. The goal of this project was to automate completely the process of 3D PRESS MRSI prescription, including placement of the selection box, saturation bands and shim volume, while maximizing the coverage of the brain. The automated prescription technique included acquisition of an anatomical MRI image, optimization of the oblique selection box parameters, optimization of the placement of outer-volume suppression saturation bands, and loading of the calculated parameters into a customized 3D MRSI pulse sequence. To validate the technique and compare its performance with existing protocols, 3D MRSI data were acquired from six exams from three healthy volunteers. To assess the performance of the automated 3D MRSI prescription for patients with brain tumors, the data were collected from 16 exams from 8 subjects with gliomas. This technique demonstrated robust coverage of the tumor, high consistency of prescription and very good data quality within the T2 lesion.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias Encefálicas/metabolismo , Glioma/metabolismo , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Molecular/métodos , Algoritmos , Encéfalo/metabolismo , Encéfalo/patologia , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patologia , Glioma/diagnóstico , Glioma/patologia , Humanos , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Quant Imaging Med Surg ; 13(12): 7987-7995, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106288

RESUMO

Background: T2-weighted Single Shot Fast Spin Echo (SSFSE) scans at 3 Tesla (3T) are increasingly used to image fetal pathology due to their excellent tissue contrast resolution and signal-to-noise ratio (SNR). Temperature changes that may occur in response to radio frequency (RF) pulses used for these sequences at 3T have not been studied in human fetal brains. To evaluate the safety of T2-weighted SSFSE for fetal brains at 3T, magnetic resonance (MR) thermometry was used to measure relative temperature changes in a typical clinical fetal brain MR exam. Methods: Relative temperature was estimated using sets of gradient recalled echo (GRE) images acquired before and after T2-weighted SSFSE images which lasted 27.47±8.19 minutes. Thirty-one fetuses with cardiac abnormalities, and 20 healthy controls were included in this study. Fetal brain temperature was estimated by proton resonance frequency (PRF) thermometry and compared to the estimated temperature in the gluteal muscle of the mother. Seven scans with excessive motion were excluded. Local outlier factor (LOF) was performed to remove 12 additional scans with spurious phase measurements due to motion degradation and potential field drift. Linear regression was performed to determine if temperature changes are dependent on the rate of energy deposition during the scan. Results: For the 32 participants used in the analysis, 17 with cardiac abnormalities and 15 healthy controls, the average relative fetal temperate change was 0.19±0.73 ℃ higher than the mother, with no correlation between relative temperature change and the rate of images acquired during the scans (regression coefficient =-0.05, R-squared =0.05, P=0.22, F-statistic =1.60). The difference in the relative temperature changes between the fetal brain and mother's gluteal tissue in the healthy controls was on average 0.08 ℃ lower and found not to be statistically different (P=0.76) to the group with cardiac abnormalities. Conclusions: Our results indicate that the estimated relative temperature changes of the fetal brain compared to the mother's gluteal tissue from RF pulses during the course of the T2-weighted SSFSE fetal MR exam are minimal. The differences in acquired phase between these regions through the exam were found not to be statistically different. These findings support that fetal brain imaging at 3T is within FDA limits and safe.

20.
AJNR Am J Neuroradiol ; 45(1): 1-8, 2023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38123912

RESUMO

Interest in transcranial MR imaging-guided focused ultrasound procedures has recently grown. These incisionless procedures enable precise focal ablation of brain tissue using real-time monitoring by MR thermometry. This article will provide an updated review on clinically applicable technical underpinnings and considerations of proton resonance frequency MR thermometry, the most common clinically used MR thermometry sequence.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Humanos , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ultrassonografia , Termometria/métodos , Prótons
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa