Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Pediatr Otorhinolaryngol ; 179: 111938, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38579403

RESUMO

INTRODUCTION: Endoscopic ossicular chain reconstruction (OCR) in adults has demonstrated equivalent outcomes to the traditional microscopic approach. Less data exist on endoscopic OCR outcomes in children, who have unique considerations including a smaller transcanal corridor and variable pathology. The purpose of this study was to investigate surgical and audiometric outcomes in children undergoing fully endoscopic and endoscopic-assisted OCR in both the short and long-term. METHODS: Retrospective review of all children (<17 years) who underwent endoscopic OCR at one tertiary care center between 2017 and 2021. Children undergoing primary and revision endoscopic OCR with either partial (PORP) and total ossicular reconstruction prostheses (TORP) were included. Children undergoing surgery for juvenile otosclerosis or congenital stapes fixation, or any child receiving a stapes prosthesis were excluded. Primary outcome measures were post-operative change in 4 frequency (500 Hz, 1, 2, 4 KHz) air conduction pure tone average (AC PTA) and change in air-bone gap (ABG). Secondary measures included need for readmission and/or revision surgery, complication rate, and surgery duration. RESULTS: Seventeen patients met inclusion criteria. Average age was 11.3 years (range, 5-17 years); 14 were male. A variety of fixed length, titanium total and partial prostheses were used. The most common prosthesis length was 2 mm (range 2-5 mm), and there were no intra- or perioperative complications. Mean long-term follow-up was 2.6 years. Most common pathology was congenital cholesteatoma (11/17, 64%), followed by chronic otitis media with tympanic membrane perforation (5/17, 29.4%), and extruded prosthesis (1/17, 5.9%). Intraoperatively, the most common finding was incus erosion (10/17, 58.8%), followed by malleus erosion (6/17, 35.3%), stapes erosion (4/17, 23.5%), and stapes absence (4/17, 23.5%). Eight children (47%) were reconstructed with PORPs, and 9 children (52.9%) were reconstructed with TORPs. Average ABG improved from 36.8 dB preoperatively to 19.9 dB postoperatively in the short-term and remained stable at 19.5 dB in the long-term. Average short-term ABG improvement was 4.2 dB for PORPs and 18 dB for TORPs. In the long-term, average ABG improved by 2.3 dB in PORPs and 13.4 dB in TORPs. PORPs had higher rates of ABG closure and lower AC PTAs than TORPs in the long-term. DISCUSSION: Endoscopic ossiculoplasty is a viable option in children presenting with ossicular erosion from various causes. Audiometric improvement following endoscopic partial and total ossicular reconstruction remains stable over time, with a preference towards partial in the long-term, and mirrors published outcomes for microscopic surgery.


Assuntos
Prótese Ossicular , Substituição Ossicular , Adulto , Humanos , Masculino , Criança , Feminino , Titânio , Implantação de Prótese , Orelha Média , Estudos Retrospectivos , Resultado do Tratamento
2.
Otol Neurotol ; 45(6): 627-634, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38865719

RESUMO

OBJECTIVE: To compare the rate of device failure for those cochlear implants (CIs) involved in the 2020 Food and Drug Administration (FDA) voluntary field corrective action (VFCA). DATABASES REVIEWED: Medline, Embase, and Scopus. METHODS: A systematic review was performed according to the PRISMA guidelines. Publications reporting institutional experiences with implants affected by the VFCA were included. Outcomes assessed included etiology of, rate of, and time to failure and pre-/post-device failure speech perception testing. All outcomes reported in at least two independent studies were included in a meta-analysis. RESULTS: Six studies met criteria for analysis. The overall pooled failure rate was 23.7% (95% CI, 11.6-38.4%). The pooled device, inconclusive, and medical failure rates were 21.5%, 0.2%, and 0.7%, respectively. Pediatric failure rates were higher than those of adults (46.9% [95% CI, 11.2-84.5%] versus 32.6% [95% CI, 8.2-63.7%]). WRS declined with primary implant failure (55.1% [95% CI, 48.0-62.1%] to 34.1% [95% CI, 30.2-38.0%]) but improved after reimplantation (34.1% [95% CI, 30.2-38.0%] to 50.1% [95% CI, 45.2-55.1%]). CONCLUSIONS: The rate of pooled reported failure for CIs falling under the 2020 VFCA in the literature thus far is 23.7%. The overwhelming majority of these failures were device related, the rates of which were higher in children. Speech perception improved significantly after reimplantation.


Assuntos
Implantes Cocleares , Falha de Prótese , United States Food and Drug Administration , Humanos , Estados Unidos , Implante Coclear , Percepção da Fala/fisiologia
3.
Otol Neurotol ; 45(4): 404-409, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38361328

RESUMO

OBJECTIVE: To examine the role of lumbar drains (LDs) in the success of spontaneous temporal cerebrospinal fluid (CSF) leak and encephalocele repair. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary academic health system. PATIENTS: Patients undergoing repair of spontaneous temporal lobe encephaloceles or middle fossa CSF leaks during years 2017 to 2023. INTERVENTIONS: Transmastoid, middle fossa craniotomy, or combination approaches to CSF leak repair. OUTCOME MEASURES: Failure rate, complication rate, length of stay (LOS), readmission. RESULTS: Sixty-nine patients were included, with a combination approach performed in 78.3%, transmastoid in 17.4%, and isolated middle fossa craniotomy in 4.3%. Mean body mass index was 33.2, mean bony defect size width was 6.51 mm, and defect locations included the epitympanum, antrum, mastoid, and petrous apex. Multilayer closure with three or more layers was performed in 87.0%. LD was used in 73.9% of cases for a mean duration 2.27 days and was associated with longer LOS (3.27 vs. 1.56 d, p = 0.006) but not with failure rate, complications, discharge destination, or readmission. Only one major complication occurred as a result of the drain, but low-pressure headache was anecdotally common. CONCLUSIONS: Use of LD in the repair of spontaneous CSF leaks and temporal lobe encephaloceles is associated with longer LOS but not failure rates or other admission-level outcomes.


Assuntos
Vazamento de Líquido Cefalorraquidiano , Encefalocele , Humanos , Encefalocele/complicações , Estudos Retrospectivos , Vazamento de Líquido Cefalorraquidiano/complicações , Processo Mastoide/cirurgia , Lobo Temporal , Resultado do Tratamento
4.
Otol Neurotol ; 45(3): 266-272, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238911

RESUMO

OBJECTIVE: To determine whether surgeon use of a soft cervical collar during endoscopic and microscopic otologic surgery is feasible and impacts surgeon ergonomics as measured by inertial sensors. STUDY DESIGN: Prospective crossover trial. SETTING: US-based otolaryngology training program. PATIENTS: Otolaryngology residents and fellows. INTERVENTIONS: Therapeutic-use of a soft cervical collar during simulated otologic surgery. MAIN OUTCOME MEASURES: Time spent in high-risk angles of neck and back flexion and extension; average angle of neck flexion, extension, rotation, and lateral bending; validated assessment of neck pain; average daily phone use. RESULTS: Fifteen subjects met criteria for inclusion. Ten of 15 (67%) were male. Seven of 15 (47%) were postgraduate year 1-2. Seven of 15 (47%) reported a history of neck pain. None reported prior spinal steroid injections or surgery. Across all subjects, use of the soft cervical collar significantly reduced time spent in high-risk angles of neck flexion/extension during both endoscopic (56% vs. 35%, p < 0.05) and microscopic (60% vs. 32%, p < 0.05) otologic surgery. There was no effect on back flexion or extension. There was no difference in time spent in high-risk neck or back angles between endoscopic and microscopic surgery. Average angles of neck or back flexion, extension, lateral bending, and rotation were not significantly different for subgroups with more operative experience, increased phone use, perception of good posture, or history of neck pain. CONCLUSIONS: Use of a soft cervical collar during simulated otologic surgery significantly reduced time spent in high-risk neck positions. These data support feasibility of soft collar use during otologic surgery and hold promise for reduction in the high rates of neck pain reported by neurotologists. PROFESSIONAL PRACTICE GAP AND EDUCATIONAL NEED: Improving surgeon ergonomics for otologic surgery. LEARNING OBJECTIVE: To identify a therapeutic intervention to mitigate neck pain in surgeons caused by assumption of high-risk cervical neck flexion and extension. DESIRED RESULT: To demonstrate that use of a readily available soft cervical collar reduces risk of neck pain in otologic surgeons. LEVEL OF EVIDENCE: II. INDICATE IRB OR IACUC: Exempt.


Assuntos
Cervicalgia , Cirurgiões , Feminino , Humanos , Masculino , Vértebras Cervicais/cirurgia , Ergonomia , Pescoço/cirurgia , Cervicalgia/prevenção & controle , Estudos Prospectivos , Amplitude de Movimento Articular , Estudos Cross-Over
5.
Electron. j. biotechnol ; 25: 39-42, ene. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1008418

RESUMO

Background: Invert sugar is used greatly in food and pharmaceutical industries. This paper describes scaling-up batch conditions for sucrose inversion catalyzed by the recombinant Pichia pastoris BfrA4X whole cells expressing Thermotoga maritima invertase entrapped in calcium alginate beads. For the first time, we describe the application of a kinetic model to predict the fractional conversion expected during sucrose hydrolysis reaction in both, a model and a prototype bioreactor with 0.5- and 5-L working volume, respectively. Results: Different scaled-up criteria used to operate the 0.5-L bioreactor were analyzed to explore the invert sugar large scale production. After model inversion studies, a 5-L scaled-up reaction system was performed in a 7-L stirred reactor. Both scaled-up criteria, immobilized biocatalyst dosage and stirring speed, were analyzed in each type of bioreactors and the collected data were used to ensure an efficient scale-up of this biocatalyst. Conclusions: To date, there is not enough information to describe the large-scale production of invert sugar using different scaled-up criteria such as dose of immobilized biocatalyst and stirring speed effect on mass transfer. The present study results constitute a valuable tool to successfully carry out this type of high-scale operation for industrial purposes.


Assuntos
Pichia/metabolismo , Sacarose/metabolismo , Biotecnologia/métodos , Pichia/citologia , Sacarose/química , Cinética , Reatores Biológicos , Thermotoga maritima/enzimologia , Alginatos , Enzimas Imobilizadas , Biocatálise , Hidrólise
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa