Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(4): 2283-2293, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37816923

RESUMO

OBJECTIVES: The aim of this study was to develop and validate an algorithm for the non-invasive diagnosis of these fat-containing HCCs. METHODS: Eighty-four cirrhotic patients with 77 fat-containing HCCs and 11 non-HCC fat-containing nodules were retrospectively included. All MRIs were reviewed; nodule characteristics, European Association for the Study of the Liver (EASL) and LI-RADS classifications, and survival were collected. One of the major features of LI-RADS v2018 (non-rim-like arterial phase hyperenhancement [APHE]) was changed to include different enhancing patterns at arterial phase and a new fat-LI-RADS algorithm was created for fat-containing nodules in cirrhosis. Its diagnostic performance was evaluated in both a derivation and external validation cohort (external cohort including 58 fat-containing HCCs and 10 non-HCC fat nodules). Reproducibility of this new algorithm was assessed. RESULTS: In the derivation cohort, 54/77 (70.1%) fat-containing HCCs had APHE, 62/77 (80.5%) had enhancement compared to the nodule itself at arterial phase (APE), 43/77 (55.8%) had washout, and 20/77 (26.0%) had an enhancing capsule. EASL and LI-RADS had a sensitivity of 37.7% (29/77) and 36.4% (28/77), respectively, for the diagnosis of fat-containing HCC and both had a specificity of 100% (11/11). The new fat-LI-RADS algorithm increased sensitivity to 50.6% (39/77) without decreasing the specificity of 100% (11/11). The validation cohort confirmed the increased sensitivity, with a slight decrease in specificity. The concordance for the diagnosis of HCC for fat-LR5 was 85.3% (58/68). CONCLUSION: The new fat-LI-RADS algorithm proposed here significantly improves the performance of the non-invasive diagnosis of fat-containing HCC and thus could reduce the number of biopsies conducted for fat-containing HCCs. CLINICAL RELEVANCE STATEMENT: The European Association for the Study of the Liver and LI-RADS guidelines are poorly sensitive for the diagnosis of fat-containing HCC, mainly because of the low rate of arterial phase hyperenhancement (APHE) displayed by fat-containing HCC. Using all types of enhancement instead of APHE improves sensitivity of LI-RADS. KEY POINTS: • Fat-containing HCCs on MRI account for 7.5% of HCCs and have different imaging characteristics from non-fatty HCCs. • The European Association for the Study of the Liver and LI-RADS algorithms for the non-invasive diagnosis of HCC have low sensitivity for the diagnosis of fat-containing HCC with MRI (37.7% and 36.4%, respectively). • The new fat-LI-RADS, which includes a slight modification of the "arterial enhancement" criterion, improves the sensitivity for the diagnosis of fat-containing HCC using MRI, without degrading the specificity.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Meios de Contraste , Sensibilidade e Especificidade , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
2.
Hepatology ; 76(5): 1318-1328, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35349760

RESUMO

BACKGROUND & AIMS: The diagnostic accuracy of Liver Imaging Reporting and Data System (LI-RADS) v.2018 and European Association for the Study of the Liver (EASL) criteria for the diagnosis of HCC have been widely evaluated, but their reliability should be investigated. We aimed to assess and compare the reliability of LI-RADS v.2018 and EASL criteria for the diagnosis of HCC using MRI with extracellular contrast agents (ECAs) and gadoxetic acid (GA) and determine the effect of ancillary features on LI-RADS reliability. APPROACH & RESULTS: Ten readers reviewed MRI studies of 92 focal liver lesions measuring <3 cm acquired with ECAs and GA <1 month apart from two prospective trials, assessing EASL criteria, LI-RADS major and ancillary features, and LI-RADS categorization with and without including ancillary features. Inter-reader agreement for definite HCC diagnosis was substantial and similar for the two contrasts for both EASL and LI-RADS criteria. For ECA-MRI and GA-MRI, respectively, inter-reader agreement was k = 0.72 (95% CI, 0.63-0.81) and k = 0.72 (95% CI, 0.63-0.80); for nonrim hyperenhancement, k = 0.63 (95% CI, 0.54-0.72) and k = 0.57 (95% CI, 0.48-0.66); and for nonperipheral washout, k = 0.49 (95% CI, 0.40-0.59) and k = 0.48 (95% CI, 0.37-0.58) for enhancing capsule. The inter-reader agreement for LI-RADS after applying ancillary features remained in the same range of agreement. CONCLUSIONS: Agreement for definite HCC was substantial and similar for both scoring systems and the two contrast agents in small focal liver lesions. Agreement for LI-RADS categorization was lower for both contrast agents, and including LI-RADS ancillary features did not improve agreement.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Meios de Contraste , Sistemas de Dados , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
3.
World J Surg ; 47(4): 975-984, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36648518

RESUMO

BACKGROUND: Identifying the 30% of adhesive small bowel obstructions (aSBO) for which conservative management will require surgery is essential. The association between the previously described radiological score and failure of the conservative management of aSBO remains to be confirmed in a large prospective multicentric cohort. Our aim was to assess the risk factors of failure of the conservative management of aSBO considering the radiological score. MATERIAL AND METHODS: This prospective observational study took place in 15 French centers over 3 months. Consecutive patients experiencing aSBO with no early surgery were included. The six radiological features from the Angers radiological computed tomography (CT) score were noted (beak sign, closed loop, focal or diffuse intraperitoneal liquid, focal or diffuse mesenteric haziness, focal or diffuse mesenteric liquid, and diameter of the most dilated small bowel loop > 40 mm). RESULTS: Two hundred and seventy nine patients with aSBO were screened. Sixty patients (21.5%) underwent early surgery, and 219 (78.5%) had primary conservative management. In the end, 218 patients were included in the analysis of the risk factors for conservative treatment failure. Among them, 162 (74.3%) had had successful management while for 56 (25.7%) management had failed. In multivariate analysis, a history of surgery was not a significant risk factor for the failure of conservative treatment (OR = 0.11; 95%CI = 0-1.23). A previous episode of aSBO was protective against the failure of conservative treatment (OR = 0.36; 95%CI = 0.15-0.85) and an Angers CT score ≥ 5 as the only individual risk factor (OR = 2.39; 95%CI = 1.01-5.69). CONCLUSION: The radiological score of aSBO is a promising tool in improving the management of aSBO patients. A first episode of aSBO and/or a radiological score ≥5 should lead physicians to consider early surgical management.


Assuntos
Tratamento Conservador , Obstrução Intestinal , Humanos , Aderências Teciduais/diagnóstico por imagem , Aderências Teciduais/etiologia , Aderências Teciduais/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Tomografia Computadorizada por Raios X , Fatores de Risco , Ira , Resultado do Tratamento
4.
Acta Radiol ; 64(5): 1730-1737, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36617943

RESUMO

BACKGROUND: Early detection can prevent the initial stages of fibrosis from progressing to cirrhosis. PURPOSE: To evaluate an algorithm combining three echographic indicators and elastographic measurements to screen for hepatic fibrosis in an unselected population. MATERIAL AND METHODS: From May 2017 to June 2018, all patients with no history and no known chronic liver disease who were referred for an ultrasound (US) were prospectively included in eight hospitals. The indicators being sought were liver surface irregularity, demodulation of hepatic veins, and spleen length >110 mm. Patients presenting at least one of these underwent elastography measurements with virtual touch quantification (VTQ) or supersonic shear imaging (SSI). If elastography was positive, patients were referred to hepatologist for fibrosis evaluation. Reference standard was obtained by FibroMeterVCTE or biopsy. A FibroMeterVCTE result >0.384 indicated a "necessary referral" to a hepatologist. RESULTS: Of the 1501 patients included, 504 (33.6%) were positive for at least one US indicator. All of them underwent US elastography, with 85 being positive. Of the patients, 58 (3.6%) had a consultation with a liver specialist: 21 had positive FibroMeterVCTE and nine had an indication of biopsy for suspicion of fibrosis. This screening algorithm made it possible to diagnose 1.6% of patients in our population with unknown fibrosis. Of the patients, 50% referred to the liver specialist were "necessary referrals." CONCLUSION: Our study suggests that three simple US indicators with no systematic elastographic measurement could be applied in day-to-day practice to look for hepatic fibrosis in an unsuspected population allowing relevant referrals to a hepatologist.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Fibrose , Algoritmos , Ultrassonografia Doppler
5.
Clin Gastroenterol Hepatol ; 20(2): 400-408.e10, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33340779

RESUMO

BACKGROUND & AIMS: Two-dimensional shear wave elastography (2D-SWE) is an accurate method for the non-invasive evaluation of liver fibrosis. We aimed to determine the reliability criteria and the number of necessary reliable measurements for 2D-SWE. METHODS: 788 patients with chronic liver disease underwent liver biopsy and 2D-SWE examination in three centers. The 4277 2D-SWE measurements performed were 2:1 randomly divided into derivation (n = 2851) and validation (n = 1426) sets. Reliability criteria for a 2D-SWE measurement were defined in the derivation set from the intrinsic characteristics given by the device (mean liver stiffness, standard deviation, diameter of the region of interest), with further evaluation in the validation set. RESULTS: In the whole population of 4277 measurements, AUROC for bridging fibrosis was 0.825 ± 0.006 and AUROC for cirrhosis was 0.880 ± 0.006. Mean stiffness and coefficient of variation (CV) were independent predictors of bridging fibrosis or cirrhosis. From these two parameters, new criteria were derived to define a reliable 2D-SWE measurement: stiffness <8.8 kPa, or stiffness between 8.8-11.9 kPa with CV <0.25, or stiffness ≥12.0 kPa with CV <0.10. In the validation set, AUROC for bridging fibrosis was 0.830 ± 0.013 in reliable measurements vs 0.667 ± 0.031 in unreliable measurements (P < .001). AUROC for cirrhosis was 0.918±0.014 vs 0.714 ± 0.027, respectively (P < .001). The best diagnostic accuracy for a 2D-SWE examination was achieved from three reliable measurements. CONCLUSIONS: Reliability of a 2D-SWE measurement relies on the coefficient of variation and the liver stiffness level. A 2D-SWE examination should include three reliable measurements according to our new criteria.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatias , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/patologia , Reprodutibilidade dos Testes
6.
Hepatology ; 73(6): 2196-2205, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33236409

RESUMO

BACKGROUND AND AIMS: The combination of laboratory and elastography tests allows the accurate diagnosis of advanced liver fibrosis in patients with NAFLD. In this study, we compared the diagnostic performances of a two-step strategy (laboratory tests and vibration-controlled transient elastography [VCTE] or two-dimensional shear-wave elastography with SuperSonic Imagine [2D-SWE-SSI]) and the added value of a three-step strategy (laboratory tests and two elastography methods). APPROACH AND RESULTS: From a prospective registry, we retrospectively selected 577 consecutive patients with suspicion of NAFLD who underwent laboratory tests to calculate the Fibrosis-4 (FIB-4) score, liver stiffness evaluation by VCTE (M and XL probes) and 2D-SWE-SSI, and liver biopsy. The diagnostic performances and need for liver biopsy in unclassified patients for the diagnosis of advanced fibrosis (F ≥ 3) in multistep strategies were compared. The area under the curve of FIB-4, VCTE, and 2D-SWE-SSI was 0.74, 0.82, and 0.88, respectively. Using the same thresholds, the FIB-4/2D-SWE-SSI and FIB-4/VCTE diagnostic performances were comparable (sensitivity, 71.4% and 66%; specificity, 91.4% and 91.5%; and accuracy, 83.7% and 81.4%; all P = not significant). Conversely, more patients required liver biopsy after 2D-SWE-SSI (24.6% versus 15.3%, P < 0.001). Performing a second elastography technique in patients with unreliable or gray zone (between 8 and 10 kPa) results greatly decreased the need for liver biopsy (42/577, 7.3%). The diagnostic performances (accuracy, sensitivity, and specificity) of FIB-4/2D-SWE-SSI/VCTE and FIB-4/VCTE/2D-SWE-SSI were comparable (81.1%, 71.5%, and 87.9% versus 81.3%, 69.7%, and 89.5%, respectively; all P = not significant). CONCLUSIONS: Using the same cutoff values, 2D-SWE-SSI is as accurate as VCTE for advanced liver fibrosis diagnosis in NAFLD. The three-step strategy in selected patients strongly decreased the need for liver biopsy while maintaining excellent accuracy.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatia Gordurosa não Alcoólica/complicações , Adulto , Idoso , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Sistema de Registros , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Liver Int ; 42(4): 905-917, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34894060

RESUMO

BACKGROUND & AIMS: Long-term outcomes after percutaneous radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD) have been poorly studied. We aim to determine the outcomes after multibipolar RFA in these patients compared to other aetiologies as well as the prognostic impact of metabolic syndrome (MS). METHODS: Patients who underwent multibipolar RFA as the first treatment for HCC within Milan criteria (2008-2018) were enrolled in this multicentre retrospective cohort from four tertiary centres in France. The association of MS and NAFLD with adverse events and outcomes after percutaneous RFA were assessed using Kaplan Meier method, log-rank test and uni/multivariate analysis with the Cox models. RESULTS: Among 520 patients, 390 patients (75%) had at least one component of MS including obesity (30%) and 95% had cirrhosis. Sixty-two patients (12.6%) had NAFLD-HCC, 225 (45.5%) had alcohol-related-HCC, 36 (7.3%) had HBV-HCC and 171 (34.6%) had HCV-HCC. Patients with NAFLD-HCC were significantly older (median age 72.6 years, P < .001), more obese (median BMI 30.3 kg/m2 , P < .001) and had more components of MS. Patients with NAFLD-HCC achieved a median overall survival (OS) of 79 months (1-year, 3-year and 5-year OS of 90%, 71% and 59%). There were no differences in morbidity, tumour recurrence and OS among patients with NAFLD-HCC vs other aetiologies as well as no prognostic impact of metabolic components. CONCLUSIONS: Percutaneous multibipolar RFA is an efficient treatment in HCC patients with NAFLD or metabolic syndrome and achieved similar long-term oncological outcomes compared to other aetiologies.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Hepatopatia Gordurosa não Alcoólica , Ablação por Radiofrequência , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva Local de Neoplasia , Hepatopatia Gordurosa não Alcoólica/etiologia , Ablação por Radiofrequência/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
8.
Ultraschall Med ; 43(5): 479-487, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32992377

RESUMO

PURPOSE: The aim of this study was to evaluate the hepatorenal index ratio of Supersonic Imagine (B-mode ratio) and the controlled attenuation parameter (CAP) of FibroScan for the noninvasive diagnosis and grading of steatosis. MATERIALS AND METHODS: Two centers prospectively included patients who underwent liver biopsy, B-mode ratio and CAP evaluation all on the same day between June 2017 and July 2019. MRI and histological morphometry were also performed in center 1. Histology (classic semiquantitative score and morphometry) was used as the reference. RESULTS: Concerning the B-mode ratio, the AUROCs for ≥ S1, ≥ S2 and ≥ S3 were respectively 0.896 ±â€Š0.20, 0.775 ±â€Š0.30 and 0.729 ±â€Š0.39 with the best cut-off values being 1.22 for ≥ S1 (Se = 76.4 %, Sp = 93.2 %), 1.42 for ≥ S2 (Se = 70.2 %, Sp = 71.2 %) and 1.54 for ≥ S3 (Se = 68.4 %, Sp = 69.8 %). The correlation between the B-mode ratio and morphometry was moderate (Rs = 0.575, p < 0.001) and the correlation between the B-mode ratio and MRI was good (Rs = 0.613, p < 0.001). Concerning the CAP, the AUROCs for ≥  S1, ≥ S2 and ≥ S3 were 0.926 ±â€Š0.18, 0.760 ±â€Š0.30 and 0.701 ±â€Š0.40, respectively, with the best cut-off values being 271 dB/m for ≥ S1 (Se = 84 %, Sp = 88.2 %), 331 dB/m for ≥ S2 (Se = 64.5 %, Sp = 74.7 %) and 355 dB/m for ≥ S3 (Se = 55.3 %, Sp = 75.1 %). The correlation between the CAP and morphometry and between the CAP and MRI was moderate in both cases (Rs = 0.526, p < 0.001 and Rs = 0.397, p < 0.001, respectively). The B-mode ratio was better at ruling in and the CAP was better at ruling out the disease. CONCLUSION: B-mode ratio and CAP show similar and good performance for the diagnosis of steatosis (≥ S1). However, both techniques are limited with respect to differentiating mild to moderate (≥ S2) or severe (≥ S3) steatosis.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado Gorduroso , Área Sob a Curva , Biópsia , Técnicas de Imagem por Elasticidade/métodos , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Valor Preditivo dos Testes , Curva ROC
10.
AJR Am J Roentgenol ; 216(6): 1530-1538, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33881897

RESUMO

OBJECTIVE. The purpose of this multicenter retrospective study was to assess the MRCP features of Caroli disease (CD). MATERIALS AND METHODS. Sixty-six patients were identified from 2000 to 2019. The inclusion criteria were diagnosis of diffuse or localized CD mentioned in an imaging report, presence of intrahepatic bile duct (IHBD) dilatation, and having undergone an MRCP examination. The exclusion criteria included presence of obstructive proximal biliary stricture and having undergone hepatobiliary surgery other than cholecystectomy. Histopathology records were available for 53 of the 66 (80%) patients. Diffuse and localized diseases were compared by chi-square and t tests and Kaplan-Meier model. RESULTS. Forty-five patients had diffuse bilobar CD ((five pediatric patients [three girls and two boys] with a mean [± SD] age of 8 ± 5 years [range, 1-15 years] and 40 adult patients [26 men and 14 women] with a mean age of 35 ± 11 years [range, 20-62 years]) and 21 patients had localized disease (12 men and 9 women; mean age, 54 ± 14 years). Congenital hepatic fibrosis was found only in patients with diffuse CD (35/45 [78%]), as was a "central dot" sign (15/35 [43%]). IHBD dilatation with both saccular and fusiform features was found in 43 (96%) and the peripheral "funnel-shaped" sign in 41 (91%) of the 45 patients with diffuse CD but in none of the patients with localized disease (p < .001). Intrahepatic biliary calculi were found in all patients with localized disease but in only 16 of the 45 (36%) patients with diffuse CD (p < .001). Left liver atrophy was found in 18 of the 21 (86%) patients with localized disease and in none of the patients with diffuse CD (p < .001). The overall survival rate among patients with diffuse CD was significantly lower than that among patients with localized disease (p = .03). CONCLUSION. Diffuse IHBD dilatation with both saccular and fusiform features associated with the peripheral funnel-shaped sign can be used for the diagnosis of CD on MRCP. Localized IHBD dilatation seems to be mainly related to primary intrahepatic lithiasis.


Assuntos
Doença de Caroli/diagnóstico por imagem , Colangiopancreatografia por Ressonância Magnética/métodos , Adolescente , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Taxa de Sobrevida
11.
J Hepatol ; 72(5): 937-945, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31870951

RESUMO

BACKGROUND & AIMS: The aim of this study was to use a head-to-head nodule comparison to compare the performance of extracellular contrast agent MRI (ECA-MRI) with that of hepatobiliary contrast agent MRI (HBA-MRI) for the non-invasive diagnosis of small hepatocellular carcinomas (HCCs). METHODS: Between August 2014 and October 2017, 171 patients with cirrhosis, each with 1 to 3 nodules measuring 1-3 cm, were enrolled across 8 centers. All patients underwent both an ECA-MRI and an HBA-MRI within a month. A non-invasive diagnosis of HCC was made when a nodule exhibited arterial phase hyper-enhancement (APHE) with washout at the portal venous phase (PVP) and/or delayed phase (DP) for ECA-MRI, or the PVP and/or HB phase (HBP) for HBA-MRI. The gold standard was defined by using a previously published composite algorithm. RESULTS: A total of 225 nodules, of which 153 were HCCs and 72 were not, were included. The sensitivites of both MRI techniques were similar. Specificity was 83.3% (95% CI 72.7-91.1) for ECA-MRI and 68.1% (95% CI 56.0-78.6) for HBA-MRI. In terms of HCC diagnosis on ECA-MRI, 138 nodules had APHE, 84 had washout at PVP, and 104 at DP; on HBA-MRI, 128 nodules had APHE, 71 had washout at PVP, and 99 at HBP. For nodules 2-3 cm in size, sensitivity and specificity were similar between the 2 approaches. For nodules 1-2 cm in size, specificity dropped to 66.1% (95% CI 52.2-78.2) for HBA-MRI vs. 85.7% (95% CI 73.8-93.6) for ECA-MRI. CONCLUSIONS: HBA-MRI specificity is lower than that of ECA-MRI for diagnosing small HCCs in patients with cirrhosis. These results raise the question of the proper use of HBA-MRI in algorithms for the non-invasive diagnosis of small HCCs. LAY SUMMARY: There are 2 magnetic resonance imaging (MRI)-based approaches available for the non-invasive diagnosis of hepatocellular carcinoma (HCC), using either extracellular or hepatobiliary contrast agents. The current results showed that the sensitivity of MRI with hepatobiliary contrast agents was similar to that with extracellular contrast agents, but the specificity was lower. Thus, hepatobiliary contrast agent-based MRI, although detailed in international guidelines, should be used with caution for the non-invasive diagnosis of HCC. CLINICAL TRIAL NUMBER: NCT00848952.


Assuntos
Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Algoritmos , Carcinoma Hepatocelular/epidemiologia , Feminino , Humanos , Cirrose Hepática/epidemiologia , Neoplasias Hepáticas/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , República da Coreia/epidemiologia , Sensibilidade e Especificidade
12.
Radiology ; 292(1): 94-100, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31135296

RESUMO

Background Debate continues about the risks and benefits of systematic whole-body CT when no injury is clinically suspected. Risks of whole-body CT include high radiation exposure and iodine contrast agent, but its effectiveness in reducing mortality in low-risk motor vehicle crashes is unclear. Purpose To assess unsuspected injuries revealed at whole-body CT in patients following motor vehicle crash (MVC) meeting only kinetic elements of the Vittel criteria for the severity of trauma, with no evidence of trunk injury and a Glasgow Coma Scale score of 15. Materials and Methods This retrospective study included all consecutive adult patients who consulted an emergency department of a level 1 trauma center between August 2016 and July 2017 if they underwent whole-body CT for one or more kinetic elements of the Vittel criteria, had a normal examination of the trunk, and had a Glasgow Coma Scale score of 15. Data of the MVC mechanism and physical and biologic examinations were collected, as well as patient treatment data after whole-body CT. Whole-body CT examinations were read by two double-blinded readers to help detect unsuspected injuries. Results Ninety-three patients were included; 72 were men with a mean age of 30.8 years ± 12.0 (standard deviation). Sixty-nine patients were occupants of a car. Seventeen patients were hit by a car while on motorbikes, three while on bicycles, and four as pedestrians. Unsuspected injuries were depicted at 11 whole-body CT examinations: eight lung contusions, one acetabular fracture, one sternal fracture, and one adrenal hematoma. None of these injuries required a specific treatment. One patient with lung contusion of more than 30% of lung volume was followed without requiring further treatment. Conclusion In this population, whole-body CT did not lead to any change in patient treatment. These results suggest whole-body CT should not be systematically performed when no evidence of trunk injury is observed in patients following motor vehicle crash meeting only kinetic elements of Vittel criteria. © RSNA, 2019 See also the editorial by Munera and Durso in this issue.


Assuntos
Acidentes de Trânsito , Exame Físico/métodos , Exame Físico/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Imagem Corporal Total/estatística & dados numéricos , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Eur Radiol ; 28(5): 2022-2030, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29178028

RESUMO

OBJECTIVES: To evaluate the performance and limitations of the R2* and signal intensity ratio (SIR) methods for quantifying liver iron concentration (LIC) at 3 T. METHODS: A total of 105 patients who underwent a liver biopsy with biochemical LIC (LICb) were included prospectively. All patients underwent a 3-T MRI scan with a breath-hold multiple-echo gradient-echo sequence (mGRE). LIC calculated by 3-T SIR algorithm (LICSIR) and by R2* (LICR2*) were correlated with LICb. Sensitivity and specificity were calculated. The comparison of methods was analysed for successive classes. RESULTS: LICb was strongly correlated with R2* (r = 0.95, p < 0.001) and LICSIR (r = 0.92, p < 0.001). In comparison to LICb, LICR2* and LICSIR detect liver iron overload with a sensitivity/specificity of 0.96/0.93 and 0.92/0.95, respectively, and a bias ± SD of 7.6 ± 73.4 and 14.8 ± 37.6 µmol/g, respectively. LICR2* presented the lowest differences for patients with LICb values under 130 µmol/g. Above this value, LICSIR has the lowest differences. CONCLUSIONS: At 3 T, R2* provides precise LIC quantification for lower overload but the SIR method is recommended to overcome R2* limitations in higher overload. Our software, available at www.mrquantif.org , uses both methods jointly and selects the best one. KEY POINTS: • Liver iron can be accurately quantified by MRI at 3 T • At 3 T, R2* provides precise quantification of slight liver iron overload • At 3 T, SIR method is recommended in case of high iron overload • Slight liver iron overload present in metabolic syndrome can be depicted • Treatment can be monitored with great confidence.


Assuntos
Sobrecarga de Ferro/diagnóstico por imagem , Sobrecarga de Ferro/metabolismo , Fígado/metabolismo , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Algoritmos , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Curr Med Imaging ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38449068

RESUMO

OBJECTIVE: To evaluate the usefulness of unenhanced CT added to the portal venous phase in the diagnostic accuracy of acute colonic diverticulitis/sigmoiditis. METHODS: Between January 1st and December 31st, 2020, all consecutive adult patients referred to the radiology department for clinical suspicion of acute colonic diverticulitis/sigmoiditis were retrospectively screened. To be included, patients must have undergone a CT with both unenhanced (UCT) and contrast-enhanced portal venous phase CT (CECT). CT examinations were assessed for features of diverticulitis, complications, differential diagnosis and incidental findings using UCT + CECT association, medical management, and follow-up as the reference. Radiation doses were recorded on our image archiving system and assessed. RESULTS: Of the 114 patients included (mean age was 67±18 years; 60% were female), 46 had acute colonic diverticulitis/sigmoiditis. No diagnosis of sigmoiditis/diverticulitis, complication or differential diagnosis was missed with the CECT alone. Apart from diverticulitis, only one 2 mm meatal urinary microlithiasis was missed with no impact on patient management. The confidence level in diagnosis was not increased by UCT. The average DLP of CECT was 450 mGy.cm, and 382 mGy.cm for UCT. The use of a single-phase CECT acquisition allowed a reduction of 45.9% of the irradiation. CONCLUSION: Unenhanced CT is not necessary for patients addressed with clinical suspicion of acute colonic diverticulitis/sigmoiditis, and CECT alone protocol must be used.

18.
Abdom Radiol (NY) ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954002

RESUMO

PURPOSE: Preoperative imaging is now recommended in patients with suspected acute appendicitis (AA) by the World Society of Emergency Surgery. Our aims were (i) to describe our local practice and (ii) to evaluate the efficiency of performing ultrasound (US) and/or computed tomography (CT) by assessing management failure, specificity and sensitivity, and length of stay in the emergency department (ED). METHODS: This single-center retrospective study included all patients who underwent US or CT for the management of suspected AA. Patients were included if they were admitted to the ED in February or June between 2012 and 2021. RESULTS: The study included 339 patients. US was performed in 278 patients (82%), of whom 91 also had a second-line CT (31.3%). There was a significant increase in the rate of CT over the inclusion period. Three percent (3%) of the patients had management failure and a higher age and CT or US + CT were significantly associated with the risk of management failure. Length of stay in the ED increased significantly when a second-line CT was performed. The sensitivity and specificity of US were 84.8% and 93.2%, respectively. Sensitivity was significantly different from CT (100%, p = 0.03) but not specificity (87.9%, p = 0.29). Both US and CT results were more likely to be considered for further management if positive. The vast majority of patients with negative or inconclusive results were admitted in surgical wards or underwent a second-line examination. CONCLUSION: If available in the hospital together with CT, US should probably be performed systematically and as a first-line examination in patients with suspected acute appendicitis.

19.
Hepatology ; 65(6): 2119-2120, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28066931
20.
Insights Imaging ; 14(1): 142, 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37644337

RESUMO

OBJECTIVES: To develop and validate European entrustable professional activities (EPAs) for sub-specialised hepatobiliary and gastrointestinal (HB/GI) diagnostic imaging. MATERIALS AND METHODS: Both European Society of Radiology and national curricula in HB/GI diagnostic radiology were thoroughly reviewed, resulting in preliminary EPAs drafted by a pilot group of expert radiologists in 2 different countries. Each EPA was fully described with 7 components (Specification/limitations; Potential risks of failing; Relevant domains of competence; Required experience, knowledge, skills, attitude and behaviour; Assessment information sources to assess progress and ground a summative entrustment decision; Entrustment for which level of supervision is to be reached; and Expiration date). The modified Delphi method with 3 Delphi rounds was chosen for validation. Content validity index (CVI) and median values were used for validation. RESULTS: There were 15 preliminary EPAs, some of them divided according to 2 levels: resident and fellow level. The 37 members of the Delphi group were based in 2 different European countries with a background experience of 10 represented countries. Subsequent to the first Delphi round, 6 EPAs were accepted (CVI ≥ 0.8, median ≥ 4), 6 needed major revisions (CVI 0.7-0.79, median ≥ 4), 3 were rejected (CVI < 0.7) and 1 was added. After the second Delphi round, both the 6 revised EPAs and the additional one met the validation criteria (CVI ≥ 0.8, median ≥ 4). Finally, 13 EPAs were validated during the 3rd Delphi round with an agreement percentage of 95-100%. CONCLUSION: This study creates and validates EPAs for sub-specialised HB/GI diagnostic imaging. CRITICAL RELEVANCE STATEMENT: Thirteen EPAs for sub-specialised hepatobiliary and gastrointestinal diagnostic imaging were created with a strong methodology, and as a first example set in sub-specialised diagnostic imaging, they provide a template for others to be created. KEY POINTS: • The competence-based teaching in medical studies has recently been reintroduced through EPAs. • Thirteen EPAs have been developed for hepatobiliary and gastrointestinal sub-specialised diagnostic imaging. • These EPAs were validated using a Delphi modified method and provide a template for other to be created.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa