Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
2.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37387689

RESUMO

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792572

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493490

RESUMO

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Assuntos
Miocardite , Sarcoidose , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/complicações , Prognóstico , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
5.
Br J Clin Pharmacol ; 89(4): 1374-1385, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36321834

RESUMO

AIMS: Many clinical decision support systems trigger warning alerts for drug-drug interactions potentially leading to QT prolongation and torsades de pointes (QT-DDIs). Unfortunately, there is overalerting and underalerting because stratification is only based on a fixed QT-DDI severity level. We aimed to improve QT-DDI alerting by developing and validating a risk prediction model considering patient- and drug-related factors. METHODS: We fitted 31 predictor candidates to a stepwise linear regression for 1000 bootstrap samples and selected the predictors present in 95% of the 1000 models. A final linear regression model with those variables was fitted on the original development sample (350 QT-DDIs). This model was validated on an external dataset (143 QT-DDIs). Both true QTc and predicted QTc were stratified into three risk levels (low, moderate and high). Stratification of QT-DDIs could be appropriate (predicted risk = true risk), acceptable (one risk level difference) or inappropriate (two risk levels difference). RESULTS: The final model included 11 predictors with the three most important being use of antiarrhythmics, age and baseline QTc. Comparing current practice to the prediction model, appropriate stratification increased significantly from 37% to 54% appropriate QT-DDIs (increase of 17.5% on average [95% CI +5.4% to +29.6%], padj = 0.006) and inappropriate stratification decreased significantly from 13% to 1% inappropriate QT-DDIs (decrease of 11.2% on average [95% CI -17.7% to -4.7%], padj ≤ 0.001). CONCLUSION: The prediction model including patient- and drug-related factors outperformed QT alerting based on QT-DDI severity alone and therefore is a promising strategy to improve DDI alerting.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Síndrome do QT Longo , Torsades de Pointes , Humanos , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Interações Medicamentosas , Torsades de Pointes/induzido quimicamente , Torsades de Pointes/prevenção & controle , Antiarrítmicos , Fatores de Risco , Eletrocardiografia
6.
Europace ; 25(3): 873-879, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36695332

RESUMO

AIMS: The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. METHODS AND RESULTS: This multicentre prospective observational study included 267 consecutive patients undergoing a first cryoablation procedure for paroxysmal AF (137 PolarX, 130 AFA-Pro). Kaplan-Meier curves with the log-rank test was used to compare the 1-year freedom from AF recurrence between both groups. Multivariate Cox model was performed to evaluate whether the type of procedure (PolarX vs. AFA-Pro) had an impact on the occurrence of AF recurrences after adjustment on potentially confounding factors. The PolarX reaches lower temperatures than the AFA-Pro (LSPV 52 ± 5, vs. 59 ± 6; LIPV 49 ± 6 vs. 56 ± 6; right superior pulmonary vein: 49 ± 6 vs. 57 ± 7; right inferior pulmonary vein: 52 ± 6 vs. 59 ± 6; P < 0.0001). A higher rate of transient phrenic nerve palsy was found in patients treated with the PolarX system (15% vs. 7%, P = 0.05). After a mean follow-up of 15 ± 5 months, 20 patients (15%) had recurrences in AFA-Pro group and 27 patients (19%) in PolarX group (P = 0.35). Based on survival analysis, no significant difference was observed between both groups with a 12-month free of recurrence survival of 91.2% (85.1-95.4%) vs. 83.7% (76.0%-89.1%) (log-rank test P = 0.11). In multivariate Cox model hazard ratio of recurrence for PolarX vs. AFA-Pro was not significant [HR = 1.6 (0.9-2.8), P = 0.12]. CONCLUSION: PolarX and AFA-Pro have comparable efficacy and safety profiles for pulmonary veins isolation in paroxysmal atrial fibrillation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Estudos Prospectivos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
7.
Europace ; 25(3): 896-904, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36738245

RESUMO

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Seguimentos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Taquicardia/cirurgia , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
8.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37246904

RESUMO

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
9.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38064697

RESUMO

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37671682

RESUMO

AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91 months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71) min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21) min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30 days. CONCLUSIONS: The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fístula Esofágica , Veias Pulmonares , Humanos , Estudos Prospectivos
11.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37772950

RESUMO

AIMS: Brugada syndrome (BrS) is a hereditary arrhythmic disease, associated with sudden cardiac death. To date, little is known about the psychosocial correlates and impacts associated with this disease. The aim of this study was to assess a set of patient-reported psychosocial outcomes, to better profile these patients, and to propose a tailored psychosocial care. METHODS AND RESULTS: Patients were recruited at the European reference Centre for BrS at Universitair Ziekenhuis Brussel, Belgium. Recruitment was undertaken in two phases: phase 1 (retrospective), patients with confirmed BrS, and phase 2 (prospective), patients referred for ajmaline testing who had an either positive or negative diagnosis. BrS patients were compared to controls from the general population. Two hundred and nine questionnaires were analysed (144 retrospective and 65 prospective). Collected patient-reported outcomes were on mental health (12 item General Health Questionnaire; GHQ-12), social support (Oslo Social Support Scale), health-related quality of life, presence of Type-D personality (Type-D Scale; DS14), coping styles (Brief-COPE), and personality dimensions (Ten Item Personality Inventory). Results showed higher mental distress (GHQ-12) in BrS patients (2.53 ± 3.03) than in the general population (P < 0.001) and higher prevalence (32.7%) of Type D personality (P < 0.001) in patients with confirmed Brugada syndrome (BrS +). A strong correlation was found in the BrS + group (0.611, P < 0.001) between DS14 negative affectivity subscale and mental distress (GHQ-12). CONCLUSION: Mental distress and type D personality are significantly more common in BrS patients compared to the general population. This clearly illustrates the necessity to include mental health screening and care as standard for BrS.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicações , Saúde Mental , Estudos Prospectivos , Estudos Retrospectivos , Qualidade de Vida , Medidas de Resultados Relatados pelo Paciente , Eletrocardiografia/métodos
12.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38155611

RESUMO

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Assuntos
Ablação por Cateter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/tratamento farmacológico , Nó Sinoatrial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca
13.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37061847

RESUMO

AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.


Assuntos
Síndrome de Brugada , Adulto , Humanos , Criança , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Testes Genéticos , Arritmias Cardíacas/genética , Cardioversão Elétrica , Prognóstico , Eletrocardiografia/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética
14.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225176

RESUMO

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Transversais , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos
15.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
16.
Pacing Clin Electrophysiol ; 46(10): 1215-1221, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37676730

RESUMO

Video-assisted thoracoscopic surgery (VATS) has revolutionized the approach and management of pulmonary and cardiac diseases, and its applications have significantly expanded in the last two decades. Beyond its established role in thoracic procedures, VATS has also emerged as a valuable technique for various electrophysiological procedures, including pacemaker implantations, ablation procedures, and left atrial appendage exclusion. This paper presents a thorough review of the existing literature on pacing procedures performed using a VATS approach. By analyzing and synthesizing the available studies, we aim to provide an in-depth understanding of the current knowledge and advancements in VATS-based pacing procedures. A key focus of this review is the detailed description of implantation techniques via a VATS approach.


Assuntos
Cardiopatias , Marca-Passo Artificial , Humanos , Cirurgia Torácica Vídeoassistida/métodos
17.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37378419

RESUMO

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Assuntos
Veia Axilar , Venostomia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Veia Axilar/cirurgia , Venostomia/métodos , Veia Subclávia , Punções/métodos , Coração
18.
Clin Auton Res ; 33(1): 51-62, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36645559

RESUMO

PURPOSE: Drug-induced type I Brugada syndrome (BrS) is associated with a ventricular arrhythmia (VA) rate of 1 case per 100 person-years. This study aims to evaluate changes in electrocardiographic (ECG) parameters such as microvolt T wave alternans (mTWA) and heart rate variability (HRV) at baseline and during ajmaline testing for BrS diagnosis. METHODS: Consecutive patients diagnosed with BrS during ajmaline testing with 5-year follow-up were included in this study. For comparison, a negative ajmaline control group and an isoproterenol control group were also included. ECG recordings during ajmaline or isoproterenol test were divided in two timeframes from which ECG parameters were calculated: a 5-min baseline timeframe and a 5-min drug timeframe. RESULTS: A total of 308 patients with BrS were included, 22 (0.7%) of which suffered VAs during follow-up. One hundred patients were included in both isoproterenol and negative ajmaline control groups. At baseline, there was no difference in ECG parameters between control groups and patients with BrS, nor between BrS with and without VAs. During ajmaline testing, BrS with VAs presented longer QRS duration [159 ± 34 ms versus 138 (122-155) ms, p = 0.006], higher maximum mTWA [33.8 (14.0-114) µV versus 8.00 (3.67-28.2) µV, p = 0.001], and lower power in low frequency band [25.6 (5.8-53.8) ms2 versus 129.5 (52.7-286) ms2, p < 0.0001] when compared to BrS without VAs. CONCLUSIONS: Ajmaline induced important HRV changes similar to those observed during isoproterenol. Increased mTWA was observed only in patients with BrS. BrS with VAs during follow-up presented worse changes during ajmaline test, including lower LF power and higher maximum mTWA which were independent predictors of events.


Assuntos
Ajmalina , Síndrome de Brugada , Humanos , Ajmalina/farmacologia , Síndrome de Brugada/diagnóstico , Frequência Cardíaca , Isoproterenol , Arritmias Cardíacas , Eletrocardiografia , Prognóstico
19.
Molecules ; 28(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38067588

RESUMO

Mometasone furoate is a synthetic corticosteroid used in the treatment of skin inflammatory conditions, hay fever and asthma. The industrial manufacturing routes to mometasone furoate are generally accompanied by the formation of numerous process impurities that need to be detected and quantified, as requested by regulatory authorities. The ready availability of such impurities in the required quantity and purity is therefore essential for toxicological studies, analytical method development and process validation. Herein, we report the multi-gram scale preparation of 21'-chloro-(16'α-methyl-3',11',20'-trioxo-pregna-1',4'-dien-17'-yl)-furan-2-carboxylate (mometasone furoate EP impurity C), one of the known impurities of mometasone furoate. This study also includes the systematic investigation of the final acylation step, as well as the characterization of the difuroate enol ether intermediate and its conversion to the target impurity C.


Assuntos
Asma , Pregnadienodiois , Humanos , Furoato de Mometasona , Acilação
20.
Pacing Clin Electrophysiol ; 45(5): 605-611, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35352363

RESUMO

BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Tecnologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa