Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
South Med J ; 115(7): 429-434, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35777749

RESUMO

OBJECTIVES: People with human immunodeficiency virus (HIV) are at an increased risk of developing cardiovascular diseases. Hypertensive emergency (HTNE), a complication of hypertension with potentially serious health implications, has high healthcare utilization. We attempted to determine the association between HIV status and risk for 30-day readmission after index hospitalization for HTNE. METHODS: We used the Nationwide Readmissions Database to identify all of the admissions during 2010-2017 with a primary discharge diagnosis of HTNE. Admissions were stratified by HIV status and comparisons were made with the χ2 test. We investigated predictors of all-cause 30-day readmission via multivariable logistic regression. RESULTS: A total of 612,854 hospitalizations with a primary discharge diagnosis of HTNE were identified, and 4115 (0.7%) were HIV positive. There was a total of 43,937 (7.16%) 30-day readmissions, and the rate was higher in regard to positive HIV status (29.8% vs 15.0%; P < 0.001). Renal failure was the most frequent reason for HIV readmissions and the second most frequent reason for non-HIV readmissions (15.6% vs 10.3%; P < 0.001). In contrast, heart failure was the most frequent reason for non-HIV readmissions and the second most frequent reason for HIV readmissions (10.3% vs 11.9%; P = 0.234). There was a higher median cost for HIV readmissions in comparison to non-HIV readmissions ($7660 vs $7490; P < 0.001). Finally, HIV was attributed to 40.6% increased odds of readmission after adjusting for pertinent clinical and demographic factors (P < 0.001). CONCLUSIONS: HIV-positive status is associated with an increased risk for 30-day readmission after index hospitalization for HTNE.


Assuntos
Infecções por HIV , Readmissão do Paciente , Bases de Dados Factuais , Infecções por HIV/complicações , Infecções por HIV/epidemiologia , Hospitalização , Humanos , Alta do Paciente
2.
Knee Surg Sports Traumatol Arthrosc ; 30(1): 280-287, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33616694

RESUMO

PURPOSE: Chronic grade 3 tears of the medial collateral ligament and posterior oblique ligament may result in valgus laxity and anteromedial rotational instability after an isolated or multiligament injury. The purpose of this study was to prospectively analyze the restoration of physiologic medial laxity as assessed on stress radiography and patient reported subjective functional outcomes in patients who undergo an anatomic medial knee reconstruction. METHODS: This was a prospective study which included patients with chronic (> 6 weeks old) posteromedial corner injury with or without other ligament and meniscus lesions. Pre- and post-operative valgus stress radiographs were performed in 20° knee flexion and functional outcome was recorded as per the International Knee Documentation Committee (IKDC) and Lysholm scores. All patients underwent anatomic medial reconstruction with two femoral and two tibial sockets using ipsilateral hamstring tendon autograft. Simultaneous ligament and meniscus surgery was performed as per the associated injury pattern. All patients were followed up for a minimum of 24 months post-surgery. RESULTS: Thirty-four patients (23 males, 11 females) were enrolled in the study and all were available till final follow-up of mean 49.7 ± 14.9 months. The mean age was 30.6 ± 7.9 (18-52 years). Two patients had isolated medial sided lesions and 23 had associated ligament injuries. The mean follow up was 49.7 (24-72) months. The mean IKDC score improved from 58 ± 8.3 to 78.2 ± 9.5 (p < 0.001). Post-operatively there were 15 excellent, 11 good and 8 fair outcomes on Lysholm score. The mean pre-operative valgus side-to-side opening improved from 7.5 ± 2.5 mm to 1.2 ± 0.7 mm on stress radiography (p < 0.001). CONCLUSION: Anatomic reconstruction of the superficial medial collateral and posterior oblique ligaments restore stability in a consistent manner cases of chronic grade 3 instability. The objective functional results, subjective outcomes and measures of static medial stability are satisfactory in the short term. LEVEL OF EVIDENCE: IV.


Assuntos
Instabilidade Articular , Ligamento Colateral Médio do Joelho , Adulto , Feminino , Seguimentos , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
3.
J Arthroplasty ; 35(3): 732-740, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31676174

RESUMO

BACKGROUND: Total knee arthroplasty requires careful surgical technique to attain the goal of a well-aligned and symmetrically balanced knee. Soft tissue balance and correct femoral component rotation are paramount in achieving these goals. The two competing techniques to select femoral component rotation and soft tissue balance are the gap balance technique and the measured resection technique. METHODS: We performed a randomized, prospective study to compare the two techniques in patients undergoing simultaneous bilateral total knee arthroplasty, whereby one technique was performed in each knee. Fifty (50) subjects were enrolled into the study. The inclusion criteria were osteoarthritic varus knee deformities with similar deformities in both knees. Subjects were followed up for a minimum of two years. RESULTS: The knees balanced via the gap balance technique had significantly more posterior medial bone removed from the femur than those knees balanced via the measured resection technique (P < .001). Knees in the gap balance group tended to require more medial knee releases in extension and tended to have smaller sized femoral components as a result of cutting more bone from the femur in flexion. The modular tibial polyethylene bearing tended to be thicker in the gap balance group. Despite these differences, average knee flexion and functional revised Oxford Knee Scores at 2-year follow-up were not statistically different. CONCLUSION: At 2-year follow-up, there were no differences between the function and scores using the two techniques. Long-term follow-up will be necessary to evaluate any differences in long-term durability.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Pacientes , Estudos Prospectivos , Amplitude de Movimento Articular
4.
J Arthroplasty ; 33(7): 2293-2300, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29555494

RESUMO

BACKGROUND: Knee instability is emerging as a major complication after total knee arthroplasty (TKA), with ligament laxity and component alignment listed as important contributory factors. Knee balancing remains an art and is largely dependent on the surgeon's subjective "feel." The objectives were to measure the accuracy of an electronic balancing device to document the magnitude of correction in knee balance after soft-tissue releases and measure change in knee laxity after medial release. METHODS: The accuracy of a second-generation electronic ligament-balancing device was compared with that of 2 mechanical balancing instruments. TKA was performed in 12 cadaver knees. Soft-tissue balance was measured sequentially before TKA, after mounting a trial femoral component, after medial release, and after resecting the posterior cruciate ligament. Coronal laxity of the knee under a 10 Nm valgus moment was measured before and after medial release. RESULTS: The electronic balancing instrument was more accurate than mechanical instruments in measuring distracted gap and distraction force. On average, before TKA, the flexion gap was wider than the extension gap, and the medial gap was tighter than the lateral gap. Medial release increased the medial gap in flexion and increased passive knee valgus laxity. Posterior cruciate ligament release increased the tibiofemoral gap in both flexion and extension with a greater increase in the lateral gap. CONCLUSION: The second-generation electronic balancing device was significantly more accurate than mechanical instruments and could record knee balance over the entire range of flexion. More accurate soft-tissue balance may enhance outcomes after TKA.


Assuntos
Artroplastia do Joelho/instrumentação , Instabilidade Articular/prevenção & controle , Ligamento Cruzado Posterior/cirurgia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Cadáver , Humanos , Instabilidade Articular/etiologia , Joelho/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Ligamentos/cirurgia , Amplitude de Movimento Articular
5.
NMR Biomed ; 28(7): 873-80, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25981914

RESUMO

Magnetization transfer (MT) imaging is one way to indirectly assess pools of protons with fast transverse relaxation. However, conventional MT imaging sequences are not applicable to short T2 tissues such as cortical bone. Ultrashort echo time (UTE) sequences with TE values as low as 8 µs can detect signals from different water components in cortical bone. In this study we aim to evaluate two-dimensional UTE-MT imaging of cortical bone and its application in assessing cortical bone porosity as measured by micro-computed tomography (µCT) and biomechanical properties. In total, 38 human cadaveric distal femur and proximal tibia bones were sectioned to produce 122 rectangular pieces of cortical bone for quantitative UTE-MT MR imaging, µCT, and biomechanical testing. Off-resonance saturation ratios (OSRs) with a series of MT pulse frequency offsets (Δf) were calculated and compared with porosity assessed with µCT, as well as elastic (modulus, yield stress, and strain) and failure (ultimate stress, failure strain, and energy) properties, using Pearson correlation and linear regression. A moderately strong negative correlation was observed between OSR and µCT porosity (R(2) = 0.46-0.51), while a moderate positive correlation was observed between OSR and yield stress (R(2) = 0.25-0.30) and failure stress (R(2) = 0.31-0.35), and a weak positive correlation (R(2) = 0.09-0.12) between OSR and Young's modulus at all off-resonance saturation frequencies. OSR determined with the UTE-MT sequence provides quantitative information on cortical bone and is sensitive to µCT porosity and biomechanical function.


Assuntos
Algoritmos , Osso e Ossos/anatomia & histologia , Osso e Ossos/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Força Compressiva/fisiologia , Simulação por Computador , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Porosidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Estresse Mecânico , Resistência à Tração/fisiologia
6.
Clin Orthop Relat Res ; 473(1): 135-40, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25082622

RESUMO

BACKGROUND: At 14- to 17-year followup, we reported successful outcomes of the Press-fit Condylar total knee arthroplasty (TKA) system in 160 TKAs performed between 1986 and 1989. However, there are few published reports on TKA survivorship and patient function that include patients evaluated into the third decade after surgery. QUESTIONS/PURPOSES: The study purpose was to determine (1) the survivorship of the implant; and (2) knee function in patients with this TKA system at a mean 20-year followup. METHODS: We ascertained revision status of all living patients (42 of 160 knees) and all patients (22 knees) who died since the previous study. Among patients alive at the latest followup, Knee Society function scores were obtained and radiographs were evaluated. Kaplan-Meier survivorship analysis with 95% confidence intervals was performed with revision for any reason and aseptic loosening as endpoints. A competing risks analysis with 95% confidence intervals was also performed for revision for any reason as the endpoint. RESULTS: At the mean 20-year (range, 19-25 years) followup, all living patients retained their original implants from the index TKA, exclusive of three polyethylene exchanges. This study demonstrates an 87% Kaplan-Meier survivorship for revision for any reason (95% confidence interval [CI], 80%-92%) and a 98% Kaplan-Meier survivorship for revision for aseptic loosening (95% CI, 93%-99%). Competing risks survivorship was 79% (95% CI, 70%-85%) at 25 years for revision for any reason. Mean Knee Society function score was 46.9. Since the previous study, three revisions have been performed, all for polyethylene wear. CONCLUSIONS: The Press-fit Condylar implant system continues to be successful, maintaining longevity up to 25-year followup. This is one of the longest followup studies, reporting continued successes over 20 years, and should serve as a benchmark for current-generation implants. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Prótese do Joelho , Adulto , Idoso , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia , Recuperação de Função Fisiológica , Reoperação , Fatores de Risco , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento
7.
Cureus ; 16(6): e62063, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989382

RESUMO

BACKGROUND:  Hamstring length plays a significant role in a spectrum of clinical entities, from injury prevention and gait dysfunction to posture correction. Evidence suggests that the prevalence of hamstring tightness (HT)/reduced length is increasing. Despite the number of available tests and treatment protocols, HT is still a functional diagnosis. This study's primary goal is to evaluate concurrent muscle (CM) usage during these testing procedures to design a unique, customized treatment protocol. METHODS: The study was conducted in two stages. In phase 1, Active Straight Leg Raise (ASLR), Active Total Knee Extension (ATKE), and Active Seated Total Knee Extension (ASTKE) were carried out. Next, two pressure gauges (PGs) were placed to align with the natural lumbar and cervical curvatures while testing ASLR and ATKE. After analyzing the results for pressure gauge placement, phase 2 data were collected for tests ASLR and ATKE with PG. RESULTS: The results of ASLR and ATKE, both with and without PG, indicate a high prevalence rate, whereas the results of ASTKE show no prevalence. Changes in the PG values indicate CM usage. Dichotomization revealed that participants with normal test scores (non-HT group) had increased usage of CM work. Positive and negative changes in PG indicate the involved CM group. CONCLUSION(S): In regular practice, most healthcare professionals and fitness trainers prefer ASTKE due to the ease of the testing procedure. Directing co-professionals on their choice of tests is challenging, whereas providing knowledge about CM use paves the way for creating customized treatment plans.

8.
J Robot Surg ; 18(1): 49, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38252199

RESUMO

The study's primary aim is the restoration of native joint line in patients having robotic-assisted unicondylar knee arthroplasty and conventional unicondylar knee arthroplasty. Literature in the past has demonstrated that reducing the joint line can result in greater failure rates. This is a prospective cohort investigation of patients who had medial UKA between March 2017 and March 2022.All patient's pre-operative and post-operative radiological joint line assessments were examined by two observers by Weber's methods. Robotic-assisted UKA performed with hand-held image-free robots was compared to conventional UKA groups. The distal position of the femoral component was higher in Group B utilizing conventional tools than in Group A employing robotic-assisted UKA. This positional difference was statistically significant. The mean difference among the pre-operative and post-operative joint lines in Group A was 1.6 ± 0.49 (range 0.8 mm-2.4 mm), while it was 2.47 ± 0.51 (range 1.6 mm-3.9 mm) (p 0.005) in Group B. In Group A, a greater percentage of the subjects (64%) attained a femoral component position within two millimeters from the joint line, whereas just 18% in Group B did. When compared with the conventional UKA technique, the meticulous attention to detail and planning for ligament rebalancing when using the robotic-assisted UKA technique not solely enhance surgical precision for implant placing but additionally provides excellent native joint line restoration and balancing. For validation of its longevity and survivability, the cohort must be tracked for a longer period of time.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Ligamentos , Período Pós-Operatório
9.
Ann Rheum Dis ; 72(2): 271-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22872023

RESUMO

OBJECTIVES: To determine the histological patterns of posterior cruciate ligament (PCL) degeneration during aging and in relation to changes in articular cartilage and anterior cruciate ligament (ACL) across the entire adult age spectrum. METHODS: Human knee joints (n=120 from 65 donors) were processed within 72 h of postmortem. Articular cartilage surfaces were graded macroscopically. Each PCL was histologically evaluated for inflammation, mucinous changes, chondroid metaplasia, cystic changes and orientation of collagen fibres. The severity of PCL degeneration was classified as normal, mild, moderate or severe. PCL scores were compared to ACL and cartilage scores from the same knees. RESULTS: All knees had intact PCL. Histologically, 6% were normal, 76% showed mild, 12% moderate and 9% severe degeneration. Fibre disorientation was the most prevalent and severe change. Histological grades of PCL and ACL correlated, but significantly fewer PCL than ACL showed severe changes. There was a weaker correlation between aging and total histological PCL scores (R=0.26) compared to aging and ACL scores (R=0.42). ACL scores correlated with cartilage scores (R=0.54) while PCL scores increased with the severity of osteoarthritis from grades 0 to III but not between osteoarthritis grades III-IV (R=0.32). In knees with ruptured ACL, the PCL scores correlated with cartilage scores of the lateral compartment. CONCLUSIONS: PCL histopathological changes were less severe than in the ACL. PCL degeneration was associated with ACL and cartilage damage. The lack of correlation with age indicates independent pathways for PCL versus ACL degeneration.


Assuntos
Envelhecimento/patologia , Ligamento Cruzado Anterior/patologia , Cartilagem Articular/patologia , Articulação do Joelho/patologia , Osteoartrite/patologia , Ligamento Cruzado Posterior/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Arthritis Rheum ; 64(3): 696-704, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22006159

RESUMO

OBJECTIVE: The development and patterns of spontaneous age-related changes in the anterior cruciate ligament (ACL) and their relationship to articular cartilage degeneration are not well characterized. This study was undertaken to investigate the types and temporal sequence of age-related ACL changes and to determine their correlation with cartilage lesion patterns at all stages of osteoarthritis (OA) development in human knee joints without prior joint trauma. METHODS: Human knee joints (n = 120 from 65 donors ages 23-92) were obtained at autopsy, and ACLs and cartilage were graded macroscopically and histologically. Inflammation surrounding the ACL was assessed separately. RESULTS: Histologic ACL substance scores and ligament sheath inflammation scores increased with age. Collagen fiber disorganization was the earliest and most prevalent change. The severity of mucoid degeneration and chondroid metaplasia in the ACL increased with the development of cartilage lesions. A correlation between ACL degeneration and cartilage degeneration was observed, especially in the medial compartment of the knee joint. CONCLUSION: Our findings indicate that ACL degeneration is highly prevalent in knees with cartilage defects and may even precede cartilage changes. Hence, ACL deficiencies may not only be important in posttraumatic OA, but may also be a feature associated with knee OA pathogenesis in general.


Assuntos
Envelhecimento/patologia , Ligamento Cruzado Anterior/patologia , Artropatias/patologia , Articulação do Joelho/patologia , Osteoartrite do Joelho/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligamento Cruzado Anterior/metabolismo , Cartilagem/metabolismo , Cartilagem/patologia , Feminino , Humanos , Inflamação/diagnóstico , Artropatias/metabolismo , Articulação do Joelho/metabolismo , Masculino , Metaplasia/metabolismo , Metaplasia/patologia , Pessoa de Meia-Idade , Muco/metabolismo , Adulto Jovem
11.
J Arthroplasty ; 28(8): 1286-90, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23541870

RESUMO

Median 14-year follow-up (mean 11.8 years) of a cemented primary posterior cruciate-retaining total knee arthroplasty (TKA) utilizing the Press-Fit Condylar (PFC) Sigma design was evaluated in 77 patients (79 TKA). Follow-up assessment included implant survivorship, x-rays, Knee Society rating system, and clinical evaluation. Radiographic analysis demonstrated minor non-progressive osteolysis in 40% (10/25) knees. Two revisions, one for instability at 4 years and one for polyethylene wear at 10 years were performed. Survivorship of the PFC Sigma knee implant was 97% using revision for any reason and 100% using aseptic loosening as endpoints. The PFC Sigma had excellent survivorship at 14 years, the longest clinical follow-up reported.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Polietileno , Cuidados Pós-Operatórios , Desenho de Prótese , Radiografia , Fatores de Tempo , Resultado do Tratamento
12.
Med Biol Eng Comput ; 61(11): 2843-2857, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37495885

RESUMO

Cancer is an illness that instils fear in many individuals throughout the world due to its lethal nature. However, in most situations, cancer may be cured if detected early and treated properly. Computer-aided diagnosis is gaining traction because it may be used as an initial screening test for many illnesses, including cancer. Deep learning (DL) is a CAD-based artificial intelligence (AI) powered approach which attempts to mimic the cognitive process of the human brain. Various DL algorithms have been applied for breast cancer diagnosis and have obtained adequate accuracy due to the DL technology's high feature learning capabilities. However, when it comes to real-time application, deep neural networks (NN) have a high computational complexity in terms of power, speed, and resource usage. With this in mind, this work proposes a miniaturised NN to reduce the number of parameters and computational complexity for hardware deployment. The quantised NN is then accelerated using field-programmable gate arrays (FPGAs) to increase detection speed and minimise power consumption while guaranteeing high accuracy, thus providing a new avenue in assisting radiologists in breast cancer diagnosis using digital mammograms. When evaluated on benchmark datasets such as DDSM, MIAS, and INbreast, the suggested method achieves high classification rates. The proposed model achieved an accuracy of 99.38% on the combined dataset.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Humanos , Feminino , Inteligência Artificial , Aprendizado de Máquina , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Computadores
13.
Proc Inst Mech Eng H ; 226(2): 95-102, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22468461

RESUMO

Knee forces are highly significant in osteoarthritis and in the survival and function of knee arthroplasty. A large number of studies have attempted to estimate forces around the knee during various activities. Several approaches have been used to relate knee kinematics and external forces to internal joint contact forces, the most popular being inverse dynamics, forward dynamics, and static body analyses. Knee forces have also been measured in vivo after knee arthroplasty, which serves as valuable validation of computational predictions. This review summarizes the results of published studies that measured knee forces for various activities. The efficacy of various methods to alter knee force distribution, such as gait modification, orthotics, walking aids, and custom treadmills are analyzed. Current gaps in our knowledge are identified and directions for future research in this area are outlined.


Assuntos
Articulação do Joelho/fisiologia , Modelos Biológicos , Movimento/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Simulação por Computador , Humanos , Estresse Mecânico
14.
Clin Orthop Relat Res ; 469(10): 2953-70, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21598121

RESUMO

BACKGROUND: Tibiofemoral forces are important in the design and clinical outcomes of TKA. We developed a tibial tray with force transducers and a telemetry system to directly measure tibiofemoral compressive forces in vivo. Knee forces and kinematics traditionally have been measured under laboratory conditions. Although this approach is useful for quantitative measurements and experimental studies, the extrapolation of results to clinical conditions may not always be valid. QUESTIONS/PURPOSES: We therefore developed wearable monitoring equipment and computer algorithms for classifying and identifying unsupervised activities outside the laboratory. METHODS: Tibial forces were measured for activities of daily living, athletic and recreational activities, and with orthotics and braces, during 4 years postoperatively. Additional measurements included video motion analysis, EMG, fluoroscopic kinematic analysis, and ground reaction force measurement. In vivo measurements were used to evaluate computer models of the knee. Finite element models were used for contact analysis and for computing knee kinematics from measured knee forces. A third-generation system was developed for continuous monitoring of knee forces and kinematics outside the laboratory using a wearable data acquisition hardware. RESULTS: By using measured knee forces and knee flexion angle, we were able to compute femorotibial AP translation (-12 to +4 mm), mediolateral translation (-1 to 1.5 mm), axial rotation (-3° to 12°), and adduction-abduction (-1° to +1°). The neural-network-based classification system was able to identify walking, stair-climbing, sit-to-stand, and stand-to-sit activities with 100% accuracy. CONCLUSIONS: Our data may be used to improve existing in vitro models and wear simulators, and enhance prosthetic designs and biomaterials.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Telemetria/instrumentação , Tíbia/cirurgia , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artroplastia do Joelho/efeitos adversos , Distinções e Prêmios , Fenômenos Biomecânicos , Desenho Assistido por Computador , Eletromiografia , Exercício Físico , Feminino , Fêmur/fisiopatologia , Análise de Elementos Finitos , Fluoroscopia , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Recreação , Processamento de Sinais Assistido por Computador , Tíbia/fisiopatologia , Transdutores de Pressão , Resultado do Tratamento , Gravação em Vídeo
15.
J Arthroplasty ; 26(6): 972-5, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21130599

RESUMO

At 10 years, we reported survivorship of the Omnifit hydroxyapatite-coated femoral stem and the Omnifit-PSL porous-coated dual-radius acetabular shell (Stryker, Mahwah, NJ) with polyethylene liners sterilized by gamma radiation in air. Our 15-year follow-up examines survivorship and functional outcomes of this system. Ninety-two patients (98 hips) were identified from our database who had been involved with the prior study. The mean follow-up was 14.7 years (range, 11.8-17.0 years). Survival of the stem and cup was 98.8% and 69%, respectively. Osteolysis was seen in 56% of the proximal femur and 5% of the distal femur. This hydroxyapatite-coated stem continues to perform well at 15 years despite poor acetabular results. The performance of this acetabular component is consistent with previous literature.


Assuntos
Acetábulo , Artroplastia de Quadril/instrumentação , Durapatita , Fêmur , Prótese de Quadril , Falha de Prótese , Acetábulo/cirurgia , Adulto , Idoso , Feminino , Fêmur/cirurgia , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Estimativa de Kaplan-Meier , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/epidemiologia , Prevalência , Radiografia
16.
Indian J Orthop ; 55(2): 416-424, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33927820

RESUMO

OBJECTIVES: The objectives were: (1) to analyze the MRI healing rates of bucket-handle meniscus repair; (2) to compare the accuracy of assessment of meniscus healing for conventional MRI and Indirect Magnetic Resonance Arthrography (IMRA); and (3) to identify patients who may require second-look arthroscopy after meniscus repair. METHODS: This is a prospective observational case series of thirty-seven patients with repaired bucket-handle medial meniscus tear with a minimum one year follow-up. Meniscus healing rates were assessed on direct MRI and IMRA using Henning's criteria. At the same time, patients' symptoms were evaluated according to Barrett's criteria and functional outcomes were recorded using International Knee Documentation Committee (IKDC) score, Knee Osteoarthritis and Outcomes Score (KOOS) and Tegner-Lysholm scores. A further clinical review was performed 18 months after the imaging to assess the evolution of symptoms. RESULTS: At a mean of 22.3 ± 7.8 months after the meniscus repair, 56.7% patients showed complete healing and 40.5% patients demonstrated incomplete repair healing on IMRA. 52% patients with complete healing and 40% patients with incomplete healing demonstrated meniscus symptoms. At the second clinical review, 19% patients with complete healing and 20% patients with incomplete healing had meniscus symptoms. There was no co-relation between symptoms, PROMs and healing on MRI. CONCLUSION: Indirect MR arthrography offers distinct advantages over direct MRI for assessment of meniscus healing, especially in symptomatic patients. Patient-reported outcome measures and symptomatology are not co-related with the healing status of the meniscus and they resolve in the majority on longer follow-up. A more conservative approach guided by IMRA to assess meniscus healing will avoid early re-operations.

17.
Indian J Orthop ; 55(5): 1240-1249, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34824725

RESUMO

BACKGROUND: Traditional principles for successful outcomes in Total Hip Arthroplasty (THA) have relied largely on placing the socket in the native position and trying to restore static anatomical femoral parameters gauged on X-rays or intra-operative measurement. Stability is conventionally achieved by making appropriate changes during the time of trial reduction. Post-operative complications of dislocation and significant Limb Length Discrepancy (LLD) requiring foot wear modification represents opposite ends of the spectrum from a biomechanical perspective and these continue to be relatively high. A move towards giving more importance to functional dynamic parameters rather than static anatomical parameters and less reliance on stability testing at trial reduction is warranted. METHODS: Intraoperative 3D functional balancing of THA without stability testing at trial reduction was practiced in all subjects undergoing THA in our unit from April 2014. To date 1019 patients have had their hips replaced with the same technique. They were followed up till April 2020 for post-operative complications of dislocation and significant LLD needing footwear modification. A secondary cohort of 114 patients from 1st January to December 31st 2017 within this primary group were analyzed clinically and radiologically to ascertain the implications of functional 3D balancing on X-ray parameters, clinical outcome scores (Harris Hip Score and Oxford Hip Score), ability to squat, and subtle subjective post-operative perception of limb lengthening (POPLL). RESULTS: In the primary group of 1019 patients, there were only two dislocations and no patient needed footwear modification for LLD. In the detailed analysis of the secondary cohort of 114 patients, the correlation with restoration of static radiological parameters was inconsistent. 40 patients could not squat and 4 patients had subtle subjective post-operative perceived limb lengthening (POPLL). Measured outcomes such as HHS and OHS were improved in all patients with significant statistical significance (P < 0.001). CONCLUSION: This study underlines the fact that more importance must be given to functional dynamic parameters by 3D balancing of the THA and not on static anatomical X-rays parameters and stability testing during trial reduction. This represents a paradigm shift in the evolution of total hip arthroplasty. LEVEL OF EVIDENCE: A Level II study. (Data collected from the ongoing prospective study) (http://www.spine.org/Documents/LevelsofEvidenceFinal.pdf). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s43465-021-00505-3.

18.
JACC Case Rep ; 3(3): 508-511, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34317569

RESUMO

Left atrial appendage closure (LAAC) has evolved as a safe alternative to oral anticoagulation therapy for stroke prophylaxis. However, the presence of a patent foramen ovale (PFO) occluder device is considered a relative contraindication. Here we report a successful case of LAAC in the presence of a PFO occluder device. (Level of Difficulty: Beginner.).

19.
Indian J Orthop ; 55(4): 993-1002, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34194657

RESUMO

BACKGROUND: Total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) are already proven good for end-stage arthritis in the older populations but it is challenging in young teenage patients. The primary aim was to assess Hip Disability and Osteoarthritis Outcome Score (HOSS), Harris Hip Score (HHS) and secondary aim for implant survival rate. MATERIALS AND METHODS: The details of 33 teenage patients (forty hips) who underwent HRA (21) and THA (19) at our institution (January 2002 to December 2013) with a mean follow-up period of 11.00 years (range 7.00-18.40) were included. The study group had 25 males and eight females. RESULTS: The overall median HOOSs with interquartile range were 89.00 (87.63-0.00). The median HOOSs at follow-up were as follows: 95.00 (90.00-95.00) for symptoms, 92.00 (90.00-95.00) pain, 87.00 (85.00-90.00) for functions, 81.00 (75.00-85.00) for sports and 94.00 (88.00-95.00) for QOL. HHS improved significantly from 36.88 ± 6.14 to 90.12 ± 6.56 (p < 0.001). The HHS of HRA group improved from 36.29 ± 5.83 to 89.38 ± 5.23 and THA group improved from 37.26 ± 6.22 to 90.94 ± 7.84. The 5-year radiological follow-up X-rays did not show any radiolucent line wider than 2 mm in all three zones of the acetabulum and no progressive subsidence or migration of > 1 mm and divergent radiopaque line in femur. The Implant survival rate for HRA was 100% at 5 years, 100% at 10 years, 92% at 15 years and THA group was 100% at 5 years and 90% at 10 years. CONCLUSION: Our study showed a disability rate of zero with improved HOSS and HHS. The overall implant survival rate was good with 100% at 5 years, 97% at 10 years and 89.9% at 15 years in contrast to the previous studies with the use of modern implants and newer standard surgical techniques. LEVEL OF EVIDENCE: A Level II study http://www.spine.org/Documents/LevelsofEvidenceFinal.pdf.

20.
J Arthroplasty ; 25(5): 687-91, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19643564

RESUMO

This study examined long-term survivorship of primary total hip arthroplasty (THA) using cementless Harris-Galante porous femoral and Harris-Galante porous I or II acetabular components. Of 113 hips (101 patients) studied, 60 hips (53 patients) were available for follow-up at a mean of 17.2 years after surgery. A total of 10 hips had documented revision, and 2 hips had failed radiographically. The average Harris hip score was 82. Radiographically, 12 hips demonstrated eccentric wear, 8 had osteolysis, and 1 had a broken tine. The overall survival rate was 87.7%; the mean volumetric wear rate was 74.96 mm(3); and the mean polyethylene linear penetration rate was 0.153 mm/y, similar to that of well-cemented THA in other series. This long-term outcome for an early-generation cementless THA is promising and provides a standard by which to judge the newer generation of cementless implants.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Adulto , Idoso , Artroplastia de Quadril/métodos , Parafusos Ósseos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Incidência , Estimativa de Kaplan-Meier , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Estudos Prospectivos , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa