Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Surg ; 36(12): 4722-4731, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34580899

RESUMO

OBJECTIVES: To determine the outcomes of bioprosthetic valve fracture (BVF) in valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) for patients with structural valve degeneration (SVD) of bioprosthetic surgical valves (BSV) implanted during surgical aortic valve replacement (SAVR). METHODS: A systematic review was conducted including studies published by May 2021. The primary endpoints of the study were 30-day mortality, annular rupture, stroke, paravalvular leak, pacemaker implantation, and coronary obstruction. The secondary endpoints were mean valve gradients (mmHg) and aortic valve area (AVA-cm2 ). A meta-analysis was conducted using the software R, version 3.6.3 (R Foundation for Statistical Computing). RESULTS: Four studies including 242 patients met our eligibility criteria. The overall proportions for 30-day mortality, annular rupture, stroke, paravalvular leak, pacemaker implantation and coronary obstruction were 2.1%, <1.0%, <1.5%, <1.0%, <1.0%, and <1.5%, respectively. After ViV-TAVI with BVF, the difference in means for mean valve gradients showed a significant reduction (random-effects model: -26.7; -28.8 to -24.7; p < .001), whereas the difference in means for AVA showed a significant increase (random-effects model: 0.55 cm2 ; 0.13-0.97; p = .029). Despite the improvement in AVA means, these remain too low after the procedure highly likely due to the small size of the bioprosthetic valves implanted during the index SAVR. CONCLUSION: ViV-TAVI with BVF has proven to be a promising option but data are still too scarce to enable us to draw definitive conclusions. Despite the decrease in gradients, postprocedural AVA remains worrisome. Studies with better designs and larger sample sizes are needed to advance this treatment option.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
2.
Curr Atheroscler Rep ; 22(2): 9, 2020 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-32034516

RESUMO

PURPOSE OF REVIEW: This review summarizes the pathophysiology of mitral annular calcification (MAC) with recent findings and current strategies for diagnosis and treatment. RECENT FINDINGS: Major factors in MAC development seem to be shear stress of the flow past the mitral valve, local inflammation, and dysregulation in regulators of mineral metabolism. MAC itself poses daunting technical challenges. Implanting a valve on top of the calcium bar might lead to paravalvular leak (PVL) that is less likely to heal. Annular decalcification allows for better valve seating and potentially better healing and less PVL. This, however, comes with the risk for catastrophic atrioventricular groove disruption. MAC can be sharply dissected with the scalpel; the annulus can be reconstructed with the autologous pericardium. Transcatheter mitral valve replacement is a promising approach in the treatment of patients who are deemed high-risk surgical candidates with severe MAC. MAC is a multifactorial disease that has some commonalities with atherosclerosis, mainly regarding lipid accumulation and calcium deposition. It is of great clinical importance, being a risk marker of cardiovascular events (including sudden death) and, with its progression, can have a negative impact on patients' lives.


Assuntos
Aterosclerose/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Valva Mitral/fisiopatologia , Calcificação Vascular/diagnóstico , Calcificação Vascular/fisiopatologia , Idoso , Cálcio/sangue , Feminino , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Fatores de Risco , Calcificação Vascular/cirurgia
3.
Curr Atheroscler Rep ; 22(2): 2, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-31912380

RESUMO

PURPOSE OF REVIEW: This review summarizes the pathophysiology of calcific aortic valve stenosis (CAVS) and surveys relevant clinical data and basic research that explain how CAVS arises. RECENT FINDINGS: Lipoprotein(a) [Lp(a)], lipoprotein-associated phospholipase A2 (Lp-PLA2), oxidized phospholipids (OxPL), autotaxin, and genetic driving forces such as mutations in LPA gene and NOTCH gene seem to play a major role in the development of CAVS. These factors might well become targets of medical therapy in the coming years. CVAS seems to be a multifactorial disease that has much in common with coronary artery disease, mainly regarding lipidic accumulation and calcium deposition. No clinical trials conducted to date have managed to answer the key question of whether Lp(a) lowering and anti-calcific therapies confer a benefit in terms of reducing incidence or progression of CAVS, although additional outcome trials are ongoing.


Assuntos
Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Calcinose/sangue , Calcinose/fisiopatologia , Calcificação Vascular/sangue , Calcificação Vascular/fisiopatologia , 1-Alquil-2-acetilglicerofosfocolina Esterase/sangue , Animais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/genética , Calcinose/complicações , Calcinose/genética , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/genética , Doença da Artéria Coronariana/fisiopatologia , Progressão da Doença , Humanos , Lipoproteína(a)/sangue , Lipoproteína(a)/genética , Mutação , Fosfolipídeos/sangue , Diester Fosfórico Hidrolases/sangue , Receptor Notch1/genética
4.
Trends Cardiovasc Med ; 33(4): 225-239, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35051591

RESUMO

Mitral valve repair (MVr) restores leaflets coaptation while preserving the patient's own valve. The two main techniques are: (a) chordal replacement ("respect approach"), whereby artificial neochordae are used to resuspend prolapsed segments of the affected leaflet - and (b) leaflet resection ("resect approach"), whereby diseased leaflet segment is resected, and the remaining segments are sutured together. Both techniques of MVr are associated with better long-term results, fewer valve-related complications and lower mortality when compared with mitral valve replacement (MVR). They also restore quality of life and improve survival to rates equivalent to those of the general population. We performed a meta-analysis to pool data of clinical studies that compared outcomes of MVr stratified by the surgical technique. Seventeen studies accounting for 6,046 patients fulfilled our eligibility criteria. The "respect approach" outperformed the "resect approach" with lower permanent pacemaker implantation rates and lower mean gradients. Despite any possible advantages of one technique over the other, which approach is best for each patient must be decided on a case-by-case basis and more long-term follow-up data are warranted.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Qualidade de Vida , Respeito , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
5.
Braz J Cardiovasc Surg ; 36(2): 150-157, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33438845

RESUMO

INTRODUCTION: Aortic diseases are among the most serious cardiovascular diseases; the overall mortality rate due to diseases such as aneurysms and aortic dissections has been estimated at 2.78 per 100,000 persons in 2010, with a higher mortality rate in men than women. Our objective was to evaluate the epidemiological profile of patients with acute type A aortic dissection at a cardiology referral center. METHODS: A retrospective cross-sectional study was performed at a public cardiac center with 24 patients hospitalized from 1/1/2016 to 12/31/2017 with a confirmed diagnosis of acute type A aortic dissection. RESULTS: Twenty (83.3%) out of 24 patients underwent surgery and four (16.7%) did not undergo surgery. Among those who underwent surgery, 10 (50%) died and 10 (50%) were discharged, and all non-operated patients died (P=0.114) (Fisher's exact test). The male gender predominated (n=19, 79.2%), 86.7% (n=13) of the patients presented body mass index > 25 kg/m2, chest pain was found in 91.7% (n=22), and renal failure was present in 45.8% (n=11) of the cases. Hypertension predominated in 91.7% (n=22) and the main exam was aortic angiotomography in 79.2% (n=19) of the cases. CONCLUSION: The study presented a small sample size, making it impossible to associate the factors, although the service was considered a high-volume referral center. It is possible that the delay in arriving at the service and the accomplishment of invasive imaging with the use of contrast agents have aggravated the patients' condition and have been decisive for the increase in lethality, which requires further studies.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Brasil/epidemiologia , Estudos Transversais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
6.
Braz J Cardiovasc Surg ; 35(2): 141-144, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32369292

RESUMO

OBJECTIVE: To test the German Aortic Valve (GAV) score at our university hospital in patients undergoing isolated aortic valve replacement (AVR). METHODS: A total of 224 patients who underwent isolated conventional AVR between January 2015 and December 2018 were included. Patients with concomitant procedures and transcatheter aortic valve implantation were excluded. Patients' data were collected and analyzed retrospectively. Patients' risk scores were calculated according to criteria described by GAV score. Sensitivity, specificity, and accuracy (area under the ROC curve [AUC]) were also calculated. The calibration of the model was tested by the Hosmer-Lemeshow method. RESULTS: The mortality rate was 8.04% (18 patients). The patients' mean age was 58.2±19.3 years and 25% of them were female (56 patients). Mean GAV score was 1.73±5.86 (min: 0.0; max: 3.53). The GAV score showed excellent discriminative capacity (AUC 0.925, 95% confidence interval 0.882-0.956; P<0.001). The cutoff "1.8" turned out to be the best discriminatory point with the best combination of sensitivity (88.9%) and specificity (75.7%) to predict operative death. Hosmer-Lemeshow method revealed a P-value of 0.687, confirming a good calibration of the model. CONCLUSION: The GAV score applies to our population with high predictive accuracy.


Assuntos
Implante de Prótese de Valva Cardíaca , Adulto , Idoso , Valva Aórtica , Estenose da Valva Aórtica , Brasil , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
8.
Braz J Cardiovasc Surg ; 34(5): 610-614, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31719012

RESUMO

In cases of aortic valve disease, prosthetic valves have been increasingly used for valve replacement, however, there are inherent problems with prostheses, and their quality in the so-called Third World countries is lower in comparison to new-generation models, which leads to shorter durability. Recently, transcatheter aortic valve replacement has been explored as a less invasive option for patients with high-risk surgical profile. In this scenario, aortic valve neocuspidization (AVNeo) has emerged as another option, which can be applied to a wide spectrum of aortic valve diseases. Despite the promising results, this procedure is not widely spread among cardiac surgeons yet. Spurred on by the last publications, we went on to write an overview of the current practice of state-of-the-art AVNeo and its results.


Assuntos
Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Glutaral/uso terapêutico , Doenças das Valvas Cardíacas/cirurgia , Pericárdio/transplante , Transplante Autólogo/métodos , Humanos , Reoperação , Resultado do Tratamento
9.
Braz J Cardiovasc Surg ; 34(3): 318-326, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31310471

RESUMO

OBJECTIVES: This study sought to evaluate the impact of prosthesis-patient mismatch (PPM) on the risk of early-term mortality after transcatheter aortic valve implantation (TAVI). METHODS: Databases (Medical Literature Analysis and Retrieval System Online [MEDLINE], Excerpta Medica dataBASE [EMBASE], Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Latin American and Caribbean Literature on Health Sciences [LILACS], and Google Scholar) were searched for studies published until February 2019. PPM after TAVI was defined as moderate if the indexed effective orifice area (iEOA) was between 0.85 cm2/m2 and 0.65 cm2/m2 and as severe if iEOA ≤ 0.65 cm2/m2. RESULTS: The search yielded 1,092 studies for inclusion. Of these, 18 articles were analyzed, and their data extracted. The total number of patients included who underwent TAVI was 71,106. The incidence of PPM after TAVI was 36.3% (25,846 with PPM and 45,260 without PPM). One-year mortality was not increased in patients with any PPM (odds ratio [OR] 1.021, 95% confidence interval [CI] 0.979-1.065, P=0.338) neither in those with moderate PPM (OR 0.980, 95% CI 0.933-1.029, P=0.423). Severe PPM was separately associated with high risk (OR 1.109, 95% CI 1.041-1.181, P=0.001). CONCLUSION: The presence of severe PPM after TAVI increased early-term mortality. Although moderate PPM seemed harmless, the findings of this study cannot not rule out the possibility of it being detrimental, since there are other registries that did not address this issue yet.


Assuntos
Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Humanos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Falha de Tratamento
10.
Braz J Cardiovasc Surg ; 34(4): 396-405, 2019 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-31454193

RESUMO

OBJECTIVE: To evaluate whether there is any difference on the results of patients treated with coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI) in the setting of ischemic heart failure (HF). METHODS: Databases (MEDLINE, Embase, Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Literatura Latino-americana e do Caribe em Ciências da Saúde [LILACS], and Google Scholar) were searched for studies published until February 2019. Main outcomes of interest were mortality, myocardial infarction, repeat revascularization, and stroke. RESULTS: The search yielded 5,775 studies for inclusion. Of these, 20 articles were analyzed, and their data were extracted. The total number of patients included was 54,173, and those underwent CABG (N=29,075) or PCI (N=25098). The hazard ratios (HRs) for mortality (HR 0.763; 95% confidence interval [CI] 0.678-0.859; P<0.001), myocardial infarction (HR 0.481; 95% CI 0.365-0.633; P<0.001), and repeat revascularization (HR 0.321; 95% CI 0.241-0.428; P<0.001) were lower in the CABG group than in the PCI group. The HR for stroke showed no statistically significant difference between the groups (random effect model: HR 0.879; 95% CI 0.625-1.237; P=0.459). CONCLUSION: This meta-analysis found that CABG surgery remains the best option for patients with ischemic HF, without increase in the risk of stroke.


Assuntos
Ponte de Artéria Coronária/mortalidade , Insuficiência Cardíaca/cirurgia , Isquemia Miocárdica/cirurgia , Intervenção Coronária Percutânea/mortalidade , Acidente Vascular Cerebral/etiologia , Idoso , Brasil/epidemiologia , Ponte de Artéria Coronária/efeitos adversos , Métodos Epidemiológicos , Medicina Baseada em Evidências , Feminino , Humanos , Masculino , Metanálise como Assunto , Estudos Multicêntricos como Assunto , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Guias de Prática Clínica como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Literatura de Revisão como Assunto , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento
13.
Rev. bras. cir. cardiovasc ; 36(2): 150-157, Mar.-Apr. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1251090

RESUMO

Abstract Introduction: Aortic diseases are among the most serious cardiovascular diseases; the overall mortality rate due to diseases such as aneurysms and aortic dissections has been estimated at 2.78 per 100,000 persons in 2010, with a higher mortality rate in men than women. Our objective was to evaluate the epidemiological profile of patients with acute type A aortic dissection at a cardiology referral center. Methods: A retrospective cross-sectional study was performed at a public cardiac center with 24 patients hospitalized from 1/1/2016 to 12/31/2017 with a confirmed diagnosis of acute type A aortic dissection. Results: Twenty (83.3%) out of 24 patients underwent surgery and four (16.7%) did not undergo surgery. Among those who underwent surgery, 10 (50%) died and 10 (50%) were discharged, and all non-operated patients died (P=0.114) (Fisher's exact test). The male gender predominated (n=19, 79.2%), 86.7% (n=13) of the patients presented body mass index > 25 kg/m2, chest pain was found in 91.7% (n=22), and renal failure was present in 45.8% (n=11) of the cases. Hypertension predominated in 91.7% (n=22) and the main exam was aortic angiotomography in 79.2% (n=19) of the cases. Conclusion: The study presented a small sample size, making it impossible to associate the factors, although the service was considered a high-volume referral center. It is possible that the delay in arriving at the service and the accomplishment of invasive imaging with the use of contrast agents have aggravated the patients' condition and have been decisive for the increase in lethality, which requires further studies.


Assuntos
Humanos , Masculino , Feminino , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/epidemiologia , Dissecção Aórtica/cirurgia , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/diagnóstico por imagem , Brasil/epidemiologia , Estudos Transversais , Estudos Retrospectivos , Resultado do Tratamento
14.
Rev. bras. cir. cardiovasc ; 35(2): 141-144, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1101481

RESUMO

Abstract Objective: To test the German Aortic Valve (GAV) score at our university hospital in patients undergoing isolated aortic valve replacement (AVR). Methods: A total of 224 patients who underwent isolated conventional AVR between January 2015 and December 2018 were included. Patients with concomitant procedures and transcatheter aortic valve implantation were excluded. Patients' data were collected and analyzed retrospectively. Patients' risk scores were calculated according to criteria described by GAV score. Sensitivity, specificity, and accuracy (area under the ROC curve [AUC]) were also calculated. The calibration of the model was tested by the Hosmer-Lemeshow method. Results: The mortality rate was 8.04% (18 patients). The patients' mean age was 58.2±19.3 years and 25% of them were female (56 patients). Mean GAV score was 1.73±5.86 (min: 0.0; max: 3.53). The GAV score showed excellent discriminative capacity (AUC 0.925, 95% confidence interval 0.882-0.956; P<0.001). The cutoff "1.8" turned out to be the best discriminatory point with the best combination of sensitivity (88.9%) and specificity (75.7%) to predict operative death. Hosmer-Lemeshow method revealed a P-value of 0.687, confirming a good calibration of the model. Conclusion: The GAV score applies to our population with high predictive accuracy.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Implante de Prótese de Valva Cardíaca , Valva Aórtica , Estenose da Valva Aórtica , Brasil , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Medição de Risco
16.
Rev. bras. cir. cardiovasc ; 34(5): 610-614, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1042030

RESUMO

Abstract In cases of aortic valve disease, prosthetic valves have been increasingly used for valve replacement, however, there are inherent problems with prostheses, and their quality in the so-called Third World countries is lower in comparison to new-generation models, which leads to shorter durability. Recently, transcatheter aortic valve replacement has been explored as a less invasive option for patients with high-risk surgical profile. In this scenario, aortic valve neocuspidization (AVNeo) has emerged as another option, which can be applied to a wide spectrum of aortic valve diseases. Despite the promising results, this procedure is not widely spread among cardiac surgeons yet. Spurred on by the last publications, we went on to write an overview of the current practice of state-of-the-art AVNeo and its results.


Assuntos
Humanos , Valva Aórtica/cirurgia , Pericárdio/transplante , Transplante Autólogo/métodos , Glutaral/uso terapêutico , Anuloplastia da Valva Cardíaca/métodos , Doenças das Valvas Cardíacas/cirurgia , Reoperação , Resultado do Tratamento
17.
Rev. bras. cir. cardiovasc ; 34(3): 318-326, Jun. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1013462

RESUMO

Abstract Objectives: This study sought to evaluate the impact of prosthesis-patient mismatch (PPM) on the risk of early-term mortality after transcatheter aortic valve implantation (TAVI). Methods: Databases (Medical Literature Analysis and Retrieval System Online [MEDLINE], Excerpta Medica dataBASE [EMBASE], Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Latin American and Caribbean Literature on Health Sciences [LILACS], and Google Scholar) were searched for studies published until February 2019. PPM after TAVI was defined as moderate if the indexed effective orifice area (iEOA) was between 0.85 cm2/m2 and 0.65 cm2/m2 and as severe if iEOA ≤ 0.65 cm2/m2. Results: The search yielded 1,092 studies for inclusion. Of these, 18 articles were analyzed, and their data extracted. The total number of patients included who underwent TAVI was 71,106. The incidence of PPM after TAVI was 36.3% (25,846 with PPM and 45,260 without PPM). One-year mortality was not increased in patients with any PPM (odds ratio [OR] 1.021, 95% confidence interval [CI] 0.979-1.065, P=0.338) neither in those with moderate PPM (OR 0.980, 95% CI 0.933-1.029, P=0.423). Severe PPM was separately associated with high risk (OR 1.109, 95% CI 1.041-1.181, P=0.001). Conclusion: The presence of severe PPM after TAVI increased early-term mortality. Although moderate PPM seemed harmless, the findings of this study cannot not rule out the possibility of it being detrimental, since there are other registries that did not address this issue yet.


Assuntos
Humanos , Falha de Prótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Índice de Gravidade de Doença , Fatores de Risco , Falha de Tratamento , Medição de Risco
18.
Rev. bras. cir. cardiovasc ; 34(4): 396-405, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1020497

RESUMO

Abstract Objective: To evaluate whether there is any difference on the results of patients treated with coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI) in the setting of ischemic heart failure (HF). Methods: Databases (MEDLINE, Embase, Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Literatura Latino-americana e do Caribe em Ciências da Saúde [LILACS], and Google Scholar) were searched for studies published until February 2019. Main outcomes of interest were mortality, myocardial infarction, repeat revascularization, and stroke. Results: The search yielded 5,775 studies for inclusion. Of these, 20 articles were analyzed, and their data were extracted. The total number of patients included was 54,173, and those underwent CABG (N=29,075) or PCI (N=25098). The hazard ratios (HRs) for mortality (HR 0.763; 95% confidence interval [CI] 0.678-0.859; P<0.001), myocardial infarction (HR 0.481; 95% CI 0.365-0.633; P<0.001), and repeat revascularization (HR 0.321; 95% CI 0.241-0.428; P<0.001) were lower in the CABG group than in the PCI group. The HR for stroke showed no statistically significant difference between the groups (random effect model: HR 0.879; 95% CI 0.625-1.237; P=0.459). Conclusion: This meta-analysis found that CABG surgery remains the best option for patients with ischemic HF, without increase in the risk of stroke.


Assuntos
Humanos , Masculino , Feminino , Idoso , Ponte de Artéria Coronária/mortalidade , Isquemia Miocárdica/cirurgia , Acidente Vascular Cerebral/etiologia , Intervenção Coronária Percutânea/mortalidade , Insuficiência Cardíaca/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Brasil/epidemiologia , Literatura de Revisão como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Metanálise como Assunto , Ponte de Artéria Coronária/efeitos adversos , Métodos Epidemiológicos , Estudos Multicêntricos como Assunto , Resultado do Tratamento , Guias de Prática Clínica como Assunto , Isquemia Miocárdica/mortalidade , Medicina Baseada em Evidências , Acidente Vascular Cerebral/mortalidade , Intervenção Coronária Percutânea/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa