Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int Endod J ; 56(7): 896-908, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37029571

RESUMO

AIM: To compare two flat-side single-file rotary instruments with three single-file reciprocating systems through a multimethod assessment. METHODOLOGY: A total of 290 new NiTi single-file rotary (AF F One Blue 25/0.06 and Platinum V.EU 25/0.06) and reciprocating (One Files Blue R25, Reciproc Blue R25, Reciproc R25) instruments were selected, carefully examined for any major deformations, and evaluated regarding their macroscopic and microscopic design, nickel and titanium elements ratio, phase transformation temperatures, and mechanical performance (time/rotation to fracture, maximum torque, angle of rotation, microhardness, maximum bending, and buckling strengths). One-way anova post hoc Tukey, T-test, and nonparametric Mood's median tests were used for statistical comparisons (α = 5%). RESULTS: Tested instruments had identical blade counts and near-identical helical angles of approximately 24° (rotary instruments) and 151° (reciprocating instruments). The flat-side analysis revealed a few inconsistencies, such as discontinuity segments, different orientations, and gaps in the homogeneity of the bluish colour. Microscopically, flat-side instruments exhibited blade discontinuity and an incomplete S-shaped cross-section. The surface finish was smoother for One Files Blue and more irregular for both rotary instruments. There were distinct phase transformation temperatures amongst all instruments. All heat-treated instruments were in R-phase arrangement, and Reciproc was in R-phase plus austenite at test temperature (20°C). Compared with the reciprocating instruments, both flat-side instruments exhibited lower results in the cyclic fatigue tests using two different clockwise kinematics, maximum torque, angle of rotation, and maximum buckling strength (p < .05). The rotary systems also exhibited low flexibility (p < .05). AF F One Blue had the lowest microhardness, whilst Reciproc had the highest value. CONCLUSION: This multimethod investigation revealed that the flat-side rotary instruments underperformed the reciprocating instruments regarding cyclic fatigue (with two different clockwise kinematics), maximum torque, angle of rotation, maximum buckling strength, and flexibility. Manufacturing inconsistencies were also observed in some of the flat-side instruments, including discontinuity segments, different orientations, and in the homogeneity of their bluish colour given by the heat treatment.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Preparo de Canal Radicular , Teste de Materiais , Titânio , Estresse Mecânico
2.
Int Endod J ; 56(4): 530-542, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36508297

RESUMO

AIM: To compare design, metallurgy and mechanical performance of the ProTaper (PT) Ultimate system with instruments of similar dimensions from the ProGlider, PT Gold and PT Universal systems. METHODOLOGY: New PT Ultimate instruments (n = 248) were compared with instruments of similar dimensions from ProGlider (n = 31), PT Gold (n = 155) and PT Universal (n = 155) systems regarding their number of spirals, helical angle, blade symmetry, tip geometry, surface finishing, nickel/titanium ratio, phase transformation temperatures and mechanical performance. One-way anova and nonparametric Mood's median tests were used for statistical comparison (α = 5%). RESULTS: All instruments had symmetrical blades without radial lands or flat sides, similar surface finishing and an almost equiatomic nickel/titanium ratio, whilst the number of spirals, helical angles and the tip geometry were different. PT Ultimate instruments showed 3 distinct heat treatments that matched with the colour of their metal wire. Slider and ProGlider instruments had similar R-phase start (Rs) and R-phase finish (Rf) temperatures. SX, F1, F2, F3 and Shaper instruments showed equivalent heat treatments (Rs ~45.6°C and Rf ~28.3°C) that were similar to their PT Gold counterparts (Rs ~47.9°C and Rf ~28.2°C), but completely distinct to the PT Universal ones (Rs ~16.2°C and Rf ~-18.2°C). Amongst the PT Ultimate instruments, the lowest maximum torques were observed in the SX (0.44 N cm), Slider (0.45 N cm) and Shaper (0.60 N cm) instruments, whilst the highest was noted in the FXL (4.90 N cm). PT Ultimate Slider and ProGlider had similar torsional (~0.40 N cm) and bending loads (~145.0 gf) (p = 1.000), whilst the other PT Ultimate instruments showed statistically significantly lower maximum torque, higher angle of rotation and lower bending load (higher flexibility) than their counterparts of the PT Universal and PT Gold systems. CONCLUSIONS: The PT Ultimate system comprises instruments with 3 distinct heat treatments that showed similar phase transformation temperatures to their heat-treated analogues. PT Ultimate instruments presented lower torsional strength and superior flexibility than their counterparts, whilst maximum torque, angle of rotation and bending loads progressively increased with their sizes.


Assuntos
Níquel , Titânio , Temperatura Alta , Falha de Equipamento , Teste de Materiais , Ligas Dentárias , Preparo de Canal Radicular , Desenho de Equipamento , Torção Mecânica
3.
Eur Endod J ; 5(3): 212-218, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33353915

RESUMO

OBJECTIVE: The traditional face-to-face or on-site lecturing methods are still among the most common forms of delivering knowledge to students in dental education. However, other innovative learning methodologies have the potential to complement, or even improve, the effectiveness and quality of teaching. The aim of this online survey was to analyze the receptivity of endodontics practitioners to a specific online teaching format of a multi-day congress, mimicking an on-site conference, and perceive whether the participants regarded it as an effective way of acquiring knowledge with application in their clinical practice activity. METHODS: An online questionnaire, composed of 17 items, was sent during the last day of a multi-day online congress. Four strands of information were taken into account: demographics; previous online formation experience; personal involvement in the underway online congress; and overview of the online congress concept. Participation was voluntary and anonymous. Total counts, frequencies and descriptive statistics were generated by using SurveyMonkey software. RESULTS: A total of 1.827 answers were delivered, which represented a return rate of 15.8%. The results indicated that most of the participants agree that online learning could be a good alternative to the traditional on-site learning methodology in improving their practical abilities. In addition, the present survey found that the majority of the attendees support the use of computers as an assisting tool and only 18.0% reported difficulties when using technologies. A high number of practitioners recognized a favourable cost-benefit ratio of using online lessons and stated they would recommend others to participate in online meetings as well. CONCLUSION: Overall, the present results suggest that online learning may be used successfully to improve student's knowledge and enhance their abilities to apply acquired content in clinical situations. Moreover, the participants felt online learning to be effective, engaging and with a favourable cost-benefit ratio.


Assuntos
Endodontia , Aprendizagem , Educação em Odontologia , Retroalimentação , Humanos , Inquéritos e Questionários
4.
Aust Endod J ; 46(3): 452-457, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32896059

RESUMO

Internal root resorption is characterised by progressive loss of tooth substance initiating at the root canal wall as a result of clastic activity. This report describes a case of a perforating internal root resorption on a maxillary central incisor in a 25-year-old patient. The perforating internal root resorption was firstly diagnosed with periapical radiographs and assessed with full detail with the aid of CBCT, allowing determination of the extension and areas involved in the resorption lesion, as well as the treatment planning. According to these findings, a MTA barrier was performed on the root, -coronally to the resorption lesion, leaving the root apically to the resorption lesion untouched. Clinical findings and periapical radiographs indicated complete resolution of the radiolucency associated with the resorptive defect, with reestablishment of lamina dura along the root and occlusion of the lumen of the root canal in the apical segment, after a 5-year follow-up.


Assuntos
Materiais Restauradores do Canal Radicular , Reabsorção da Raiz , Adulto , Compostos de Alumínio , Compostos de Cálcio/uso terapêutico , Combinação de Medicamentos , Seguimentos , Humanos , Óxidos , Materiais Restauradores do Canal Radicular/uso terapêutico , Reabsorção da Raiz/diagnóstico por imagem , Reabsorção da Raiz/terapia , Silicatos/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa