Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int Orthop ; 46(8): 1733-1740, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35593929

RESUMO

PURPOSE: Treatment of symptomatic developmental dysplasia of the hip (DDH) requires a technically demanding total hip arthroplasty (THA) reconstruction. In patients with DDH, prostheses can be difficult to implant and often face the risk of fracture, mismatch, and loosening. The Wagner Cone Prosthesis™ is a tapered, conical stem which can improve treatment success in this population. We look at midterm survivorship and outcomes of THA for DDH using the Wagner Cone Prosthesis™. METHODS: We retrospectively analyzed 28 patients (33 hips) with DDH undergoing THA using the Wagner Cone Prosthesis™ between January 2008 and January 2020. Ten, nine, and fourteen included patients were classified as Hartofilakidis A, B, and C, respectively. Survivorship according to Kaplan-Meier analysis was the primary outcome, with re-operation and revision as endpoints. The Oxford hip score (OHS) was used to assess clinical outcome. We used multivariate analysis to determine predictors of poor outcomes. The average follow-up was 4.6 years, with a minimum of two years. RESULTS: Kaplan-Meier survivorship over the 13-year study period was 93.9 ± 4.2% for all-cause revision as an endpoint and 96.9 ± 3.1% for stem revisions only. The overall reoperation rate was 6.1%, with periprosthetic fracture and dislocation being reasons for re-operation. No patients were revised for aseptic loosening, and no patients were revised for subsidence. OHS improved from 19.3 ± 9.6 (4-39) pre-operatively to 37.6 ± 8.4 (19-48) at latest follow-up (p < 0.05). CONCLUSION: In patients with DDH, THA with the Wagner Cone Prosthesis™ demonstrates excellent clinical, radiographic, and patient-reported functional outcomes at midterm follow-up.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
2.
J Am Acad Orthop Surg ; 32(6): e284-e292, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38166193

RESUMO

BACKGROUND: Utilization of the direct anterior approach (DAA) for total hip arthroplasty (THA) has risen in popularity. Accurate implant placement is a critical factor that influences patient outcomes. The goal of this study was to compare the accuracy and precision of fluoroscopy with imageless optical navigation in DAA THA. METHODS: This was a cohort study of 640 consecutive primary DAA THAs performed with intraoperative fluoroscopy (n = 300 patients) or imageless optical navigation (n = 304 patients). Accuracy was compared by measuring acetabular cup inclination, anteversion, and leg-length discrepancy (LLD). The proportion of implants placed within the Lewinnek safe zone and those placed within a more precise target of 40 ± 5° inclination and 20 ± 5° anteversion was evaluated. RESULTS: According to the Lewinnek criteria, there was no difference in the percentage of implants placed within both inclination and anteversion targets (fluoroscopy: 90.3%; navigation: 88.8%, P = 0.519). Using the more precise targets, navigation increased the implants positioned correctly for both inclination and anteversion (fluoroscopy: 50.3%; navigation: 65.6%, P < 0.001). Navigation increased the proportion of implants positioned within the target anteversion zone (fluoroscopy: 71.3%; navigation: 83.8%, P < 0.001) but not inclination (fluoroscopy: 71.9%; navigation: 76.9%, P = 0.147). The mean LLD was higher with the use of fluoroscopy compared with navigation (5.5 mm, standard deviation: 4.1; 4.6 mm, SD: 3.4, P < 0.005). No difference in dislocation rate was observed ( P = 0.643). CONCLUSION: Both fluoroscopy and imageless optical navigation demonstrated accurate acetabular implant positioning during DAA THA. Navigation was more precise and associated with improved acetabular anteversion placement and restoration of LLD. Navigation is an accurate alternative to fluoroscopy with decreased radiation exposure.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Humanos , Estudos de Coortes , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Fluoroscopia
SELEÇÃO DE REFERÊNCIAS