RESUMO
Rationale: Cardiovascular events after chronic obstructive pulmonary disease (COPD) exacerbations are recognized. Studies to date have been post hoc analyses of trials, did not differentiate exacerbation severity, included death in the cardiovascular outcome, or had insufficient power to explore individual outcomes temporally.Objectives: We explore temporal relationships between moderate and severe exacerbations and incident, nonfatal hospitalized cardiovascular events in a primary care-derived COPD cohort.Methods: We included people with COPD in England from 2014 to 2020, from the Clinical Practice Research Datalink Aurum primary care database. The index date was the date of first COPD exacerbation or, for those without exacerbations, date upon eligibility. We determined composite and individual cardiovascular events (acute coronary syndrome, arrhythmia, heart failure, ischemic stroke, and pulmonary hypertension) from linked hospital data. Adjusted Cox regression models were used to estimate average and time-stratified adjusted hazard ratios (aHRs).Measurements and Main Results: Among 213,466 patients, 146,448 (68.6%) had any exacerbation; 119,124 (55.8%) had moderate exacerbations, and 27,324 (12.8%) had severe exacerbations. A total of 40,773 cardiovascular events were recorded. There was an immediate period of cardiovascular relative rate after any exacerbation (1-14 d; aHR, 3.19 [95% confidence interval (CI), 2.71-3.76]), followed by progressively declining yet maintained effects, elevated after one year (aHR, 1.84 [95% CI, 1.78-1.91]). Hazard ratios were highest 1-14 days after severe exacerbations (aHR, 14.5 [95% CI, 12.2-17.3]) but highest 14-30 days after moderate exacerbations (aHR, 1.94 [95% CI, 1.63-2.31]). Cardiovascular outcomes with the greatest two-week effects after a severe exacerbation were arrhythmia (aHR, 12.7 [95% CI, 10.3-15.7]) and heart failure (aHR, 8.31 [95% CI, 6.79-10.2]).Conclusions: Cardiovascular events after moderate COPD exacerbations occur slightly later than after severe exacerbations; heightened relative rates remain beyond one year irrespective of severity. The period immediately after an exacerbation presents a critical opportunity for clinical intervention and treatment optimization to prevent future cardiovascular events.
Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Doença Pulmonar Obstrutiva Crônica , Humanos , Progressão da Doença , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Arritmias Cardíacas , Insuficiência Cardíaca/epidemiologia , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologiaRESUMO
INTRODUCTION: Development of a rapid means to verify the ventricular tachycardia (VT) isthmus location from heart surface electrogram recordings would be a helpful tool for the electrophysiologist. METHOD: Myocardial infarction was induced in 22 canines by left anterior descending coronary artery ligation under general anesthesia. After 3-5 days, VT was inducible via programmed electrical stimulation at the anterior left ventricular epicardial surface. Bipolar VT electrograms were acquired from 196 to 312 recording sites using a multielectrode array. Electrograms were marked for activation time, and activation maps were constructed. The activation signal, or signature, is defined as the cumulative number of recording sites that have activated per millisecond, and it was utilized to segment each circuit into inner and outer circuit pathways, and as an estimate of best ablation lesion location to prevent VT. RESULTS: VT circuit components were differentiable by activation signals as: inner pathway (mean: 0.30 sites activating/ms) and outer pathway (mean: 2.68 sites activating/ms). These variables were linearly related (p < .001). Activation signal characteristics were dependent in part upon the isthmus exit site. The inner circuit pathway determined by the activation signal overlapped and often extended beyond the activation map isthmus location for each circuit. The best lesion location estimated by the activation signal would likely block an electrical impulse traveling through the isthmus, to prevent VT in all circuits. CONCLUSIONS: The activation signal algorithm, simple to implement for real-time computer display, approximates the VT isthmus location and shape as determined from activation marking, and best ablation lesion location to prevent reinduction.
Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Animais , Cães , Sistema de Condução Cardíaco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , AlgoritmosRESUMO
BACKGROUND: Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic uncertainty arises when reporters are not sure whether the observed LGE is genuine or not. This uncertainty might be resolved by repetition (to remove artifact) or further acquisition of intersecting images, but this must take place before the scan finishes. Real-time quality assurance by humans is a complex task requiring training and experience, so being able to identify which images have an intermediate likelihood of LGE while the scan is ongoing, without the presence of an expert is of high value. This decision-support could prompt immediate image optimization or acquisition of supplementary images to confirm or refute the presence of genuine LGE. This could reduce ambiguity in reports. METHODS: Short-axis, phase-sensitive inversion recovery late gadolinium images were extracted from our clinical cardiac magnetic resonance (CMR) database and shuffled. Two, independent, blinded experts scored each individual slice for "LGE likelihood" on a visual analog scale, from 0 (absolute certainty of no LGE) to 100 (absolute certainty of LGE), with 50 representing clinical equipoise. The scored images were split into two classes-either "high certainty" of whether LGE was present or not, or "low certainty." The dataset was split into training, validation, and test sets (70:15:15). A deep learning binary classifier based on the EfficientNetV2 convolutional neural network architecture was trained to distinguish between these categories. Classifier performance on the test set was evaluated by calculating the accuracy, precision, recall, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Performance was also evaluated on an external test set of images from a different center. RESULTS: One thousand six hundred and forty-five images (from 272 patients) were labeled and split at the patient level into training (1151 images), validation (247 images), and test (247 images) sets for the deep learning binary classifier. Of these, 1208 images were "high certainty" (255 for LGE, 953 for no LGE), and 437 were "low certainty". An external test comprising 247 images from 41 patients from another center was also employed. After 100 epochs, the performance on the internal test set was accuracy = 0.94, recall = 0.80, precision = 0.97, F1-score = 0.87, and ROC AUC = 0.94. The classifier also performed robustly on the external test set (accuracy = 0.91, recall = 0.73, precision = 0.93, F1-score = 0.82, and ROC AUC = 0.91). These results were benchmarked against a reference inter-expert accuracy of 0.86. CONCLUSION: Deep learning shows potential to automate quality control of late gadolinium imaging in CMR. The ability to identify short-axis images with intermediate LGE likelihood in real-time may serve as a useful decision-support tool. This approach has the potential to guide immediate further imaging while the patient is still in the scanner, thereby reducing the frequency of recalls and inconclusive reports due to diagnostic indecision.
Assuntos
Meios de Contraste , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Meios de Contraste/administração & dosagem , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/normas , Bases de Dados Factuais , Miocárdio/patologia , Masculino , Feminino , Imagem Cinética por Ressonância Magnética/normas , Pessoa de Meia-Idade , Cardiopatias/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Variações Dependentes do Observador , Idoso , Imageamento por Ressonância Magnética/normasRESUMO
BACKGROUND: An immediate, temporal risk of heart failure and arrhythmias after a Chronic Obstructive Pulmonary Disease (COPD) exacerbation has been demonstrated, particularly in the first month post-exacerbation. However, the clinical profile of patients who develop heart failure (HF) or atrial fibrillation/flutter (AF) following exacerbation is unclear. Therefore we examined factors associated with people being hospitalized for HF or AF, respectively, following a COPD exacerbation. METHODS: We conducted two nested case-control studies, using primary care electronic healthcare records from the Clinical Practice Research Datalink Aurum linked to Hospital Episode Statistics, Office for National Statistics for mortality, and socioeconomic data (2014-2020). Cases had hospitalization for HF or AF within 30 days of a COPD exacerbation, with controls matched by GP practice (HF 2:1;AF 3:1). We used conditional logistic regression to explore demographic and clinical factors associated with HF and AF hospitalization. RESULTS: Odds of HF hospitalization (1,569 cases, 3,138 controls) increased with age, type II diabetes, obesity, HF and arrhythmia history, exacerbation severity (hospitalization), most cardiovascular medications, GOLD airflow obstruction, MRC dyspnea score, and chronic kidney disease. Strongest associations were for severe exacerbations (adjusted odds ratio (aOR)=6.25, 95%CI 5.10-7.66), prior HF (aOR=2.57, 95%CI 1.73-3.83), age≥80 years (aOR=2.41, 95%CI 1.88-3.09), and prior diuretics prescription (aOR=2.81, 95%CI 2.29-3.45). Odds of AF hospitalization (841 cases, 2,523 controls) increased with age, male sex, severe exacerbation, arrhythmia and pulmonary hypertension history and most cardiovascular medications. Strongest associations were for severe exacerbations (aOR=5.78, 95%CI 4.45-7.50), age≥80 years (aOR=3.15, 95%CI 2.26-4.40), arrhythmia (aOR=3.55, 95%CI 2.53-4.98), pulmonary hypertension (aOR=3.05, 95%CI 1.21-7.68), and prescription of anticoagulants (aOR=3.81, 95%CI 2.57-5.64), positive inotropes (aOR=2.29, 95%CI 1.41-3.74) and anti-arrhythmic drugs (aOR=2.14, 95%CI 1.10-4.15). CONCLUSIONS: Cardiopulmonary factors were associated with hospitalization for HF in the 30 days following a COPD exacerbation, while only cardiovascular-related factors and exacerbation severity were associated with AF hospitalization. Understanding factors will help target people for prevention.
Assuntos
Fibrilação Atrial , Flutter Atrial , Insuficiência Cardíaca , Hospitalização , Doença Pulmonar Obstrutiva Crônica , Humanos , Masculino , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/complicações , Feminino , Estudos de Casos e Controles , Idoso , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/epidemiologia , Flutter Atrial/epidemiologia , Pessoa de Meia-Idade , Fatores de Risco , Idoso de 80 Anos ou mais , Hospitalização/estatística & dados numéricos , Progressão da Doença , Modelos LogísticosRESUMO
Optical mapping is a widely used tool to record and visualize the electrophysiological properties in a variety of myocardial preparations such as Langendorff-perfused isolated hearts, coronary-perfused wedge preparations, and cell culture monolayers. Motion artifact originating from the mechanical contraction of the myocardium creates a significant challenge to performing optical mapping of contracting hearts. Hence, to minimize the motion artifact, cardiac optical mapping studies are mostly performed on non-contracting hearts, where the mechanical contraction is removed using pharmacological excitation-contraction uncouplers. However, such experimental preparations eliminate the possibility of electromechanical interaction, and effects such as mechano-electric feedback cannot be studied. Recent developments in computer vision algorithms and ratiometric techniques have opened the possibility of performing optical mapping studies on isolated contracting hearts. In this review, we discuss the existing techniques and challenges of optical mapping of contracting hearts.
Assuntos
Coração , Miocárdio , Potenciais de Ação/fisiologia , Coração/diagnóstico por imagem , Coração/fisiologiaRESUMO
INTRODUCTION: Measurement of the spatial ventricular gradient (SVG), spatial QRST angles, and other vectorcardiographic measures of myocardial electrical heterogeneity have emerged as novel risk stratification methods for sudden cardiac death and other adverse cardiovascular events. Prior studies of normal limits of these measurements included primarily young, healthy, White volunteers, but normal limits in older patients are unknown. The influence of race and body mass index (BMI) on these measurements is also unclear. METHODS: Normal 12-lead electrocardiograms (ECGs) from a single center were identified. Patients with abnormal cardiovascular, pulmonary, or renal history (assessed by International Classification of Disease [ICD-9/ICD-10] codes) or abnormal cardiovascular imaging were excluded. The SVG and QRST angles were measured and stratified by age, sex, and race. Multivariable linear regression was used to assess the influence of age, BMI, and heart rate (HR) on these measurements. RESULTS: Among 3292 patients, observed ranges of SVG and QRST angles (peak and mean) differed significantly based on sex, age, and race. Sex differences attenuated with increasing age. Men tended to have larger SVG magnitude (60.4 [46.1-77.8] vs. 52.5 [41.3-65.8] mv*ms, p < .0001) and elevation, and more anterior/negative SVG azimuth (-14.8 [-25.1 to -4.3] vs. 1.3 [-9.8 to 10.5] deg, p < .0001) compared to women. Men also had wider QRST angles. Observed ranges varied significantly with BMI and HR. SVG and QRST angle measurements were robust to different filtering bandwidths and moderate fiducial point annotation errors, but were heavily affected by changes in baseline correction. CONCLUSIONS: Age, sex, race, BMI, and HR significantly affect the range of SVG and QRST angles in patients with normal ECGs and no known cardiovascular disease, and should be accounted for in future studies. An online calculator for prediction of these "normal limits" given demographics is provided at https://bivectors.github.io/gehcalc/.
Assuntos
Doenças Cardiovasculares , Humanos , Masculino , Feminino , Idoso , Eletrocardiografia/métodos , Morte Súbita Cardíaca , Frequência Cardíaca , Ventrículos do CoraçãoRESUMO
While sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) is due to arrhythmias, the guidelines for prediction of SCD are based solely on non-electrophysiological methods. This study aims to stimulate thinking about whether the interests of patients with HCM are better served by using current, 'risk factor', methods of prediction or by further development of electrophysiological methods to determine arrhythmic risk. Five published predictive studies of SCD in HCM, which contain sufficient data to permit analysis, were analysed to compute receiver operating characteristics together with their confidence bounds to compare their formal prediction either by bootstrapping or Monte Carlo analysis. Four are based on clinical risk factors, one with additional MRI analysis, and were regarded as exemplars of the risk factor approach. The other used an electrophysiological method and directly compared this method to risk factors in the same patients. Prediction methods that use conventional clinical risk factors and MRI have low predictive capacities that will only detect 50-60% of patients at risk with a 15-30% false positive rate [area under the curve (AUC) = â¼0.7], while the electrophysiological method detects 90% of events with a 20% false positive rate (AUC = â¼0.89). Given improved understanding of complex arrhythmogenesis, arrhythmic SCD is likely to be more accurately predictable using electrophysiologically based approaches as opposed to current guidelines and should drive further development of electrophysiologically based methods.
Assuntos
Arritmias Cardíacas , Cardiomiopatia Hipertrófica , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/complicações , Fatores de Risco , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Curva ROCRESUMO
AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodosRESUMO
AIMS: The response to high frequency stimulation (HFS) is used to locate putative sites of ganglionated plexuses (GPs), which are implicated in triggering atrial fibrillation (AF). To identify topological and immunohistochemical characteristics of presumed GP sites functionally identified by HFS. METHODS AND RESULTS: Sixty-three atrial sites were tested with HFS in four Langendorff-perfused porcine hearts. A 3.5 mm tip quadripolar ablation catheter was used to stimulate and deliver HFS to the left and right atrial epicardium, within the local atrial refractory period. Tissue samples from sites triggering atrial ectopy/AF (ET) sites and non-ET sites were stained with choline acetyltransferase (ChAT) and tyrosine hydroxylase (TH), for quantification of parasympathetic and sympathetic nerves, respectively. The average cross-sectional area (CSA) of nerves was also calculated. Histomorphometry of six ET sites (9.5%) identified by HFS evoking at least a single atrial ectopic was compared with non-ET sites. All ET sites contained ChAT-immunoreactive (ChAT-IR) and/or TH-immunoreactive nerves (TH-IR). Nerve density was greater in ET sites compared to non-ET sites (nerves/cm2: 162.3 ± 110.9 vs. 69.65 ± 72.48; P = 0.047). Overall, TH-IR nerves had a larger CSA than ChAT-IR nerves (µm2: 11 196 ± 35 141 vs. 2070 ± 5841; P < 0.0001), but in ET sites, TH-IR nerves were smaller than in non-ET sites (µm2: 6021 ± 14 586 vs. 25 254 ± 61 499; P < 0.001). CONCLUSIONS: ET sites identified by HFS contained a higher density of smaller nerves than non-ET sites. The majority of these nerves were within the atrial myocardium. This has important clinical implications for devising an effective therapeutic strategy for targeting autonomic triggers of AF.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Fibrilação Atrial/cirurgia , Átrios do Coração , Miocárdio , Sistema Nervoso Autônomo , Ablação por Cateter/métodosRESUMO
AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14â ms, P < 0.01 and 83 ± 18 vs. 90 ± 15â ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2â V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8â mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.
Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodosRESUMO
AIMS: There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. METHODS AND RESULTS: We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097-0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639-2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). CONCLUSION: The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. TRIAL REGISTRATION: Clinical Trials Registration: NCT02459574.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Antiarrítmicos/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Hospitais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , RecidivaRESUMO
BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.
Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , GadolínioRESUMO
BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: Although obesity, defined by body mass index (BMI), has been associated with a higher risk of hospitalisation and more severe course of illness in Covid-19 positive patients amongst the British population, it is unclear if this translates into increased mortality. Furthermore, given that BMI is an insensitive indicator of adiposity, the effect of adipose volume on Covid-19 outcomes is also unknown. METHODS: We used the UK Biobank repository, which contains clinical and anthropometric data and is linked to Public Health England Covid-19 healthcare records, to address our research question. We performed age- and sex- adjusted logistic regression and Chi-squared test to compute the odds for Covid-19-related mortality as a consequence of increasing BMI, and other more sensitive indices of adiposity such as waist:hip ratio (WHR) and percent body fat, as well as concomitant cardiometabolic illness. RESULTS: 13,502 participants were tested for Covid-19 (mean age 70 ± 8 years, 48.9% male). 1582 tested positive (mean age 68 ± 9 years, 52.8% male), of which 305 died (mean age 75 ± 6 years, 65.5% male). Increasing adiposity was associated with higher odds for Covid-19-related mortality. For every unit increase in BMI, WHR and body fat, the odds of death amongst Covid19-positive participants increased by 1.04 (95% CI 1.01-1.07), 10.71 (95% CI 1.57-73.06) and 1.03 (95% CI 1.01-1.05), respectively (all p < 0.05). Referenced to Covid-19 positive participants with a normal weight (BMI 18.5-25 kg/m2), Covid-19 positive participants with BMI > 35 kg/m2 had significantly higher odds of Covid-19-related death (OR 1.70, 95% CI 1.06-2.74, p < 0.05). Covid-19-positive participants with metabolic (diabetes, hypertension, dyslipidaemia) or cardiovascular morbidity (atrial fibrillation, angina) also had higher odds of death. CONCLUSIONS: Anthropometric indices that are more sensitive to adipose volume and its distribution than BMI, as well as concurrent cardiometabolic illness, are associated with higher odds of Covid-19-related mortality amongst the UK Biobank cohort that tested positive for the infection. These results suggest adipose volume may contribute to adverse Covid-19-related outcomes associated with obesity.
Assuntos
Adiposidade/fisiologia , COVID-19/mortalidade , Doenças Cardiovasculares/epidemiologia , Síndrome Metabólica/epidemiologia , Obesidade/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Bancos de Espécimes Biológicos/estatística & dados numéricos , Índice de Massa Corporal , COVID-19/complicações , COVID-19/patologia , Fatores de Risco Cardiometabólico , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/mortalidade , Estudos de Coortes , Bases de Dados Factuais , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Síndrome Metabólica/complicações , Síndrome Metabólica/mortalidade , Pessoa de Meia-Idade , Morbidade , Mortalidade , Obesidade/complicações , Obesidade/mortalidade , Fatores de Risco , SARS-CoV-2/fisiologia , Reino Unido/epidemiologiaRESUMO
We describe a human and large animal Langendorff experimental apparatus for live electrophysiological studies and measure the electrophysiological changes due to gap junction uncoupling in human and porcine hearts. The resultant ex vivo intact human and porcine model can bridge the translational gap between smaller simple laboratory models and clinical research. In particular, electrophysiological models would benefit from the greater myocardial mass of a large heart due to its effects on far-field signal, electrode contact issues and motion artefacts, consequently more closely mimicking the clinical setting. Porcine (n = 9) and human (n = 4) donor hearts were perfused on a custom-designed Langendorff apparatus. Epicardial electrograms were collected at 16 sites across the left atrium and left ventricle. A total of 1 mM of carbenoxolone was administered at 5 ml/min to induce cellular uncoupling, and then recordings were repeated at the same sites. Changes in electrogram characteristics were analysed. We demonstrate the viability of a controlled ex vivo model of intact porcine and human hearts for electrophysiology with pharmacological modulation. Carbenoxolone reduces cellular coupling and changes contact electrogram features. The time from stimulus artefact to (-dV/dt)max increased between baseline and carbenoxolone (47.9 ± 4.1-67.2 ± 2.7 ms) indicating conduction slowing. The features with the largest percentage change between baseline and carbenoxolone were fractionation + 185.3%, endpoint amplitude - 106.9%, S-endpoint gradient + 54.9%, S point - 39.4%, RS ratio + 38.6% and (-dV/dt)max - 20.9%. The physiological relevance of this methodological tool is that it provides a model to further investigate pharmacologically induced pro-arrhythmic substrates.
Assuntos
Coração/fisiologia , Preparação de Coração Isolado/métodos , Adulto , Animais , Carbenoxolona/farmacologia , Eletrocardiografia/métodos , Acoplamento Excitação-Contração , Feminino , Coração/efeitos dos fármacos , Humanos , Preparação de Coração Isolado/instrumentação , Masculino , Miocárdio/metabolismo , SuínosRESUMO
AIMS: A prolonged PR interval may adversely affect ventricular filling and, therefore, cardiac function. AV delay can be corrected using right ventricular pacing (RVP), but this induces ventricular dyssynchrony, itself harmful. Therefore, in intermittent heart block, pacing avoidance algorithms are often implemented. We tested His-bundle pacing (HBP) as an alternative. METHODS: Outpatients with a long PR interval (>200 ms) and intermittent need for ventricular pacing were recruited. We measured within-patient differences in high-precision hemodynamics between AV-optimized RVP and HBP, as well as a pacing avoidance algorithm (Managed Ventricular Pacing [MVP]). RESULTS: We recruited 18 patients. Mean left ventricular ejection fraction was 44.3 ± 9%. Mean intrinsic PR interval was 266 ± 42 ms and QRS duration was 123 ± 29 ms. RVP lengthened QRS duration (+54 ms, 95% CI 42-67 ms, p < .0001) while HBP delivered a shorter QRS duration than RVP (-56 ms, 95% CI -67 to -46 ms, p < .0001). HBP did not increase QRS duration (-2 ms, 95% CI -8 to 13 ms, p = .6). HBP improved acute systolic blood pressure by mean of 5.0 mmHg (95% CI 2.8-7.1 mmHg, p < .0001) compared to RVP and by 3.5 mmHg (95% CI 1.9-5.0 mmHg, p = .0002) compared to the pacing avoidance algorithm. There was no significant difference in hemodynamics between RVP and ventricular pacing avoidance (p = .055). CONCLUSIONS: HBP provides better acute cardiac function than pacing avoidance algorithms and RVP, in patients with prolonged PR intervals. HBP allows normalization of prolonged AV delays (unlike pacing avoidance) and does not cause ventricular dyssynchrony (unlike RVP). Clinical trials may be justified to assess whether these acute improvements translate into longer term clinical benefits in patients with bradycardia indications for pacing.
Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Algoritmos , Hemodinâmica , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
The non-invasive estimation of blood oxygen saturation (SpO2) by pulse oximetry is of vital importance clinically, from the detection of sleep apnea to the recent ambulatory monitoring of hypoxemia in the delayed post-infective phase of COVID-19. In this proof of concept study, we set out to establish the feasibility of SpO2 measurement from the ear canal as a convenient site for long term monitoring, and perform a comprehensive comparison with the right index finger-the conventional clinical measurement site. During resting blood oxygen saturation estimation, we found a root mean square difference of 1.47% between the two measurement sites, with a mean difference of 0.23% higher SpO2 in the right ear canal. Using breath holds, we observe the known phenomena of time delay between central circulation and peripheral circulation with a mean delay between the ear and finger of 12.4 s across all subjects. Furthermore, we document the lower photoplethysmogram amplitude from the ear canal and suggest ways to mitigate this issue. In conjunction with the well-known robustness to temperature induced vasoconstriction, this makes conclusive evidence for in-ear SpO2 monitoring being both convenient and superior to conventional finger measurement for continuous non-intrusive monitoring in both clinical and everyday-life settings.
Assuntos
Meato Acústico Externo , Hipóxia/diagnóstico , Monitorização Fisiológica/instrumentação , Oximetria/instrumentação , Fotopletismografia/instrumentação , Dispositivos Eletrônicos Vestíveis , Adulto , Betacoronavirus/fisiologia , COVID-19 , Infecções por Coronavirus/sangue , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/terapia , Estudos de Equivalência como Asunto , Estudos de Viabilidade , Feminino , Dedos , Humanos , Hipóxia/sangue , Masculino , Monitorização Fisiológica/métodos , Oximetria/métodos , Oxigênio/análise , Oxigênio/sangue , Pandemias , Fotopletismografia/métodos , Pneumonia Viral/sangue , Pneumonia Viral/diagnóstico , Pneumonia Viral/terapia , SARS-CoV-2 , Adulto JovemRESUMO
BACKGROUND: Conventional mapping techniques during atrial fibrillation (AF) are difficult to apply because of cycle length irregularity. Mapping studies are usually restricted to short durations of AF in limited regions because of the laborious manual annotation of local activation time (LAT). The purpose of this study was to test an automated algorithm to map activation during AF, with comparable accuracy to manual annotation. METHODS: Left atrial (LA) mapping was performed using a 20-pole double loop catheter (AFocusII) in 30-second data segments from 16 patients. The new algorithm (RETRO-Mapping) was designed to detect wavefront propagation between electrodes, and display activating wavefronts on a two-dimensional representation of the catheter. Activation patterns were validated against their bipolar electrograms and with isochronal maps. The mapping protocol was approved by the research ethics committee (13/LO1169 and 14/LO1367). RESULTS: During AF, uniform wavefront activation direction (mean ± SD, degrees) from manually constructed isochronal maps was comparable to RETRO-Propagation Map (RETRO-PM) and RETRO-Automated Direction (RETRO-AD): 1 ± 6.9 for RETRO-PM; and 2 ± 6.6 for RETRO-AD. There was no significant difference in activation direction assigned to 1373 uniform wavefronts during AF when comparing RETRO-PM with RETRO-AD (Bland-Altman mean difference: -0.1 degrees; limits of agreement: -8.0 to 8.3; 95% CI -0.4 to 0.2; (r = 0.01) R2 = < 0.005; P = .77). CONCLUSION: We have developed and validated a new technique to map activation during AF. This technique shows comparable accuracy to that of conventional isochronal mapping with careful manual adjustment of LAT.
Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Automação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de TempoRESUMO
AIMS: Abnormal rate adaptation of the action potential is proarrhythmic but is difficult to measure with current electro-anatomical mapping techniques. We developed a method to rapidly quantify spatial discordance in whole heart activation in response to rate cycle length changes. We test the hypothesis that patients with underlying channelopathies or history of aborted sudden cardiac death (SCD) have a reduced capacity to maintain uniform activation following exercise. METHODS AND RESULTS: Electrocardiographical imaging (ECGI) reconstructs >1200 electrograms (EGMs) over the ventricles from a single beat, providing epicardial whole heart activation maps. Thirty-one individuals [11 SCD survivors; 10 Brugada syndrome (BrS) without SCD; and 10 controls] with structurally normal hearts underwent ECGI vest recordings following exercise treadmill. For each patient, we calculated the relative change in EGM local activation times (LATs) between a baseline and post-exertion phase using custom written software. A ventricular conduction stability (V-CoS) score calculated to indicate the percentage of ventricle that showed no significant change in relative LAT (<10 ms). A lower score reflected greater conduction heterogeneity. Mean variability (standard deviation) of V-CoS score over 10 consecutive beats was small (0.9 ± 0.5%), with good inter-operator reproducibility of V-CoS scores. Sudden cardiac death survivors, compared to BrS and controls, had the lowest V-CoS scores post-exertion (P = 0.011) but were no different at baseline (P = 0.50). CONCLUSION: We present a method to rapidly quantify changes in global activation which provides a measure of conduction heterogeneity and proof of concept by demonstrating SCD survivors have a reduced capacity to maintain uniform activation following exercise.
Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração/fisiopatologia , Estresse Fisiológico/fisiologia , Fibrilação Ventricular/fisiopatologia , Potenciais de Ação/fisiologia , Adulto , Síndrome de Brugada/diagnóstico por imagem , Estudos de Casos e Controles , Eletrocardiografia/métodos , Teste de Esforço , Feminino , Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Sobreviventes , Teste da Mesa Inclinada , Tomografia Computadorizada por Raios X , Fibrilação Ventricular/diagnóstico por imagem , Dispositivos Eletrônicos VestíveisRESUMO
AIMS: Ablation of persistent atrial fibrillation (PsAF) has been performed by many techniques with varying success rates. This may be due to ablation techniques, patient demographics, comorbidities, and trial design. We conducted a meta-regression of studies of PsAF ablation to elucidate the factors affecting atrial fibrillation (AF) recurrence. METHODS AND RESULTS: Databases were searched for prospective studies of PsAF ablation. A meta-regression was performed. Fifty-eight studies (6767 patients) were included. Complex fractionated atrial electrogram (CFAE) ablation reduced freedom from AF by 8.9% [95% confidence interval (CI) -15 to -2.3, P = 0.009). Left atrial appendage [LAA isolation (three study arms)] increased freedom from AF by 39.5% (95% CI 9.1-78.4, P = 0.008). Posterior wall isolation (PWI) (eight study arms) increased freedom from AF by 19.4% (95% CI 3.3-38.1, P = 0.017). Linear ablation or ganglionated plexi ablation resulted in no significant effect on freedom from AF. More extensive ablation increased intraprocedural AF termination; however, intraprocedural AF termination was not associated with improved outcomes. Increased left atrial diameter was associated with a reduction in freedom from AF by 4% (95% CI -6.8% to -1.1%, P = 0.007) for every 1 mm increase in diameter. CONCLUSION: Linear ablation, PWI, and CFAE ablation improves intraprocedural AF termination, but such termination does not predict better long-term outcomes. Study arms including PWI or LAA isolation in the lesion set were associated with improved outcomes in terms of freedom from AF; however, further randomized trials are required before these can be routinely recommended. Left atrial size is the most important marker of AF chronicity influencing outcomes.